Naresuan University, Phitsanulok 65000, Thailand *Corresponding author ABSTRACT

Similar documents
OFF GRID PV POWER SYSTEMS SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

Vunivau, Bua Province Vanua Levu, Fiji Solar Home System Design. Luis A. Vega, Ph.D.

Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems

Impact of Electricity

Master Class on PVsyst Solar Project Designing Tool 7 th June 2013

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

DIN W.-Nr AISI 304

Yield Reduction Due to Shading:

Capture The Power of Photovoltaics. IEEE Power Engineering Society Meeting May 2005

SunSwitch setting requirements min. 15 % Daily output in average month 154 m³

SunSwitch setting in PumpScanner. Daily output in average month 219 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Energy Produced by PV Array (AC):

Daily output in May 32 m³

Development of a Stand-alone Solar

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Designing Stand Alone Systems. Overview, components and function, Elements in Design

Daily output in April 193 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

Application of HOMER Software in Wind and Solar Resources Integration

Yield Reduction Due to Shading:

4HS MultiPower Submersible Pumps. Installation and Operating Manual. M u l t i P o w e r. man4hs_mp_11_eng

DC and AC coupling: which one is the best solution?

4TCH Submersible Pumps. Installation and Operating Manual

Design and Simulation of Grid Connected PV System

Ningbo Star Solar Co.,Ltd Tel:(86) Fax:(86)

System selection for Stand-alone S

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

12-Batteries and Inverters. ECEGR 452 Renewable Energy Systems

Available online at ScienceDirect. Energy Procedia 36 (2013 )

4HS MultiPower Submersible Pumps. Installation and Operating Manual.

Water temperature: Dirt loss: Total dynamic head:

A Review on Grid Connected 100 kw Roof Top Solar Plant

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

Company name: Created by: Phone:

By: Ibrahim Anwar Ibrahim Ihsan Abd Alfattah Omareya. The supervisor: Dr. Maher Khammash

Glossary. * Credit for glossary starter: Florida Solar Energy Center. August 2015 PV Installer's Course: Glossary 1

Solar Charge Controller

Smart community clustering for sharing local green energy. Yoshiki Yamagata, Hajime Seya and Sho Kuroda

Large scale solar power plant in Nordic conditions. Antti Kosonen, Jero Ahola, Christian Breyer, Albert Albó

Results of annual simulation

Thomas Alston Director of Business and Policy Development. Presented By N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257

Current Automation Catalogue

Kaneka K60 60W Thinfilm Solar Panel

Solar Electric Systems. By Andy Karpinski

KIT SOLAR MONTE PERDIDO

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

Introduction to solar PV energy

MPPT Control System for PV Generation System with Mismatched Modules

Impact of Reflectors on Solar Energy Systems

SOLAR (PV) - GRID/DG GREEN POWER SUPPLY FOR RURAL INDIA

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

TBARC Programs Solar Panel. 15 Aug 2013 By Israel AD7ND

TEST PROCEDURES FOR SHS COMPONENTS

SPG-400. Solar-powered generators

Solar Charging Station for Education and Research

P H O T O V O LTA I C

Technical standard for AC, DC and street light systems

Solar/Wind Hybrid Renewable Power Generator for Powering Rural Dynamic Message Sign

Solar/Wind Hybrid Renewable Power Generators for Minnesota Rural Transportation Applications

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

Stand-alone PV power supply for developing countries

SOMALI ENERGY TRANSFORMATION (SET) PROJECT

K50. Technical Sheet

Power Management with Solar PV in Grid-connected and Stand-alone Modes

Modular Solar Controller / Charger (Patent Pending)

Implementation of Bidirectional DC/AC and DC/DC Converters for Automotive Applications

Implementation Soft Switching Bidirectional DC- DC Converter For Stand Alone Photovoltaic Power Generation System

Design and Control of Hybrid Power System for Stand-Alone Applications

Solar Power for Home...

OFF GRID Solar system

Solar Powered Wireless Sensors & Instrumentation

A 3-Year Case Study of a Residential Photovoltaic System with Microinverters

672W Off Grid Residential Package

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

K10. Technical Sheet

: IEC System for Conformity testing and Certification of Electro technical Equipment

Behaviour of battery energy storage system with PV

DESIGN AND FABRICATION OF A SOLAR SPRAYER

SunRay Triangular. SunRay Triangular comes with tailored Smart City solutions, and is an ideal energy provider for streets and highways.

Components for your PV Solar Electric System

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Impacts of distributed photovoltaic generation on Jenin distribution network: voltage level, power losses, power factor and power quality

Renewable Hybrid / Off-grid Solutions

Energy Management and Control System for Smart Renewable Energy Remote Power Generation

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

Solar inverter AX-series

Annex 1. Field Report: Solar Electric Light Fund Energy Harvest Control Study

SCC-MPPT Solar Charge Controller

[Patil, 7(2) April-June 2017] ISSN: Impact Factor: 4.015

PV-Wind SOFTWARE for Windows User s Guide

BRAVO Inverter/Battery Charger. Table of Contents

OUR PARTNERS. More: Please note: All product illustrations in this brochure may differ from the original.

Wind Energy System.

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under Ownership Model

A Smart Mobile PV-Wind Hybrid System Prototype for isolated electrification. Abstract

X600. Technical Sheet

Transcription:

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 Performance Evaluation AC Solar Home Systems in Thailand: system using multi crystalline silicon PV module versus system using thin film amorphous silicon PV module Wuthipong Suponthana a, Nipon Ketjoy a*, Wattanapong Rakwichian a and Phumisak Inthanon b a School of Renewable Energy Technology (SERT), Naresuan University, Phitsanulok 65, Thailand Tel: +66-5526-128, Fax: +66-5526-167, Email: niponk@nu.ac.th b Faculty of Agriculture, Natural Resources and Environment Sciences, Naresuan University, Phitsanulok 65, Thailand *Corresponding author ABSTRACT There are more than 2, AC output solar home systems (AC SHS) installed in Thailand form 24 to 26. Two types of PV module are used in this massive installation, multicrystalline silicon (mc-si) PV module and thin film amorphous silicon (a-si) PV module. Two type of charge controllers suitable for each type of PV module are installed to control of charging from PV modules to deep cycle lead acid battery. The system with mc-si PV module uses shunt interrupting design or On-Off charger controller while the system with a-si PV module uses DC-DC converter with maximum power point tracking (MPPT) algorithm charge controller due to high PV output voltage from a-si PV module. The AC SHSs are operated by allow to full daily energy yield form PV to charge their batteries without maintenance of batteries and with maintenance of the battery to observe the in system performance in both conditions. The performance of these two AC SHSs are monitored and analyzed by using IEA PVPS TASK 2 performance evaluation model. Keywords: Performance Evaluation, Stand Alone PV System, Solar Home System 1. INTRODUCTION Thailand mega-project 2, SHS's uses two types of PV module, mc-si and a-si, which have different output voltage at maximum power (V Pmax ). The mc-si (36 cells) PV module has V Pmax at 17.2 Vdc which is suitable to charge battery which has nominal voltage 12Vdc. The cost effective charger controller for this type of PV module is shunt interrupting or On-Off charger controller [5] thus On-Off charger controller is selected by most manufacture to use with mc-si PV module in this project. The a-si PV module has higher V Pmax at 44 to 68 Vdc which is not suitable to charge battery with nominal 12 Vdc thus SHS with a-si PV module requires voltage conditioner such as DC-DC converter to change V Pmax to suitable voltages for charging 12 Vdc battery. Since this type of charge controller has to convert DC voltage which mean the input part of the charge controller connected to PV module and the output part of the charger controller connected to the battery are separated thus the good charge controller integrates the Maximum Power Point Tracking (MPPT) algorithm into the input part which is called MPPT charge controller. In this paper we will evaluate the system performance of AC SHS using mc-si with On-Off charger controller and a-si with MPPT charge controller. Two SHSs, mc-si PV module with On-Off charge controller and a-si PV module with MPPT charge controller are set up in Bangkok with other BOS, deep cycle lead acid battery, square wave inverter and resistive load, to evaluate performance of two type SHSs in warm climate condition such as Thailand.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 36 The systems are operating without any maintenance of battery and maintenance of battery by refill distills water every month. The performance evaluation model introduced by IEA PVPS TASK 2 is applied to evaluate result data [1,2]. 2. AC SOLAR HOME IN THAILAND The AC SHS system installed in Thailand's mega-project consists of PV module 12 Wp, charge controller with charge current 1 A, square wave output inverter 15 Watt, deep cycle battery 125 Ah 12 Vdc. The installation sites are in remote area of warm climate and high humidity environment locate in Thailand between latitude 5 45'N to 2 3'N and longitude 97 2' E to 15 39' E. The proposed and installed systems consist of several PV modules power rating depend on manufactures and the PV module have to be assembled or manufactured in Thailand. There are two types of PV modules proposed to used in this project which are: 1) mc-si PV module with 36 cells type, power rating 12 Wp (Solartron) or 123 Wp (SHARP) with V Pmax around 17 Vdc. 2) a-si PV module, power rating 4 Wp x 3 (BSC) or 64 Wp x 2 (KANEKA), power rating 12 Wp or 124 Wp with V Pmax around 44 Vdc and 68 Vdc respectively. These two types of PV module which require different type of charge controller to charge battery which has nominal voltage 12 Vdc in the system. Both types of AC SHS use the same deep cycle flooded type battery capacity 125 Ah @ 2 hours discharge rating and square wave output inverter to convert DC power form 12 Vdc battery to AC power at 22 Vac,rms and supply to load which are two set of fluorescent lamps 1 Watt with electronics ballast. The AC SHS is prepare to be use with color television and other type of appliances under 15 watt of power rating and loads have to be capable to use with square wave output of the inverter. The configuration if these two systems are shown below (Fig 1). Fig. 1 Solar Home System using mc-si PV module with On-Off charge controller and a-si PV module with MPPT charge controller 3. EXPERIMENTAL SYSTEM CONFIGURATION The test systems consist of two SHS's. The mc-si PV module 123 Wp with PWM charge controller, 15 Watt modify sine wave inverter, 125 Ah 12 Vdc battery and 1 watt linear load. The a-si PV module 64 Wp x 2 = 128 Wp with MPPT charge controller, same model of inverter and battery as shown in the

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 37 Fig 2 and the picture of the PV modules installation and equipments are shown on Fig 3. The recorder is set to record solar irradiance, ambient temperature, mc-si and a-si module temperature as environmental data. Both mc-si and a-si PV are measured value of module output voltage and current every 5 seconds as well as voltage and current that the systems charge and discharge the batteries. AC power and energy consumed by load are also recorded. The systems are set up by exposing mc-si and a-si PV module for 2 months before start recording the data and analyzed in this paper. The Batteries in both systems are fully charge before initial starting and are forced to deliver stored energy to 1 watt resistive load through inverter until the battery voltage reaches low voltage cut off (1.5 Vdc). The batteries are prepared to have enough storage for energy produced by PV module on the next operating day. Fig. 2 Experimental system configuration

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 38 3.1 PV modules characteristic Two type of PV module used in AC SHS are mc-si PV module and a-si PV module whose specification are shown in the Table 1. In this performance evaluation the PV module from SHARP and KANEKA are use to represent mc-si PV module and a-si PV module respectively Table 1 Characteristics of PV module proposed to use in AC SHS project in Thailand Module Characteristic mc-si a-si Solartron SHARP BSC KANEKA Power Rating @STC (W p ) 12 123 4 64 Open Circuit Voltage (Volt) 21.5 21.3 62.2 96 Short Circuit Current (Amp) 7.45 7.9 1.16 1.17 Voltage at MPP (Volt) 16.9 17.2 44.8 68 Current at MPP (Amp) 7.1 7.16.9.94 Power Temperature Coefficient (% of degree C) Not specify -.52 -.2245 -.26 Module Efficiency (%) 12% 12.6% 5.9% 6.8% Area (m 2 ).979.992.79.95 3.2 Solar charge controller In a small stand alone PV system such as SHS the effectiveness of harvesting energy form the sun highly depends on the suitability of choosing charger controller to work with PV module. There are several types of charger controller designed to use with PV power system in the market. According to the charge controller survey by Photon Energy magazine among 38 manufactures and over 26 models of charge controller only 3 types of algorithms used in these charge controllers, interrupting or On-Off (series or shunt), Pulse Width Modulation (PWM series or shunt) and MPPT charger controller [4]. The principle of charger controller operation and recommend practice of charge controller is also discuss in [3]. The charger controller which is used with mc-si PV module AC SHS in Thailand are using Interrupting (On-Off) algorithm or Pulse Width Modulation (PWM) which may be series or shunt regulator. The On-Off series regulator uses electronics control electromechanical switch (relay) or electronics switch (Silicon Control Rectifier (SCR) or Filed Effect Transistor (FET)) to connect or to disconnect PV module output from the battery terminal when charger want to charge or to stop charging the battery. The On-Off shunt regulator also uses the types of switch to short output of PV module when the controller do not want PV module to charger the battery and leave the shunt switch open when it want to charge battery. The PWM charger whether series or shunt regulation works in the same operation beside it use higher frequency of switching thus only electronics switch is used in this type of charger. Both small On-Off and PWM in SHS whether they are series or shunt charge controller uses battery voltage as an input parameter to control the shunt or series switch to be turn on and to be turn off. The switches will be turn on or be turn off to charge battery according to the algorithm described above when battery voltage is lower than set point and stop charge battery when the battery voltage is reach voltage indicated that battery is fully charge. The basic series or shunt regulator are shown in Fig 4.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 39 The On-Off charger may have two set points which is voltage regulation (VR) set point and voltage regulation reconnection (VRR) set point or use other techniques discussed in [3] such as modify constant voltage which change VR to what is called Boost Charge to enhance the performance of charging. PWM algorithm which may be PWM series or PWM shunt regulation uses electronics control switch only to turn on and to turn off control switch in variable frequency, 5 Hz to 1 khz or higher with a variable duty cycle to maintain battery charging voltage close to the set point [4]. The PWM algorithm allows battery to be charged at the state near fully charge in precise voltage and produce less heat. The simple diagram of PWM charger is shown in Fig 5. Fig. 3 Experimental Systems at Bangkok, Thailand Fig.4 Basic series and shunt regulator

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 4 The AC SHS with a-si PV module can not use simple On-Off or PWM charger since this type of PV module has high voltage at maximum power (V Pmax ) as shown in Table 1. The high V Pmax is not suitable to charge battery by directly connect to terminal of nominal 12 Vdc battery. To adjust a-si PV module s output voltage down to the suitable charging voltage level of the battery a DC to DC converter which converts high DC voltage input to low DC voltage output or buck converter is applied to this charge controller. The charger with DC to DC converter allow separation controlling between PV module s current and voltage and battery charging current and voltage by using high frequency transformer. By separating to high DC voltage side and low DC voltage side the voltage level of PV module which is maximum power (V Pmax ) and the voltage level of nominal battery voltage can be different. At the input of DC to DC converter attached to the output of PV module, the PV s maximum power (P Pmax ) searching algorithm called maximum power point tracking (MPPT) is embedded into the controller. The algorithm capable to search for the current and voltage at the present solar irradiance that allow the PV module to supply maximum power at any solar irradiance by adjusting current at input of DC to DC converter and calculated output power then adjust current to search for the maximum output power. At the output of DC to DC converter there is a suitable voltage level for charging battery. Since the output of DC to DC converter can be freely control form input the charger can apply multi stage charging method which enhance battery charging performance. This type of charger controller is call MPPT charger controller. The basic diagram of the MPPT charge controller is shown in Fig 6. Fig. 5 PWM series and shunt charger

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 41 Fig.6 Maximum Power Point Tracking (MPPT) Charger The advantage of MPPT charge controller is the PV voltage terminal can be independently controlled separately and not directly depend on the battery voltage. The MPPT charger allow PV module to operate at optimal voltage which is V Pmax at present irradiance to get maximum PV module power at that time. This MPPT algorithm allow the PV module used with MPPT charger to deliver higher energy yield than on-off charger which PV module voltage is operated by the influence of battery voltage directly. Fig 7 shows the difference between PV module voltage and battery voltage of the system using a-si PV module form KANEKA with MPPT charger and mc-si PV module form SHARP with on-off charger. Both module characteristics are shown in Table 1. a-si PV module voltage (Vdc) 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 mc-si PV module voltage and battery voltage (Vdc) 5:5 6:4 7:3 8:2 9:1 1: 1:5 11:4 12:3 13:2 14:1 15: 15:5 16:4 17:3 18:2 PV Voltage a-si Battery Voltage a-si PV Voltage mc-si Battery Voltage mc-si Fig. 7 The PV module voltage and battery voltage

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 42 The PV terminal voltage of a-si PV module is almost stable around 6 Vdc during normal charging (bulk charging) due to the MPPT algorithm was tracking for maximum power from irradiance at that time. The PV terminal voltage of mc-si PV is increased due to the battery voltage rises when battery is charged thus the mc-si PV voltage may not be at the point that the mc-si PV module can provide maximum power at that irradiance. The calculation of V Pmax of a-si and mc-si PV module voltage using measured parameter which are irradiance, ambient temperature and back of PV modules temperature data are performed by using performance characterization procedure introduced by Sandia National Laboratories [8]. The comparison between calculated V Pmax of each PV module and measured PV modules terminal voltage are shown in Fig 8. The results show that during a day of charging process the system using on-off charger operates with mc-si PV module charge battery with PV module terminal voltage different form the VPmax of the module for most of the time during the day of operation while the system using MPPT charger make a-si PV module voltage be close to the V Pmax of the PV module at most of the time beside in the morning and at the evening when the irradiance it lower than 1 W/m2. During the time that the battery is fully charge which the MPPT charger do not need maximum power form the a-si PV module the MPPT charger reduce energy that it took from PV by drawing lower current which make the PV voltage drift from V Pmax to other level. 3.3 Battery The battery use in this AC SHS is specified in project specification to be deep discharge cycle service type lead acid battery. This battery is flooded vent type which is modified from a standard motive power or traction battery used in golf carts battery. It has 6 cells with nominal voltage 12 Vdc with capacity 125 Ah @ 2 hours rating with almost same out looking of car battery in local market. 3.4 Inverters The inverters is the device that invert DC electrical power stored in the battery or produced form PV module to AC electrical power. The inverter specified in project have to invert DC energy form 12 Vdc to 22 Vac with output voltage wave form in step wave or square wave with power rating not lower than 15 Watt. The efficiency of inverter is specified not less than 8% at full 15 Watt resistive load.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 43 4. PERFORMANCE EVALUATION PARAMETERS The two solar home system will be compared their performance by using parameters suggested by IEA PVPAS Task 2. The parameters usually used to assess the performance of stand alone system are the following [1,2]: a-si PV module voltage (Vdc) 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 mc-si PV module voltage (Vdc) 5:5 6:4 7:3 8:2 9:1 1: 1:5 11:4 12:3 13:2 14:1 15: 15:5 16:4 17:3 18:2 PV Voltage a-si Simulated Vmp a-si PV Voltage mc-si Simulated Vmp mc-si Fig. 8 Comparison between measuring PV terminal voltage during charging and calculated V Pmax of PV modules at the time of charging When: YA = EA/Po (kwh/wp.d) : Array yield (1) YR = Ht/GSTC (kwh/wp.d) : Reference yield (2) Yf = EPV/Po (kwh/wp.d) : Final yield (3) EPV = EL/(1+EBU/EA) (Wh) : PV energy consumed (4) LC = YR-YA (kwh/wp.d) : Capture losses (5) LS = YA-Yf (kwh/wp.d) : System losses (6) PR = Yf /YR : Performance ratio (7) P o : Peak Power (W p ) H t : Mean daily irradiation in array plane (kwh/m 2.d) G STC : Reference irradiation at STC (1 kw/m 2 ) E A : Array output energy (kwh/d) E L : Energy to loads (kwh/d) E BU : Energy from back-up system (kwh/d) : PV array potential energy (kwh/d) E POT Performance Ratio (PR) is the parameter used in representing the capability of energy production potential of the system. Higher PR is mean better system design and lower PR value mean production loss

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 44 due to design or technical problem [5]. The value of PR is load consumption dependent which means that not suitable design between PV and load may lead to low PR value. IEA TASK 2 has introduced additional indicators called "Used Factor" (UF) which defined as: UF = E A / E POT (8) In Stand Alone Systems E POT is determined by measuring the PV array energy even during disconnections [2]. η SYS = Y f /Y A : system efficiency (9) η PROD = E POT / P o.y R : production efficiency (1) PR/UF = η SYS.η PROD (11) Normally in the system EPOT is not monitor thus UF could not determine IEA TASK 2 also introduce another coefficient called "Production Factor" (PF) which use the parameter at STC specify by manufacture to determine it as follows. PF = E A / (Po.H t /G STC ) = Y A /Y R (12) PR/PF = η SYS = Y f /Y R (13) 5. RESULT OF EVALUATIONS 5.1 Environmental Characteristics At the experimental location, 13 39 54 N and 1 38 1 in Bangkok, Thailand where the recorded minimum and maximum of daily average ambient temperature is recorded 31.44 C and 42.44 C respectively with annually average of 38.52 C. The minimum daily irradiation is 1.65 kwh/m 2.day and maximum is 6.94 kwh/m 2.day with average of 4.84 kwh/m 2.day. The ambient temperature is as high as 42 C during summer season form March to May and the daily average ambient temperature is not lower than 3 C for the whole year at the test location. The solar irradiance, ambient temperature and temperature at back of PV modules of the experiment systems on one clear sky day is shown in Fig 9. Temperature measure at the back of PV module of a-si PV module is higher than temperature measured at the back of mc-si PV module. The temperature at the back of PV module has the same trend line indicate the trend of daily irradiance. Yearly profile of daily ambient temperature, irradiation, and back of PV module temperature of the test system are shown in Fig 1. 5.2 Battery Charging Characteristics The battery voltage and current characteristic during a day of charging on a clear sky day of the AC SHS using a-si with MPPT charge controller with DC to DC converter comparing with the system using mc-si with On-Off charge controller is shown in Figure 11 and the battery charging power and charging energy are also shown in Figure 12.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 45 1 7 9 8 7 6 5 Irradiance (W/m 2 ) 6 5 4 3 2 1 Ambient Temperature ( o C) 4 3 2 1 6::1 6:5:1 7:4:1 8:3:1 9:2:1 1:1:1 11::1 11:5:1 12:4:1 13:3:1 14:2:1 15:1:1 16::1 16:5:1 17:4:1 Irradiance Ambient Temperature mc-si Back Panel Temp. a-si Back Panel Temp. Fig. 9 Irradiance, ambient temperature and back of PV module temperature of mc-si and a-si PV module in a clear sky day at experimental site. 7 2 6 5 18 16 14 Temperature ( o C) 4 3 2 1 12 1-Jan 1-Feb 1-Mar 1-Apr 1-May 1-Jun 1-Jul 1-Aug 1-Sep 1-Oct 1-Nov 1-Dec 1 8 6 4 2 Irradiation (kwh/m 2.day) Ambient Temperature Back PV module Temp. mc-si Poly. (Irradiation (kwh/day.m2)) Poly. (Back PV module Temp. mc-si) Back PV mudule Temp. a-si Irradiation (kwh/day.m2) Poly. (Ambient Temperature) Poly. (Back PV mudule Temp. a-si) Fig. 1 Daily maximum ambient temperature, back of PV modules temperature and daily irradiation at experimental location in a year.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 46 Irradiance (W/m 2 ) 12 11 1 9 8 7 6 5 4 3 2 1 6::4 6:4:4 7:3:4 8:2:4 9:1:4 1::4 1:4:4 11:3:4 12:2:4 13:1:4 14::4 14:5:4 15:4:4 16:3:4 17:2:4 18::9 18::34 Irradiance Battery Current a-si Battery Voltage a-si Battery Current mc-si Battery Voltage mc-si Fig.11 Battery charge voltage and current of a-si PV module with MPPT charger and mc-si PV module with on-off charger. Irradiance (Watt/ m 2 ) and Charging Energy (Wh) 12 11 1 9 8 7 6 5 4 3 2 1 6::4 6:4:4 7:3:4 8:2:4 9:1:4 1::4 1:4:4 11:3:4 12:2:4 13:1:4 14::4 14:5:4 15:4:4 16:3:4 17:2:4 18::9 18::34 Irradiance Charging Energy a-si Charging Energy mc-si Charging Power a-si Charging Power mc-si 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 Battery Voltage and Current (Vdc, Ampere) 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 Battery Charging Power (W) Fig. 12 Charge Power and Charge Energy of a-si PV module with MPPT charger and mc-si PV module with on-off charger.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 47 According to the information of the manufacture of both chargers the regulation set point of each charger are MPPT charger: Boost charge regulate voltage = 14.5 Vdc Boost charger time for 2.5 hours Start count boost charge time when >14. Vdc Float charger voltage at 13.6 Vdc On-Off charger: Boost charge regulate voltage = 15.15 Vdc Boost charge for 2.5 hours Start count boost charge time when >15. Vdc Float charge voltage at 14.4 Vdc On the day of evaluation the observed result show that the battery charging power of a-si PV module with MPPT charger is higher than the system using mc-si with On-Off charger during 8: to 14:3 which is the time that MPPT charger perform bulk-charge to inject highest current that it can get form PV at any irradiance to the battery. The battery voltage reach 14. Vdc at first time about 13: which charger start boost charger counter 2.5 hours form 13: to 15:3 which the charger enters boost-charge which the charger voltage is controlled and the current is limited down to the values that will not make battery voltage go higher than the set boost charge voltage. From 15:3 the MPPT charger going to float-charge which the battery charging voltage is limited to 13.8 Vdc. The charge current from both system are in the same trend of irradiance of the day. The a-si PV with MPPT charger push current to its battery for 43.4 Ah from morning until 15:3 and the battery voltage reach full battery set point them it enters float charging for the rest of the day to charge another 2.1 Ah until the irradiance is become zero. The total charge current is 45.5 Ah. The mc-si PV module system with On-Off charger charges battery with lower current since the PV connected to battery is operate between 12 Vdc to 14.5 Vdc which is the voltage that PV can not provide maximum power to battery. On the same day the mc-si PV system with On-Off charge controller can charger battery for 38.7 Ah from morning until 15:3 and 6.1 Ah for the rest of the day with out going to float charging. The total charge current is 44.8 Ah. It is indicated in Fig 12 that the whole day charged energy from both a-si PV module system and mc-si PV module system to batteries are almost same 625 Wh and 612 Wh respectively since the MPPT charge controller limit power form PV to battery due to the battery is fully charged. The a-si PV module system could produce more energy on that they if there is higher battery capacity to receive the energy. The efficiency of charger is also recorded for 15 months and exhibited in Fig 13. The result show that the efficiency of on-off charger is generally above 93% while the efficiency of MPPT charger is only around 83%. The lower efficiency of MPPT charger is the result from lost at the DC-DC converter inside.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 48 95% 93% 91% 89% Efficiency (%) 87% 85% 83% 81% 79% 77% 75% Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar MPPT Charger with a-si PV module On-Off Charger with mc-si (12V) Fig. 13 Efficiency of On-Off Charger and MPPT charger 5.3 System performance evaluation Both systems are operate without any maintenance on PV modules, batteries, charge controllers, inverters and loads to see the real performance under condition close to the worst case. There is no distill water be added to the batteries since the experiment start. The battery remain operate for 9 months before completely fail. The new batteries for both system are replaces on the 1 months and the experiment is going on with distill water added to maintain batteries every 3 days. a. Array Yield (Y A ) evaluation The energy produced by PV module per peak power (Wp) of the module or Array Yield (Y A ) from system using a-si PV module is higher than the system using mc-si PV around 2% at the beginning of experiment and Y A of both systems have trend to be lower from the affect of battery has no maintenance. The system with a-si has trend to be lower while system with mc-si has stable Y A after 15 months of operating the system as shown in Fig 14. This phenomenon occurs in the process of a initial stabilization of a-si. b. Efficiency of storage device The battery charging energy and discharging energy on each day is recorded and calculated for battery efficiency. During the first 9 months that battery had no maintenance (no distill water were added to the batteries) the energy charged to the batteries can be store and discharged to be used by inverter for about 8% of charged energy at the beginning of experiment and reduced to lower than 2% in 9 months and finally the batteries can not store energy. After both AC SHS the systems were replaced with new batteries

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 49 the efficiency of batteries are recorded at about 8%. The batteries were maintain by checking electrolyte level and distill water were added every month the records show reducing of the efficiency in the first 3 months and stable at about 75% as shown in Fig 15. 6 5 Array Yield (YA) kwh/wp.day) 5 4 3 2 1 4 YA(a-Si) - YA(mc-Si) (kwh/wp.day) 3 2 1 - -1 1-Jan 1-Mar 1-May 1-Jul 1-Sep 1-Nov 1-Jan 1-Mar YA of a-si Different YA(a-Si) and Ya(mc-Si) Linear (YA of a-si) YA of mc-si Linear (Different YA(a-Si) and Ya(mc-Si)) Linear (YA of mc-si) Fig. 14 PV array energy yield (YA) and the different between YA of a-si PVmodule system and mc-si PV module system of operating as AC SHS for 15 months 12% 1% 8% Efficiency (Percent) 6% 4% 2% % Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Battery used with a-si PV system Battery use with mc-si PV system Fig. 15 Efficiency of energy storage calculated form daily charging energy and discharging energy

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 5 c. Array Output Energy (E A ) The Array Output Energy (E A ) generated form a-si PV SHS is higher that E A form mc-si SHS for 1% to 18% form start of the experiment until the battery efficiency dropped to about 4% (as shown in Fig 15) which at that time the E A of mc-si is shown higher. By evaluation of the recorded data at the period the result show that this situation is created form charger controller of a-si PV SHS stop charging the battery due to the battery voltage reach set point after charging for short time. After replace new battery E A of a-si PV SHS is higher than mc-si PV SHS again as shown in Fig 16. Array Output Energy(Wh/day) 8 7 6 5 4 3 2 1 - Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Dec Jan Mar Mar 12% 11% 1% 9% 8% 7% 6% 5% 4% 3% 2% 1% % -1% -2% -3% -4% Difference between Array Output Energy (%) Different betweer a-si and mc-si a-si PV Module System (EA) mc-si PV Module System (EA) Fig. 16 Array output energy (E A ) of a-si PV SHS and mc-si PV SHS d. Production Factor (PF) and System Efficiency (η SYS ) The production factor of a-si PV system is higher than mc-si PV system during the normal battery condition but the system efficiency of mc-si PV system is higher than a-si PV system due to higher loss in MPPT charge controller as shown in Fig 17. e. Performance Ration (PR) and Final Yield of the System (Y f ) The performance ration (PR) of both system are about same at.45 to.5 and lower when battery has low efficiency. The Final Yield (Yf) of both systems also about same figure beside during low battery efficiency that the a-si PV system shows lower Yf since the MPPT charger stop charging from detecting high battery voltage in short time after charging battery while on-off charger keep pushing current to the defective battery due to high charge set point. The PR and Y f of both systems recorded for 15 months of operation are shown in Fig 18.

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 51 6. CONCLUSION The a-si PV module SHS with MPPT charger controller installed at warm climate environment such at experimental location in Thailand deliver higher energy output as shown by its Array Output Energy (E A ), Array Energy Yield (Y A ) and Production Factor (PF) than the system using mc-si with on-off charge controller. Both systems charge their produced energy into batteries which the charge efficiency of each system is depend on the charge controller topology. 1.2 18% 1. 15%.8 12% Production Factor.6.4 9% 6% System Efficiency.2 3% - Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar PF a-si PV System PF mc-si PV System Fig.17 Production System Efficiency Factor a-si PV (%) (PF) and System System Efficiency mc-si (η SYS (%)) % 7. 6. 5..3 Final Yield (kwh/wp) 4. 3. 2. -.2 Performance Ratio 1. - -.7 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Dec Jan Mar Mar Yf of a-si PV Module System Yf of mc-si PV Module System PR of a-si PV System PR of mc-si PV System Fig. 18 Final Yield (Y f ) and Performance Ration (PR) of the experiment systems

International Journal of Renewable Energy, Vol. 2, No. 2, July 27 52 The a-si PV SHS with MPPT charger can deliver maximum power from PV module with precise maximum power track ability at most of the charging period while the mc-si PV SHS with on-off charger can not deliver maximum power form mc-si PV module due to the PV module voltage is determined by battery voltage which is different point that the PV module can delivery maximum power at most of charging period. The MPPT charger has lower efficiency than on-off charger for about 1% which make the Final energy yield (Y f ) and Performance Ratio (PR) of both system are about same. The SHS with a-si PV module can be improved to get higher Final energy yield(y f ) by adjusting charge set point since the MPPT charger reach boost charge at about noon and stop boost charge about 2 hours later which the boost charge set point can be increased to higher level and the boost charge time can be set to be longer for battery using in cycle use application such as solar home application. The charge efficiency of MPPT charger should be improve to gain more benefit form MPPT algorithm. The loss on DC to DC converter which is the most important loss in MPPT charger should be reduced to allow the system to charge battery with higher current and gain higher Y f which will make the SHS with a-si PV become attractive alternative SHS beside the system using crystalline silicon PV module. The system should have basic maintenance by refill distill water to maintain electrolyte of the battery since it can operate without maintenance on for only about 6 months before the storage efficiency is reduced to less than 5%. The difference of array yield (E A ) between a-si PV module and mc-si PV module is reduced when systems are installed and operate for 15 months. Acknowledgement Author would like to thank KANEKA Corporation, Japan for the close cooperation on experimental equipment and data which provided to SERT. This paper is an outcome of the joint research between KANEKA and SERT. References [1] International Energy Agency, Operational performance, reliability and promotion of photovoltaic systems, Report IEA-PVPS T2-3:22, 22. [2] International Energy Agency, Analysis of Photovoltaic Systems, Report IEA-PVPS T2-1:2, 2. [3] International Energy Agency, Recommend Practice for Charge Controller, Report IEA-PVPS T3-5:1998, 1998. [4] Photon Energy magazine Jan 6 issue [5] Sandia National Laboratories, Batteries and Charge Control in Stand-Alone Photovoltaic System-Fundamentals and Applications, January 15, 1997. [6] Mayer, D. and Heidenreich, M., Performance analysis of stand alone PV systems form a rational use of energy point of view. [7] Vervaart, M.R. and Nieuwenhout, F.D.J., Solar Home System: Manual for the design and modification of Solar Home System component, January 2. [8] David L. King, Jay A. Kratochvil, and William E. Boyson, Sandia National Laboratories, Fields Experience With A New Performance Characterization Procedure For Photovoltaic Arrays, July 6, 1998.