Waste Master OWNER'S MANUAL Rev: 06.15.2015 Page 1 Waste Master Owner's Manual
TABLE OF CONTENTS Introduction 2 Operation 3 Service 4 Removing The Hose Assembly 4 Field Changing Of Waste Master Nozzle 4 Tools Needed 4 Procedure 4 Notes 5 Introduction Unlike traditional hose coils that trap debris, the tough Waste Master hose is designed with its helical coil on the outside, while the inside is much smoother, preventing waste from getting trapped inside the hose. The UV-protected hose features "stay put" technology that keeps it extended during use to the exact length required. The optional storage box can be mounted on the chassis in proximity to the RV holding tank outlet for a permanent cam lock connection. The storage box can also be mounted elsewhere on the RV for convenient storage of the Waste Master hose and nozzle assembly. Fig. 1 Hose stays extended during use Integrated internal rubbersealed shut-off valve ensures total closure User-friendly nozzle features built-in handle for easy control Secure cam lock provides strong, reliable seal and leakproof connection Clear view port shows when hose is clean Tough, puncture-resistant and UV-protected hose Outer skeleton coil structure yields a smooth hose interior that doesn t trap waste 90º discharge port easy to position into any sewage inlet Tapered rubber donut fits securely into any size inlet Rev: 06.15.2015 Page 2 Waste Master Owner's Manual
Operation 1. Unlock and open the Waste Master storage box door. 2. Pull the nozzle from the storage box and slightly open the nozzle to allow air to enter as hose extends. 3. Walk to the sewer inlet and insert the tapered end of the nozzle into the sewer inlet. Close the nozzle. 4. Walk back to the RV and open the black tank gate valve (Fig. 2). Note: Gate valves pictured are for illustrative purposes only. Individual gate valves may differ. 5. Open the nozzle (Fig. 3) by turning the lever (gray handle). "Open" and "Closed" are marked on the nozzle. Let the black tank fully drain and then close the nozzle and the black tank gate valve (Fig. 2). Note: Common industry practice is to empty the black (waste water) tank first, followed by the gray (sink and shower water) tank(s). This order allows the gray water to flush out the sewer hose and helps prevent sewage from remaining in the hose after emptying the tanks. 6. Open the gray tank gate valve (Fig. 2). 7. Open the nozzle (Fig. 3) by turning the lever (gray handle). Let the gray tank fully drain. Close the nozzle, but leave the gray tank gate valve open to allow air to purge as the hose retracts (Fig. 2). 8. Once tanks are empty, hold the nozzle and walk back to the RV. Lay the nozzle on the ground, grasp hose near the storage box and begin to collapse the hose and push it back into the storage box. 9. Close the storage box door and the gray tank gate valve upon completion. Note: The lever on the side of the nozzle MUST be in the closed position during storage and transportation. Fig. 2 Fig. 3 Gray Tank Gate Valve Black Tank Gate Valve Rev: 06.15.2015 Page 3 Waste Master Owner's Manual
Service Removing The Hose Assembly 1. Release the two arms of the female cam lock fitting to disengage the hose (Fig. 4). 2. Remove the entire length of hose from the box. 3. Insert the provided cam lock cap to insure that no waste water drips from the terminal end of the plumbing. Note: The cam lock cap is required during storage and transportation of the unit if the male cam lock fitting on the hose is not locked into the female cam lock fitting at the coach. Fig. 4 Locking Arms Field Changing Of Waste Master Nozzle Tools Needed 1/8" punch Hammer Replacement Waste Master nozzle (2) dowel pins End seal Dow Corning 111 lubricant Procedure 1. At the nozzle, drive the two pins out with a 1/8" punch and hammer (Fig. 6). Note: Orient nozzle as seen in (Fig. 6). Drive pins out toward operating lever (Fig. 6). 2. Remove nozzle from hose. 3. Before installing new nozzle, make sure new end seal (Fig. 5) is in place (flat end in groove). 4. Coat the seal with Dow Corning 111 lubricant included in kit. 5. Install new nozzle on hose. 6. Drive pins back into place. Install from operating lever side, smooth end first. Fig. 5 - Kit Number 349521 Fig. 6 Lubricant End Seal Replacement Nozzle Dowel Pin Rev: 06.15.2015 Page 4 Waste Master Owner's Manual
Notes Rev: 06.15.2015 Page 5 Waste Master Owner's Manual
The contents of this manual are proprietary and copyright protected by Lippert Components, Inc. ( LCI ). LCI prohibits the copying or dissemination of portions of this manual unless prior written consent from an authorized LCI representative has been provided. Any unauthorized use shall void any applicable warranty. The information contained in this manual is subject to change without notice and at the sole discretion of LCI. Revised editions are available for free download from www.lci1.com. Please recycle all obsolete materials. For all concerns or questions, please contact Lippert Components, Inc. Ph: (574) 537-8900 Web: www.lci1.com Email: customerservice@lci1.com Rev: 06.15.2015 Page 6 Waste Master Owner's Manual