A70, A72 Series Temperature Controls for Refrigeration and Heating

Similar documents
P20, P21 Series Air Conditioning Limit Controls

P70 Series MICRO-SET TM Pressure Controls for Refrigeration and Air Conditioning, 4-Wire, 2-Circuit Contact Block

P10 Series Low Range Pressure Controls

400 VMC Series. Compressor Manual Models: 440, 450, 450XL, and 460. Manufacturers of Industrial Refrigeration and Gas Compression Equipment

A25 Series Warm Air Control with Manual Reset

P70, P72, and P170 Controls for Low Pressure Applications

P70, P72, and P170 Series Controls for High Pressure Applications

P445 Series Electronic Lube Oil Control

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

P70, P72 and P170 Series Controls for High Pressure Applications

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

M9220-xxx-3 Electric Spring Return Actuators

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing

M9210-xxx-3 Electric Spring Return Actuators

A11 Series Low Temperature Cutout Control

P66 Series Electronic Fan Speed Controls

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

Series Y63, Y64, Y65, Y66, and Y69 Transformers

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

System 350 P352AB Electronic Pressure Control Series

System 350 S350C Temperature Slave Stage Module

RD-2000 Round Control Dampers

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

R81EAA-2 Economizer Circuit Board

VA-4233-GGx Series Electric Valve Actuators

F261 Series Fluid Flow Switches

M100F Incremental Motor Actuator R81F Interface Board

M9300 Series Electric Non-Spring Return Actuators

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

P77 Series. Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications. Product Bulletin

Series P74 Differential Pressure Controls, without time delay

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9216 Series Electric Spring Return Actuators

P545 Series Electronic Lube Oil Control

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

System 350 S350P Proportional Plus Integral Temperature Stage Module

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

V-2410 Three-Way Multipurpose Solenoid Air Valve

RA-2000 Airflow Measuring System

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

M9000-3xx Series Weather Shield Enclosures

M9109 Series Electric Non-spring Return Actuators

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Powers TM Controls SW 141 Differential Static Airflow Switches

Pressure Control Type KPU

V46 Series Pressure-Actuated Water-Regulating Valves

R-317 Air Flow Controller

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

VSD Series II Variable Speed Micro Drives

TE-6300 Series Temperature Sensors

I ntroduction. N ote. Series P74 Differential Pressure Controls, without time delay. Feature and Benefits

N-1001 Economizer Logic Network

Remote Temperature Controllers. Quick Selection Guide

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

TE-6300 Series Temperature Sensors

Series P20 Pressure Controls for Refrigeration, Air-conditioning and Heat-pump Applications. Feature and Benefits. P20 Pressure Control

M Ball Valve Linkage Kit

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

D-4070 Two Stage Pneumatic Actuator

M9300 Series Switch Kits

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

AV-8020 Series Floating Control Actuated Valve

Industrial and Commercial Duty IEC Motors

VA-715x Electric Valve Actuator

Design Standard. Purpose: Design Standard:

M9106-xGx-2 Series Electric Non-Spring Return Actuators

PISTON STYLE GAUGE. Mid-West Instrument

PP1 Series Piping Packages for VG1000 Series Ball Valves

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

RM-1200 Slim Round Control Damper

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

This valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

Class 9038 Type A Mechanical Alternator, Open Tank

Magnetic Overload Relays

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Electromechanical Level Control

M-100 Adjustable flow switch with right-angle flow

JC-VSD FP Series II Drives Product Bulletin 1

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Differential pressure switch for monitoring air pressure in HVAC systems.

VA9208-xxx-xx Series Electric Spring Return Actuators

VA9208-xxx-xx Series Electric Spring-Return Actuators

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

VA-7450 Series. Electric Valve Actuators

M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

Metasys Zoning Package Overview

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Transcription:

A70, A72 Series Temperature Controls for Refrigeration and Heating Master Catalog 125 Temperature Controls Section A Product Bulletin A70, A72 Issue Date 0418 Application The A70 single-pole and A72 two-pole controls are supplied in a wide selection of ranges to meet most application needs. See Temperature Ranges. Models may be supplied to open a circuit on temperature increase or close a circuit on temperature increase as required. An A70 single-pole control may optionally include a separate reverse-acting auxiliary contact. Models are available with a SPDT enclosed Pennswitch. All Series A70, A72 controls are designed for use only as operating controls. Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) or systems (alarm, supervisory systems) that protect against, or warn of, control failure. Specifications Features Long life contact structure with high contact force right up to break -- no bounce on make. Make reset models are trip-free. Ranges available to cover most applications. Auxiliary contact can be used to actuate an alarm circuit when the main contact opens. Two-pole construction provides a number of application advantages (see General Description ). Heavy gauge low profile stainless steel element cup to protect against mechanical damage. Fig. 1 -- Single function temperature control, Style 1. General Description The A70 controls provide dependability and quality at attractive prices. The A72 DPST controls provide a number of application advantages such as: Control of polyphase motors without use of magnetic starters where protection against overloading and single phasing is otherwise provided. Provides two separate control circuits necessary for the control of multiple systems. One set of contacts breaks the hot line when wired as a twopole switch in single-phase circuits. Permits control of two separate load circuits. Automatic control of heavy electrical loads. All A70, A72 controls have a single calibrated scale which shows directly both cut-in and cutout settings. Adjustments can be made readily without removing the cover. Johnson Controls 1 Code No. LIT-125155

Optional Constructions Adjusting Knobs May be supplied on differential or range adjusting screw for limited adjustment within specified limits. Adjustment Cutout Stops Cutout stops, factory set as specified. Bulb and Capillary Standard bulb and capillary are copper. Stainless steel, monel and steel bulbs are available, if required. Bulb and capillary with neoprene coating to military specifications MIL-R-3065, Grade SB-515-ABFF may be supplied at additional cost. Capillary length 6 ft (1.8 m) only. Covers Standard finish is gray enamel. Stainless steel covers available at slight additional cost for exposed installations. Fungus Proofing Supplied at extra cost, when specified. Conforms to government specifications MIL-V-173A. Manual Reset Provides lockout which requires manual reset before a restart is possible. Manual reset is tripfree and cannot be blocked or tied down. Button must be pressed and released before operation will resume. Metric Scale Plates Temperature models are available with Celsius plates. Mounting Brackets Controls are supplied less bracket unless specified. Controls may be supplied with mounting brackets at additional cost. Part No. 271-350 is standard. Fig. 2 -- Standard mounting bracket Bulb Wells Supplied at extra cost, when specified. Capillary Tubing Standard temperature elements supplied with 6 ft (1.8 m) capillary. Extra length tube available at additional cost. Longer capillary tube supplied up to 10 feet (3 m) in 2 foot (0.6 m) increments; over 10 feet (3 m) in 5 foot (1.5 m) increments. Contact Action Open on rise or close on rise as specified. Type Number Main Contact Action No. of Poles Type Number Selection Lockout with Manual Reset Temperature Elements Standard temperature element styles are shown on Page 5. For styles other than shown, please check with the nearest Johnson Controls district office or Customer Service. Knob Conduit Opening Misc. Single-Pole A70AA Open Low 1 No No 1/2 in. A70AQ Open Low 1 No Yes 1/2 in. Manual Start A70BA Open Low 1 Yes No 1/2 in. A70DA Open High 1 Yes No 1/2 in. A70GA Open Low 1 No No 1/2 in. Reverse Acting Aux. Contact A70HA Open Low 1 Yes No 1/2 in. Reverse Acting Aux. Contact A70JA Open High 1 No No 1/2 in. Reverse Acting Aux. Contact A70KA Open High 1 Yes No 1/2 in. Reverse Acting Aux. Contact Two-Pole A72AA Open Low 2 No No 3/4 in. A72AC Open Low 2 No No 3/4 in. No Cover A72AE Open Low 2 No No 3/4 in. Outdoor Case A72AP Open Low 2 No No 3/4 in. Manual Start A72CA Open High 2 No No 3/4 in. A72CE Open High 2 No No 3/4 in. Outdoor Case 2 A70, A72 Product Bulletin

Repairs and Replacements Field repairs must not be made except for replacement of the cover or knob. For a replacement control, cover or knob contact the nearest Johnson Controls wholesaler. Ordering Information When ordering, please specify: 1. Quantity on order. 2. Product Number if available. 3 If Product Number is not available, specify Type Number and the following specifications: a. Temperature range. b. Style of element. Indicate whether standard or cross ambient element -- bulb material and tubing (copper, steel, stainless or model). 4. Setting -- switch contacts to close at and open at. 5. If accessories are desired -- mounting bracket, manual reset, external knob or bulb well. 6. If external adjusting knob is required, specify if on differential or range screw. A70, A72 Product Bulletin 3

Fig. 3 -- Where it is desirable for the user to increase or decrease the DIFFERENTIAL ONLY, external adjusting knob is supplied on differential screw as shown. Knob is provided with stops and factory assembled to permit change only within specified limits. Fig. 4 -- External adjusting knob may be placed on range screw, as shown where it is necessary for the user to raise or lower both CUT-IN and CUTOUT points (differential remains constant). Knob is provided with stops and factory assembled to permit adjustments within specified limits. Note: Knob is usually factory assembled in either position as shown in Figs. 3 and 4, depending upon specifications of original buyer. However, knob may be changed in the field from the differential to the range screw or vice versa by loosening set screw and removing knob and indicator plate and reversing their positions. Assuming that knob is factory assembled on range screw (Fig. 4) and set to limit adjustment to 10 F (12 C), this adjustment will become approximately 5 F (-15 C) if knob is placed on differential screw (Fig. 3). 4 A70, A72 Product Bulletin

A70, A72 Product Bulletin 5

6 A70, A72 Product Bulletin UL Guide No. SDFY File SA516

Notes A70, A72 Product Bulletin 7

Notes 8 A70, A72 Product Bulletin Building Technologies & Solutions 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls and PENN are registered trademarks of Johnson Controls in the United States of America and/or other countries. All other trademarks used herein are the property of their respective owners. Copyright 2018 by Johnson Controls. All rights reserved.