Mash Tun / RIMS Tube Controller

Similar documents
JConn Inv. PID Controller Instruction Manual

Advanced Troubleshooting Guide Snorkel V Battery Charger Rev 0 3JAN07

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

SWA-24X2C PID Temperature Controller with Timer (SWA-2442C/2452C)

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

Chapter 4 Utility Systems Electrical

ECT Display Driver Installation for AP2 Module

EV Display User Guide

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

TC62D Installation Instructions

Trouble Shooting Guide for Hubbell Systems

Troubleshooting Guide for Limoss Systems

POWER. Switch opening. Enter/Exit Menu Menu Scroll Increase/Decrease Setpoint GCE SERIES MODEL 10AFE MODEL 20AFE

WP37 & HT37 User Manual

Operation Instruction Manual

ELECTRIC BENDING IRON

Note: Please read through the entire guide before attempting any kind of installation.

User s Manual. Automatic Switch-Mode Battery Charger

How Regenerative Braking Works

Using your Digital Multimeter

How do I get the most out of my new smart energy display?

Retro it Steering Column

Idle Free Systems, Inc. Reference Guide System Component Information

AFT mid drive kit Trouble shooting guide For 24v to 48V Kelly Controller KBS 48101L-L 100 A peak

ASSEMBLY INSTRUCTIONS

Virtual Ground for HV Boosters Calibration

Electrical Safety For Everyone. Leader s Guide

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

EGT Plus Instructions

ATD WATT INVERTER

Troubleshooting Guide for Okin Systems

Installation Instructions Jeep CJ-7

elabtronics Voltage Switch

MODEL INA CRYOSTAT INSTRUCTION MANUAL

Ford Racing BOSS 302 Engine Oil Cooler (11-14 GT)

Overcurrent protection

ASSEMBLY INSTRUCTIONS FOR TREE STAND

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

ATD WATT INVERTER

Working Principle of Power Saver as per Manufacture:

LETTER TO PARENTS SCIENCE NEWS. Dear Parents,

Porsche 928 with 16v LH-Jetronic Fuel System

Using the LCT100 for Load Cell Troubleshooting

6.5 Multi Function C5 LED Pre-Lighted Tree Pre-Lighted Tree 96842

3000 SERIES DRY-BLOCK HEAT SOURCE

GC SERIES HORTICULTURAL LIGHTING SYSTEM

Marine Exhaust Temperature Alarm. COMPONENTS

Farm Hand Vent Master 24

Throttle Cable Pull - Patent Pending By: NetGain Controls, Inc.

RED DRAGON ELECTRONIC PROPANE FLARE

SMT-AZC INSTALLATION / OPERATION MANUAL

PAGE Both power cords must be connected & powered to operate the E-TES 120.

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

IMPORTANT! DO NOT THROW AWAY THE SHIPPING CARTON AND PACKING MATERIAL

Pass Your Driving Test - Mistakes to Avoid

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Innovative Growing Solutions. Clima Control. Software-version: Issued: MANUAL

*Some speedometers have these additional electronic connections. If yours does, then remove the smaller slotted screws shown.

Wide Band EFIE Installation Instructions. Locate the wide band oxygen sensor current wire

PI1500X Power Inverter User s Manual

Equipment Register. Purchased from: Date of purchase: Serial Number:

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

Harris IRT Enterprises Digital Resistance Tester Model XP

I1 7.5 Pre-Lit Clear Christmas Tree

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

SawStop Quick Start Guide

HOW TO USE A MULTIMETER, PART 4: MEASURING CURRENT (AMPERAGE)

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

PORSCHE V r Valve Timing Instructions. Copyright 2009 Written by Mike Frye Edited my Adam G.

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Throttle Setup by Jason Priddle

The Sands Mechanical Museum

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Manual Alma Rally & Alma Rally Off-road. Version 1.1.1

AUTOMATIC SPRINKLER TIMER

Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007

FOR INDOOR/SEASONAL USE ONLY

Features: Enhanced throttle response, excellent acceleration, strong brakes and throttle linearity. Using LED program card to make adjustments.

Note: Please read through the entire guide before attempting any kind of installation.

INSTALLATION: HOW IT WORKS: SensiStat Energy Saver Refrigeration Controller. both the holding plate temperature and refrigeration box temperature.

Envirotainer RAP e2 Container Operations Manual

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

Cruise Control Wiring

Coleman Air C440-HVM 440 Amp Diversion Controller Version 3.2

INSTALLER S INSTRUCTIONS FOR TRI-METRIC Battery system monitor, Models TM-2025-RV and TM-2025-A. Contents

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

Thumper 60 AH. Thumper 75 AH

Unit 3 Lesson 3 Electric Circuits. Copyright Houghton Mifflin Harcourt Publishing Company

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL

SensiStat Energy Saver Refrigeration Controller Revision 1.14

In this article our goal is to take a tour around the modern Mustang cooling system (Fox & SN95s), and familiarize you with how all the stuff works.

EFIE Wideband O2 (Electronic Fuel Injector Enhancer) Installation & Operating Instructions.

ELECTRICAL SAFETY. Leader s Guide. Marcom Group Ltd.

Heat Engines Lab 12 SAFETY

Note: Please read through the entire guide before attempting any kind of installation.

Why is the Breaker Tripping?

Build Instructions and User Guide

Transcription:

Mash Tun / RIMS Tube Controller 1

Your new mash tun / RIMS Tube controller Thanks for buying your controller from us!!! Your controller is based on the MYPIN TA4 series PID controller. Unlike cheap REX branded controllers, MYPIN controllers are manufactured in China using modern Surface Mount technology. This is the same technology used to manufacture your high quality cell phone. Controller safety We use only aluminum housings for our controllers. We could save $10 to $30 per controller by switching to plastic housings. But we want to make sure if the unthinkable happens, that if your controller were to fail, all of the energy is safely contained inside your controller housing. We can't make that guarantee with a plastic housing and neither can anyone else with a plastic housing. Under the wrong conditions a plastic housing could melt down, catch on fire and burn your house down! All of our controllers have been tested behind GFCI and are GFCI compliant. We highly recommend that you run your controller on a GFCI protected circuit. But even with GFCI you are mashing with live power and it takes very little current to kill, so please follow these basic safety rules. 1. Never brew standing in water or in the rain. 2. Never plug in or unplug your heater or pump with the power on. 3. Never brew with a known electrical problem. 4. Never touch any nearby metal object when touching your brew equipment. 5. Never leave your brewery on & unattended. 6. STOP and investigate if you smell something electrical, or feel a shock from your equipment. 2

Getting familiar with your new controller Your new controller has six features on the front panel. A high temperature alarm (top, left corner). A toggle switch that turns the high temperature alarm on/off (right below the alarm). A red mushroom button serves as a main on/on switch as well as a panic stop button (center, bottom). A pump on/off switch operates independent of the mash on/off switch A mash on/off switch - operates independent of pump on/off switch A MYPIN TA4 series controller that manages your mash temperature. 3

Your new controller has four or five features on the bottom panel. Main incoming power at bottom left corner. If you purchased a 120V controller this will be an 8 foot power cord that will have a standard 3 prong plug or depending on options, a GFCI plug. If you purchased the 220/240V 30 Amp controller this will be a 12 foot 10 Gauge power cord with a 4 prong dryer style plug on the end. Temperature sensor in at the top left corner. Mash Control Outlet at bottom right corner. If you purchased a 120V controller this will be the outlet pictured above. The 20 Amp / Twist lock controller will have a 120V 20 Amp twist lock outlet in place of this plug. The 220/240V 30 Amp controller will have a 240V 30 Amp twist lock outlet in place of this plug. 4

Pump Control Outlet at top right corner. Any 120V pump drawing up to 3 Amps can be plugged into this outlet. We recommend MARCH pumps because we have had great success with them. Warning Do not attempt to plug a second heating element into the pump outlet. Doing so will damage your controller and void your warranty! Optional Flow Control Socket in center of panel. If you purchased a controller with the flow control option, your flow control switch plugs into this socket. The socket is designed to accept a 3.5mm (1/8 ) audio jack with your flow control switch wired across the tip and first ring. We offer a RIMS tube pre-wired with integral flow control and the correct jack. If you decide to design your own or buy someone else s flow control module, your flow control switch must be configured so that the switch is closed (or on) when you have flow and open (or off) when flow stopped. Note: If you plug nothing into this socket your controller will operate without flow control. Controller Power Options If you purchased the 120V standard version your controller has an 8 power cord with a standard 3 prong power plug as well as two standard 3 prong 15/20 Amp outlets. This controller can safely manage a heating element as large as 2200 Watts, providing the outlet you plug the controller into will safely handle the load. If you purchased the 120V version with GFCI plug your controller has an 8 power cord with a GFCI 3 prong power plug as well as two standard 3 prong 15 Amp outlets. This controller is limited to a heating element no larger than 1800 Watts because the GFCI plug itself is only rated for 15 AMPS (1800 watts). If you plan to run a pump the combined load can be no greater than 1800 watts Just like the other two 120V controllers, this controller will work with all 5

of our 120V RIMS tubes because we use 1650 WATT heating elements in all of our 120V RIMS tubes. If you purchased the 120V twist lock version your controller has an 8 power cord with a standard 3 prong power plug, a 20 Amp twist lock style L5-20R heating element outlet and a 3 prong 15 Amp pump outlet. This controller is designed to operate any element pre-wired with a L5-20P 120V 20 Amp twist lock plug similar to the plug used on Blichmann s 120V BoilCoil. This controller can safely manage a heating element as large as 2200 Watts, providing the outlet you plug the controller into will safely handle the load. Note: Most kitchen circuits installed since the mid 1970 s can safely handle 20 Amps / 2400 Watts providing nothing else plugged into the circuit is turned on at the same time. Most kitchen circuits installed before the mid 1970 s can only safely handle 15 Amps / 1800 Watts providing nothing else plugged into the circuit is turned on at the same time. If you purchased the 240V version your controller has a 12 10 gauge heavy duty power cord. To be able to support a 240V element and a 120V pump and be GFCI compliant your controller will have a 4 prong dryer plug. All 240V models ship with a standard 3 prong twist lock 30 Amp rated power socket and a 3 prong 120 Volt 15 Amp pump outlet. This controller can safely manage a heating element as large as 6000 Watts. All units come with a 304 stainless steel water tight PT-100 RTD temperature probe with 1/2 MPT type threads. A note on pumps: A 809 series March Pump draws 1.5 Amps (180 Watts) and you should factor in this wattage when planning your RIMS set-up. Also, all electric motors draw surge current of up to 6X their running current when starting. We include separate pump and mash switches so that you can to start your pump first 6

then start your PID controller, eliminating any effect the surge current might have on your mash cycle. MYPIN Controller Features Top Row Displays the current temperature Second Row Displays the set temperature (the temperature you want to regulate to Out1 Is on - red when the element is on & off when the element is off Out2/AL2 Not used in our application AL1 Turns on when AL1 value is crossed. If you use the temperature alarm, set the temperature to where you want the alarm to sound. We pre-set AL1 to 170F. AT On when in auto tune mode - Hold down to go into programming mode + - Change the set temperature Press then until the second row, right digit is flashing to change temp. - Press to select the set temperature digit you want to modify - Press to move digit up or down - Hold down to auto tune 7

Basic Operation For single-step mash you should set the controller to your mash temperature and leave it set. For convenience we test all of our controllers at 145F, the most common temperature for a single step mash, and if you mash at 145F you may not need to make any changes at all! For a multi-step mash you should start at the lowest temperature then increase the temperature based on your mash schedule. We suggest that you do a trial run with water while monitoring the temperature mid-way down your mash tun so that you understand how long it takes for the temperature change to propagate through your system. Temperature changes will not be instant because of the time it takes for your pump to circulate water through your system. High Temperature Alarm Your high temperature alarm makes the same sound as most home smoke alarms. We set the initial alarm temperature to 170F. When alarm is turned on (the switch is flipped up) and the AL1 set temperature is reached the alarm will go off and will continue to go off as long as the temperature is crossed. To silence the alarm just flip the switch to the down position. To change the alarm temperature, follow the instructions under Initial Settings to reach the AL1 step and then to change the alarm temperature. Initial Settings We set the initial settings and calibrate the PT-100 RTD before shipping your controller to you. In most cases you will not need to make any changes but because no two systems are exactly alike you may need to modify these setting to make your RIMS tube or mash tun perform better. To go into programming mode hold 8

down the button. Once in programming mode pressing the button will go through each of these menus in order. Lock Screen This is the first screen you enter programming mode. The value should stay set to 000. Press the next step. button to advance to the AL1 We pre-set the alarm to 170 because 170F is the denature temperature of your mash enzymes. AL1 Mode 2 is the default and we leave the setting at 2. 9

AL2 We do not use this. AL2 Mode We do not use this. Offset value used to calibrate your temperature probe. All PT100 RTD temperature probes must be calibrated before they can be used because small differences in the alloys used cause errors in their measurements. A temperature probe only needs to be calibrated once. Also, any new temperature probe must be calibrated before use or your measurements will be off. We have already calibrated your probe and the calibration (PUF setting) is 10

Temperature input type. This PID will accept K, J, T, E & S thermocouples and will also accept Pt100 type RTDs. We use PT100 RTDs for accuracy and the input is set to Pt. Proportional Band This modifies how hard the heating element comes on based on the percentage the temperature is away from your set temp. Default value is 3 but we found that a value of 0.52 works better for our RIMS tube. Integral Time Range This modifies how hard the heating element comes on based on how long your temperature is outside your set temp. Default value is 240 but we found that a value of 110.5 works better for our RIMS tube. Derivative Time Range Default is off but we found that a value of 27.62 works better for our RIMS tube. 11

Control Direction The MYPIN controller can be used to manage heat or cool. Default is heat which is exactly what we need. Control Hysteresis This sets the amount the temperature is allowed to drift before the PID controller will attempt to correct the temperature. Default is 1 and we leave it set at 1. Output Control Mode This sets the control (on/off) cycle time in seconds Default time for the model we use is 2 and we leave it set at 2. Measurement and Display C Celsius, F = Fahrenheit Default is C and we change the value to F before shipping 12

Calibrating your Controller for maximum Accuracy We already calibrate your controller at 212F the boiling point of water, but temperature sensors are not perfectly linear across their entire range. Your controller should do a great mash right out of the box but to get maximum accuracy you should calibrate your controller at the mash temperature you use most often. For single step mash this is likely in the 143F 147F range. If you do step mashing you should calibrate to somewhere mid-range. When calibrated this way the other temperatures will be off by very little. To calibrate you need to set the system up with water and use a thermometer you trust. If you don t have one you trust then you ll need to obtain at least three that you can compare. Most homebrewers have one or two and one or two they can borrow from friends. To start calibration you should place your reference thermometer or thermometers as close to your RIMS tube outlet or as close to your mash tun temperature sensor as possible. Set your mash temperature then start your mash cycle. Once your temperature stabilizes record your temperatures and use the process below to adjust the PID s offset. Note: If you use more than one reference thermometer don t be surprised if there is 5 or more degrees difference between them. We ve seen as much as 10 degrees difference between household thermometers which is why we calibrate to the temperature of boiling water. 13

To calibrate to your mash temperature Press and hold the button until LcK shows in the top display Leave the second line set to 000. Press and release the button 5 times to advance to the PUF step. This is the offset value used to calibrate your thermocouple. Press the key to program the offset. As you press the key you will see each digit in the second line flash. Press the keys to move digit up or down. To exit, press and hold the button until the top display returns to normal. Note: The offset should be set the same direction as the error. For example, if the PID is 3 degrees F high then +3 is added to the offset that may already be programmed into the PUF value. Fine Tuning your Controller s P, I and D Settings The advantage of a PID controller over a thermostat is a PID controller anticipates temperature change. When your wort temperature starts to drop the controller sees the drop and starts applying heat to prevent it. But no single calibration is perfect for 14

every system, so before using your controller you should do a trial run with water. When your set-up is correct you should see the temperature rise to your set temp, over shoot a little then come back down to your set temp. Then the temperature should fluctuate slightly above and below your set temp. How fast this happens depends on the water volume you use and your system s configuration. If your mash temperature over shoots your setting then stays high or if your mash temperature does not quite reach your set temperature and it stays low then you should auto-tune your controller. To auto-tune: Fill your mash tun with the amount of water you would usually use for dough-in, then add additional water equal to about half your grain bill. Plug in and start your controller and let it heat to within 10 degrees of the set temperature. Press and hold the button until the AT light comes on then release. Wait for the auto tune cycle to complete. During auto tune the temperature will go past the set temperature and then will come back down. This is normal. Auto tune will be complete when the AT light goes off. You should not need to auto tune again unless you are making major changes to your grain bill. If your temperature consistently runs low after auto tuning your controller then you need to look at the first three items on the list below. Five main factors control the accuracy of your controller. 15

Heating Element Size Your heating element size, or more correctly your heating element size relative to your mash size will impact the stability of your mash temperature. Generally speaking, the 1650 Watt element we use in our 120V RIMS tube is more than large enough for up to a 10 gallon grain bill providing you pre-heat your strike water. And the 5500 Watt element we use in our 240V RIMS tube is more than large enough for up to a 20 gallon or larger grain bill, and can easily bring a 10 gallon grain bill from faucet temperature to mash temperature within 30 minutes. It s easy to tell if your heating element is under size. Once you reach mash temperature your element should be off more time than on. You can monitor the element by watching the red OUT1 light on the PID. If the red light is on more than it s off then the element is working very hard to keep your mash up to temperature and it s under sized. Circulation Regardless if you run a RIMS tube, a HERMS system or a direct heated mash tun circulation is critical. Without enough circulation your temperature will stratify. With a RIMS tube and HERMS system your hotter temperature will stay on top and with a direct heated mash tun the mash closest to the element will be considerable warmer than the mash furthest away from the element. Note: regardless of the system you use you should expect some delay between your PID setting and your overall mash temperature because the temperature change will move through your mash in a wave. Radiation and Evaporation Losses As you heat your mash you are also constantly loosing heat through the sides and top of your mash tun. Most heat is lost from the top surface of your mash because you loose radiant and 16

evaporation heat from the top surface. You should always keep a cover on your mash tun to minimize both. If you are running a RIMS type system you will also loose some heat off the surface of your RIMS tube but this heat loss will be minor compared to the heat lost from the entire surface (sides, bottom & top) of your mash tun. The PID P Setting This setting modifies how strong the heating element comes on relative to how far off your mash temperature is. The PID I Setting This setting modifies how strong the heating element comes on relative to how long your mash temperature has been low. Converting the 240V controller from 4 Prong to 3 Prong power plug All of our controllers have been tested behind GFCI and are GFCI compliant. We highly recommend that you run our controllers on GFCI protected circuits. But we understand that some older houses have non-gfci compatible 3 wire dryer outlets and dryer outlets are a favorite 240V power sources for home breweries. Converting your controller from 4-prong to 3-prong power will make your controller non-gfci compliant. You can convert your controller to 3-prong power by removing our 4-prong plug and installing your own 3-prong plug. When installing your own 3-prong plug, the red and black wires wire attach to the two side blades, then the green AND white wires attach together to the center ground blade. 17