IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Similar documents
IN-LINE DUCT FANS MIXVENT-TD Fan Systems

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

CENTRIFUGAL IN-LINE FANS VENT Series

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

Practical examples of installation in the TD range

TD-ECOWATT AND DECOR-ECOWATT Series

ACOUSTIC CABINET FANS CVB / CVT Series

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

ACOUSTIC CABINET FANS CVAB / CVAT Series

TD-SILENT Series (160 to 1000 models)

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans

IN-LINE CENTRIFUGAL DUCT FANS VT Series

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

MIXVENT-TH Series Mixed Flow Fans

supplied in Form (B) configuration. Airflow over Impeller- Motor.

BATHROOM EXTRACT FANS DECOR-100 Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Short casing. Long casing (L version) Commercial premises

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web:

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

TD-SILENT range, the quietest fans in the world in their class

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

TD-SILENT range, the quietest fans in the world in their class

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

Shhhhhhhhhhh! Here there is silence.

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

Performance. Sound Levels. Impellers. Motors. Accessories

SILENT MV Ultra Quiet In-line Fans

GigaBox centrifugal fans Product specific information

Mixed Flow Roof Fans (RMH)

Sabre Plate Mounted Sickle Fans (VSP)

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Vent-Axia Sabre Sickle Roof Fans (VSR)

CVHT Series - F rated cabinet fans

Acoustic Twin Fans (ATQ)

Mixed Flow Roof Fans (RMH)

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

COMPACT Series type HCFB / HCFT (Plastic impellers)

Fan - Powered Terminal Unit Series Flow

Plate mounted axial flow fans HXBR / HXTR Series

Single-inlet centrifugal fans

plates and with flexible conduit. Ø Outlet (mm)

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

HIGH TEMPERATURE TWIN SQUIF FANS

Square Mixed Flow Fans (MFQ)

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

NEW Acoustic In-Line Fans (ACQ)

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

MegaBox Product-specific information

Uniclass L7534. Manufacture controlled to ISO9001

TGT Series Adjustable Pitch Fans

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Multifunctional 400ºC/2h and 300ºC/2h roof fans

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Axial fans. What s more, non-stock models are normally available within two weeks.

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

BELT DRIVEN CABINET FANS CVTT Series

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

TGT Series Adjustable Pitch Fans

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

CHMT Series, F Rated Fans

Sabre Sickle Fan Assisted Roof Cowls (VSR)

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Max. airflow m 3 /s Diam. min. Diam. max

NEW Slimpak EC Box Fan (SLPT EC)

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

KV sileo 100 M. Circular duct fans. Circular duct fans

AC Commercial Fans Edition. ErP ready

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

CGT Series Adjustable Pitch Fans

SINGLE DUCT TERMINAL UNITS

HIGH-POWERED VENTILATORS

Transcription:

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range of in-line fans. All MIXVENT TD fans include the combination of a powerful motor factory matched to a mixed flow impeller. This motor and impeller combination enables the MIXVENT- TD fans to deliver high airflow performances with the minimum of noise generation against high static pressures typically found in ducted ventilation systems. The unique design of the MIXVENT TD and TDx2 support brackets, allows the motor and Classic centrifugal In-line centrifugal MIXVENT flow impeller assembly to be fitted or removed without dismantling the adjacent ducting and therefore facilitating any installation or maintenance. The internal aerodynamic design of MIXVENT- TD fan enables the unit to generate large air volumes and pressures with the minimum of in-duct or radiated noise. An additional advantage of the MIXVENT TD fans is that they are fitted with direct connection two speed motors as standard. In addition, all motors are suitable for speed control regulation using electronic or auto-transformer controllers. The MIXVENT-TD fans offer the ideal in-line duct fan solution for a wide range of HVAC ventilation applications. The MIXVENT system includes 3 ranges of products: MIXVENT TD, Single Fan Unit MIXVENT TDx2, Twin Fan Unit MIXVENT TD-T, Twin Fan Unit with Overrun Timer The MIXVENT-TD consists of eight (8) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter circular ducting. The MIXVENT-TDx2 range consists of two MIXVENT TD fans mounted in series to produce almost twice the pressure of a single TD fan. The range consists of 5 nominal fan diameter sizes. The MIXVENT-TD-T consists of a range of five (5) nominal size TD fans (16, 25, 35, 5 and 8) fitted with an Run-On-Timer adjustable between 1 to 3 minutes. (The MIXVENT TD-T range is not suitable for speed control.) Accessories The MIXVENT System includes a specific range of accessories enabling the installation of different combinations of the MIXVENT TD and MIXVENT TDx2 fans, using models 35, 5, 8 and 1. These combinations include: MIXVENT Twin Two MIXVENT TD fans mounted in parallel using the Twin Base Kit. Mounting the fans in parallel produces double the duty of one fan (at the same pressure). MIXVENT Twin x 2 Two MIXVENT TDx2 fans mounted in parallel using the Twin Base Kit. Mounting the fans in parallel produces double the duty of a single TDx2fan (at the same pressure). MIXVENT Twin x 3 MIXVENT-TD and MIXVENT TDx2 mounted in series using the Flange (MBR). The pressure achieved by this arrangement will produce almost three times that of a single unit (at the same ar volume). To compliment the MIXVENT System a range of electrical and additional mechanical accessories are available to complete the most demanding installations. 29 The MIXVENT TD models are manufactured in tough reinforced plastic, except models 16, 1, 13 & 2 which have a metal casing and are finished in a tough epoxy-polyester paint coating. The TD fan duct connection flanges are manufactured from reinforced plastic, except for models 8, 1, 13 & 2 which are constructed from epoxy-polyester coated metal. Impellers The impeller blades are moulded in tough ABS plastic except models 8N, 1, 13 and 2 which are in metal. Motors Models 16, 25 and 35: Single-phase, 23V 5Hz, shaded pole induction asynchronous motor in die cast aluminium. All motors include direct two speed connection and are also suitable for voltage speed control*. Manufactured in accordance to standards UNE 2-113 and CEI 34-1. Class ll electrical insulation (model 16) and Class l (models 25 and 35) IP 44 Protection Class B Motor Insulation Safety Thermal Overload Protection (fuse type) Self-lubricating sleeve bearings. Models 5, 8, 1, 13 and 2: Single-phase induction asynchronous motor, with permanent capacitor and external rotor in die cast aluminium. All models include direct two speed connection and are also suitable for voltage speed control*. Manufactured in accordance with standards UNE 2-113 and CEI 34-1. Class I electrical insulation. IP 44 Protection Class B Motor Insulation Thermal Overload Protection Sealed For Life, ball bearings *Except TD-T models.

MIXVENT-TD / MIXVENT TDx2 Model Reference T D - 8 / 2 N T 1 2 3 4 1 Series reference 2 MIXVENT TD model type (Nom. max. m 3 /hr) 3 Nominal ducting connection diameter (mm) 4 Type where applicable Technical characteristics Nom. Maximum Maximum Duty at Maximum Sound Weight speed absorbed absorbed free operating pressure power at Pa current discharge temperature level* Model Type (r.p.m.) (W) (A) (m 3 /h) ( C) (db(a)) (kg) TD-16/1N 25 35,25 16 4 18 21 23,15 13 4 14 TD- 25/1 188 39,26 25 4 28 1475 26,18 185 4 23 TD- 35/125 221 56,37 36 4 3 19 4,26 3 4 26 15 25 68,3 535 6 41 TD-5/ 16 185 5,22 4 6 33 TD- 8/2N 27 8,35 97 6 41 21 7,3 7 6 36 TD-8/2 245 128,55 88 6 45 24 96,41 665 6 37 TD-1/25 28 155,65 11 6 49 21 85,39 85 6 43 TD- 13/25 252 17,72 13 6 49 199 11,48 95 6 44 TD-2/315 276 35 1,3 199 6 52 2,9 151 6 5 * Radiated sound level measured at 3 m from product casing at free air conditions. Technical characteristics Reference 1,4 2, 2, 2,7 4,9 4,9 9,4 9,4 14, T D x 2-8 / 2 N 1 2 3 4 1 Series reference 2 MIXVENT TD model type (Nom. max. m 3 /h) 3 Nominal ducting connection diameter (mm) 4 Type where applicable Nom. Maximum Maximum Duty at Maximum Sound Weight speed absorbed absorbed free operating pressure power at Pa. current discharge temp. level* Model Type (r.p.m.) (W) (A) (m 3 /h) ( C) (db(a)) (kg) TDx2-35/125 263 15 1,12 395 4 36 22 9,58 32 4 31 5,4 15 272 14,6 51 6 48 TDx2-5/ 16 23 1,44 415 6 41 5, TDx2-8/2N 28 165,72 9 6 48 245 14,6 69 6 44 8,7 TDx2-8/2 27 28 1,2 875 6 52 24 18 1,1 75 6 48 8,7 TDx2-1/25 28 3 1,3 12 6 57 21 17,78 85 6 51 18,7 TDx2-13/25 252 34 1,44 132 6 57 199 22,96 98 6 52 18,7 * Radiated sound level measured at 3 m from ducting product at free air conditions. 21

MIXVENT TD Performance curves Q = Air volume in, m 3 /hr and m 3 /s = High speed Pe = Static pressure in and Pa. = Low speed Dry air at 2 ºC and 76 mmhg. Air flow data in accordance with the following standards: UNE 1-212-89, BS 848, Part 1, AMCA 21-85 and ASHRAE 51-1985. 211

MIXVENT TD Performance curves Q = Air volume in, m 3 /hr and m 3 /s = High speed Pe = Static pressure in and Pa. = Low speed Dry air at 2 ºC and 76 mmhg. Air flow data in accordance with the following standards: UNE 1-212-89, BS 848, Part 1, AMCA 21-85 and ASHRAE 51-1985. 212

MIXVENT TDx2 Performance curves Q = Air volume in, m 3 /hr and m 3 /s = High speed Pe = Static pressure in and Pa. = Low speed Dry air at 2 ºC and 76 mmhg. Air flow data in accordance with the following standards: UNE 1-212-89, BS 848, Part 1, AMCA 21-85 and ASHRAE 51-1985. 213

MIXVENT SYSTEM - COMBINATIONS MIXVENT Twin Twin Twin with back-draft shutter accessories MIXVENT Twin x 2 Components Kit Twin Base-25 + 2 TD -16/1 Kit Twin Base-25 + 2 TD 25/1 Kit Twin Base-35 + 2 TD -35/125 Kit Twin Base-5/15 + 2 TD-5/15 Kit Twin Base-5/16 + 2 TD-5/16 Kit Twin Base-8 + 2 TD-8/2 Kit Twin Base-1 + 2 TD-1/25 Kit Twin Base-1 + 2 TD-13/25 Kit Twin Base-2 + 2 TD-2/315 For back-draft shutter see accessories. Components Kit Twin Base-35 + 2 TDx2-35/125 Twin x 2 Description Twin x 2 with back-draft shutter accessories Kit Twin Base-5/15 + 2 TDx2-5/15 Kit Twin Base-5/16 + 2 TDx2-5/16 Kit Twin Base-8 + 2 TDx2-8/2 Kit Twin Base-1 + 2 TDx2-1/25 Kit Twin Base-1 + 2 TDx2-13/25 For back-drauft shutter see accessories. Kit Twin Base MIXVENT TD x 3 Nominal dimensions of rectangular ducting L B H Model Type L x H (mm) Kit Twin base - 25 28 x 14 Kit Twin base - 35 28 x 14 Kit Twin base - 5 355 x 18 Kit Twin base - 8 4 x 2 Kit Twin base - 1/13 5 x 25 Kit Twin base - 2 63 x 315 The independent operation of two TD or TDx2 fans requires the use of back-draft shutters at the discharge (outlet) in order to prevent the air recycling through a stationary fan. Reference Model Type TDx3-35/125 TDx3-5/15 TDx3-5/16 TDx3-8/2 Components TD-35/125+TDx2-35/125+MBR-35 TD-5/15+TDx2-5/15+MBR-5/15 TD-5/16+TDx2-5/16+MBR-5/16 TD-8/2+TDx2-8/2+MBR-8 TDx3-1/25 TD-1/25+TDx2-1/25+MBR-1 TDx3-13/25 TD-13/25+TDx2-13/25+MBR-1 TD x 3: with MBR connection flange Description Flange MBR One fan only in operation Two fan in operation A B C A B C fan in use: A Direction of flow fan in use A and B or A and C Direction of flow 214

Performance curves Q = Air volume in, m 3 /hr and m 3 /s Pe = Static pressure in and Pa. Dry air at 2 ºC and 76 mmhg. Air flow data in accordance with the following standards: UNE 1-212-89, BS 848, Part 1, AMCA 21-85 and ASHRAE 51-1985. Pa Pa 6 Pe P mmce 6 MIXVENT TWIN 55 5 5 45 4 4 35 3 3 25 1 Twin 35 Twin x 2-35 TD x 3-35 2 Twin 5 Twin x 2-5 TD x 3-5 3 Twin 8 Twin x 2-8 TD x 3-8 4 Twin 1 Twin x 2-1 TD x 3-1 5 Twin 13 Twin x 2-13 TD x 3-13 Pa Pa PeP mmce 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 MIXVENT TWIN x 2 5 1 2 3 4 2 1 2 15 1 5 PeP Pa Pa mmce 1 1 9 8 7 6 5 4 3 2 1 1 2 5 1 2 9 8 7 6 5 4 3 2 1 2,1,2,3,4,5,7 MIXVENT TD x 3 1 2 3 3 4 4 5 5 m 3 /h Q m 3 /s 2 5 1 2,1,2,3,4,5,7 m 3 /h Q m 3 /s 1 2 3 5 1,5,1,2,3 m 3 /h Q m 3 /s 215

Acoustic characteristics Sound Power Level Spectrum (db(a) at octave average frequencies (Hz), measured at the fan discharge. Fan Type 125 25 5 1 2 4 8 TD-16/1 37 41 55 57 49 41 32 TD-25/1 37 48 57 59 55 49 4 TD-35/125 37 49 58 6 56 5 41 TD-5/15 39 55 62 63 65 58 46 TD-5/16 39 55 62 63 65 58 46 TD-8/2-N 43 62 59 62 63 58 47 TD-8/2 44 55 7 66 68 63 54 TD-1/25 43 57 67 73 73 67 55 TD-13/25 43 57 67 73 73 67 55 TD-2/315 46 6 7 75 75 69 58 Sound Power Level Spectrum (db(a) at octave average frequencies (Hz), measured outside the fan casing (radiated noise). Fan Type 125 25 5 1 2 4 8 TD-16/1 3 3 35 31 28 22 2 TD-25/1 3 4 46 45 35 28 21 TD-35/125 3 41 47 46 36 29 22 TD-5/15 33 5 51 59 54 42 36 TD-5/16 33 5 51 59 54 42 36 TD-8/2-N 36 57 48 58 52 41 37 TD-8/2 37 5 59 62 57 47 44 TD-1/25 36 52 56 69 62 51 45 TD-13/25 36 52 56 69 62 51 45 TD-2/315 39 55 59 72 65 54 48 Sound Power Level Spectrum (db(a) at octave average frequencies (Hz), measured at the fan discharge. Fan Type 125 25 5 1 2 4 8 Twin x 2-35 42 59 68 68 65 59 49 Twin x 2-5 48 66 74 69 75 65 54 Twin x 2-8 N 53 74 7 71 74 67 56 Twin x 2-8 55 7 81 78 79 74 63 Twin x 2-1 55 71 78 84 84 77 65 Twin x 2-13 55 71 78 84 84 77 65 Sound Power Level Spectrum (db(a) at octave average frequencies (Hz), measured outside the fan casing (radiated noise). Fan Type 125 25 5 1 2 4 8 Twin x 2-35 35 51 57 54 45 38 3 Twin x 2-5 41 61 63 65 64 49 44 Twin x 2-8 N 46 65 59 67 64 5 46 Twin x 2-8 48 65 7 74 68 58 53 Twin x 2-1 48 66 66 8 73 61 53 Sound Power Level Spectrum (db(a) at octave average frequencies (Hz), measured at the fan discharge. Fan Type 125 25 5 1 2 4 8 Twin x 3-35/125 45 57 66 63 6 56 45 Twin x 3-5/15 52 66 7 66 74 63 52 Twin x 3-5/16 52 66 7 66 74 63 52 Twin x 3-8/2 N 57 72 67 67 72 65 53 Twin x 3-8/2 59 66 71 73 76 71 6 Twin x 3-1/25 58 67 69 79 81 75 61 Twin x 3-13/25 58 67 69 79 81 75 61 Twin x 2-13 48 66 66 8 73 61 55 Sound Power Level Spectrum (db(a) at octave average frequencies (Hz), measured outside the fan casing (radiated noise). Fan Type 125 25 5 1 2 4 8 Twin x 3-35/125 35 51 57 54 45 38 3 Twin x 3-5/15 41 61 63 65 64 49 44 Twin x 3-5/16 41 61 63 65 64 49 44 Twin x 3-8/2 N 47 68 64 66 61 51 45 Twin x 3-8/2 48 65 7 74 68 58 53 Twin x 3-1/25 48 66 66 8 73 61 55 Twin x 3-13/25 48 66 66 8 73 61 55 216

MIXVENT-TD System Accessories Filtration Box MFL The MFL range of in-line heavy duty cabinet filters of type EU3 grade filtration are designed for direct connection with standard circular ducting. Pérdida Filter de carga pressure de loss filtros (Pa) (Pa) p(pa) 15 1 Ø D B E F Filter A B Ø D E F Type MFL-1 2 2 1 16 25 MFL-125 2 2 125 16 25 MFL-16 22 29 16 16 25 5 MFL-2 29 29 2 16 25 1 2 3 4 5 6 7m/s A MFL-25 32 34 25 25 38 Air speed MFL-315 38 42 315 27 41 MBE, Electrical Heater Batteries The MBE electric heater battery sections are designed to be installed on the discharge side of the MIXVENT-TD fans. The units incorporate insulated (black heat) element rods (23V 3W/cm 2 ) with an automatic integrated overheat thermostat (set at 9º C). This thermostat in turn is wired in series with an additional safety overheat manual reset thermostat (set at 12º C). In the case of the unit overheating the second thermostat will switch the unit off, after which the heater can then be Reset manually via the push button switch. All wiring terminations and connections are located on the side of the heater casing. The heaters are available for single phase (models MBE 1, 125 and 16) or three phase (models 2, 25 and 315) electrical supply connection in conjuntion with appropriate circuit protection. All units are supplied with an IP43 rated wiring enclosure. The minimum air velocity through the heater batteries must be >= 1.5 m/s. A range of controllers accessories to accompany the electric heater range are available. These controllers accessories modulate the heater output as a function of the required environmental temperature (see Electrical Accessories section of this catalogue). HEATER BATTERY SELECTION EXAMPLE DATA: Required air volume : 7m 3 /hr (Q) Temp. of air entering: +5º C Temp. required at discharge: +27º C HEATER BATTERY POWER REQUIRED: P = Q x.36 x DT P = 7 x.36 x (27-5) P = 5544 W SELECTION OF HEATER: MBE-2/5T or MBE-25/6T The final selection depends upon: Available space Total system pressure loss Sound level. Type Electric Heater Supply Min. Wiring Controller MIXVENT-TD heater power voltage air diagram* type type output volume (W) (V) (m 3 /h) 25/1 MBE-1/4B 4 1/23 5 E1 REG 6 35/125 MBE-125/12B 12 1/23 7 E1 REG 6 5/16 MBE-16/21B 21 1/23 11 E1 REG 6 8/2 MBE-2/5T 5 2/4 17 E2 REG 6 1-13/25 MBE-25/6T 6 2/4 27 E2 REG 6 2/315 MBE-315/9T 9 3/4 42 E3 REG 16 15 p(pa) 1 5 T (ºC) 5 4 3 2 1 Diferencia Temperature de temperatura difference entre T between el aire saliente air entry y el and aire discharge entrante ( C) T (ºC) 4 W 12 W 1 2 3 4 5 1 2 25 m 3 /h Velocidad Air del speed aire Pérdida Electric de heater carga de pressure las baterías loss p(pa) MBE - 315/9 21 W MBE - 2/5 y 25/6 MBE - 125/12 y 16/21 MBE - 1/4 5 W 1 2 3 4 5 6 7 8 9 m/s Velocidad Air del volume aire 6 W Dimensions (mm) 5 9 W 285 4 15 217

Installation accessories Back-Draft Shutters MCA Mounted at the outlet of the MIXVENT TD and TDx2 fans, the shutter prevents the air re-circulating when the fans are not in use. Type TD - TD x 2 - TD x 3 - TH MCA - 25 16/1N - 25/1 MCA - 35 35/125 MCA - 5/15 5/15 MCA - 5/16 5/16 MCA - 8 8/2-8/2N MCA - 1 1/25-13/25 MCA - 2 2/315 B Type A Ø B C Ø D D 25 17 111 31,5 94,5 35 17 136 31,5 119,5 5/15 121 163,5 35 147 5/16 121 173,5 35 157 8 131,5 214 35 197,5 C A 1/13 164 264,5 42 248 2 25 33 5 312 Rectangular Duct Adapters MAR The MAR adapter enables the MIXVENT TD, TDx2 or TDx3 to be connected to rectangular ducting. Nominal dim. Type TD-TDx2-TDx3 of ducting L x H MAR - 25 16/1N - 25/1 224 x 14 MAR - 35 35/125 224 x 14 MAR - 5/15 5/15 28 x 18 MAR - 5/16 5/16 28 x 18 MAR - 8 8/2-8/2N 315 x 2 MAR - 1 1-13/25 4 x 25 MAR - 2 2/315 5 X 315 F A E B ø G C Type A B C E F Ø G 25/1 264 18 33,3 16 244 9 35/125 264 18 33,5 16 244 9 5/15 32 22 37 2 3 9 5/16 32 22 37 2 3 9 8/2 355 24 37 22 335 9 1/25-13/25 44 29 42 27 42 9 2/315 54 355 52 355 52 9 Grilles MRJ Mounted at the inlet or outlet of the fan, the MRJ grille prevents the entry of any foreign objects. Type TD - TD x 2 - TD x 3 MRJ - 25 16/1N - 25/1 MRJ - 35 35/125 MRJ - 5/15 5/15 MRJ - 5/16 5/16 MRJ - 8 8/2-8/2N MRJ - 1 1/25-13/25 MRJ - 2 2/315 NEW SIL Sound attenuators Nom. diameter Ext. diameter Length Attenuation in db Type (mm) (mm) (mm) 125 25 5 1 2 4 SIL 125 125 224 6 5 13 21 37 37 31 SIL 16 16 28 6 3 11 22 33 42 29 SIL 2 2 315 6 4 8 15 31 28 2 SIL 25 25 355 6 6 9 13 24 15 15 SIL 315 315 5 9 7 9 16 3 18 14 218

Accessories REGUL 2 2 Speed switches REB Single-phase electronic speed controller RMB Single-phase auto-transformer speed controller. GSA Flexible aluminium ducting GSI Flexible Acoustic ducting CX Ducting Fixing clamps STC In-duct temperature sensor STA Ambient air temperature sensor BOC Circular air valves PER Outdoor plastic louvre shutters MRT RED Joining pieces and reducers Dimensions (mm) TD-16/1N TD-25 to TD-2 Ø 4,5 28 28 47,5 232 34 51,5 95,5 151 82 Ø 97 Ø 137,5 95 Model Type X A Ø B C Ø D E F G H TD-16/1N 151 232 137,5 96 98 82 95 47,5 131 TD- 25/1 188 33 176 115 97 1 9 8 6 TD- 35/125 188 258 176 115 123 1 9 8 6 TD- 5/15 212 295 2 127 147 112 13 8 6 TD- 5/16 212 275 2 127 157 112 13 8 6 TD- 8/2N 232,5 32 217 141 198 124 14 1 94 TD- 8/2 232,5 32 217 141 198 124 14 1 94 TD-1/25 291 386 272 192 248 155 168 145 14 TD-13/25 291 386 272 192 248 155 168 145 14 TD-2/315 356 45 336 224 312 188 21 182 178 219

TDx2 Dimensions (mm) X E ø 5,5 C F H D B G A Model Type X A Ø B C Ø D E F G H TDx2-35/125 188, 417 176 115 123 1 9 253 6 TDx2-5/15 212,5 464 2 127 147 111,5 13 249 6 TDx2-5/16 212,5 444 2 127 147 111,5 13 249 6 TDx2-8/2 232,5 5 217 141 198 124 14 298 94 TDx2-1/25 291, 654 272 192 248 155 168 416 145 TDx2-13/25 291, 654 272 192 248 155 168 416 145 Twin and Twin x 2 C F A M E N O D O2 D L L2 B Model Type A B C D E F L L 2 M N O O 2 Twin-25 32 18 184 36 16 3 35 375 113 8 Twin-35 32 18 184 33,5 16 3 35 475 333 91 8 253 Twin-5 (15) 395 22 26 37 2 375 31 481 417 11 8 249 Twin-5 (16) 395 22 26 37 2 375 29 461 417 1 8 249 Twin-8 44 24 225 37 22 42 317 59 456 13 1 298 Twin-1 54 29 282 44 27 52 41 679 566 123 145 416 Twin-13 54 29 282 44 27 52 41 679 566 123 145 416 Twin-2 69 355 347 53 335 65 451 699 136 182 TDx3 Model Type A G 1 G 2 L TD x 3-35/125 755 8 253 213 TD x 3-5/15 766 8 249 223 TD x 3-5/16 726 8 249 23 G2 A L G1 TD x 3-8/2 81 1 298 27 TD x 3-1/25 155 145 416 246 TD x 3-13/25 155 145 416 246 22

MIXVENT-TD FAN KITS TD-16/1N TD-25/1 TD-25/1T Description The TD ventilation kits enable the simple and fast installation of a complete ventilation system. The kits include the powerful TD in-line fan providing efficient extraction for bathrooms, toilets, washrooms and any other applications that require the removal of bad odours, stuffy and humid air. In addition to the fan the kits include an interior circular air valve (BOC-1); exterior mounted grille (GR-1); three meters of flexible aluminium ducting (GSA-1) and a roll of tough ducting tape to provide the complete hardware required for a given ventilation system. Extractor fans TD-16/1N TD-25/1 TD-25/1T The TD range of in-line fans incorporate powerful mixed flow impellers which enable efficient and very quiet extraction against the pressures caused by ducting and grilles. Model TD-25/1T incorporates a Run-On- Timer facility which can be adjustable between 1 to 3 minutes. (factory set to 15 mins) TD-16/1N TD-25/1 TD-25/1T The TD range has been specifically designed with an integrated mounting support which enables the fast installation and access to the motor / impeller assembly without having to remove or disturb the adjoining ducting. Technical characteristics Model Type Nom. Power abs. Maximum Duty Maximum Sound Weight speed at free current at free operating pressure discharge discharge temperature level (r.p.m.) (W) (A) (m 3 /h) (ºC) (db(a)) (kg) TD-16/1N 25 35,25 16 4 18 1,4 TD-25/1 TD-25/1T 18 89,26 25 4 24 2, Installation BOR-1 TD-16/1N TD-25/1 TD-25/1T GR-1 Accessories included in Kit GSA-1 Flexible aluminium tubing with adhesive duct tape GR-1 Exterior mounted grille BOR-1 Interior circular air valve. 221