!!IERVICEB.aJC IJJI SQUARE D. Power Outlet Panels. Application Data Dimensions CONTENTS. Description Class Pages

Similar documents
5.2. Power Pedestals. Contents Description

6.2. Power Pedestals. Contents

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Contents. Volume 1 Residential and Light Commercial CA E December

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Air Conditioning Disconnects Molded Case Switch

MP Meter-Pak Meter Centers

Section 4 Square D QO Loadcentres

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

6.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

CON EDISON EQUIPMENT

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Selection and application guide

Volume 1 Residential and Light Commercial CA E December

Recreational Vehicle Park Electrical Products & Accessories

Fused Coordination Panelboard

PANELBOARDS C1/C2 SECTION 6

Heavy Duty Safety Switches

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Accessories. Accessories. Meter Mounting Equipment

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Effective December 2015 Supersedes September 2013

I-Line Circuit Breaker Panelboards Catalog 2110CT9701R02/ Class 2110

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

UNDERGROUND SERVICES - SECONDARY

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Engine Generator Circuit Breakers

SECTION PANELBOARDS

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Multiple Metering, Vertical Gang

Product Specification Sheet #3LD2.1

fastfax Rock Solid TM Load Centers General Information

Temporary Power Outlet Panels

QO and HOMELINE Circuit Breaker Load Centers and Enclosures

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Fused Coordination Panelboard

NQOD Circuit Breaker Panelboards

Laser Service Factory-assembled Panelboards

COMMERCIAL QUICK REFERENCE

Panelboards Circuit Breaker / Lighting and Distribution

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

QMB Fusible Panelboards

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Quick Connection Panel (QCP) Installation Guide

NQOD Circuit Breaker Panelboards

CANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Modular Metering. Canadian Version

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

A. Submit manufacturer's literature and technical data before starting work.

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Lighting and Power Distribution Panelboards

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

Multi-Pak Group Control

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

U075CTL A Surface 50/30/20GFCI Twin Lugs

Quik-Spec Coordination Panelboard A fusible panelboards

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

General Specifications for Lighthouse Power Pedestal

Indianapolis Power & Light Company

Quik-Spec Electrical Gear

Design Standard. Purpose: Design Standard:

Spring-loaded cover seats against neoprene gasket.

CIRCUIT BREAKER PANELBOARDS

MEG Approval Meter Equipment Group

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

Quik-Spec. Section Contents

10 Commercial, Industrial, Agricultural Services

GHN424NW HHN426N HUN361AW

Quik-Spec Coordination Panelboard A fusible panelboards

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

Bussmann series Quik-Spec Coordination Panelboard

Group Meter Main - Without Bypass

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Air Conditioning Disconnects

Dry-Type Transformers Mini-Power Centers

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Wisconsin Area Catalog

Transcription:

FILE: Distribution Product Catalog!!IERVICEB.aJC Power Outlet Panels CONTENTS Description Class Pages Application Data.......................... 1140........ 36 Dimensions................................ 1140........... 7 IJJI SQUARE D www. ElectricalPartManuals ElectricalPartManuals. com com

SQUARE SERVICEPAK power outlet panels are available with a variety of receptacle configurations to meet different job requirements. All receptacles are of the grounding type. Each nonpedestal mounted device has a bolton closing cap factory installed on the top endwall, and will accept bolton type "B" hubs. For bottom feeding from a conduit riser (except PAKl lc), the bottom endwall of all nonpedestal devices with box numbers and (see pages 3 and 5) have provisions to install a type "B" bolton hub. The NEMA Type rainproof enclosure is finished with gray PAK41CTG baked enamel, electrodeposited over cleaned phosphatized galvanized steel. The door has provisions to be padlocked closed. All receptacles and circuit breakers are included. All units (except PAK 11 C) are provided with cutouts in the bottom end wall so cords may remain connected when the door is closed. PAKll C receptacles are located in bottom end wall. Type SERVICEJ!.BK FOR CONSTRUCTION SITES AND FOR RECREATIONAL VEHICLE PARKS RECE P TACLE CONFIGURATION 20 Ampere 125 Volt 30 Ampere 125 Vott 50 Ampere 125/250 Volt 3W and Grd. 50 Ampere 250 Volt 2W and Grd. NEMA 650R 20 Ampere 250 Volt 2W and Grd. NEMA620R 30 Amp. 125/250 Volt 3W and Grd. NEMA 1430R FOR CONSTRUCTION SITES Provide temporary power at construction sites. Receptacles conform to NEMA configurations as specified by the National Electrical Code. Each receptacle protected by either a ground fault circuit interrupter or standard QO circuit breaker in compliance with NEC requirements. Each enclosure is rainproof. Service l02w l20vac 120/240Vac Mains Rating 40, 50, 60, or 100 ampere UL L isted Suitable for use as temporary site service entrance equipment under file E53303. Short Circuit Current Rating Suitable for use on systems having up to 10,000 RMS symmetrical amperes available short circuit current at 120/240Vac. Construction: 75 C wire rating (use of 90 C wire is permissible, but must be sized based on 75 C NEC table). Provided with neutral bonding provisions. 00, QWI KGARD and SERVICEPAK are Registered Trademarks of Square D Company. NEC is a Registered Trademark of National Fire Protection Association. IDI II All 20 ampere 125 volt receptacles are protected by QWI KGARD circuit breakers with ground fault circuit interrupter. PAK51C DOOR AND INTERIOR TRIM REMOVED D 3 www. ElectricalPartManuals ElectricalPartManuals. com com

SGUARE Ill Power Outlet Configuration mr GIGI GIGI GIGI T T "" Gl Gl []: Service Mains Ampere Rating Circuit Breaker (Included) 40 (1)Q0120GFI 40 (2)Q0120GFI 40 (2)Q0120GFI 100 (1)Q0120GFI (1)00230 (1)00220 (1)00250 (1)Q0120GFI (1)00250 5212 (2)Q0120GFI (1)00250 5212 (2)00250 5212 SERVICEH.BK FOR CONSTRUCTION SITES Main Wire Size Receptacles Catalog& AWGb. (Included) * Number Cu AI PAK10C1 11146 11126 NEMA520R PAK11C 11146 11126 NEMA520R PAK11C1 11146 11126 NEMA520R 30 Amp. 125/ 250 Volts PAK31C 1181 1181 3W and Grd. NEMA 1430R 20A. 250V. NEMA 620R NEMA520R PAK36C1 1181 1181 50A. 250V. 2W and Grd. PAK51C 1181 1181 NEMA 650R NEMA520R NEMA520R 50 Amp. 125/250 Volts PAK55C 1181 1181 3W and Grd. 50 Amp. 125/250 Volts PAK76C 1181 1181 3Wand Grd. 50 Amp. 125/250 Volts PAK1004C 11141 11121 3W and Grd. Receptacles in botto m endwall accessible with outer door padlocked. "Order only" from Lexingtonminimum order quantity is 50 devices. & All devices have bolton closing cap factory installed. Order Type "B" bolton hub separately. b. Ground terminal factory installed. Wire size 11144 AWG CU and 11124 AWG AL. * 20 ampere receptacles protected by 20 ampere GFI breaker. SERVICEPAK is a Registered Trademark of Square D Co mpany. 4 Box No. 1R PAK11C PAK55C INTERIOR ASSEMBLY PAK55C D ldl

Type Provides electrical power to individual recreational vehicle park sites. Receptacles conform to NEMA configurations as specified by the National Electrical Code. Each receptacle protected by appropriate ground fault circuit interrupter or standard QO circuit breaker in compliance with NEC requirements. Each enclosure is rainproof. Service 120Vac 120/240Vac Mains Rating 40, 50, 75 or 100 ampere Underground feed using conduit riser. Any unit can be wired for loopfeed. SERVICEf!.BK FOR RECREATIONAL VEHICLE PARKS PAK41CTG WITH DOOR AND INTERIOR TRIM REMOVED 00 and SERVICEPAK are Registered Trademarks of Square D Co mpany. NEG is a Registered Trademark of National Fire Protection Association. APPL ICAT ION DATA ULListed Suitable for use as recreational vehicle site service entrance equipment under File E53303. Short Circuit Current Rating Suitable for use on systems having up to 10,000 RMS symmetrical amperes available short circuit current at 120/240Vac. Construction CONSTRUCTION DETAILS IIJI SQUARED! 5 75 C wire rating (use of 90 C wire is permissible, but must be sized based on 75 C NEC table). No neutral bonding provisions. Loopfeed provisions. Pedestal cover is removable for easy accessiblity to wiring compartment. PAK61PG

Power Mains Outlet Service Ampere Conflg Rating uration Receptacles (Included) * SERVICEH.BK FOR RECREATIONAL VEHICLE PARKS Circuit Breaker (Included) Catalog Number Main Wire Size AWG/kcmil6 Phase and I Equipment Neutral Ground Cu I AI I UNDERGROUND OR OVERHE AD LOO PFEED TERMINALSNON PEDESTAL 1C 2C 40 40 3C 50 (2)00120GFI 30A. 125V. (1)00130 30A. 125V. 4C 50 (1)00130FI PAK10CTG PAK11CTG PAK41CTG PAK41CTGFI 30A. 125V. sc 75 (2)00130 PAK61CTG 6C 75 30A. 125V. (2)00130GFI... PAK61CTGFI PEDESTAL MOUNTEDUNDERGROUND LOO PFEED TERMINALS 9C 40 (2)00120GFI... PAK11PG 30A. 125V. 10C 50 (1)00130 PAK41PG 11C 50 30A. 125V. PAK41PGFI (1)00130GFI... 30A. 125V. 12C 75 13C 75 (2)00130 PAK61PG 30A. 125V. PAK61PGFI (2)00130GFI... 50A. 125/250V. 3W and Grd. 14C 100 30A. 125V. (1)00130 PAK75P G (1)002505212 50A. 125/250V. 3W and Grd. 15C 100 30A. 125V. (1)00130GFI (1)002505 212 PAK75PGFI Devices have a bolton factory installed closing cap. Order type "B"" bolton hub separately. Stabilizer footfor use in unstable ground. Order catalog number HNPSF. "' wires each per phase neutral, and equip ment groundfor loopfeed..a. "Order Only"not stocked in PDS. Order Point: Lexington. * 20 ampere receptacles protected by 20 ampere GFI breaker. 00, OWIKGARD and SERVICEPAK are Registered Trademarks of Square D Co mpany.... Cu I AI #146 #126 #102/0 #62/0 #146 #126 #102/0 #62/0 #146 #126 #102/0 #62/0 #146 #126 #102/0 #6210 #141 #121 #102/0 #6210 #141 #121 #102/0 #62/0 50A. 125/250V. 3W and Grd. 7C 100 PAK75CTG 30A. 125V. (1)00130 (Not loop feed) (1)002505212 #141 #121 #102/0 #62/0 50A. 125/250V. 3W and Grd. PAK75CTGFI BC 100 30A. 125V. (1)00130GFI (Not loop feed) #141 #121 #102/0 #62/0 (1)002505212... (2) #6250 (2) #6250 (2) #6250 (2) #6250 (2) #6250 (2) #6250 (2) #6250 (2) #102/0 Cu (2) #102/0 Cu (2) #102/0 Cu (2) #102/0 Cu (2) #102/0 Cu (2) #102/0 Cu (2) #102/0 Cu Box No. 3C 1111[;][;] 2C 4C 7C BC TT (jj TT 9C 10C 11C 12C 13C [J = [J = 14C PEDESTAL LOOPFEED LINE AND GROUND TERMINALS STABILIZER FOOT HNPSF 15C!! PEDESTAL MOISTURE BARRIER HOLE PLUGS ARE PROVIDED FOR LAST DEVICE USED ON A LOOP FEED CIRCUIT 6 SQUARED IIJI

SQU 62 BOX1R 2'h''HUB MAXIMUM (2) #6 AWG250 kcmil Per Phase & Neutral (2) #102/0 AWG Cu (2) #62/0 AWG AI Equipment Ground Lugs SERVICEH.BK FOR CONSTRUCTION SITES AND FOR RECREATIONAL VEHICLE PARKS PEDESTAL MOUNTED Conduit Size Hub Catalog No. SERV ICEPAK is a Registered Trademark of Square D Company. IIJl DIMENSIONS BOX 2'h''HUB MAXIMUM BOLTON HUBS UL LISTED Catalog Number A B c BOX 2'h''HUB MAXIMUM DIMENSIONS (Inches/Millimeters) Symbol A B 2%" 8250 II PAK11PG PAK41PG PAK61PG PAK61PGFI PAK41PGFI PAK75PG PAK75PGFI 8.63/219 16.43/421 34.50/876 42.31/1083 59.50/1511 67.30/1723 KNOCKOUT TABLE V2'' %" X X Conduit Size 1" 1%" 1Y2'' 2" 2V2" X X X X X Dual Dimensions: INCHES Millimeters RED 7

Order No. 1140CT9201 (Replaces 1140CT9101) Printed in the U.S.A SQUARED 1992 Square D All Rights Reserved