High Power Switchgear. We can create a solution that s both effective and cost-effective

Similar documents
High Power Switches. Expertly engineered for reliable performance. L High Power Switches

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

DBM Range 1500VDC (13,5kA to 20kA)

Disconnectors FA range 750VDC 250 to 2000Amp

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Disconnectors FA range 1500VDC 250 to 2000Amp

Disconnectors MF range (0,5 to 3000 Hz) (1250 to Amp)

Gas Insulated Switchgear

High-Voltage Fuse Links according to IEC

RAPIER DSB Disconnectors

Modulostar. Motor Branch 400V AC - 690V AC up to 11 kw

Euroload Changeover Switch

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

NH Solid Blades 690 VAC sizes 000 to 3

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Horizontal Circuit Switchers

Horizontal Circuit Switchers

DMX 3 -I 2500 switch disconnectors

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Extensible Unit - VCE2a

S w i t c h e s. Disconnectors LTHM/P-U/D line LTMP line. Contactors LTHS line LTC line LTHH/LTE/LTP line LTNS line N line

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Outdoor vacuum breaker for railway applications - FSK II

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

B kv Gas-insulated Substations

HD4. Gas insulated MV circuit-breakers kv A ka

Padmount Solid Dielectric Switchgear Catalog

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Fused Coordination Panelboard

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

F-Series. Circuit Breaker

Cobra-S. Catalog Cobra-S

Gas Insulated Metal-clad Switchgear, HMGS!

F-Series. Circuit Breaker

Publication No.: PSG

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Medium Voltage Metal-Enclosed Switches

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Section 2 - Substation Switchgear

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

TECHNICAL SPECIFICATIONS

Vacuum Circuit Breaker VS1

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Transmission Switching

FR circuit breaker - hydraulic magnetic,

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

NRB Disconnector for outdoor installation

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

RPS Plus switchgear. Introduction & overview September 2013

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

OPTIONAL. Active Arc Eliminator - Safest in the world

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

3TM Vacuum Contactors

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

BETA Switching Switches and Light Indicators

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Auxiliary Relay. Type RXP8n, RXPQ8n

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Accelerate your grid modernization with smart RMUs. Ring main units with smart grid-ready feeder automation

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

Elimsan High Voltage Disconnectors

Semiconductor (AC) fuses

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB

ULTRASAFE Fuse Holders The safety evolution continues.

Low & Medium Voltage Vacuum Contactors

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

Disconnectors and earthing switches For applications from 72.5 kv to 420 kv

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Independent Testing Laboratory for High Voltage Equipment

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Medium Voltage Metal-Enclosed Switches

PIX-H Metal-clad switchgear up to 17.5kV

Disconnectors and earthing switches up to 25 kv AC

AF series contactors (9 2650)

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Modular medium-voltage switchgear. NorMax

Transcription:

High Power Switchgear We can create a solution that s both effective and cost-effective

Switch Application Questionnaire Customer: Address: State/Zip: Contact: Project Name: Electrical Data Switch to operate: ON OFF LOAD Operating Voltage: AC: Volt O Hz Number Poles DC: Volt L/R (DC), Number Poles Full Load Current Amp. (If variable, attach duty cycle) Overload Current Amp Peak Withstand Current ka Dielectric Withstand (1min) kv Rated Impulse Voltage BIL kv Rated short-time withstand current ka Note: Please indicate if items C-E are expected to be interrupted Mechanical Data Disconnect Changeover Pole Reverser Isolator (1-0) Open switch Isolator (1-M) M: Ground Date: Phone: Fax: e-mail: 2 Positions Changeover (1-2) 3 Positions Changeover (1-0-2) Note that Mid-Point is OFF. 3 Positions Changeover (1-M-2) Note that Mid-Point is ground For reversing current inside Cells, such as Mg. Cells Number of Poles: Connections by Cables, Number of cables per phase, Lugs, bolted Busbar, Number of bars per Bus Welding Size: (H) (S) Bus Type: Copper Aluminium Others Accessories Operation:Motorized Manual Pneumatic Motor VAC. - Hz VDC Provision for Lockable handle Number of Auxiliary Contact (NO+NC) per position Interlock System Quantities Date required by Annual Usage Environnment Outdoor Indoor Application Comments or special insructions Your contact: Please attach a sketch and sequence of operation.

APPLICATION When industry-leading compagnies worldwide have a special challenge, they call Ferraz Shawmut. Why? Because we ve pioneered more technological advances in high-power switches than all of our competitors combined with three Ferraz Shawmut brands: Fouilleret Berg Soulé A deformable disconnect switch that can move on three axes to allow for bus bar expansion, eliminating the need for expensive flexible connections. A proven air-cooled switch for aluminium smelting - the first of its kind. The first input loadbreak disconnect switch for choppers - DC-to-DC converters used in chloralkali applications. The first loadbreak switch and rotating current transfer unit for copper foil process. The first dual-shell switching system for DC arc furnaces. DC and AC switch designs to handle high current/low voltage and high voltage/low current applications, include Rectifier output disconnect switches. Change-over disconnect switches. Change-over grounding disconnect switches. Polarity-reversing disconnect switches. Distribution panel disconnect switches. Low-voltage disconnect switches. Medium-voltage disconnect switches. Grounding switches. Mobile and stationary shorting switches. Pure silver-to-silver contacts for the best connection. A visible disconnect that eliminates guesswork and increases safety. Self-cleaning contacts for minimal maintenance. Aluminium or copper, bolted or welded connection. Various methods of operation - manual, electric or pneumatic. Mechanical or electrical open-switch locks. Multiple contacts, with spring-loaded arc-quenching chambers independent from the main contacts on load break switches. Outdoor enclosures resistant to corrosive environments

CHEMICAL, METAL PROCESS A range of switches, from transformer to cell High-power chemical processes, like electroplating and the electrolysis of chlorine, fluorine and magnesium, require disconnect switches that can handle 300 ka plus. Ferraz Shawmut offers these as well as a range of other types of switches, to cover the entire line from transformer to cell. In fact, we were the first to create multiple products for specific applications. Switches are available for flexible or fixed connections - copper or aluminium, bolted or welded. They include: Medium-voltage transformer disconnect switches. Rectifier output disconnect switches. Mobile and stationary shorting switches. Polarity-reversing disconnect switches for electroplating. High-Current Disconnectors NORD Type 1500 V DC - 14 ka to 140 ka Single pole / Double pole / Change-over Aluminum or Copper Terminals Very High Power Disconnectors PBD (Plain Bars Disconnectors) Type 2000 V DC - 20 ka to 160 ka Single pole / Double pole / Change-over Aluminum Terminals Hgh-Current Disconnectors MBD (Multi-Blade Disconnectors) Type 2000 V DC - 5kA to 60 ka Single pole / Double pole / Change-over Aluminum or Copper Terminals Few applications are as extreme as metals processing. Whether it involves arc furnaces or induction ovens that reach over 300 ka, rolling mills or the electrically charged drums used to create foils, metals processing poses formidable challenges to circuit protection.

TRACTION APPLICATION If you ve traveled by train anywhere in the world, chances are Ferraz Shawmut s high-power switches were part of trip. Built to take the vibration and constant punishment of traction applications, our AC and DC switches are found everywhere - from light rail and subway trains to locomotives, from substations and rolling stock to third rails. Customers rely on us for: High Current Disconnectors Change-over disconnectors FA Type 3000 V ~ / = 500-8000 A 0-175 HZ Change-over disconnectors on board FA Type Substation switches: DC change-over switches. DC grounding switches. AC medium-voltage disconnect switches. Rolling stock switches: AC and DC disconnect switches. AC and DC change-over switches with several poles and several positions, to handle main, shop, auxiliary and other sources of power. Track and main yard switches: Catenary and third-rail switches. Loadbreak disconnect switches to sectionalize track. The switches can be operated manually, or they can be motorized and operated locally or remotely, increasing safety and reliability. Another safety feature is a built-in interlock that ensures the position of the switch. DC Loadbreak Switches IF Type 1000 V DC - 800 to 6300 A

MEDIUM VOLTAGE So whether your needs are simple or complex, you can rely on Ferraz Shawmut to deliver the best solution. To learn more, call us. We ll show you all the ways we re your circuit protection resource. HAS Type 12 kv, 24 kv, 36 kv 400 A to 1 000 A - up to 175 Hz Number of poles : 1, 2, 3, Distribution panel disconnect switches. Low-voltage disconnect switches. Medium-voltage disconnect switches. Grounding switches. Mobile and statinary shorting switches. HAS Type 1.6 ka to 6.3 ka - up to 175 Hz Number of poles: 1, 2, 3, Equally important, we possess the ability to listen. An ability that enables us to truly understand your operation and your needs, so we can create a high-power switch solution that s both effective and cost-effective. ETM Type 3.6 kv, 12 kv, 24 kv, 36 kv Number of poles : 1, 2, 3, HAS Type 12 kv, 24 kv, 36 kv 1.6 ka to 6.3 ka - up to 175 Hz Number of poles: 1, 2, 3, Large isolation air and creepage path Self-cleaning blade contacts True opening and visible break Rugged anti-torsion construction Large customisation with : Manual, motor, pneumatic drives Auxiliary switches, solenoid interlocks According to IEC 62 271 Dimensions Adaptable

DESIGN AND DEVELOPMENT Innovating to meet customers' needs To maintain its leadership on the traction market, Ferraz Shawmut makes the most of the synergies offered by its Test Center, dedicated to innovation and quality. Products run the full gamut of tests thereelectrical, climatic, mechanical - static, dynamic, endurance, wear - under the harshest conditions possible, before final assembly. From the very outset of a project, Ferraz Shawmut works with the builders and operators of the traction system to study the best solutions to meet their requirements. Ferraz Shawmut, a division of the Carbone Lorraine group, is the world's reference in circuit protection. On the strength of that position, and long experience with electrical contacts, the company offers a range of equipment for railway traction applications. Its strong presence around the world brings it close to its customers wherever they are, and helps it to tailor products to their needs. In close collaboration with customers' design and engineering departments, Ferraz Shawmut has developed specific know-how, working methods and organizational structure, with the goal of constantly proposing new solutions. Ferraz Shawmut offers you: a team of experts working with design software to better optimize your equipment exceptional product performances great flexibility to adapt to the specific characteristics of your applications.

Switch Application Questionnaire OTHER FERRAZ SHAWMUT ACTIVITIES Innovating to meet customers' needs High Power Switchgear BOGIE PROTECTION THERMAL MANAGEMENT Ferraz Shawmut, a division of the Carbone Lorraine group, is the world's reference in circuit protection. Customer: Address: State/Zip: Contact: Project Name: Date: Phone: Fax: e-mail: Electrical Data Switch to operate: ON OFF LOAD Operating Voltage: AC: Volt O Hz Number Poles DC: Volt L/R (DC), Number Poles Full Load Current Amp. (If variable, attach duty cycle) Overload Current Amp Peak Withstand Current ka Dielectric Withstand (1min) kv Rated Impulse Voltage BIL kv Rated short-time withstand current ka On the strength of that position, and long experience with electrical contacts, the company offers a range of equipment for railway traction applications. Its strong presence around the world brings it close to its customers wherever they are, and helps it to tailor products to their needs. Metro cooling application Note: Please indicate if items C-E are expected to be interrupted CIRCUIT PROTECTION Mechanical Data Disconnect To maintain its leadership on the traction market, Ferraz Shawmut makes the most of the synergies offered by its Test Center, dedicated to innovation and quality. Products run the full gamut of tests there- electrical, climatic, mechanical - static, dynamic, endurance, wear under the harshest conditions possible, before final assembly. Isolator (1-0) Open switch Isolator (1-M) M: Ground Changeover 2 Positions Changeover (1-2) 3 Positions Changeover (1-0-2) Note that Mid-Point is OFF. 3 Positions Changeover (1-M-2) Note that Mid-Point is ground Pole Reverser From the very outset of a project, Ferraz Shawmut works with the builders and operators of the traction system to study the best solutions to meet their requirements. We can create a solution that s both effective and cost-effective Your contact great flexibility to adapt to the specific characteristics of your applications. Headquarters: 1, rue Jean Novel F-69626 Villeurbanne Cedex - France Tel. +33 4 72 22 66 11 - Fax +33 4 72 22 67 13 Industrial & Sales Facilities: Ferraz Shawmut 1, Chaussée de la Comtesse F-77160 Provins - France Tel. +33 1 60 58 56 20 Fax +33 1 64 08 88 34 Ferraz Shawmut Inc. 374 Merrimac Street Newburyport, MA 01950 - USA Tel. + 1 978 462 66 62 Fax + 1 978 462 01 81 Ferraz Shawmut GmbH Käfertaler Strasse 226-228 D668167 Mannheim - Germany Tel. +49 621 338 66 00 Fax +49 621 338 66 50 Ferraz Shawmut Canada Inc. 88, Horner Avenue Toronto Ontario M8Z 5Y3 - Canada Tel. + 1 416 252 93 71 Fax + 1 416 252 92 45 www.ferrazshawmut.com DISCOM +33 (0)4 37 65 40 43 - Issue 09/2004 - Ref: HP001 Ferraz Shawmut offers you: exceptional product performances Connections by Cables, Number of cables per phase, Lugs Busbar, Number of bars per Bus Welding Size: (H) (S) Bus Type: Copper Aluminium Others, bolted Accessories Operation:Motorized Manual Pneumatic Motor VAC. - Hz VDC Provision for Lockable handle Number of Auxiliary Contact (NO+NC) per position Interlock System In close collaboration with customers' design and engineering departments, Ferraz Shawmut has developed specific know-how, working methods and organizational structure, with the goal of constantly proposing new solutions. a team of experts working with design software to better optimize your equipment For reversing current inside Cells, such as Mg. Cells Number of Poles: Quantities Date required by Annual Usage Environnment Outdoor Indoor Application Comments or special insructions Please attach a sketch and sequence of operation. Your contact: DESIGN AND DEVELOPMENT