Expert Design...Trusted Power

Similar documents
Designed for Today s World

Designed for Today s World

Designed for Today s World

UNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability

power moving forward KVA RANGE Performance I Durability I Serviceability

The kva RAnge

power made simple kva RANGE Performance I Durability I Serviceability

Modular Acoustic Enclosures

Professional Rental Operator

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

Modular Acoustic Enclosures

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Modular Acoustic Enclosures

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Standby Amper VOLTAGE

Modular Acoustic Enclosures

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Sound Attenuated Enclosures Level 1, Level 2 & Level 3. Features ENCLOSURES kva (B Series) Range

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Rental Power. Power Modules up to 1250 kva can be customised to meet rental customer s exact requirements.

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Flexible, Reliable, Connected Power

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

60 Hz FEATURES. Exclusively from your Caterpillar dealer

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

PGDLS / / / / / / / / /

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

THE RANGE. 10kVA kVA ENGINEERING EXCELLENCE BUILT ON EXPERIENCE. Diesel generating sets worldwide

MITSUBISHI STAMFORD P CM control system. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

60 Hz FEATURES. Exclusively from your Caterpillar dealer

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

Cat C1C2 ENCLOSURES SOUND ATTENUATED ENCLOSURES LEVEL 1, LEVEL 2 & LEVEL (B Series) Range FEATURES

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

PGKT / / / / / / / / / / / /

SOUND ATTENUATED ENCLOSURES

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

DIESEL GENERATOR SET. 60 Hz FEATURES

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

WPS350/S EP Series. Features:

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand

WPS250/S EP Series. Features:

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

APD-ULJ250. Standby Power

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

DIESEL GENERATOR SETS

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

28 KW / 28 KVA POWERED by

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Rental Power QSB7 series engine

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

GMR - 67P 67P 09/05/2016 GMR - 067P

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand

700 KVA / 550 KW POWERED by

Transcription:

Expert Design...Trusted Power 350 750 kva Range Performance I Durability I Serviceability

A new power standard has arrived. The 350 750 kva range from FG Wilson is designed by our expert engineers to deliver power you can trust. Over 45 years continued focus on performance, durability and serviceability combined with the most advanced production methods, has led us to the launch of this new industry leading power range. Expert Design Trusted Power

Open Set Range Exciting enhancements have been made to the 350 750 kva open generator set range. Most notable is the innovative fuel tank design combined with a component arrangement that facilitates greater operator access and service, ensuring this range remains the generator set technician s choice. The fuel tank design incorporates a reinforced sloped top plate for liquid run off, acting as a catchment area for all potential liquid spills and leaks. A sloped bottom plate and notched drain plug allows for efficient, controlled drainage of the fuel tank. The fuel tank is designed for 8 hours running at full load in prime applications. A 3 wide fuel fill neck allows easy access and fill, while oil and coolant drain valves provide convenient service accessibility. The baseframe also provides drag points as standard, aiding transportation and reducing the risk of damage during forklift and other handling. The common sense mounting arrangement, for the entire range, provides all customer fuel connection and drainage points on the right hand side as standard. Combined with a revised cooling system on the 550 750 kva product, this range delivers improved performance, serviceability and maintenance access with maximum generator set running time. The common control panel tower mounted on the end of the set, is close coupled with set mounted breakers (up to 1600A) utilising high performance, durable copper braids. The tower has a split box design providing total access to all components and wiring.

The robust and compact base frame extends beyond all mounted generator set components for added protection. It is constructed with high-grade, heavy-duty steel and protected by powder coat paint, ensuring maximum corrosion resistance and durability a truly solid foundation for this high performance range of generator sets.

The enclosed generator set range is designed to offer maximum protection from the elements. Constructed from corrosion resistant galvanised steel and further protected by powder coat paint, FG Wilson enclosures provide class leading robustness and durability. Fuel transfer connection points are easily accessible from outside the enclosure, ensuring your generator set remains protected. Whatever the onsite conditions, the 350 750 kva range can be trusted to perform.

Enclosed Set Range Innovative, functional design enhancements have been made to the 350 750 kva enclosed set range. The robust and aesthetically pleasing enclosure includes many ingenious new features, delivering an enclosed generator set that is designed to perform in the harshest of environments. All roof joints are reinforced with lap joints utilising butyl rubber seals, providing excellent protection against water ingress in extreme conditions. Curved edges ensure a rigid and aesthetically pleasing enclosure structure. The radiator is accessed via a flush mounted rain cap with compression seal a further guard against water ingress. Rotation compression latches ensure a flush door seal with the enclosure frame preventing water ingress; while sloped door seals and purposefully designed grill cut outs ensure optimal water run off. Side hinged doors on each side of the enclosure and removable ducts provide easy access to conduct minor services or major overhauls without the need to remove the enclosure. Control panels and breakers can be easily accessed through the rear door. Robust corner posts provide excellent protection against damage during handling and transportation. Manufactured from a high-grade composite that is UV stable and weather resistant, they also offer optimum corrosion resistance while enhancing the overall design.

Dedicated high ambient enclosure Superior water in

gress protection Trusted performance in extreme conditions

PowerWizard 1.1+, 2.1 A suite of fully digital control panels accompanies this new range. From the PowerWizard 1.1+ standard digital control panel to the easygen-2500 synchronising panel, FG Wilson provides you with more power control as standard. The PowerWizard 1.1+ digital control panel combines straightforward menu navigation with advanced metering and protection technology. This allows easy generator set monitoring and control, whilst ensuring your unit operates within safe parameters. It is suitable for use in mains failure applications, providing advanced metering, protection and diagnostics. PowerWizard 1.1+ Active voltage sender functionality Under / Over voltage protection as standard Shortcut key to view faults Dedicated key to reset all faults and main menu short cut key Spare input / output analogue and digital channels PowerWizard 2.1 Additional monitoring, options and protection AC power metering Data link for long distance annunciator Reverse power protection provided as standard Remote monitoring via MODBUS

easygen-2500 The easygen-2500 offers industry leading power management and control. The easygen-2500 is a generator set-to-set controller for paralleling and load sharing applications of up to 16 generator sets featuring an enhanced load sharing system as standard. The enhanced load sharing system providing advanced generator set load dependent start / stop functionality with automatic generator set selection to ensure optimal system efficiency. easygen-2500 Easy system navigation via programmable soft keys Multiple communication protocols for communication with Engine Control Units (ECUs), external I/O boards, PLCs and modems Capable of working with all common industrial interfaces Full Generator set control and protection Multilingual (11 languages) *PowerWizard 2.1 and easygen-2500 are optional on all models.

Technical data 3-PHASE MODELS 350 750 kva MODELS 50 Hz 60 Hz Model Engine Alternator Prime Standby Prime Standby kva kw kva kw kva kw kva kw P400-1 2206A-E13TAG2 LL6114B 350 280 400 320 - - - - P438-1 2206A-E13TAG5 LL6114B - - - - 400 320 438 350 P450-1 2206A-E13TAG3 LL6114C 400 320 450 360 - - - - P500-1 2506A-E15TAG1 LL6114D 455 364 500 400 - - - - P501-1 2206A-E13TAG6 LL6114B - - - - 438 350 500 400 P550-1 2506A-E15TAG2 LL6114F 500 400 550 440 - - - - P563-1 2506A-E15TAG3 LL6114D - - - - 513 410 563 450 P605-1 2806A-E18TAG1 LL7024F 550 440 605 484 - - - - P625-1 2506A-E15TAG4 LL6114F - - - - 569 455 625 500 P660-1 2806A-E18TAG1A LL7024F 600 480 660 528 - - - - P688-1 2806A-E18TAG1A LL7024F - - - - 625 500 688 550 P700-1 2806A-E18TAG2 LL7024H 635 508 700 560 - - - - P750-1 2806A-E18TAG3 LL7024F - - - - 681 545 750 600 Ratings are based on maximum generator set output - this may vary depending on voltage code selected Please note figures are rounded to the nearest kva / kw DIMENSIONS Open Set Enclosed Set Model Length (mm) Width (mm) Height (mm) Weight (kg) Length (mm) Width (mm) Height (mm) Weight (kg) P400-1 3800 1131 2156 3241 4930 1658 2317 4655 P438-1 3800 1131 2156 3241 4930 1658 2317 4655 P450-1 3800 1131 2156 3253 4930 1658 2317 4667 P500-1 3800 1131 2215 3734 4930 1658 2317 5106 P501-1 3800 1131 2156 3241 4930 1658 2317 4655 P550-1 3800 1131 2215 3858 4930 1658 2317 5230 P563-1 3800 1131 2215 3734 4930 1658 2317 5106 P605-1 3900 1461 2156 4332 5320 1920 2289 5684 P625-1 3800 1131 2215 3858 4930 1658 2317 5230 P660-1 3900 1461 2156 4332 5320 1920 2289 5684 P688-1 3900 1461 2156 4332 5320 1920 2289 5684 P700-1 3900 1461 2156 4372 5320 1920 2289 5724 P750-1 3900 1461 2156 4332 5320 1920 2289 5684

Standard and Optional Features Delivering more as standard STANDARD FEATURES OpTIONAL FEATURES Fully adjustable electronic governor Sound attenuated enclosure Automatic transfer switches (up to 1600A) Engine-mounted battery charging alternator High ambient enclosure Industrial silencer 10 dba reduction Engine-mounted fuel and water separator Anti condensation alternator heater Residential silencer 25 dba reduction Low oil pressure protection Coolant heater Critical silencer 35 dba reduction High water temperature protection Battery charger with auto boost Silencer installation kit Air filters Coastal ingress protection alternator Exhaust elbow kit Alternator IP23 protection Oversize alternator Combined radiator stone guard and transition flange R250 or R450M AVR (model dependant) AR6 Quadrature droop Combined engine heat guards and RFI kit Robust steel constructed baseframe AVR Upgrades Canister type air filters 8hr fuel tank AREP Excitation CE Certification Containment drip tray on all fuel tanks PMG Excitation Lube oil drain pump Baseframe drag and lift points Three phase sensing module Battery isolator switch Base jacking points (enclosed sets only) PowerWizard 2.1 Tool kit Coolant drain valve EasYgen-2500 Fuel level sender and display Lube oil drain valve 4-POLE circuit breaker Fuel level switch, alarm and shutdown BSP fuel sockets Motorised circuit breaker Low coolant temperature alarm PowerWizard 1.1+ control panel Overload via alarm switch on breaker Battery removal 3-POLE circuit breaker and power loom (up to 1600A) Circuit breaker shunt trip Bunded base tank (8 hours) Power terminal strips (2000A) Circuit breaker auxiliary contacts Fuel transfer controls Exhaust bellows and gasket Long distance annunciator (16 channel) Heavy duty battery (950 CCA) Radiator fan and charging alternator guards Voltage and speed adjust Customer lifting point (model dependant) 50% antifreeze (protection to -36 o C) Earth Leakage Lube oil temperature display and shutdown Low coolant level shutdown Volt free contacts for common alarm Neutral Earth Link Battery connection cables, tray and clamp Skid base

Testing and quality Built into every generator set is our unrivalled engineering expertise. Coupled with our innovative production and rigorous testing methods, we ensure that all FG Wilson product reaches the market with outstanding levels of quality and reliability. Continuous flow assembly processes optimise production efficiencies and improve product quality by testing for defects at every stage of the build process. Our Engineering Centre of Excellence includes Europe s largest fully automated hemi-anechoic chamber providing state of the art acoustic research and test capabilities with the ability to replicate various on site conditions. All new product designs are fully validated by our specialist validation engineers. Using our industry leading facilities we test load acceptance, cooling, vibration, noise and water ingress, to required standards and beyond. With such engineering expertise, technical resource and stringent testing going into every generator set, you can always trust FG Wilson. Expert Design Trusted Power