Operation instructions Platform/floor scales

Similar documents
Operating Instructions School Balance

Operating Instructions Precision balance

Operating instructions Platform/floor scales

Operating instruction Compact balance

SAUTER TVO Version /2014 GB

Operating manual Platform/floor scales

Operating Instructions Precision balance


User Manual. PBA428 Weighing platform

KERN HFB Version GB

KERN HCB / HCN Version /2013 GB

Operating instructions Step-On Personal scale. KERN MPD_M Version /2015 GB

Instruction Manual Electronic Crane Scales. Logbook Regular maintenance and care KERN HUS/HUM Version /2011 GB

KERN HCB / HCN Version /2016 GB

KERN HTS-A Version /2014 GB

KERN HFD Version GB

KERN HFM Version /2010 GB

Operating manual FP-2. Index

KERN HFB Version /2012 GB

Instructions for use L 2015

KERN KFP_V20 Version /2012 GB

KERN HFO Version /2015 GB

KERN HFA Version /2015 GB

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

Operating instructions Medical Chair scale

Defender 3000 Series Base Instruction Manual

Ohaus ES Series Bench Scale

Compact Scales. Software Revision V1.25 & above

TriScroll TM 300 Series Dry Scroll Vacuum Pump

Operating manual Medical Stand assist scales

DUNE DCT SERIES Manual

N CX 5500 DAT Operating and Instruction manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Operating Instructions Personal weighing scale, Handrail scale, Bariatric scale, Wheelchair scale, Transportation stretcher balance

Quick Guide. brite Advanced Retail scale

Adam Equipment. TBB - TRIPLE BEAM Mechanical Balance Manual. 8141, RevD Nov2015 (ENG)

Operating manual Multi-function weighing balance

SSP-Series Portable Balances Operation Manual

This document hosted by: Operating Manual. Economical Precision Balances. CZ Series

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Adam Equipment. User Manual (EN) Pricing Retail RAV Series Adam Equipment Co. Ltd.

Service manual Precision balance

WOOOM INSTRUCTION MANUAL

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Operating and maintenance instructions

Operating Instruction for Electronic Pressure Switch. Model: PDD

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING)

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

c-go 24V/6A 24V/8A 24V/12A

3. Operating instructions: Minor 200

Operating instructions

AXIAL FANS Axis / Tubo OPERATION MANUAL

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

LHS/LHSa SERIES Manual

TYPE 41LA MINING LED LUMINAIRE EXPLOSION PROOF LUMINAIRE WITH FLAMEPROOF PROTECTION (TYPE d)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Crane fork KGM/KGA and KGQ/KGL

MOISTURE METER 2155 OPERATION INSTRUCTIONS VERSION 1.0

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Lumitester PD-30. Instruction Manual. Table of Contents

CORE SERIES (EN) SERIES CORE (FR) CORE SERIE (DE) SERIE CORE (ES) SERIE CORE (IT)

OPERATING INSTRUCTION

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Ulyser Component Maintenance Manual

Valor 2000 Series Instruction Manual

FLOX. Gebrauchsanweisung Operating instructions Manuel d instructions Instruzioni d uso Instrucciones de uso Gebruiksaanwijzing

TYPE NO. AS APPROPRIATE

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

KeContact P20. User manual

Operating Instructions

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Installation and Connection: Installation and Operating Manual

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

MS-4200/4201/4202/4202L USER MANUAL

VITLAB Dispenser. Standard Operating Procedure (SOP)

Operator s manual Manuel d utilisation Manual de instrucciones. BLi520x BLi940x

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

AP30 MkII Postal Scale INSTRUCTION MANUAL

Before using the new measuring rod, please take a little time to read the following safety instructions.

Catapult 1000 Series Instruction Manual

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

ECONOMY COUNTING SCALE OPERATION & SERVICE MANUAL

Compact Pressure Transmitter DAN-HH

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

KIT CONSISTS OF: FEATURES. S-Digit mini

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Operating Instructions

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

Transcription:

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operation instructions Platform/floor scales KERN EOB/EOE/EOS/BOBP Version 2.0 11/2006 GB

GB KERN EOB/EOE/EOS/BOBP Version 2.0 11/2006 Operation instructions Platform/floor scales Tabel of contents: 1 Technical data... 4 2 Declaration of conformty... 10 3 Appliance Overview... 11 4 Fundamental information (general)... 13 4.1 Intended use...13 4.2 Inappropriate use...13 4.3 Guarantee...13 4.4 Monitoring the test substances...14 5 Fundamental safety information... 14 5.1 Observe the information in the operating instructions...14 5.2 Staff training...14 6 Transport and storage... 14 6.1 Acceptance check...14 6.2 Packaging...14 7 Unpacking, installation and commissioning... 15 7.1 Place of installation, place of use...15 7.2 Installation...16 7.2.1 Unpacking the Balance... 16 7.2.2 Package volume... 16 7.2.3 Mounting instructions for using wall bracket... 17 7.3 Mains supply...17 7.4 Battery Operation...17 7.5 Initial start-up...18 7.6 Adjustment...18 7.7 Adjusting...18 8 Operation... 19 8.1 Weighing...19 8.2 Taring (TARE key)...19 8.3 Hold function (Animal weighing function)...20 2

8.4 Plus / Minus Weighings...20 8.5 Weight units...20 9 Maintenance, upkeep, disposal... 21 9.1 Cleaning...21 9.2 Maintenance, upkeep...21 9.3 Disposal...21 10 Troubleshooting... 22 EOB/EOE/EOB/EOS/BOBP-BA-e-0620 3

1 Technical data KERN EOB 6K5N EOB 15K10N EOB 35K20N EOB 60K50N Readout (d) 5 g 10 g 20 g 50 g Weighing range (Max) 6 kg 15 kg 35 kg 60 kg Reproducibility 5 g 10 g 20 g 50 g Linearity 10 g 20 g 40 g 100 g Recommended adjusting weight, not included (class) 5 kg 10 kg 20 kg 40 kg Stabilisation time (typical) Optimal temp. of operation Humidity 2-3 sec. + 10 C... + 35 C max. 80 % (non-condensing) Size (W x D x H) mm 310 x 300 x 55 (platform) 210 x 110 x 45 (terminal) 310 x 300 x 55 (platform) 210 x 110 x 45 (terminal) Weighing plate mm 310 x 300 Weight kg (net) 4 4

KERN EOB 60K50NL EOB 150K100N EOB 150K100NL EOB 150K100NXL Readout (d) 50 g 100 g 100 g 100 g Weighing range (Max) 60 kg 150 kg 150 kg 150 kg Reproducibility 50 g 100 g 100 g 100 g Linearity 100 g 200 g 200 g 200 g Recommended adjusting weight, not included (class) 40 kg 100 kg 100 kg 100 kg Stabilisation time (typical) Optimal temp. of operation Humidity Size (W x D x H) mm Stainless steel weighing plate (mm) platform: 550 x 550 x 65 terminal: 210 x 110 x 45 2 3 sec. + 10 C... + 35 max. 80 % (non-condensing) platform: 310 x 300 x 55 terminal: 210 x 110 x 45 platform: 550 x 550 x 65 terminal: 210 x 110 x 45 platform: 945 x 505 x 65 terminal: 210 x 110 x 45 550 x 550 310 x 300 550 x 550 945 x 505 Weight kg (net) 15 4 15 22,0 EOB/EOE/EOB/EOS/BOBP-BA-e-0620 5

KERN EOB 300K100N EOB 300K200NL EOB 300K200NXL Readout (d) 100 g 200 g 200 g Weighing range (Max) 300 kg 300 kg 300 kg Reproducibility 100 g 200 g 200 g Linearity 400 g 400 g 400 g Recommended adjusting weight, not included (class) 200 kg (M2) 200 kg 200 kg Stabilisation time (typical) 2-3 sec. Optimal temp. of operation + 10 C... + 30 C Humidity max. 80 % (non-condensing) Size (W x D x H) mm platform: 310 x 300x 55 terminal: 210 x 110 x 45 platform: 550 x 550 x 65 terminal: 210 x 110 x 45 platform: 945 x 505 x 65 terminal: 210 x 110 x 45 Stainless steel weighing plate (mm) 310 x 300 550 x 550 945 x 505 Weight kg (net) 4 15 22,0 6

KERN EOE 150K100L EOE 150K100XL EOE 300K200L EOE 300K200XL Readout (d) 100 g 100 g 200 g 200 g Weighing range (Max) 150 kg 150 kg 300 kg 300 kg Reproducibility 100 g 100 g 200 g 200 g Linearity 200 g 200 g 400 g 400 g Recommended adjusting weight, not included (class) 100 kg 100 kg 200 kg 200 kg Stabilisation time (typical) Optimal temp. of operation Humidity Size (W x D x H) mm Weighing platform, lacquered ( mm) platform: 505 x 505 x 65 terminal: 210 x 110 x 45 2-3 sec. + 10 C... + 35 C max. 80 % (non-condensing) platform: 945 x 505 x 65 terminal: 210 x 110 x 45 platform: 505 x 505 x 65 terminal: 210 x 110 x 45 platform: 945 x 505 x 65 terminal: 210 x 110 x 45 505 x 505 945 x 505 505 x 505 945 x 505 Weight kg (net) 14 22,0 14 22,0 EOB/EOE/EOB/EOS/BOBP-BA-e-0620 7

KERN EOS 150K100NXL EOS 300K200NXL Readout (d) 100 g 200g Weighing range (Max) 150 kg 300kg Reproducibility 100 g 200 g Linearity 200 g 400 g Recommended adjusting weight, not included (class) Stabilisation time (typical) Optimal temp. of operation Humidity Size (W x D x H) mm Stainless steel weighing plate (mm) 100 kg 200 kg 2-3 sec. + 10 C... + 35 C max. 80 % (non-condensing) 900 x 550 x 65 (plattform) 210 x 110 x 45 (terminal) 900 x 550 x 65 Weight kg (net) 22,5 8

KERN BOBP 300K200 BOBP 750K500 Readout (d) 200 g 500 g Weighing range (Max) 300 kg 750 kg Reproducibility 200 g 500 g Linearity 400 g 1000 g Recommended adjusting weight, not included (class) 200 kg 500 kg Stabilisation time (typical) Optimal temp. of operation Humidity Size (W x D x H) mm 2-3 sec. + 5 C... + 35 C max. 80 % (nicht kondensierend) 1000 x 1000 x 90 (Plattform) 210 x 110 x 45 (Terminal) Weighing plate mm 1000 x 1000 x 90 Weight kg (net) 50,5 EOB/EOE/EOB/EOS/BOBP-BA-e-0620 9

2 Declaration of conformty KERN & Sohn GmbH D-72322 Balingen-Frommern Postfach 4052 E-Mail: info@kern-sohn.de Konformitätserklärung Tel: 0049-[0]7433-9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de Declaration of conformity for apparatus with CE mark Konformitätserklärung für Geräte mit CE-Zeichen Déclaration de conformité pour appareils portant la marque CE Declaración de conformidad para aparatos con disitintivo CE Dichiarazione di cofnromitá per apparecchi contrassegnati con la marcatura CE English Deutsch Français Español Italiano We hereby declare that the product to which this declaration refers conforms with the following standards. Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt. Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après. Manifestamos en la presente que el producto al que se refiere esta declaración est a de acuerdo con las normas siguientes Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate. Platform Scale: KERN EOB/EOE/EOS/BOBP Mark applied EU Directive Standards 89/336EEC EMC EN 61000-6-3 : 2001+A11 :2004 EN 61000-6-1 : 2001 Date: 17. Nov. 2006 Signature: Gottl. KERN & Sohn GmbH Management Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149 10

3 Appliance Overview EOB models, stainless steel weighing plate EOB models with stand (option), only models with weighing plate 310 x 300 EOE models, weighing plate, lacquered EOB/EOE/EOB/EOS/BOBP-BA-e-0620 11

EOS models, Stainless steel weighing plate BOBP models 12

4 Fundamental information (general) 4.1 Intended use The balance you have acquired serves to determine the weighing value of the material to be weighed. It is intended to be used as a non-automatic balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. The weighing value can be read off after a stable weighing value has been obtained. 4.2 Inappropriate use Do not use the balance for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the stability compensation in the balance. (Example: Slowly draining fluids from a container on the balance.) Do not leave a permanent load on the weighing plate. This can damage the measuring equipment. Be sure to avoid impact shock and overloading the balance in excess of the prescribed maximum load rating (max.), minus any possible tare weight that is already present. This could cause damage to the balance. Never operate the balance in hazardous locations. The series design is not explosion-proof. Structural alterations may not be made to the balance. This can lead to incorrect weighing results, faults concerning safety regulations as well as to destruction of the balance. The balance may only be used in compliance with the described guidelines. Varying areas of application/planned use must be approved by KERN in writing. 4.3 Guarantee The guarantee is not valid following - non-observation of our guidelines in the operating instructions - use outside the described applications - alteration to or opening of the device - mechanical damage and damage caused by media, liquids - natural wear and tear - inappropriate erection or electric installation - overloading of the measuring equipment EOB/EOE/EOB/EOS/BOBP-BA-e-0620 13

4.4 Monitoring the test substances The metrology features of the balance and any possible available adjusting weight must be checked at regular intervals within the scope of quality assurance. For this purpose, the answerable user must define a suitable interval as well as the nature and scope of this check. Information is available on KERN s home page (www.kernsohn.com) with regard to the monitoring of balance test substances and the test weights required for this. Test weights and balances can be adjusted quickly and at a reasonable price in KERN s accredited DKD calibration laboratory (return to national normal). 5 Fundamental safety information 5.1 Observe the information in the operating instructions Please read the operating instructions carefully before erecting and commissioning, even if you already have experience with KERN balances. 5.2 Staff training The device may only be operated and looked after by trained members of staff. 6 Transport and storage 6.1 Acceptance check Please check the packaging immediately upon delivery and the device during unpacking for any visible signs of external damage. 6.2 Packaging Please retain all parts of the original packaging in case it should be necessary to return items at any time. Only the original packaging should be used for return consignments. Before despatch, disconnect all attached cables and loose/movable parts. 14

7 Unpacking, installation and commissioning 7.1 Place of installation, place of use The balance is constructed in such a way that reliable weighing results can be achieved under normal application conditions. By selecting the correct location for your balance, you will be able to work quickly and precisely. Therefore please observe the following at the place of installation: - Place the balance on a firm, level surface; - Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight; - Protect the balance against direct draughts due to open windows and doors; - Avoid jarring during weighing; - Protect the balance against high humidity, vapours and dust; - Do not expose the device to extreme dampness for longer periods of time. Inadmissible bedewing (condensation of air moisture on the device) can occur if a cold device is taken into a significantly warmer environment. In this case, please acclimatise the device for approx. 2 hours at room temperature after it has been disconnected from the mains. - Avoid static charging of the material to be weighed, weighing container and windshield. Major display deviations (incorrect weighing results) are possible if electromagnetic fields occur as well as due to static charging and instable power supply. It is then necessary to change the location. EOB/EOE/EOB/EOS/BOBP-BA-e-0620 15

7.2 Installation Install the balance in such a fashion that the weighing plate is absolutely horizontal. 7.2.1 Unpacking the Balance Carefully remove the balance from the packaging and out of the plastic covering, then place the balance on the assigned position. 7.2.2 Package volume Serial fittings: KERN EOB Platform (stainless steel weighing plate) and display device 4 x Adjusting feet (except platform 310 x 300) Mains device Wall bracket (with anchoring screws Operating instructions KERN EOE Platform and display device 4 x Adjusting feet Mains device Wall bracket (with anchoring screws Operating instructions KERN EOS Platform (stainless steel weighing plate) and display device 4 x Adjusting feet Mains device Rubber mat Wall bracket (with anchoring screws) Operating instructions KERN BOBP Platform and display device 4 x Adjusting feet Mains device Wall bracket (with anchoring screws Operating instructions 16

7.2.3 Mounting instructions for using wall bracket 7.3 Mains supply Electric power supply is by means of the external mains supply circuit. The printed voltage level must comply with the local voltage. Only use original KERN mains supply circuits. The use of other makes is subject to approval by Kern. 7.4 Battery Operation Remove the battery cover underneath the display. Connect 6 x 1,5V round cells. Reinsert the battery cover. Battery conservation through automatic power-off 3 minutes after ending a weighing operation. When the battery power is used up the display will show LO. Press the OFF key and change the batteries at once. When the balance is not in use for a longer period of time remove batteries and keep them separately. Leakage of battery liquid might damage the balance. EOB/EOE/EOB/EOS/BOBP-BA-e-0620 17

7.5 Initial start-up A warm-up time of 5 minutes stabilises the measured values after switching on. The accuracy of the balance depends on the local acceleration of the fall. Please be sure to observe the information in the chapter on adjusting. 7.6 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location ( only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out during the initial start-up, after change in location and variation of surrounding temperature. It is also recommendable to adjust the balance periodically during weighing operation in order to obtain exact measured values 7.7 Adjusting Balance accuracy can be checked and adjusted at any time using an adjusting weight. Method of adjusting: Observe stable ambience conditions. A short warming-up time of approx. 5 minutes for stabilisation purposes is useful. Press UNIT key and hold depressed until the exact size of the adjusting weight flashes on the display panel, Load appears on the display panel alternately. Place the adjusting weight in the centre of the weighing plate. Press UNIT key. The value of the size of the adjusting weight will stabilise a short time later. Keep the adjusting weight next to the balance. A daily balance accuracy check is recommended for applications relevant to quality. 18

8 Operation 8.1 Weighing Switch the balance on by pressing the ON/ key. The balance will show 88888 for approx. 3 seconds and then change to 0. Now it is ready for use. Important: If the display does not show 0 press the TARE key. Only now (!) place object on the weighing pan. Make sure that the weighing object does not stripe or touch the housing or base. Now the weight will be indicated. If the object should be heavier than the weighing range allowance, the symbol Err(overload) will appear on the display. 8.2 Taring (TARE key) Switch the balance on by pressing the ON key, then wait for the 0 indication. Place the jiffy on the weighing pan and press the TARE key. Display again shows 0. Now the weight of the jiffy is memorised internally. By pressing the TARE key after a weighing procedure, 0 will appear on the display again. The taring procedure can be repeated continuously, for instance when mixing several components. The limit is reached when the full weighing range is overlaid. After having removed the jiffy the total weight will appear as a minus indication. EOB/EOE/EOB/EOS/BOBP-BA-e-0620 19

8.3 Hold function (Animal weighing function) The balance has an integrated animal weighing function (mean value) with which it is possible to weigh small or domestic animals (minimum weight 1% of max.) precisely, even when they do not stand still on the weighing platform. Remark: With to lively movement (strong diplay fluctuation) no mean value can take place. Place the animal to be weighed on the weighing platform and press the HOLD key. A triangle will start to flash on the left hand side of the display, and during this time the balance will record several values, then calculate and display an mean value. By pressing the HOLD key again, the weighing machine will be reset to standard weighing mode. By pressing the HOLD key again, this function can be repeated as often as desired. 8.4 Plus / Minus Weighings For instance to control piece-weights, filling process control etc. Switch the balance on by pressing the ON key, then wait until 0 is indicated. Place rated weight on the weighing pan and tare on 0 by pressing the TARE key. Remove rated weight. Place the objects on the weighing pan successively, the balance will show any deviation from the rated weight in + and -. According to the same procedure packages with the same weight, related to a rated weight, can be produced. Return to the weighing mode by pressing the TARE key. 8.5 Weight units Two units are available: kg and lb. The weight unit is chosen by pressing the Unit key. A lamp to the right of the display signalises the respective unit. Unit conversion: 1 kg = 2.20462 lb 20

9 Maintenance, upkeep, disposal 9.1 Cleaning Please disconnect the device from the operating voltage before cleaning. Only use a cloth dampened with mild suds and not aggressive cleaning agents (solvents or similar). Please ensure that fluids are not able to get into the device and rub off using a clean, soft cloth. Loose sample residue/powder can be removed carefully using a brush or hand vacuum cleaner. Remove any spilt material to be weighed immediately. 9.2 Maintenance, upkeep The device may only be opened by trained service engineers authorised by KERN. Disconnect from the mains supply before opening. 9.3 Disposal The operating company shall dispose of the packaging and the device in compliance with the valid national or regional law of the operating location. EOB/EOE/EOB/EOS/BOBP-BA-e-0620 21

10 Troubleshooting The balance should be switched off for a short time following an interruption in the programme sequence and disconnected from the mains supply. It is then necessary to repeat the weighing process from the beginning. Help: Interruption Possible cause Weight display is not illuminated. The balance is not switched on. The mains supply connection has been interrupted (mains cable not plugged in/faulty). Power supply interrupted.. The weight display changes continually Draught/air movement Table/floor vibrations The weighing plate is in contact with foreign matter. Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) The weighing result is obviously incorrect The balance display is not set to zero Adjustment is no longer correct. Great fluctuations in temperature. Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Switch the balance off if other error messages should appear and then switch on again. Contact the manufacturer if the error message does not disappear. 22