Similar documents
GENERAL NOTE: GRADE 4-#8 AND 1-#8 EGC IN 1" CONDUIT TO POLE P2. 4-#8 AND 1-#8 EGC IN 1" CONDUIT TO POLE P1.

* * * DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CONSUMER ACCESS DIMENSIONS PLAN VIEW 19" DISPLAY FRONT ELEVATION

3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2") UL SAFE - 15" DISPLAY OR 19" DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION

STANDARD AND FULL HEIGHT - REAR LOAD - WITH 40mm (1 16") CEN I, CEN III GAS or CEN IV GAS SAFES

SAN ANTONIO RIVER AUTHORITY

1 SGI 500XT INVERTER TRANSFORMER WITH OUTDOOR ENCLOSURE CONDUIT, FITTINGS AND CONDUCTORS AS REQUIRED

AGNES SCOTT OBSERVATORY - SOLAR

TA25DU0.4 Overload Relay a. Features. Descriptions

SEE PAGES 3 AND 4 OF 7 FOR 3700 CASH RECYCLER THROUGH THE WALL WITH VESTIBULE TRIM KIT REFERENCE FRONT EDGE OF BEZEL FOR DEPTH DIMENSIONS

DIEBOLD 3750 CASH RECYCLER TERMINAL. 13mm ( 2") UL SAFE - 15" OR 19" DISPLAY THROUGH THE WALL 330mm (13") PLAN VIEW FRONT ELEVATION SECTION

* * * 3700 LOBBY CASH RECYCLER. REAR LOAD 13mm ( 2") UL SAFE - 15" DISPLAY OR 19" DISPLAY WITH DETAILS FOR OPTIONAL VESTIBULE INSTALLATION

DIEBOLD IN LOBBY TELLER (ILT) PORTRAIT OR LANDSCAPE INSTALLED WITH A COIN RECYCLER SIDE CAR PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7

COIN DISPENSER SIDE CAR FOR INSTALLATION NEXT TO DIEBOLD IN LOBBY TELLER (ILT) PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 7 CALL

CS 7780 FULL FUNCTION DRIVE-UP TERMINAL

DIEBOLD 3700 LOBBY CASH RECYCLER- FRONT LOAD 15" DISPLAY OR 19" DISPLAY CEN I, CEN III GAS, CEN IV GAS or CEN IV GAS EX SAFES

Central Purchasing 213 South Oliver Drive Aztec, New Mexico (505) Bid No , McGee Park Pavilion. County Executive Office

9900 IN LOBBY TELLER - (ILT) PORTRAIT AND LANDSCAPE DISPLAY PLAN FRONT VIEW SIDE VIEW PAGE 1 OF 6 CALL

E16DU, E45DU, E80DU, E140DU electronic overload relays 0.10 to 140 A

Electric underground service installation requirements

DPST-NO None 2 channels Auto-reset Inverse 24 VAC/VDC G9SB-2002-A 4 1 channel or 2


CS 7750 FULL FUNCTION TERMINAL 15" OR 19" DISPLAY - THROUGH THE WALL 330mm (13")

DIEBOLD 5550 CASH DISPENSER THROUGH 330mm (13") MAXIMUM WALL PLAN VIEW FRONT ELEVATION SIDE ELEVATION CONSUMER ACCESS DIMENSIONS

DC CONTACTOR. hubbell industrial controls, inc. Hubbell Industrial Controls, Inc. Type Ampere 1500 Volt DC Contactor

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

Two-Position Electric Duplex Room Thermostats

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT TYPICAL ACCESS TO LEVELING 15

Safety Relay Unit. Ordering Information. Ultra Slim Safety Relay

330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT. 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT NOTE: 203mm (8") MAXIMUM WALL THICKNESS IN AREA OF UNIT (2) EACH SIDE OF SAFE CEN I SAFE ONLY

LIGHTING CONSTRUCTION MANUAL CONTROL WIRING

HYDRANT & GATE VALVE INSTALLATION

OPTIONAL 178mm (7") SPACER AVAILABLE FOR WALL THICKNESSES UP TO 152mm (6") 330mm (13") MAXIMUM WALL THICKNESS IN AREA OF UNIT

Taxonomies, Classifications, and Categories THERMAL MAGNETIC, COMMON TRIP, EQUIPMENT PROTECTOR

R E V I S I O N REV. DRAWN BY ECO No DESCRIPTION DATE APPROVED BILL OF MATERIALS

Spring Return DuraDrive Two-Position Actuator

WATERTIGHT AIRTIGHT SPECIAL ACCESS DOORS & HATCHES, PART 1 GENERAL

Section 6. Transformers. Table of Contents. General Purpose, Dry Type, 600 Volts and Below. Industrial Control. Instrument, 600 Volt Class

POWER BUTTON: 25mm (1") CONDUIT X 3048mm (10'-0") LONG TO HOUSE POWER AND CONTROL CABLES (SUPPLIED BY DIEBOLD)

S»'94**gres* 6,=4.4.0 R\OF e.. S Z * 0 10.,5251, *S .//0/1111\\\\\\ VIWINCO INC. S-SERIES IMPACT AW/FIX STACKED 04/13/12

[1200mm] 5" [125 mm] 2 3/4" [70mm] [2600mm] [450mm]

Amendment Sheet. Code : ADB-FR Date : Superceded : nil REFRIGERANT CIRCUIT DIAGRAM

152mm (6") DIA. POINT TO POINT SYSTEM PVC OR STEEL TUBE SYSTEM TYPE I AND TYPE II OVERHEAD UNITS TYPE I OVERHEAD UNIT TYPE II OVERHEAD UNIT NOTES:

HOOK UP LAYOUT FOR HEAT GENERATION AND FUEL TANK SYSTEM

C&K 8020 Series Snap-acting Momentary Pushbutton Switches

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Signals\Wayne County Special Details\Develop

A u.060 PLASTIC VENT FAN SNAPPED IN PLACE u ±.062 SLOT VIEW (4) DIMENSIONS ARE FOR REFERENCE ONLY UNLESS TOLERANCE SPECIFIED

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

Automatic Outboard Flushing System 1.5

LOW VOLTAGE AIR SWITCH

8060 Series Alternate Action and Momentary Pushbutton Switches

8500 Series Subminiature Pushbutton Switches

Directional Control Valves. General Description. Features. Specifications

4%$ %%X 0RODUCT!PPLICATION 4HE "OTH 4%$ FOR 4%$ 80 DUSTTIGHT 2ATINGS

8020 Series Snap-acting Momentary Pushbutton Switches

8060 Series Alternate Action and Momentary Pushbutton Switches

SIDE DETAIL ELEVATION DETAIL JCM VIVA VISIO SYSTEM PRODUCT DATA -

Protector Series. Protector. Diesel Generator Set FEATURES

ALUMINUM ENTRANCE DOORS

C&K 8060 Series Alternate Action and Momentary Pushbutton Switches

R3( )RS: CALL OUT LAMPS FOR MURALS. EXISTING THEATRE REMOVE AND DISCARD CHANNEL LETTERS WITH NEON ILLUMINATION

Specifiable Features. Compatible with all UL 1686 listed plugs and receptacles. Type P Cable. Lockout Compliant. PowerMate Features and Benefits

Special School District of South County North County Technical High School Welding Lab Renovation 1700 Derhake Road St. Louis, Missouri 63033

O AND FAR SIDE VIEW A-A

C-TRAN MAINTENANCE BUILDING EXPANSION / SOUTH LOT IMPROVEMENTS

PROPORTIONAL DIRECTIONAL CONTROL VALVES PILOT OPERATED WITHOUT LVDT TYPICAL PERFORMANCE SPECIFICATIONS W/O LVDT, OPEN INNER LOOP MOUNTING SURFACE

Installation Instruction

00083FAB-DC DRAWN BY DATE CHK SCALE SIZE

RPEA3-06. Functional Description HA /2011. Directional Control Valves Solenoid Operated with 8W Coil. Replaces HA /2007

MNPV6 REV A DISCO 4X FINAL ASSY

Miscellaneous. Unit Substation, 600 Volts and Below. Industrial Control. Transformer Disconnects. Instrument, 600 Volt Class

TP Series Tiny Pushbutton Switches

Architecture - Engineering - Planning

F-Series General Specifications

ELECTRICAL SYSTEM 4 D INSTRUMENTATION

Vishay Dale Inductors

Lincoln Under-cabinet Light Installation Instructions

WARNING: IF THERE ARE ANY DISCREPANCIES BETWEEN THE CAD FILE AND THE DRAWING, THE DRAWING WILL TAKE PRECEDENCE. IF IN DOUBT, ASK.

SECTION A-A

631 ALLOWANES AND TOLERANCES

Service Disconnect(s) Type Circuits. from page 1-22

POWER COMBICON Plugs and Headers PC 6/ for Currents up to 41 A, mm Pitch

SHEET 1 OF 6

P3IC / P3ICP. Datenblatt. Absolute pressure transducer. Industrial Class" Special features. Dimensions (in mm) B en

Product Specification 12010E00 EQUALIZER AND 12010C00 CONVERTER, 12V TO 24V FAMILY

(mω) 1. Temperature ( C) Voltage (V) ULRG1 /

Varispeed E7 CIMR-E7Z. System Configuration

RETAINING BLOCKS Reinforcing Steel R-5236HC 52" (1,320 mm) Hollow Core Retaining Block

Product Specification 21XXXE00 EQUALIZER AND 21XXXC00 CONVERTER FAMILY

4/2- and 4/3-way shut-off valve

STANDARD CONSTRUCTION DETAILS STORM DRAINAGE REVISED - MAY 2017 DEPARTMENT OF ENGINEERING

Product Specification 120XXE00 EQUALIZER AND 120XXC00 CONVERTER, 12V TO 24V FAMILY

CASEMENT - LARGE MISSILE IMPACT

ABB industrial drives. Mechanical installation instructions ACS880 multidrive cabinets

OUTDOOR LIGHTING


Molded Interior Door Cambridge. Product Detail Sheets Table of Contents

PIPE SUPPORTS IRANIAN PETROLEUM STANDARDS COVER SHEET B A REV. DRAWING No. DATE DATE IPS-D-AR-012 DESCRIPTION

REMOVABLE MOUNT INSTALLATION FOR TRUCK BODIES For truck bodies only, not for trailers. Recommended for use with Dump Beds. See Drawing F.

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

Transcription:

GREGORY RD PROPERTY LINE (PPROX.) LEGEND LIGHTING CONTROL CENTER 50W METL HLIDE FLOODLIGHT GROUND MOUNTED JUNCTION BOX PROPERTY LINE (PPROX.) UNDERGROUND CONDUIT WITH CONDUCTOR, SIZE S SHOWN. 50W METL HLIDE LUMINIRE PROPERTY LINE (PPROX.) () 1-1/" C. W/ 6#8, 1#8 GND NEW ELECTRIC 1-1/" C. W/ #8, 1#8 GND SERVICE PEDESTL EXISTING UTILITY SERVICE POLE FIXTURE IMING NGLE FIXTURE IMING NGLE FIXTURE IMING NGLE FIXTURE IMING NGLE # TRIPLEX OVERHED BY KCPL SIGN SEE SHEET CO FOR BOX REQUIREMENTS LIGHT POLE 1-1/" C. W/ #8, 1#8 GND LIGHT POLE WLDO MONUMENT BY OTHERS 1-1/" C. W/ #8, 1#8 GND 1-1/" C., CPPED FOR FUTURE USE SHELTER KIOSK SEE EO SHEET FOR BOX REQUIREMENTS 1-1/" C. W/ #8, 1#8 GND WORNLL RD N 0 0 K:\NETJOB\71-00\DESIGN\XXXXXXXX.DWG 04/5/08 DTE REVISIONS ND RECORD OF ISSUE NO. BY CK PP DUBOIS CONSULTNTS CIVIL & STRUCTURL ENGINEERING HNTB Corporation Engineers rchitects Planners 715 KIRK DRIVE KNSS CITY, MISSOURI 645 PH (816) 47-1 FX (816) 47-996 Dubois Consultants Civil & Structural Engineering 5737 SWOPE PRKWY KNSS CITY, MISSOURI 64130 PH (816) 333-7700 FX (816) 333-77 DESIGNED CHECKED Taliaferro & Browne, Inc. Consulting Engineering - Landscape rchitecture Surveying 818 GRND BOULEVRD, SUITE 00 KNSS CITY, MISSOURI 646 PH (816) 83-3456 FX (816) 83-08 JGR DTE /01/11 DETILED FDH DTE /01/11 JGS DTE /01/11 DRWN FDH SCLE S SHOWN KNSS CITY RE TRNSPORTTION UTHORITY - KNSS CITY, MISSOURI TROOST VENUE BUS RPID TRNSIT STTIONS WORNLL RD. ND GREGORY RD. SITE ELECTRICL SCLE IN FEET HORIZONTL SCLE 1"= T & B Project No. 71-00 drawing: E1.dgn DWG NO. E1

K:\NETJOB\71-00\DESIGN\XXXXXXXX.DWG 04/5/08 E01 POWER PRODUCTS, INC. 75 E. HRRISON CORON, C 9879 951-50-1900 MEUG16-M0-KCMO /40 VC SEE MIN BREKER HNDLE 1 PHSE 3 WIRE 0 MPS MXIMUM INDUSTRIL CONTROL-SUITBLE ONLY FOR USE S SERVICE EQUIPMENT. RINPROOF TYPE 3R. METER SOCKET 0 MPS CONTINUOUS. "WTTHOUR METER NOT INCLUDED IN THE SHORT-CIRCUIT CURRENT RTING" UTILITY TERMINTION SECTION LIGHTINING RRESTER TEST UTO 0 / N 0B / SERV. DISC. 1 3 7 8 9 4 5 G 11 WIRE CONNECTORS: USE L/CU CONDUCTORS 6 1 B W EQUIPMENT GROUND TERMINTION: USE MORE THN ONE CONDUCTOR PER OPENING FOR EQUIPMENT GRD. ONLY. SYMBOL RNGE TORQUE: IN/LBS. #6-50MCM 50 3 4 5 6 #14- # 8 # 6-4 # 3-1/0 #14- # 8 # 6 3 36 41 45 18 3 3 NEUTRL (BONDED) 60 P "J" FUSE 30 P MERC. RLY C C SHIPPING TENDS TO LOOSEN ELECTRICL CONNECTIONS: CHECK TIGHTNESS BEFORE ENERGIZING! SIZE # -3 #1/4-0 #5/16-18 TORQUE (IN/LBS.) -15 50-60 60-70 GROUNDING ELECTRODE CONDUCTOR TERMINL SERV. GRD. T1 T T3 T4 INTERMEDITE HNDLE TRIP POSITION TO RESTORE POWER: TURN TO FULL OFF, THEN ON. PDB P BONDED NEUTRL, REMOVE BONDING MENS FOR TEST PURPOSES ONLY. CIRCUIT BREKERS 0 MPS OR LESS: WESTINGHOUSE BR,BRH,BQ,BD,GFCB,GFCBH,HQP,QPH,QP-GF: CROUSE-HINDS MP,MH,MP-GF; G.E. THQL,THQL-GF; ITE QP,QT,QPH. SHORT CIRCUIT RTING: RMS SYMMETRICL MPS,000 T /40 VC. THE SHORT CIRCUIT RTING IS LIMITED TO THE LOWEST INTERRUPTING CPCITY OF NY DEVICE INSTLLED THEREIN REPLCEMENT BREKERS MUST BE SME TYPE ND RTING. FIELD INSTLLED CONDUCTORS SHOULD OR MORE BSED ON TBLE 3-16 OF NEC. REPLCEMENT FUSES MUST BE SME TYPE ND RTING, CLSS "J", 60 MPS MX. 516861 P CIFIC U P TILITY RODUCTS RINPROOF-TYPE 3R RTING DETILS INSIDE "800-860-6157" 48.16 WITH DOOR STOP CONTROLLER-FRONT VIEW 1.8 LINE 11.0 LOD CONTROLLER-PLN VIEW E01.dgn 9.83 8.00 7.74 6. 6.04 7.75 DRW-PULL LTCH PD- LOCKBLE CUSTOM ER SECTION UTILITY PULL SECTION 15.30 HINGED TOP COVER METER SECTION 1 CONTROLLER-SIDE VIEW C140 Type C140 Type C140 Type C140 Type HNTB Corporation Engineers rchitects Planners 715 KIRK DRIVE KNSS CITY, MISSOURI 645 PH (816) 47-1 FX (816) 47-996 DTE REVISIONS ND RECORD OF ISSUE CK NO. BY PP DUBOIS CONSULTNTS CIVIL & STRUCTURL ENGINEERING Dubois Consultants Civil & Structural Engineering 5737 SWOPE PRKWY KNSS CITY, MISSOURI 64130 PH (816) 333-7700 FX (816) 333-77 DESIGNED CHECKED Taliaferro & Browne, Inc. Consulting Engineering - Landscape rchitecture Surveying 818 GRND BOULEVRD, SUITE 00 KNSS CITY, MISSOURI 646 PH (816) 83-3456 FX (816) 83-08 JGR DTE /01/11 DETILED FDH DTE /01/11 JGS DTE /01/11 DRWN FDH SCLE S SHOWN ELECTRICL MRKER POWER SOURCE EQUIPMENT KNSS CITY RE TRNSPORTTION UTHORITY - KNSS CITY, MISSOURI TROOST VENUE BUS RPID TRNSIT STTIONS T & B Project No. 71-00 drawing: DWG NO. 3 4 5 6 7 1 14 NORTH 13 16 15 11 8 9 CONTROLLER-FRONT VIEW SPECIFICTIONS * NEM 3R CONSTRUCTION * FBRICTED FROM.15 THK NTURL LUMINUM * FCTORY WIRING 600 VOLT RTED COPPER * LL EXTERIOR HINGES CONTINUOUS PINO TYPE * LL COMPONENTS RE U.L. LISTED. THIS INFORMTION IS PROPRIETY TO PCIFIC UTILITY PRODUCTS, INC. ND IS NOT DISCLOSED OUTSIDE OF PCIFIC UTILITY PRODUCTS, INC. WITHOUT CONFIDENTILITY GREEMENT. No. 1 LNDING LUGS 50kCMIL-6 MTR SOCKET 15 4J with 5th CLIP 3 MIN CB 0 P /40VC kic 4 LOD CENTER 15 1CKT 1-PHSE 5 (4) CB 30 P /40VC kic 6 (1) CB GFCI 0 1P VC kic 7 (1) CB 15 1P /40VC kic 8 (8) FUSE 60 CLSS J 600V BUSSMN 9 (4) CONTCTOR EH 30 3P SIEMENS LE (4) TERM BLK P 85 MRTHON 11 (1) RECEPTCLE 0 V DUPLEX 1 SWITCH TOGGLE SPST 0 13 PE RECEPTCLE 14 (1) SURGE RRESTER GE 15 BONDED NEUTRL BUS 16 INSULTED NEUTRL BUS COMPONENT DIRECTORY

PNEL CIRCUIT SCHEDULE HNDHOLE BSEPLTE OR BOLT COVERS ND NCHOR BOLTS SUPPLIED WITH POLE 1" CHM. NON SHRINK GROUT BETWEEN CONCRETE ND POLE BSE. DESIGNTION: MRKER PNEL VOLTGE: /40, SINGLE PHSE MOUNTING: INTERIOR BKR CIRCUIT ID V CKT NO. V CIRCUIT ID MIN 0 1 7 15 1 500 REL TIME SIGN () 8 BKR MP POLE MP POLE IC RTING:,000 MPS MIN BREKER: 50 MPS PNEL BUS: 0 MPS 0 1 SPRE LIGHT POLES (1) * 140 30 3 9 4 30" FINISHED GRDE OR PVEMENT 5 11 6 1 TOTL PHSE LOD = 1 V = 9.3 MPS 18" TOTL PHSE B LOD = 60 V = 5.1 MPS 7-0" * TO BE WIRED THROUGH LIGHTING CONTCTOR. CONDUIT PER PLNS 8#4 REBR VERT S EVENLY SPCED 18" DI. CONCRETE POLE BSE DETIL FOR TYPE POLES TYPE LIGHTING FIXTURE ND POLE SCHEDULE POLE BRCKET RM LMP MNUFCTURER MODEL NUMBERS PTRS30-75 //DB BOLT COVERS MTM-B/DB 50W METL HLIDE KIM LIGHTING FL3/50PMH40/DB (1) LIGHT POLES, SHELTERS, SIGN ND KIOSK LIGHTING SHLL BE PHOTO CELL CONTROLLED. () KIOSK REL TIME SIGN SHLL BE POWERED 4 HOURS. 3/8" - 16NC HEX BOLT w/ WSHER K F B C D J - 1/"x 1/" CURB & GUTTER 4" MIN JUNCTION BOX MOUSEHOLES PULL SLOT TYPE II ONLY SKID RESISTNT SURFCE LOGO TO BE "STREET LIGHTING" G H E SECTION - 8" MIN. LYER OF 1/" CLEN CRUSHED ROCK S PPROVED BY THE ENGINEER. COVER BOX JUNCTION BOX INSTLLTION DETIL TYPE B C DIMENSIONS (IN.) * D E F G H J K FIBERGLSS REINFORCED POLYMER CONCRETE JUNCTION BOX DETILS K:\NETJOB\71-00\DESIGN\XXXXXXXX.DWG 04/5/08 I II 1 7/81 7/8 18 1/ 11 1/ 3/4 3/4 DTE REVISIONS ND RECORD OF ISSUE NO. BY CK 14 14 0 1/13 1/ PP 1 3/4 1/ 1 DUBOIS CONSULTNTS CIVIL & STRUCTURL ENGINEERING 1/4 1/ 17 1/4 715 KIRK DRIVE 1 3/8 HNTB Corporation Engineers rchitects Planners KNSS CITY, MISSOURI 645 PH (816) 47-1 FX (816) 47-996 Dubois Consultants Civil & Structural Engineering 5737 SWOPE PRKWY KNSS CITY, MISSOURI 64130 PH (816) 333-7700 FX (816) 333-77 1 11 1/4 * TOLERNCE 1/4" IN NY DIMENSION Taliaferro & Browne, Inc. Consulting Engineering - Landscape rchitecture Surveying 818 GRND BOULEVRD, SUITE 00 KNSS CITY, MISSOURI 646 PH (816) 83-3456 FX (816) 83-08 DESIGNED JGS DTE 04/09/09 DETILED FDH DTE 04/09/09 CHECKED RLS DTE 04/09/09 DRWN FDH SCLE 1"= WORNLL ND GREGORY KNSS CITY RE TRNSPORTTION UTHORITY - KNSS CITY, MISSOURI TROOST VENUE STREETSCPE ELECTRICL MRKER PNEL SCHEDULES ND FIXTURE SCHEDULES T & B Project No. 71-0 drawing: E0.dgn DWG NO. E0