Series 756 FireLock Dry System Check Valve

Similar documents
Series 758 FireLock Actuated System Valve

Series 769 FireLock NXT Deluge Valve

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Series 751 FireLock European Alarm Check Valve Stations

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

Vic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730

Style 99 Roust-A-Bout Couplings

Series W706 AGS Butterfly Valves (300 PSI/2065 kpa)

Grooved Piping System for Fire Protection Services

Series 709 Butterfly Valves (175 psi/1270 kpa)

Series 706 Butterfly Valves (300 PSI/2065 kpa)

Series W709 AGS Butterfly Valves (175 psi/1270 kpa)

Grooved Piping System for Fire Protection Services

B NPT. Dimensions Inches/millimeters

Victaulic Specification Power Industry

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

Fire Protection Price List

Pressfit System for Carbon Steel Pipe

TotalPac 3 Non interlock Preaction system Pneumatic release

TotalPac 3 Deluge system Pneumatic release

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Fire Protection Price List. Piping. Systems. Solutions A FP.

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

DELUGE VALVE DATA SHEET

Instructions for Installation, Operation Care and Maintenance

TECHNICAL DATA. Q= C v P S

REQUEST PUBLICATION 18.11

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Instructions for Installation, Operation, Care and Maintenance

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Stainless Steel Pipe System. System No. Submitted By Spec Sect Para Location Date Approved Date TEMPERATURE ( F/ C)

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

TotalPac 3 Deluge, Electric release Remote controlled system

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA CAUTION

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

70.03 Victaulic Vortex TM

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

Section M Dry Pipe Systems

TECHNICAL DATA. Trimpac 249a. September 16, 2013

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

Size Inches UL ULC FM. Pipe Sch.

Features 1. Differential Latch-type, lightweight, dependable

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING CONTROL VALVE

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

BS 5163 Resilient Wedge Gate Valve

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

TotalPac 3 Firecyle III Wet pipe Remote controlled system

VICTAULIC Shouldered Solutions

Sludge Dewatering and Odor Control at Plant 1 CONFORMED

I-NXT.RBKIT 5-Year Rebuild Kit Instructions for FireLock NXT Valves

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

Q= C v P S. Flow control valve Model j-2 Halar coated

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

FIRE PROTECTION PRODUCTS

Instructions for Installation, Operation, Care, and Maintenance

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Deluge Valves. Model 68 DE\ HRV-MR. Hydraulically Actuated, Anti-Columning, Manual-Reset Deluge Valve. Dorot Fire Protection Division

Easy Riser swing check valve Models E-1 & F-1

From the world s leader in mechanical piping systems... The complete system for stainless steel piping.

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

Section R Foam Systems

Model DDX Deluge Valve 8 (200mm) Features

Section R Foam Systems

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

High Pressure 2-way 2 1/2-6 Globe Valves

Victaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only

Valves & Flow Control Components Valves & Flow Control Components

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Worldwide Contacts.

PRESSURE REDUCING VALVE

with the specific application. Always read and understand the installation

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

08.08 Vic-Check Valves

11.02 Mechanical-T Bolted Branch Outlets

TECHNICAL DATA OBSOLETE

Deluge Pressure Reducing Valves. Model 68 DE\ RCL\ PR. Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

Transcription:

R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS Series FireLock Dry System Check Valve Grooved X Grooved and Flanged X Grooved 0.0 VICTAULIC IS AN ISO 900 CERTIFIED COMPANY PRODUCT DESCRIPTION The Victaulic Series Dry Valve is a low differential, latched clapper valve that separates system water supplies from dry-pipe sprinkler systems. The positive latching mechanism uses the supply s water pressure from upstream (city side) of the control valve to hold the clapper shut. The supply water pressure on the latch is controlled by a relatively low system air pressure. When the system air pressure is released, such as an open sprinkler, the decreasing air pressure activates the dry actuator and releases the latch mechanism, which allows the clapper to open. U L FM U L C See Victaulic publication.0 for details. The low differential, unique latch, and actuator design of the valve allows the valve to be reset without opening the valve. The low differential design is not subject to water columns. The valve allows the water to operate a water motor alarm and/or electric pressure alarms, which continue until the flow of water stops. With the optional accelerator, the valve can be configured to respond faster for use in larger systems, or where faster response times are required. The valve is rated to 00 psi (0 kpa) water working pressure for sizes / - " (0-0 mm) and psi (0 kpa) water working pressure for size " (00 mm). The valve is factory tested hydrostatically to 00 psi ( kpa) for sizes / - " (0-0 mm) and 0 psi ( kpa) for size (00 mm). Air pressure to water pressure ratio is approximately to. The Series is available grooved X grooved (all sizes) or flanged X grooved ( - "/0-00 mm). The valve can be installed vertically or horizontally. Standard grooved dimensions conform to ANSI/AWWA C0, and standard flanged dimensions conform to ANSI B., Class 0. The Victaulic Series Dry Check Valve is made of high-strength, low-weight ductile iron, and it offers easy access to all internal parts. All internal parts are replaceable. Maintenance and service can be performed without removing the valve from its installed position. The rubber clapper seal is replaced easily without removing the clapper from the valve. The valve is painted inside and out to increase corrosion resistance. The body is tapped for main drain and all available trim configurations. Trim includes an alarm test valve, which allows testing of the alarm system without reducing the system s pressure. The valve is available with separate trim kits, or it can be pre-trimmed for installation. Series Dry Check Valves are available bare, pre-trimmed, as a quick-riser (request publication 0.0) or in a Fire-Pac cabinet (request publication 0.). Piston Assembly Seal Latch Clapper Alarm Outlet Alarm Test Seat Exaggerated for Clarity REGISTERED TRADEMARK OF VICTAULIC COPYRIGHT 00 VICTAULIC PRINTED IN U.S.A. 0 REV H Victaulic Company of America Phone: -00-PICK-VIC (-00--) Fax: -0- e-mail:pickvic@victaulic.com Victaulic Company of Canada Phone: 90-- Fax: 90--9 e-mail: viccanada@victaulic.com Victaulic Europe Phone:-9--00 Fax: -9-0- e-mail: viceuro@victaulic.be Victaulic America Latina Phone: -9-00 Fax: -9-0 e-mail: vical@victaulic.com Victaulic Asia Pacific Phone: --0 Fax: --0 e-mail: vicap@victaulic.com

DIMENSIONS D A B NOTE: Trim appearance may be different due to LPA. Dimensions remain the same. E H I F G C Nominal Dia. In./mm VALVE SIZE Actual Outside Dia. In./mm Dimensions Inches/mm Without Trim Aprx. Weight Each Lbs./kg A B C D E F G H I Flanged Grooved Flanged Grooved GROOVED X GROOVED With Trim /.900 9.00.00.00.00.00.00.00.00.00..0 0,,0 0 0, 9,. 9.00.00.00.00.00.00.00.00.00.0.0 0 0,,0 0 0, 9, /...00.00 0.00.0.0.0.00.00..0,0 0,9 0 9 9 9, 9,, mm.000..00.00 0.00.0.0.0.00.00..0, 0,9 0 9 9 9, 9,.00..00.00 0.00.0.0.0.00.00..0 0,9 0,9 0 9 9 9 9, 9,.00.0 0.00.00.00.00.00.00 9.00.00.0 9.0 0,, 0 0 0 9,9,..00..00.00.00.00.0.00.00.0.0 0, 0,0 0 9 0,,, mm.00.00..00.00.00.00.0.00.00.0.0, 0,0 0 9 0,,..0.0.00.00.00.00.00 9.0.00.0.0 00 9,,0 0 0 0,, GROOVED X FLANGED.00. 0.00.00.00.00.00.00 9.00.00.0.0 0, 9, 0 0 0 9 9,,..9..00.00.00.00.0.00.00.0.0 0, 0, 0 9 0,,, mm.00.9..00.00.00.00.0.00.00.0.0, 0, 0 9 0,,. 9..00.00.00.00.00.00 9.0.00.0 9.0 00 9, 9, 0 0 0 0,, Series FireLock Dry System Check Valve

PERFORMANCE.0.0.0.0 HYDRAULIC FRICTION LOSS FLOW OF WATER AT + F (+ C) THROUGH FULL OPEN VALVE SERIES // PRESSURE DROP PSI.0.0 0.9 0. 0. 0. 0. 0. ¹ ₂" " " ¹ ₂" &, mm " " &, mm " 0. 0. 0. 0 0 0 0 0 0 00 00 00 00,000,000,000,000,000 0,000 00,000,000 The chart below expresses the frictional resistance of Victaulic Series Dry Check Valve in equivalent feet of straight pipe. FRICTIONAL RESISTANCE FLOW RATE GPM Nominal Size Inches/ Actual mm Equivalent Length of Pipe Feet Nominal Size Inches/ Actual mm Equivalent Length of Pipe Feet / 9 /, mm, mm 0 MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-, grade --. Ductile iron conforming to ASTM A-9, grade --, is available upon special request. 9 9 Clapper: Aluminum bronze UNS-C900 or UNS-C000 Shaft: Stainless - Seat Seal: EPDM, ASTM D000 Clapper: Nitrile 0 Seat O-rings: Stainless steel (00 Series) BILL OF MATERIALS Valve Body Bolt Seal Cover Plate Bolts (Qty. ) Clapper 9 Clapper Spring Piston Clapper Seal Spacers (Qty. ) Piston O-ring Seal Ring Clapper Shaft Latch Seal Washer Clapper Shaft Retaining Plug (Qty. ) 9 Latch Spring Seal Retaining Ring Cover Plate 0 Latch Shaft Seal Assembly Bolt Cover Plate Gasket Latch Shaft Retaining Plug (Qty. ) Series FireLock Dry System Check Valve

TRIM PACKAGES Trim packages available: Vertical trim for the Series dry check valve installed vertically. Trim components are galvanized. Optional: Black trim for use on foam systems Trim packages include: Series -A Dry Actuator/Anti-Flood Device - Allows decreasing air pressure to release the latch mechanism, allowing the clapper to open. Request 0.0 for submittal.. All required pipe and fittings.. All standard trim accessories.. All required gauges. OR Series Low Pressure Actuator - Features a single trip point that allows the sprinkler system to operate with a low air or gas pressure. Request 0. for submittal.. All required pipe and fittings.. All standard trim accessories.. All required gauges. Optional accessories: Series Dry Accelerator - Required when the Series dry check valve is installed in large systems where response time of the system needs to be improved. Includes accelerator/anti-flood device and required trim. Request 0. for submittal. Series 0 Water Motor Alarm - The Series dry check valve is designed to activate a mechanical water motor alarm when a sustained flow of water (such as with an open sprinkler) causes the clapper to lift from its seat. Request submittal 0.. Alarm and supervisory pressure switch - The Series dry check valve is designed to allow the installation of pressure switches to activate electric alarms and control panels when a sustained flow of water (such as with an open sprinkler) causes the clapper to lift from its seat. Series D Water Column Device Series B Supplemental Alarm Kit Air Maintenance Trim Assembly - See page. For Air Compressors and Accessories, contact Victaulic. NOTE: If valve is to be used in foam system, black trim must be ordered per NFPA requirements. Please specify choice on order. NOTE: Valve is available pre-trimmed as a Vic-Quick Riser or in a Fire-Pac configuration. Series FireLock Dry System Check Valve

RECOMMENDED AIR PRESSURES FOR SERIES DRY VALVES WITH SERIES -A DRY ACTUATORS (INSTALLED WITH OR WITHOUT SERIES DRY ACCELERATORS) NOTES: The Victaulic air regulator is a relief-type design. Any pressure in the system that is above the set point of the regulator will be released. Therefore, charging the regulator above the set point could cause premature operation of a valve installed with a Series Dry Accelerator. For base or riser-mounted compressors, the recommended air pressures are the "on" or "low" pressure settings for the compressor. For tank-mounted compressors, the recommended air pressures are the set point for the air regulator. The on pressure of the compressor should be at least psi ( kpa) above the set point of the regulator. These pressures involve an -to- water-to-air ratio, plus a -pound safety factor. EXAMPLE: For a system with an underground pressure of 0 psi ( kpa): Per the chart above, the pressure should be set at 0. In addition, this pressure could be calculated by dividing the system s maximum water pressure by and then adding psi (9 kpa). Air Pressure - psi 0 0 0 0 0 Maximum Water Supply Pressure - psi (Peak) Proper Air Supplies for Series Dry Valves Used with Series -A Dry Actuators Only: 0.0 When a riser or base-mounted air compressor supplies air to a system using a Series -A Dry Actuator, it is not necessary to use the air maintenance trim assembly with an air regulator. In this case, the airline of the compressor connects to the trim at the fitting where the air maintenance trim is normally installed. Due to the large on/off differential available for pressure switches that control base-mounted compressors, adjust the compressor s pressure switch so that the "ON" contact is at the recommended air supply for the valve. Proper Air Supplies for Series Dry Valves Used with Series -A Dry Actuators and Series Dry Accelerators: When a Series Dry Accelerator is used with the Series -A Dry Actuator, the air maintenance trim assembly MUST be used with the air regulator. In the event that a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection for systems that use a Series Dry Accelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. Compressor Requirements NOTICE In the event that a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection for systems that use a Series Dry Accelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. If multiple dry valves are installed with a common air supply, isolate the systems by using a springloaded, soft seat-check valve to ensure air integrity for each system. Good practice is to include a control valve for isolation and service of each individual system. Required Flow Rate (CFM) 0 0 0 0 0 00 psi (9 kpa) 0 psi ( kpa) 0 psi ( kpa) psi (90 kpa) 0 00 0 COMPRESSOR REQUIREMENTS 00 0 00 0 00 0 00 0 00 0 900 System Capacity (in gallons) 90 00 0 0 0 00 0 00 0 00 0 00 Series FireLock Dry System Check Valve

RECOMMENDED AIR PRESSURES FOR SERIES DRY VALVES WITH SERIES LOW-PRESSURE ACTUATORS NOTES: The recommended air pressures, shown in the chart above, apply to a dry valve that uses a Series Low- Pressure Actuator at -psi (90-kPa) minimum and -psi (-kpa) maximum. If the air pressure is higher than -psi (-kpa), a Series Dry Accelerator should be installed. For base or riser-mounted compressors, the recommended air pressures are the "on" or "low" pressure settings for the compressor. For tank-mounted compressors, the recommended air pressures are the set point for the air regulator. The on pressure of the compressor should be at least psi ( kpa) above the set point of the regulator. The Victaulic air regulator is a relief-type design. Any pressure in the system that is above the set point of the regulator will be released. Therefore, charging the regulator above the set point could cause premature operation of a valve installed with a Series Dry Accelerator. AIR PRESSURE PSI 0 0 0 0 0 0 0 00 0 00 MAXIMUM WATER SUPPLY PRESSURE - PSI (Peak) Proper Air Supplies for Series Dry Valves Used with Series Low-Pressure Actuators When a riser or base-mounted air compressor supplies air to a system using a Series Low- Pressure Actuator, it is not necessary to use the air maintenance trim assembly with the air regulator. In this case, the airline of the compressor connects to the trim at the fitting where the air maintenance trim is normally installed (refer to the trim drawing). NOTE: The use of an air regulator with a base or risermounted compressor could cause short cycling, resulting in premature wear of the compressor. Due to the large on/off differential available for pressure switches that control base-mounted compressors, adjust the compressor s pressure switch so that the "ON" contact is set at psi (90 kpa). Proper Air Supplies for Series Dry Valves Used with Series Low-Pressure Actuators and Series Dry Accelerators When a Series Dry Accelerator is used with a Series Low-Pressure Actuator, the air maintenance trim assembly MUST be used with the air regulator. In the event a compressor becomes inoperative, a properly sized tank-mounted compressor provides the greatest protection for systems that use a Series Dry Accelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. Compressor Requirements NOTICE In the event that a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection for systems that use a Series Dry Accelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. If multiple dry valves are installed with a common air supply, isolate the systems by using a springloaded, soft seat-check valve to ensure air integrity for each system. Good practice is to include a control valve for isolation and service of each individual system. Required Flow Rate (CFM) 0 0 0 0 0 00 psi (9 kpa) 0 psi ( kpa) 0 psi ( kpa) psi (90 kpa) 0 00 0 COMPRESSOR REQUIREMENTS 00 0 00 0 00 0 00 0 00 0 900 System Capacity (in gallons) 90 00 0 0 0 00 0 00 0 00 0 00 Series FireLock Dry System Check Valve

AIR MAINTENANCE TRIM Series Regulated Air Maintenance Trim Assembly Series P Air Maintenance Trim Assembly with Pressure Switch BILL OF MATERIALS BILL OF MATERIALS Item Description Item Description / -inch (,-mm) Restrictor / -inch (,-mm) Restrictor Slow Fill Ball Valve (Normally Open) Pressure Switch Air Regulator Slow Fill Ball Valve (Normally Open) Strainer (0 Mesh) Fast Fill Ball Valve (Normally Closed) Spring-Loaded, Soft-Seated Check Valve Strainer (0 Mesh) Fast Fill Ball Valve (Normally Closed) Spring Loaded, Soft Seated Check Valve NOTES: Victaulic recommends using no more than two dry valves per air maintenance trim assembly. A Series regulated air maintenance trim assembly must be used with Series Dry Valves that are installed with Series Dry Accelerators. NOTE: If the valve contains a Series Dry Accelerator, the air maintenance device should be used with a tank-mounted compressor. The Series P Air Maintenance Trim Assembly with Pressure Switch is not acceptable for any system installed with a Series Dry Accelerator. When shop air or a tank-mounted air compressor is installed, the Series regulated air maintenance trim assembly must be used, instead of the Series P Air Maintenance Trim Assembly with Pressure Switch. The Series regulated air maintenance trim assembly provides proper air regulation to the sprinkler system. When a riser or base-mounted air compressor supplies air to a dry valve, it is not necessary to use the air maintenance trim assembly with the air regulator. In this case, the airline of the compressor connects to the trim at the fitting where the air maintenance trim is normally installed (refer to the trim drawing). Refer to the chart on the previous page for the recommended cut-in contact air pressure for systems installed with a Series -A Dry Actuator. These pressures involve an -to- water-to-air ratio, plus a - psi (0-kPa) safety factor. For systems installed with a Series Low-Pressure Actuator, the recommended minimum cut-in air pressure should be set at psi (90 kpa), regardless of the system supply pressure. The engineer/system designer is responsible for sizing the compressor so that it brings the entire system to the required pressure within 0 minutes. DO NOT oversize the compressor to provide more airflow, since it will slow down or possibly prevent valve operation. 9 Continuous service ( hours per day, days per week) is required to prevent the valve from false tripping due to a loss of air pressure. In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the greatest protection. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. Series FireLock Dry System Check Valve

OPERATION The Series Dry Check Valve contains a clapper, which has a replaceable rubber seal. The clapper makes contact with the valve s seat ring, which has access holes leading into an intermediate chamber in the valve. The piston contacts the latch, and the latch holds the clapper closed. In the closed position, the valve piston is maintained in the extended position by the water supply pressure from upstream of the water supply control valve. The valve piston holds the clapper in the closed position. The Series -A Dry Actuator/Anti-Flood Device maintains the water, and the system s air pressure controls the dry actuator. The air-to-water ratio is approximately to. Once the system s air pressure reduces to the trip point, the dry actuator opens and allows the water supply pressure in the piston to release (i.e. an open sprinkler). This release causes the piston rod to retract, and it permits the clapper to pivot freely, thus allowing water into the system. Water enters the intermediate chamber of the valve through the holes in the seat ring. The water flows from the intermediate chamber to the alarm line, which activates the system s alarms. The alarms continue to sound until the flow of water stops. When the flow of water stops, the spring-assisted valve clapper returns to the closed position. The valve acts as an alarm check valve until the system is back in service as a dry system, according to the proper procedure. This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box, Easton, PA 0-00 USA, Telephone: 00--9-00. Series FireLock Dry System Check Valve

0.0 TRIM Series Dry System Valve (Pressure Switch, Accelerator and Air Maintenance Trim OPTIONAL) Grooved X Grooved SERIES 0 WATER MOTOR ALARM ULC LISTED 0 FM F ³ ₄ Optional Series Dry Accelerator 9 To Alarm Line From Lower System Pressure Port To Drain From Piston Charge Line 9 Normally Open 0 Normally Closed To Drain Series D Water Column Kit (Optional) To Drain Optional Air Maintenance Device 0 To Drain TO DRIP CUP 9 Normally Open Water Supply Flanged Grooved BILL OF MATERIALS 9 Series FireLock Dry Valve Piston Charge Line Ball Valve (NO) Piston Charge Line Strainer (0 Mesh) Piston Charge Line Swing Check Valve Piston Charge Line Restrictor (¹ ₁₆") Piston Charge Line Pressure Gauge (0-00 psi/0-0 kpa) Gauge Valve Alarm Line Ball Valve (NO) Series 9 Drip Check Valve Alarm Test Line Ball Valve (NC) Alarm Line Drain Restrictor (¹ ₁₆") Alarm Line Drain Ball Valve (NC) Main System Drain Valve Main Drain Valve - Flow Test Drip Cup Drain Swing Check Valve Water Supply Pressure Gauge (0-00 psi/0-0 kpa) 9 0 9 0 Series 9 AutoDrain Series Ball Check Valve System Pressure Gauge (0-0 psi/0- kpa with retard) Air Line Strainer (0 Mesh) Air Line Restrictor (¹ ₁₆") Series A Dry Actuator Style 00 FireLock Rigid Coupling (Optional) Series 0W Butterfly Valve (Optional) Series Dry Accelerator Assembly Series 0 Water Motor Alarm (Optional) Series Air Maintenance Device (Optional) EPS- Alarm Pressure Switch (Optional) EPS-0 Supervisory Switch (Optional) Strainer (0 Mesh) Series D Water Column Kit (Optional) Series B Supplemental Alarm Device (Optional) NO = Normally Open; NC = Normally Closed This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Series FireLock Dry System Check Valve 9