CM 5000D IN A HURRY?

Similar documents
1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

3143 Production Drive Fairfeild, Ohio Model HA-45. Installation and Service Manual

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

ANALOG CONTROL PANEL

APOLLO Gate Operators, Inc.

MODEL 422 Submersible Pump Controller

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

6500DC Dual Motor Wireless Controller Kits

2. There are 2 types of batteries: wet cells and dry cells.

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

APOLLO Gate Operators, Inc.

30A SMART ENERGY MANAGEMENT SYSTEM TM

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

Electrical Components

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

Quickie Rhapsody Service Manual

The Da-Lite Difference.

SYSTEM OPERATION IMPORTANT CAUTIONS

Solstice Electric Fryers SE Series Service Manual

PAGE Both power cords must be connected & powered to operate the E-TES 120.

MODEL H INSTALLATION INSTRUCTIONS

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Battery Backup Sump Pump System Instruction Manual

User s Manual. Automatic Switch-Mode Battery Charger

P80074 (150 amp connectors) P80071 (300 amp connectors)

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INTELLIQUILTER INSTALLATION ON APQS MILENNIUM/FREEDOM/ULTIMATE-I VERSION

The POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.

Crane Systems GREER COMPANY. LALT 1151L System for Lattice Cranes. Installation and Calibration Manual. 1 of 39

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

ELECTRO-MECH SCOREBOARD CO.

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

3 Slot Payphone Controller

The Da-Lite Difference.

Owner s Manual POWER SOLUTION. AUTOMATIC CIRCUIT SWITCH. JTB Manufacturing, Inc. Part No Manufacture Date Year: 2013 Month:

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

Instruction Book for. ContouR ElECtRol

Quickie S-11 Service Manual

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

Application Engineering

Electro-Mechanical Swing Operator. Table of Contents

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

APOLLO Gate Operators, Inc.

Electrical Systems. Introduction

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

AUTOMATIC SPRINKLER TIMER

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

Sensors W2 and E2 are optional. Installation guide, 'Pickle Fork' Back-and-Forth Model Train Controller

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Thunder Power Tarp Kit Operation

HD 7700 Setup & Operator Manual

MODEL ELC-12/40-CVM-D BATTERY CHARGER

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Application Engineering

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

Installation Operation Parts

Electricity. Teacher/Parent Notes.

7.9.8 Elctromagnetism

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

DOOR SAFETY KIT INSTALLATION MANUAL

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

Electric Actuator Instructions

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Model: SE-4020-CA Automatic Battery Charger

Application Engineering Europe

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

AUTOMATIC DUST COLLECTION FOR SMALL SHOPS INSTRUCTIONS GG500C MOTOR CONTACTOR WITH THERMAL PROTECTION 220VAC COIL

INTELLIQUILTER INSTALLATION ON A-1 MACHINES VERSION

Fan Coil Unit (FCU) Fan Motor Control

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Combined Ventilation Controller RVWS-T-224HA

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Circuit Training. A Selection of Simple, Fun Electronic Projects using the Electricity Box provided with the Heather's Hut project

General Description. Product Specification. Document Digital Temperature Interlock

Installation and Construction Notes for EVSE4

ELECTRICAL SYSTEM UPGRADE

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Instruction Manual for the. E-SL 450 Series

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

MODEL 9520 & 9520GS 6/12 VOLT, 0-20 AMP - BATTERY CHARGER OWNER'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

Fast Charge Option (IEC 335) MegaPulse Surge Testers

BIRD FEEDER ELECTRIC RETRIEVER CONTENTS

INSTRUCTIONS FOR A

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Measurement and Analysis of the Operation of a Single-Phase Induction Motor

Transcription:

CM 5000D Conventional and Tunnel Instructions IN A HURRY? Flip to Pages 6-13 for Wiring Diagrams 4-11.

Investigate The REEL-FREE Winch Handle The REEL-FREE Winch Handle adds features to your curtain winching system THE WINCH PICTURED IS AN EXISTING WINCH. THE ORIGINAL HANDLE WAS REMOVED AND REPLACED ON THE FARM WITH THE NEW REEL-FREE HANDLE THE WINCH KIT HOLDS THE CORD, WHICH CONNECTS TO THE WINCH HANDLE. THE HANDLE CANNOT GO PAST THE TWO O CLOCK POSITION WHEN RELEASED. THIS MAKES THE HANDLE SAFER. THE REEL-FREE HANDLE OPERATES THE WINCH SIMILAR TO THE ORIGINAL HANDLE UNTIL DISENGAGED. THE CURTAIN-MINDER GETS BETTER The REEL-FREE winch handle drops curtains quickly without tangling the curtain cables. It winds up curtains similar to the standard handle. When the handle is in control, the curtains can be adjusted. When the handle is released, the reel is free to turn releasing the cable in 2 seconds. Since the handle hardly turns, the handle presents little danger to the operator and losing the string is lessened. The REEL-FREE handle retrofits most winches so a new winch is not required. The curtain drop does not have to be replaced. 1

*****CM 5000D CURTAIN-MINDER INSTRUCTIONS***** 1- Unpack your CM 5000D Curtain-Minder. Remove the transformer and the winch kit. 2- The transformer mounts on a 7/8" knock out of a junction box, handy box, or breaker panel. It is best to wire the primary wire leads of the transformer to a fan power supply circuit, preferably the workhorse fan breaker. 3- Mount the CM 5000D Curtain-Minder on the wall so the white wires will reach the transformer. Connect the white lamp cord from the 24 VAC terminals of the Curtain-Minder to the screw terminals on the transformer. Apply power to the unit and see that the AC POWER light is on. Disconnect the power and continue the installation. 4- You have two reliable choices for installing the Winch Kit(s). The parts are included for both. (A) The DIRECT-CONNECT method (Page 7, Figure 1A), eliminates the loss of the braided cord with the handle hook. The cord is tied above and to one side of the winch kit so the winch kit can swing out of the way of the winch handle. To operate, the winch kit is closed so the hinge meets the blue electro-magnet. The string loop (with the HANDLE HOOK) is draped over the hinge. Make sure the loop drapes over the knuckle of the hinge and does not make contact with the tilt screw. Now let the winch handle cradle in the handle hook. You may prefer to crimp the handle hook to the winch handle to prevent it from getting lost. (B) The ORIGINAL method (Page 7, Figure 1B) provides good holding power, especially when curtain machines are used. Mount the winch kit on a mounting surface as near the winch handle as possible, using the holes in the top of the plate. The hinge, when open, should point toward the winch handle. Make sure the tilt screw is in enough for the hinge to contact the magnet. Remove the handle hook from the short loop by cutting or untying the cord. Cut a piece of PVC pipe nearly as long as the cord. Thread the looped end of the cord through the piece of PVC pipe. Refer to Figure 1B. Drape the looped end of the braided cord over the hinge so that it rests at the knuckle of the hinge. Keeping the cord as short as possible, tie the handle hook on the other end of the cord and cradle the winch handle in the handle hook. Remove the ratchet on the winch! Now the winch kit is carrying the weight of the winch handle. When you positively do not want to release the winch handle, let the hinge hang down and connect the looped end of the cord to the tilt screw. 5- You should use 18-gauge two-conductor lamp cord to make all of your connections. Other wire may not be as satisfactory in the long run. 6- There are six terminal blocks with four screw terminals each on the right side of the front door for all of the wiring connections. The terminal blocks can be unplugged for easy access. The second through the fifth terminal block is used to wire the winch kits. The fifth terminal block is labeled Magnet 1 and the second terminal block is labeled Magnet 4. There is no particular order for numbering the winch kits. The CM 5000D will accommodate up to five winches. There is a small yellow screwdriver included for making the connections. Please leave the screwdriver inside the Curtain-Minder! 2

(a) Wiring for ONE Winch Kit (Page 10, Figure 4) Extend the magnet wires on the Winch Kit to the Curtain-Minder using 18-gauge lamp cord. Connect the other end of the lamp cord to the bottom screw labeled Magnet 1 and the top screw labeled Magnet 4. The reed switch wires should be wired to the Normally Closed circuit on an alarm such as our MARK 220. (b) Series Wiring for TWO Winch Kits (Page 10, Figure 5) Extend the magnet wires on two Winch Kits using 18-gauge lamp cord. Connect one wire from each Winch Kit together. The other end connects to the bottom screw labeled Magnet 1 and the top screw labeled Magnet 4. (c) Series Wiring for THREE Winch Kits (Page 11, Figure 6) Extend the magnet wires on three Winch Kits using 18-gauge lamp cord. Connect one wire from each Winch Kit together. A wire from the 1 st Winch Kit connects to the bottom screw labeled Magnet 1 and a wire from the 3 rd Winch Kit connects to the top screw labeled Magnet 4. (d) Series Wiring for FOUR Winch Kits (Page 11, Figure 7) Extend the magnet wires on four Winch Kits using18-gauge lamp cord. Connect one wire from each Winch Kit together. A wire from the 1 st Winch Kit connects to the bottom screw labeled Magnet 1 and a wire from the 4 th Winch Kit connects to the top screw labeled Magnet 4. NOTE: A warning label is included with each winch kit. For safety, attach it near the curtain winch. Being near the winch can be very hazardous, so STAY CLEAR! 7- The CM 5000D has a relay with a dry contact that can be tied to your alarm to tell you when the unit has detected low power. There are three terminals at the top of the board (see Figure 3) for this output. The alarm can be wired Normally Open (NO) or Normally Closed (NC). 8- Remove the green paper from the double-sided tape in the back of the unit and set the battery on the tape. Connect the 12-volt lead acid rechargeable battery to the RED and BLACK wires being sure to observe polarity. 9- Close the unit, reconnect the power to the unit, set the desired time delay and you are ready to connect the winch handles. 10- A very nice feature of the CM 5000D is that you can test the Curtain-Minder with a short time delay. Set the timer knob to 1 and remove the power from the circuit being monitored. The Low Power/Timing light should be blinking and the curtains should drop. After testing, be sure to set the knob to your desired delay time and reconnect the winches. NEW TO THE CM 5000D Please follow these suggested wiring instructions when you are using the WK 1510 winch kit for Automatic Tunnel Mode. We recommend using 4-conductor 18-22 gauge wire. (1T)- Open the unit and set the DIP switch for the number of winches you are using. The DIP switch is located on the left hand side of the board. Push the switch or switches up for each winch being used. The switches on the next page show the selection for 1, 2, 3 or 4 winches. 3

1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 (2T)- If you use fewer than 4 winch kits, it is necessary to put a jumper between the two terminals for each reed switch that is not used. You will need to cut a piece of scrap-stranded wire about 3 inches long and strip it on both ends. See the wiring diagrams on pages 11 and 12 for the correct locations of the jumpers. (A) Wiring ONE WK 1510 in Automatic Tunnel Mode (Page 12, Figure 8) Using the black and white conductor of 4 conductor 18-22 gauge wire extend the reed switch wires. Connect the other end of the black and white wires to the 2 screws labeled Reed Switch 1. Extend the magnet wires with the red and green conductor. Connect the green wire to the bottom screw labeled Magnet 1 and connect the red wire to the top screw labeled Magnet 4. (B) Wiring TWO WK 1510 in Automatic Tunnel Mode (Page 12, Figure 9) Using the black and white conductor of 4 conductor 18-22 gauge wire extend the reed switch wires. Connect the other end of the black and white wires to the four screws labeled Reed Switch 1 and Reed Switch 2. Extend the magnet wires with the red and green conductor. Connect the green wires to the bottom screws labeled Magnet 1 and Magnet 2. Connect the red wire of the 1 st to the bottom screw of Magnet 1. Connect the red wire of the second magnet to the top screw of Magnet 4. (C) Wiring THREE WK 1510 in Automatic Tunnel Mode (Page 13, Figure 10) Using the black and white conductor of 4 conductor 18-22 gauge wire extend the reed switch wires. Connect the other end of the black and white wires to the six screws labeled Reed Switch 1, Reed Switch 2 and Reed Switch 3. Extend the magnet wires with the red and green conductor. Connect the green wires to the bottom screws labeled Magnet 1, Magnet 2 and Magnet 3. Connect the red wire of the 1 st and 2 nd magnet to the top screws labeled Magnet 1 and Magnet 2. Connect the red wire of the 3 rd magnet to the top screw labeled Magnet 4. (D) Wiring FOUR WK 1510 in Automatic Tunnel Mode (Page 13, Figure 11) Using the black and white conductor of 4 conductor 18-22 gauge wire extend the reed switch wires. Connect the other end of the black and white wires to the eight screws labeled Reed Switch 1, Reed Switch 2, Reed Switch 3 and Reed Switch 4. Extend the magnet wires with the red and green conductor. Connect the green wires to the bottom screws labeled Magnet 1, Magnet 2, Magnet 3 and Magnet 4. Connect the red wire of the 1 st, 2 nd and 3 rd magnet to the top screw labeled Magnet 1, Magnet 2 and Magnet 3. Connect the red wire of the 4 th magnet to the top screw labeled Magnet 4. 11- To test the battery set the timer knob to 2 minutes or more then push the battery test switch up and hold for 15+ seconds. If the Timing light blinks and the magnets hold, the battery is good. If the magnets drop, your battery needs to be replaced. Make sure you replace the battery with a 12-volt sealed lead acid rechargeable battery that is at least 2.5 amp hours. 12- An extra safety feature is also on the board. If for some reason, the curtains have not dropped in the amount of time you have set on the CM 5000D, after 10 minutes the circuit dies and the magnets release. 4

A CONFESSION We at Pro-Tech, Inc. have done our best to build your Curtain-Minder free of defects. However, we are human; therefore, your Curtain-Minder was subjected to human error. Please test the Curtain-Minder thoroughly and frequently. We promise the Curtain-Minder will fail. We hope it does not fail in your lifetime. When it fails, it will likely fail when you need it most. Please remember that Terry Allen and Jim Sutton designed this product so anything is possible! 13- A back-up high temperature thermostat can release the curtains or windows. The best way is to connect a Ther-Minder, by Pro-Tech, Inc. to the Curtain-Minder using the NC instructions in Fig. 2b on page 7. Another way to achieve this is to connect a cooling thermostat, NO contacts, which can also be the Ther-Minder shown in Fig. 2a on page 7. When the low power light blinks, the alarm relay energizes. If the alarm relay is wired to an alarm, you should be notified. 14- The CM 5000D Curtain-Minder is the most fail-safe Curtain Release device available. The CM 5000D will release curtain winches upon power outages and low voltages. If the Curtain- Minder releases the curtain winches upon low voltage, the LOW POWER light will be blinking or on if, the unit has timed out. You have made a wise purchase; however, the CM 5000D Curtain-Minder is only a management tool and NOT an insurance policy. It does not replace the attendant or make a poor attendant a good one. For MAXIMUM PROTECTION, make sure that: (A) The ratchet is removed. (B) The weight of the winch handle is sufficient to flip the hinge completely down. (C) The curtains will fall when the winch handle is released. NEED MORE STRENGTH? There are two ways: (1) The Winch Kit has a yellow dot on the part of the magnet, which holds the hinge. This dot reduces the holding power of the Winch Kit. You may remove this yellow dot with your fingers and increase the strength. Please test the unit to see the Winch Kit(s) turn the winch loose, as you would expect. (2) For use with Curtain Machines to make the Curtain-Minder heavy duty (Double holding power): See (Figure 3, page 8) and do the following: (A) Open the door to the Curtain-Minder. (B) Locate J4 to the left of the terminals for wiring Magnet 4. There is a "shorting jumper connecting the middle pin and the lower pin. (C) Remove the "shorting jumper" and put the "shorting jumper" on the middle pin and the upper pin. Note: We are asked occasionally if one transformer can operate both the Curtain-Minder and the Mark 220 Alarm. The answer is yes if you use the transformer that comes with the Mark 220 Alarm. Both transformers have the same input and the same output. The Mark 220 has twice the amperage, so it is bigger and heavier. The alarm transformer is rated at 40 VA while the Curtain- Minder transformer is rated at 20 VA. 5

Connections for a CM 5010D to be used as a stand alone alarm system Normally Open Contacts To Can Monitor High/Low Trip Siren Temp, Water Pressure, or any Normally Open Device. OPER. LED TRIP RETURN OPER. OUT 1 2 3 4 zones DD-3E DIGITAL DIALER 6-16 VDC + _ R EG T TD RD House Phone Jumper wire from +12V to Common 2 Amp Min @12VDC Siren Phone Line connection ON / OFF Switch For Dialer & Siren Siren will alarm when curtains fall or Power Fail. 4 Cond Wire to each WK 1510 4 Cond Wire from Curtain-Minder to each WK 1510 4 Cond Wire to each WK 1510 Set the DIP switch like this for 4 winch kits in tunnel mode. 4 Cond Wire from Curtain -Minder to each 1 2 3 4 WK 1510 6

7

8

Figure 3 You can monitor low AC or no AC power by wiring your CM 5000D into your alarm system. Connect the alarm contacts labeled COM and either the N/C or N/O terminal to your alarm system. The N/C is used for Normally Closed and the N/O is used for Normally Open. You can make the winch kits stronger by moving J4 to the top 2 pins when no more than 4 Winch Kits are used. DIP Switches 9

10

11

12

13