Installation & Operating Instructions

Similar documents
Adjustable Pneumatic Time Delay Switch

10W LED Die Cast Small Rectangle Bulkhead Light

18W Low Energy. instructions. Instructions

18W Round LED Slimline Emergency Light

24 Hour Immersion Heater Time Controller

25W LED Cross Bezel Bulkhead Light

Round Pattern 24 Hour Electromechanical Time Controllers with Half Day & Day Omit

24 Hour Mechanical Time Switch with Voltage Free Contacts

3000W Dusk to Dawn Light Controller

2x 10W LED Slimline Floodlight Twin Flood

Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

Wireless Digital Room Thermostat with Night Set-Back

I n s t a llat ion & O p e r atin g In s truc t ions

ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

INSTALLATION & OPERATING INSTRUCTIONS

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

ZonePlus Z322 zone valve Installation and commissioning instructions

2 PORT MOTORISED VALVE (28 mm)

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

3 PORT MOTORISED VALVE (22 mm)

3 PORT MOTORISED VALVE (32/38 mm)

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

IR600 Infra-red Lamp

HD18F2M1.

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

ELECTRICAL. Moisture Meter User Guide

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

IR125 & IR300 Infra-red Lamps

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

GL1200T Cut & Seal. (GL1200 Seal only)

1.Safe testing IMPORTANT:

Open Chassis Star-Delta Starter User Guide

RM moveit. Instruction Manual. Notebus -IC. Notebus + Notebus (LAP16-17H IC) (LAP16-17H EPM) (LAP16-17H B)

Self Closing Tap. Fitting Instructions & Contents List. Please keep these instructions for future reference and request of replacement parts

INSTRUCTION MANUAL (ATEX / IECEx)

2 PORT MOTORISED VALVE (22 mm)

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

MINIATURE CIRCUIT BREAKER

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Compact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN

Grosvenor Plus 138 decorative Solid brass highly polished, with rope-edge detail Pre-treated heat-cured powder lacquer finish Total safety

Compact System NRGS 11-2 NRGS Original Installation Instructions English

SetPoint 501 and 501s Controllers Installation and Operation Manual

2-Port and 3-Port Zone Valves & Actuators, PN16

##CFG BWOP Manuals## Astramax Mobile Models Assembly Guide

INSTRUCTIONS FOR USE

Hold / Abort Switches

1901 Thermostatic Shower Mixer

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

Digital display Pressure range ON/OFF output Linear output Model

OPERATING INSTRUCTIONS

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Element C8.3 Installation, Use and Inspection of Electrical Systems

Actuators for small valves

Underfloor to desk 231

2-Port and 3-Port Zone Valves, PN 16 / 20

ABB component drives ACS150, 0.5 to 5 Hp

Technical Data Sheet Sigma Series DS Meter

Air damper actuators

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

Battery Charger JCB- SCH20LI.2

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

MANIFOLDS & WATER TEMPERATURE CONTROL

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

1000 Series Piston Type Differential Pressure Gauges

SDS Enclosed Star-Delta Starter User Guide

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

026-2 : 1996 CEB STANDARD

Electromotoric Actuators

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

Peristaltic Cased Tube Pumps

MAKING MODERN LIVING POSSIBLE INT. Danfoss Link HR Hidden Relay. Installation Manual. Danfoss Heating

PURE SINE WAVE DC TO AC POWER INVERTER

To the Fitter: Ensure all relevant personnel read the points listed below and that a copy is passed on to the end user.

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Operating Instructions

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES

1100 Series Piston Type Differential Pressure Gauges

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Electromotoric Actuators

User Manual. Studio Rail. Size Version

Control solutions Biofloor

Digital Room THERMOSTAT for Model No. RT300

Declaration of Conformity

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Transcription:

Underfloor Heating Controller Cat. No TPT1 Installation & Operating Instructions Installation & Operating Instructions

Main unit (front view) Slots for snap-on bezel Indicator light shows green when mains is present and changes to red when heating mat/cable is energised Fixing holes 1 ON/OFF switch (position shown I = ON) Snap-on bezel (rear view) Floor temperature adjustment (setting 24ºC shown) Tongues engage with slots on main unit Fig 1

2 Introduction The TPT1 is a temperature controller for underfloor heating. It is rated at 16A (3.68kW). The unit controls to a continuous adjustable underfloor temperature between 10 C and 30 C. It does this by using the signal from an underfloor probe (included). Instructions of how to locate this are given in the Thermolay Cable and Mat instruction leaflet. The TPT1 also incorporates a switch for turning the supply to the heating element OFF when not required and a warning light showing green when mains is present and red when the heating element is energised. The TPT1 must be used with the temperature probe provided (other controllers in our range have different temperature probes which are not compatible with the TPT1). Connections are made to the unit according to the following diagram, be sure to check that the external link between terminals 1 and 3 is in place.

Connections 3 The external link shown between terminals 1 and 3 is crucial to the operation of the TPT1. This link is now installed at the factory prior to dispatch Siting The TPT1 should not be installed in a bathroom (or any other area where condensation may be present) to avoid an electrical safety hazard. Further instructions are given in the Thermolay Cable and Mat instruction leaflet. Fig 2

4 Installation The installation should be carried out by a competent person following the latest IEE wiring and local authority regulations in the UK or the relevant wiring and local authority regulations in other countries. The TPT1 underfloor heating controller is designed to fit onto either a BS4662 recessed single box or a BS5733 surface mount single box with earth terminal. The minimum box depth required is 32mm. The ideal mounting is at eye level for the shortest person who is likely to need to programme the unit. For details of the installation of the temperature probe and heating cable or mat see the Thermolay instruction leaflet. Switch OFF the mains to the controller. Remove the thermostat bezel by pulling forward on the bezel. Use a small screwdriver as a lever to remove the bezel when the thermostat is fixed to the wall. Cut the cable tails of the temperature probe and heating mat or cables to length and strip sleeving and insulation as required. Identify the wires and locate according to figure 2. Supply cable with a minimum of 2.5mm 2 conductor size must be used and must be earthed to the box earth. Tighten the screw terminals onto the wires and form the cables. Offer the unit up to the wall box forming the cables as required finally locating and tightening up the fixing screws supplied. Snap the bezel into place ensuring the tongues on the bezel line up with the slots on the main unit.

5 Earthing The TPT1 itself does not need to be earthed. The screen around the flying lead (cold cable) from the Thermolay mat MUST be earthed to the box earth terminal. This also applies to the screen at each end of the Thermolay cable, both of which must be earthed in the same way. Commissioning Turn the ON/OFF switch ON (I) and the setting dial to 30 C and check that the heating ON light shows red. After around 1 hour with an insulated wood sub floor and up to 5 hours with an uninsulated concrete sub floor there will be a noticeable change in floor surface temperature. Operation Set the floor temperature adjustment to a level giving the required comfort level at the floor surface. Use the ON/OFF switch as required to start and finish periods of heating.

6 Specifications Operating temp -10 C to 40 C Operating voltage 230V 50Hz Switching capability 16A resistive 3A inductive Temp probe flying lead 4m length Temp probe resistance 10KΩ approx. at 20ºC Temp control range 10 C to 30 C Temp accuracy ±1 C (at 20 C) Control type Normally open, voltage free Environmental protection IP20 EC directives Conforms to 73/23/EEC and 89/336/EEC Dimensions (mm) 84 x 84 x 49 (H x W x D) 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515.

For assistance with the product please contact: Helpline 020-8450-0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com A Group company 67.058.211 Iss 2