The sensor for every occasion: VA-300

Similar documents
Regards from the Team at Rheology Solutions.

TORRIX Magnetostrictive level sensor

OPTISWITCH 4000/5000. Vibration level switches for liquids

Level Limit Switch liquiphant FTL 365 / FTL 366

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.

CombiTemp Temperature Measuring System

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

KDM ARMORED FLOW METER & SWITCH

Level Limit Switch liquiphant FTL 360 / FTL 361

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Coriolis Mass Flowmeter for low flow measurements

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Differential Pressure Gauges (701P Series)

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Metal tube variable area flowmeter for gases, liquids and steam

Magnetic-inductive flow meter for hazardous areas

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Food & beverage. Oil & gas. Water & waste water

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

SITRANS F C. Flow sensor MC2 4/193. Overview

Ultimate Low Flow Coriolis Mass Flowmeter

SITRANS P measuring instruments for pressure

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Bypass level indicator With magnetic display Model BNA for nuclear power plants

SITRANS F flowmeters SITRANS F C

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Hydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

FS10. Vertically-Mounted Magnetic Float Level Sensor. Level Measurement and Monitoring. reliable and robust, heavy-duty technology

Pressure transducer DMU 01K Compact version

Peter Meyer Ball valves Cryogenic

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Mobrey MSM400 Ultrasonic sludge density measurement system

RHM Coriolis Mass Flowmeter for high Flow Applications

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Options guide. Electromagnetic flowmeters. M9xx

V Rev US

VersaFlow Vortex 100 Vortex Flow Meter Specifications

FLOW. control. switch measure. Flow Switches

Level limit switch Series RF 3000 Selection list

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

OPTIFLUX 6000 Technical Datasheet

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

Point level measurement Capacitance switches

Pump kits. We deliver values.

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

SATRON VDt Differential Pressure Transmitter

Air operated Pinch Valve type VMC

MX-SERIES OVAL GEAR FLOW METERS

IGATEC - Standard - Swivel Joints

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

ORIMAS Mass Flowmeter

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

ABB Instrumentation. Thermal Mass Flowmeter Sensyflow. Intelligent solutions for accurate gas mass flow measurement

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

ASKA CORPORATION. Corporate Profile and Product Introduction

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Plastic tube variable area flowmeter for liquids and gases

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

OPTISWITCH 6500 C Technical Datasheet

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Why measure viscosity in-line?

Flow Measurement SITRANS F C

Capacitive Sensors. Series 80 - PNP

Continuous level measurement Capacitance transmitters

From lab to production, providing a window into the process

RHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min

PISTON DIVERTER VALVES

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

The right choice for your application. Pressure sensors from ifm.

WEDGE & SLAB GATE VALVES

Process Industry. Diaphragm Seal Solutions

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

STEEMCO-MAS Flowmeter for Steam

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Quantometer MZ. Description

Sample gas pumps P2.x ATEX

Level Measurement Point level measurement - RF Capacitance switches

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

Process pressure. Overview 168 VEGABAR series VEGABAR series Accessory 184. Process pressure VEGABAR

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Masoneilan Series

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Pressure transmitter COMPACT ECOnomic

Transcription:

The sensor for every occasion: VA-300 VA-300H-ST with flange 2.5 2500# and special non-active-extension (NAE) for operation in polymer melts at 280 C and 175 bar in hazardous area The ViscoScope VA-300 sensor can be used for practically any application, in which constant monitoring of viscosity is required. The sensor measures the dynamic viscosity precisely, reliably and in real-time. Reproducible measurements are essential both for quality control assurance and for process optimisation with the corresponding documentation. Manufacturing the sensors to order means they can be installed in the ideal position in the plant and modifications can be avoided or minimised. The completely welded design of the sensor probe ensures no moving parts are in contact with the fluid being measured. The low amplitude of the resonance frequency oscillation used by the sensor prevents material fatigue. As a result, the instrument requires virtually no maintenance. A variety of sensor probe types guarantee the optimal measurement in the specified viscosity range. And this is achieved both under normal conditions and under the toughest conditions such as high temperature and pressure in hazardous areas. You can find technical information regarding the sensors on the reverse side of this leaflet. We will be happy to advise you in selecting the correct instrument.

Overview of the various sensors Sensor type VA-300L large cylinder VA-300M small cylinder VA-300H sphere VA-300X mini sphere Viscosity range in mpa s x gr/cm 3 0.1 2,500 1 25,000 10 250,000 100 2,500,000 Probe size Material Protection Process temperature (Pt100 is integrated into viscosity probe) Process connection Flange Pressure Installation Resonance frequency Shear rate Cable length Sensor - Transmitter Speed of flow Reproducibility Accuracy ø 32 x 187 mm ø 1.25 x 7.5 ø 32 x 165 mm ø 1.25 x 6.5 ø 32 x 127 mm ø 1.25 x 5 1.4571 and 316L (option: Hastelloy C22, Duplex 2205, teflon coating) IP65 LT from -40 C to 130 C / -40 F to 270 F ST from -40 C to 300 C / -40 F to 570 F HT from -40 C to 450 C / -40 F to 840 F ST and HT with air cooling, dependend on installation Standard DN80 PN40 or ANSI 3 300# others on request Vacuum up to 450 bar / 6,500 psi ø 19 x 114 mm ø 0.75 x 4.5 Installation in any orientation in reactor, vessel, pipe, flow-through cell ~ 550 Hz ~ 580 Hz ~ 600 Hz ~ 635 Hz ~ 3450 sec -1 ~ 3650 sec -1 ~ 3800 sec -1 ~ 4000 sec -1 ± 0,3% or ± 1% or maximum 1,000 meters / 3,330 feet short cable length recommended for very low viscosities up to 10 m / sec. or 33 feet / sec., dependend on installation ± 0,3% or ± 1% or option: hazardous area ATEX: II 1/2 G EEx ia IIC T3 T6 option: non-activeextension (NAE) ± 0,5% ± 0,5% ± 1% ± 1% Eliminates no-flow areas in a pipe connection on a reactor, in a T-piece or flowthrough cell. Can also be used to bridge gaps in open channel applications. Sizes on request. Subject to change without notice. Sometimes process technology, applications or local conditions demand the design of the special instrument. The VA-300S (special) sensor is intended for precisely these applications. If it is technically possible, it can be accomplished with this instrument. Bergiusstrasse 6 Tel.: +49-(0)2045-4038-0 info@marimex.de 46244 Bottrop / Germany Fax: +49-(0)2045-4038-19 www.marimex.de Marimex 03/11

ViscoScope VA-300L sensor The sensor for low viscosities ViscoScope-Sensor Model VA-300L-ST with flange DN100 PN16 and non-activ-extension (NAE) 38 x 100 mm / 1.5 x 4 The VA-300L (low viscosity) sensor with the large cylinder is particularly suitable for measurements between 0.1 and 2,500 mpa s. Even viscosities in the lower range can be detected with precision. When used in non-newtonian and Newtonian fluids such as synthetic resins, polymers, oils, varnishes and paints or milk products, the reproducibility is ± 0.3% or ± 1 digit of the reading taken. The Pt100 temperature sensor, which is integrated into the sensor probe, enables the user to calculate a reliable temperature-compensated viscosity. This provides the data required for optimal monitoring of the process within strict limits during both continuous and batch production. Depending on the application, the sensor can be mounted in any position in a reactor, pipe or flow-through cell. We will be happy to advise you on selecting the installation position. Our wide-ranging experience ensures that you benefit from the best possible use of the system. Typical Applications l Resins l Suspensions l Detergents l Polymers l Paints + Varnish l Milk Powder l Petro chemicals l Coatings l Mustard

Sensor Specification Sensor type VA-300L - large cylinder Viscosity range 0.1 2,500 mpa s x gr/cm 3 Calibration in 3 dekades Probe size ø 32 x 187 mm / ø 1.25 x 7.5 Material Protection Process temperature (Pt100 is integrated into viscosity probe) Process connection Flange Pressure Installation Resonance frequency Shear rate Cable length Sensor - Transmitter Speed of flow Reproducibility Accuracy 1.4571 and 316L option: Hastelloy C22, Duplex 2205, teflon coating IP65 LT from -40 C to 130 C / -40 F to 270 F ST from -40 C to 300 C / -40 F to 570 F HT from -40 C to 450 C / -40 F to 840 F ST and HT with air cooling, dependend on installation Standard DN80 PN40 or ANSI 3 300# others on request Vacuum up to 450 bar / 6,500 psi Installation in any orientation in reactor, vessel, pipe, flow-through cell ~ 550 Hz ~ 3450 sec -1 maximum 1,000 meters / 3,330 feet short cable length recommended for very low viscosities up to 10 m / sec. or 33 feet / sec., dependend on installation ± 0,3% or ± 1% or option: hazardous area ATEX: II 1/2 G EEx ia IIC T3 T6 option: non-active-extension (NAE) Eliminates no-flow areas in a pipe connection on a reactor, in a T-piece or flow-through cell. Can also be used to bridge gaps in open channel applications. Sizes on request. 338 mm 187 mm 151 mm 113 mm ø 32 mm Bergiusstrasse 6 Tel.: +49-(0)2045-4038-0 info@marimex.de 46244 Bottrop / Germany Fax: +49-(0)2045-4038-19 www.marimex.de Marimex 03/11

ViscoScope VA-300M sensor The allrounder for medium viscosities ViscoScope-Sensor Model VA-300M-ST with flange DN80 PN40 and non-active-extension (NAE) 44 x 50 mm / 1.75 x 2 Many products are manufactured in a viscosity range up to 25,000 mpa s. For these processes, we recommend the VA-300M (medium viscosity) sensor with the small cylinder. Reproducibility is ± 0.3% or ± 1 digit of the reading taken over the full measurement range in both non-newtonian and Newtonian fluids. A Pt100 temperature sensor, which is integrated into the sensor probe, records the process temperature at precisely the location where the viscosity is also measured. This makes it possible to calculate a temperature-compensated viscosity for perfect regulation of the process. The sensor can be mounted in any position in a reactor, vessel or pipe for both continuous and batch processes. Take advantage of our wide-ranging experience in order to benefit fully from the use of this system. We will be happy to advise you. Typical Applications l Resins l Black Liquor l Starch l Polymers l Dispensions l Food l Petro chemical l Ceramics l Pharmaceuticals

Sensor Specification Sensor type VA-300M - small cylinder Viscosity range 1 25,000 mpa s x gr/cm 3 Calibration in 3 decades, option 4 decades Probe size ø 32 x 165 mm / ø 1.25 x 6.5 Material Protection Process temperature (Pt100 is integrated into viscosity probe) Process connection Flange Pressure Installation Resonance frequency Shear rate Cable length Sensor - Transmitter Speed of flow Reproducibility Accuracy 1.4571 and 316L option: Hastelloy C22, Duplex 2205, teflon coating IP65 LT from -40 C to 130 C / -40 F to 270 F ST from -40 C to 300 C / -40 F to 570 F HT from -40 C to 450 C / -40 F to 840 F ST and HT with air cooling, dependend on installation Standard DN80 PN40 or ANSI 3 300# others on request Vacuum up to 450 bar / 6,500 psi Installation in any orientation in reactor, vessel, pipe, flow-through cell ~ 580 Hz ~ 3650 sec -1 maximum 1,000 meters / 3,330 feet short cable length recommended for very low viscosities up to 10 m / sec. or 33 feet / sec., dependend on installation ± 0,3% or ± 1% or option: hazardous area ATEX: II 1/2 G EEx ia IIC T3 T6 option: non-active-extension (NAE) Eliminates no-flow areas in a pipe connection on a reactor, in a T-piece or flow-through cell. Can also be used to bridge gaps in open channel applications. Sizes on request. 316 mm 165 mm 151 mm 113 mm ø 32 mm Bergiusstrasse 6 Tel.: +49-(0)2045-4038-0 info@marimex.de 46244 Bottrop / Germany Fax: +49-(0)2045-4038-19 www.marimex.de Marimex 03/11

ViscoScope VA-300H sensor The sensor for high viscosities ViscoScope-Sensor Model VA-300H-ST with flange DN100 PN16 and non-active-extension (NAE) 38 x 75 mm / 1.5 x 3 The VA-300H (high viscosity) sensor with the sphere is used for monitoring highly viscous media between 25,000 and 250,000 mpa s. Suitable for use, e.g. in polymer melts, the sensor provides reliable measurements with a reproducibility of ± 0.5% of the reading taken. The Pt100 temperature sensor integrated into the sensor probe has a resolution of 0.1 C and provides the data required for calculating the temperature-compensated viscosity. This makes it possible to control continuous or batch processes within strict specification limits. This type of sensor can be mounted in any position in reactors or pipes. In order to bridge and avoid no-flow zones, the sensor is often fitted with a non-active extension (NAE) Benefit from our wide-ranging experience. We will be happy to advise you about which system configuration best suits your application to ensure you enjoy all the advantages it provides. Typical Applications l Resins l Plastics l Starch l Polymers l Additives l Food l Silicon l Ceramics l Pharmaceuticals

Sensor Specification Sensor type VA-300H - sphere Viscosity range 10 250,000 mpa s x gr/cm 3 Calibration in 3 decades, option 4 decades Probe size ø 32 x 127 mm / ø 1.25 x 5 Material Protection Process temperature (Pt100 is integrated into viscosity probe) Process connection Flange Pressure Installation Resonance frequency Shear rate Cable length Sensor - Transmitter Speed of flow 1.4571 and 316L option: Hastelloy C22, Duplex 2205, teflon coating IP65 LT from -40 C to 130 C / -40 F to 270 F ST from -40 C to 300 C / -40 F to 570 F HT from -40 C to 450 C / -40 F to 840 F ST and HT with air cooling, dependend on installation Standard DN80 PN40 or ANSI 3 300# others on request Vacuum up to 450 bar / 6,500 psi Installation in any orientation in reactor, vessel, pipe, flow-through cell ~ 600 Hz ~ 3800 sec -1 maximum 1,000 meters / 3,330 feet up to 10 m / sec. or 33 feet / sec., dependend on installation Reproducibility ± 0,5% Accuracy ± 1% option: hazardous area ATEX: II 1/2 G EEx ia IIC T3 T6 option: non-active-extension (NAE) Eliminates no-flow areas in a pipe connection on a reactor, in a T-piece or flow-through cell. Can also be used to bridge gaps in open channel applications. Sizes on request. 278 mm 127 mm 151 mm ø 32 mm 113 mm Bergiusstrasse 6 Tel.: +49-(0)2045-4038-0 info@marimex.de 46244 Bottrop / Germany Fax: +49-(0)2045-4038-19 www.marimex.de Marimex 03/11

ViscoScope VA-300X sensor The sensor for very high viscosities ViscoScope-Sensor Model VA-300X-ST with flange DN80 PN40 and non-active-extension (NAE) 44 x 100 mm / 1.75 x 4 The VA-300X (extra high viscosity) sensor with the mini-sphere is the ideal solution for extremely viscous fluids. This model can be calibrated up to 2,500,000 mpa s and, as such, is suitable for use, e.g. with very long-chain polymers and silicones. The sensor is primarily installed in pipe bends fitted with a non-active extension (NaE) in order to avoid no-flow zones and is often set up for high pressure. The process temperature is also measured at this location using a Pt100 temperature sensor, which is integrated into the sensor probe. This permits calculation of the temperature-compensated viscosity with a reproducibility of ± 0.5% taken. With extensive experience in this field, we will be happy to advise you on selecting the ideal instrument for your application. Typical Applications l Extruder l PIB l Extracts l Polymers l PET l Food l Silicon l Bitumen l Pharmaceuticals

Sensor Specification Sensor type VA-300X - mini sphere Viscosity range 100 2,500,000 mpa s x gr/cm 3 Calibration in 3 decades, option 4 decades Probe size ø 19 x 114 mm / ø 0.75 x 4.5 Material Protection Process temperature (Pt100 is integrated into viscosity probe) Process connection Flange Pressure Installation Resonance frequency Shear rate Cable length Sensor - Transmitter Speed of flow 1.4571 and 316L option: Hastelloy C22, Duplex 2205, teflon coating IP65 LT from -40 C to 130 C / -40 F to 270 F ST from -40 C to 300 C / -40 F to 570 F HT from -40 C to 450 C / -40 F to 840 F ST and HT with air cooling, dependend on installation Standard DN80 PN40 or ANSI 3 300# others on request Vacuum up to 450 bar / 6,500 psi Installation in any orientation in reactor, vessel, pipe, flow-through cell ~ 635 Hz ~ 4000 sec -1 maximum 1,000 meters / 3,330 feet up to 10 m / sec. or 33 feet / sec., dependend on installation Reproducibility ± 0,5% Accuracy ± 1% option: hazardous area ATEX: II 1/2 G EEx ia IIC T3 T6 option: non-active-extension (NAE) Eliminates no-flow areas in a pipe connection on a reactor, in a T-piece or flow-through cell. Can also be used to bridge gaps in open channel applications. Sizes on request. 265 mm 114 mm 151 mm ø 19 mm 113 mm Bergiusstrasse 6 Tel.: +49-(0)2045-4038-0 info@marimex.de 46244 Bottrop / Germany Fax: +49-(0)2045-4038-19 www.marimex.de Marimex 03/11

ViscoScope VA-300S sensor The sensor for special applications ViscoScope-Sensor Model VA-300S-ST with flange 1 2500#, non-active-extension (NAE) 25 x 100 mm / 1 x 4, Riser and shorter probe Sometimes process technology, applications or unusual mounting situations demand the design of the special sensor, the VA-300S (special) model. If it is technically possible, it can be accomplished with this instrument, e.g. shortened sensor probes, different sensor probe shapes, integrated or screw-on sensor protection, NPTthreads, special flanges and other customer-specific process connections. Our many years of experience put us in the ideal position to deal with new challenges and ideas, to understand the special requirements of your process and develop suitable solutions.

Sensor Specification Sensor type Viscosity range Calibration Probe size Material Protection Process temperature (Pt100 is integrated into viscosity probe) Process connection Flange Pressure Installation Resonance frequency Shear rate Cable length Sensor - Transmitter Speed of flow Reproducibility Accuracy VA-300S - dependend on construction 0.1 2,500,000 mpa s x gr/cm 3, dependend on construction in 3 decades, option 4 decades dependend on construction 1.4571 and 316L option: Hastelloy C22, Duplex 2205, teflon coating IP65 LT from -40 C to 130 C / -40 F to 270 F ST from -40 C to 300 C / -40 F to 570 F HT from -40 C to 450 C / -40 F to 840 F ST and HT with air cooling, dependend on installation Standard DN80 PN40 or ANSI 3 300# others on request Vacuum up to 450 bar / 6,500 psi Installation in any orientation in reactor, vessel, pipe, flow-through cell ~ 550 bis 635 Hz, dependend on construction ~ 3450 bis 4000 sec -1,dependend on construction maximum 1,000 meters / 3,330 feet short cable length recommended for very low viscosities up to 10 m / sec. or 33 feet / sec., dependend on installation ± 0,3% to ± 0,5% or dependend on probe type ± 1% or dependend on probe type option: hazardous area ATEX: II 1/2 G EEx ia IIC T3 T6 option: non-active-extension (NAE) Eliminates no-flow areas in a pipe connection on a reactor, in a T-piece or flow-through cell. Can also be used to bridge gaps in open channel applications. Sizes on request. VA-300S without flange, with O-ring groove and NAE VA-300S with custom-made flange, NAE and shorter probe VAsphere and 300S with big NAE Bergiusstrasse 6 Tel.: +49-(0)2045-4038-0 info@marimex.de 46244 Bottrop / Germany Fax: +49-(0)2045-4038-19 www.marimex.de Marimex 03/11