POWER-HUB 12 VOLT PORTABLE POWER STATION

Similar documents
BATTERY METER SMART BATTERY GUAGE

12 Volt 1500 Amp Intelli-Start LITHIUM JUMPSTARTER

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

12V 160A/24V 185A MANUAL WORKSHOP BATTERY CHARGER

12/24V 30A AUTOMATIC/MANUAL WORKSHOP BATTERY CHARGER

12 VOLT BATTERY & ELECTRICAL SYSTEM ANALYSER

POLYCRYSTALLINE SOLAR PANELS. (MC4 Series) P/No SPP80-MC4, SPP120-MC4, SPP135-MC4, SPP150-MC4

HEAVY DUTY DUAL BATTERY TRAY

12 VOLT SOLAR PANEL KITS MONOCRYSTALLINE. P/No. SPP160K

INTELLI-POWER BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE. P/No.s IC700, IC700W, IC1000, IC1500

INTELLI-CHARGE BATTERY CHARGER 12 VOLT, 7 STAGE SWITCHMODE

PRO-WAVE INVERTER 12 VOLT, 150W PURE SINE WAVE

INTELLI-CHARGE BATTERY CHARGER 7 STAGE SWITCHMODE

PRO-WAVE INVERTER 12 VOLT, PURE SINE WAVE. P/No.s PW150, PW350, PW600, PW900 & PW1800

DC/SOLAR BATTERY CHARGER

4. TECHNICAL SPECIFICATIONS

230VAC Power Inverter 400W Owner s Manual

Instruction Manual. Instruction Manual LIFETIME PLU Manufactured and packaged for SRGS PTY LTD ABN CONDITIONAL

Matson Jump Starter Operator s Manual

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

JUMP STARTER OPERATOR S MANUAL RA1900

WARNINGS, CAUTIONS AND NOTES

Part Number: DBDC10 / DBDC20 DC to DC Dual Battery Charger Manual

Part Number: DCDC10S / DCDC20S DC to DC Dual Battery Charger Manual

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER BATTERY BOX

OWNERS MANUAL POWER PACK 44AH. Part No. COMPBI012. Australia s original Outdoor brand

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

Compact Sine Inverter

CX-SERIES ADVANCED BATTERY CHARGER

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

Installation and Operating Instructions. Solar System Controller ISC3030

Installation and Operating Instructions. Solar System Controller ISC3020

MULTI FUNCTION POWER PAK PLUS

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

Model: CC1206 OWNER S MANUAL AUSTRALIAN & NEW ZEALAND STANDARD AS/NZS APPROVED

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

SAVE THESE INSTRUCTIONS

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

Go Power! Manual. GP-Smart Charger

Power Inverter 400 MW Owner s Manual

Operating Manual MP-3739

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER DC TO DC BATTERY CHARGER.

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

BS20 BATTERY CHARGER For lead-acid batteries

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

S150,S300 Series Pure Sine Wave Inverter User s Manual

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

M LCD display,7-stage switch mode charging current

Cruising Charger Series OWNER S MANUAL

Power Meter INSTRUCTION MANUAL. Model Number: AESPP AUS

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

BATTERY CHARGER Plus Battery maintainer & Rejuvenator

POWER PAK II / PLUS II

HPP1 MK6-15A/20A R00 Owners Manual

AL-KO ESC USER MANUAL

HYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

SCC-MPPT Solar Charge Controller

BOOSTER CABLES 1000 AMP Intelli-Check II

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

EC200 ELECTRONIC CONTROL SYSTEM

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

PureWatts Elite Power Inverter. Instruction Manual 1000 / 2000 WATTS

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

Power Products Catalog

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

HPP1 MK5 Owner s Manual

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

GENIUS-II Series Owner's Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Intelligent Charging System Series

Installation and Operation Back-UPS BX550CI-CN

C3 Operating Instructions

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Compact Solar Charger. Model Number ACSC-116 INSTRUCTION MANUAL

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

General Precautions. Personnel Precautions

Item no Smart AC 200 USB. User s Manual

Compact Solar Charger. Model Number ACSC-114 INSTRUCTION MANUAL

Lithium Power Supply

SPECTRE DRONE USER MANUAL

GBC Polar A4 & A3 Laminators. Instruction Manual

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

24V HEAVY DUTY JUMP STARTER/ POWER BANK MB3752. Storage. Specifications

SCC-MPPT Solar Charge Controller

Solar Charge Controller

4WD ACCESSORIES 600W POWER INVERTER. INSTRUCTION MANUAL (For use in a dry protected environment )

400W Solar Charger Maximum Power Point Tracker

SCC-MPPT Solar Charge Controller

Abso Sinewave. Inverter-Charger 2000W (IC ) 3000W (IC ) 4000W (IC244090i) Owner s Manual

Smart Charger SBC User s Manual

Transcription:

POWER-HUB 12 VOLT PORTABLE POWER STATION P/No. PH125

WARNINGS Risk of explosive gas. Working in the vicinity of a lead-acid battery can be dangerous Batteries might release explosive gases during normal operation and charging Before using the product, read and follow the instructions carefully. Follow all manufacturer s instructions Do not smoke, use matches, use a cigarette lighter, or allow a spark or flame near the battery Do not allow metal to bridge the battery posts. It may spark or short-circuit the battery and cause an explosion Remove rings, bracelets, necklaces and watches when working with a lead-acid battery Before accessing the battery leads (Red for positive and back for negative), disconnect all devices or power sources from the sockets and DC terminals of the Power-Hub Ensure correct polarity when connecting to the battery leads Do not submerge the product in water or expose to rain Not recommended to use the product for critical power backup application Designed to work with 12V lead acid batteries (including Calcium, Gel and AGM) only Not recommended to house, wet or normal car battery Do not insert objects into the sockets ACKNOWLEDGEMENT Thanks to Century Yuasa Batteries Pty Ltd and Mr Jason Hill who provided valuable help and support in development of this product. 2

Overview The Projecta Power-Hub (PH125) is a batty box which is designed to house high capacity batteries, equipped with advanced battery fuel gauge. The Power-Hub provides all the necessary connections to power portable fridges and electronic devices. It has the following features. Suitable for popular deep cycle AGM lead acid battery 300W Pure Sinewave Inverter (no early shutdown issue) Provides 10 popular power outlets which include: 2 x 10A Accessory Sockets 2 x 15A Merit Sockets 2 x 2A USB Sockets 1 x 10A Engel Type Socket 1 x 50A Heavy Duty Socket 1 x DC Terminal for high current requirements 1 x 240V AC Outlet All outputs via Accessory, Engel Type, Merit and 50A Heavy Duty are protected by a resettable fuse 2.4 full colour LCD display Configurable Low battery capacity and battery health alarm Using patented technology to monitor battery characteristics like battery state of charge and state of health Glass reinforced plastic casing 3

QUICK START 1. Unscrew the top section of the unit with the Allen Key provided 2. Place the top section next to the main body of the unit 3. Place the battery into the main housing 4

4. Secure the battery with horizontal and vertical straps provided 5. Use the pre-cut packaging foam to secure the battery 6. Connect the black battery lead to the negative terminal of the battery 5

7. Connect the red battery lead to the positive terminal of the battery 8. Put the top section back onto the main body 9. Secure the top section with the screws provided 6

10. Press enter to acknowledge the Welcome message on the LCD screen 11. Enter the battery capacity in Ah 12. Enter value for the low battery alarm and Ah 7

13. Enter the value for battery health warning alarm in Ah 14. Fully charge the battery with any multistage battery charger (e.g. IC1000, PC1600 etc) 15. Disconnect the battery charger when the battery is full 16. Unit is ready to use 8

SPECIFICATIONS Part No. PH125 Inverter Input Voltage Range 10.5V 15.0 Vdc Input Current 32A Open Circuit Output Voltage 240±5% Vac Full Load O/P Voltage 240±5% Vac Output Frequency 50±0.5Hz Continuous Output Power 300VA Surge Output Power 600VA for 0.2s Output Waveform Pure Sinewave Protection Overload with Auto-recovery 360 450VA Input Overvoltage 15.5±0.5Vdc LVD 10.5±0.2VDC Reconnect Input Voltage after LVD 12±0.2VDC Overtemperature Auto-recovery Reverse Polarity By Fuse Battery Fuel Gauge Input Voltage Range 6.0 17.0 Vdc Display Resolution Current 0.1 A Voltage 0.1V Battery Capacity 0.1Ah Type of Battery Supported Lead Acid Power Outlets 2 x 10A Accessory Socket Resettable Fuse Protected 2 x 15A Merit Socket Resettable Fuse Protected 1 x 10A Engel Type Socket Resettable Fuse Protected 1 x 50A Heavy Duty Battery Connector Resettable Fuse Protected 1 x DC Terminal 2 x 2A USB Ports Short-circuit protected 1 x 300VA AC Socket Overload and Short-circuit Protected Physical Characteristics Weight 5.5 kg External Dimension 390mm (L) x 235mm (W) x 337mm(H) Maximum Battery Dimension Allowed 230mm x 177mm x 338mm* Operating Temperature 0 to 50 o C Compliance EMC Certified to meet AS/NZS 61000.6.3 Safety Tested to meet AS/NZS 4763 *See drawing over the page 9

Maximum Battery Dimension Allowed: Deep Cycle: 60 140Ah Automotive: 300 800CCA Marine: 350 950 MCA BATTERY GAUGE USER INTERFACE MAIN MENU MENU Battery Settings Alarm Settings Display On Time Settings Brightness Exit Function Battery Settings Alarm Settings Display On Time Settings Brightness Restart Learning Cycle Exit Description Set Battery Capacity Set Low Battery Capacity and Battery Health Alarms Set the LCD Display On Time (10 mins as default on time) Set the brightness of the LCD Display (50% as default value) Force Battery Gauge to restart Battery Profile Learning Cycle Exit Menu Screen and return to Default Screen 10

DEFAULT SCREEN Battery Voltage 5:30pm 12.5 V Time Remaining To Full 100% 70% Battery Charging + 6.5 A 120.0 5.0 hrs Battery State Battery Current Lightning sign indicates the battery is charging Battery State of Charge (SOC) in % Battery Symbol Colour: Green: 50% < SOC <100% Orange: 20% < SOC 50% Red: SOC < 20% Time to Full when the battery is charging or time to empty when the battery is discharging or displays System Idle ADVANCED SCREEN Battery Voltage Battery Health has 4 levels: Ideal, Good, Fair and Poor Battery Capacity 5:30pm 12.5 V Battery Health Battery Power Remaining Capacity Time Remaining To Full + 6.5 A GOOD 100.0Ah 120.5 5.5 hrs Time to Full when the battery is charging or time to empty when the battery is discharging or displays System Idle Battery Charging 100% 70% Battery State Battery Current + for Charging and for Discharging Battery State of Charge (in %) Lightning sign as charging Indication Battery Symbol Colour: Green: 50% < SOC <100% Orange: 20% < SOC 50% Red: SOC < 20% 11

BATTERY SETTINGS BATTERY CAPACITY AT 100 Ah Use Up and Down buttons to change the value of battery capacity which is marked on the battery case. Press OK button to apply the changes. The default value is 100Ah. ALARM SETTINGS LOW BATTERY CAPACITY BATTERY STATE OF HEALTH at 10 % Use Up and Down buttons to change the value of low battery capacity alarm. Reduce the value to 0 to disable the alarm. Press OK button to apply the changes. The default value is 10Ah. 12

BATTERY STATE OF HEALTH BATTERY STATE OF HEALTH at 10 % Use Up and Down buttons to change the value of battery state of health alarm. Reduce the value to 0 to disable the alarm. Press OK button to apply the changes. The default value is 30%. When the battery state of health diminishes to the set level, an audio alarm is activated. The audio alarm can be muted by pressing any button. DISPLAY ON TIME SETTING Use Up and Down buttons to change the time the LCD display remains on without user action. Press the OK button to apply change. The default value is 10 mins. After the display screen is turned off, it can be re-activated by pressing the menu button. DISPLAY ON SETTINGS 48 Mins 13

BRIGHTNESS Use Up and Down buttons to change the brightness of LCD display. Press OK button to apply the changes. The default value is 50%. BRIGHTNESS 50 % BATTERY HEALTH It is an indicator to show if the battery requires rejuvenation or replacement. Indication Ideal or Good Fair Poor Description No action is needed Try to rejuvenate the battery Try to rejuvenate the battery as soon as possible. If the battery health indicator is still Poor after rejuvenation, the battery is close to its end of life, replace the battery as soon as possible RESTART LEARNING CYCLE Through restarting the learning cycle, the battery fuel gauge re-learns the battery characteristics and selects the best profile to predict the battery characteristics like battery state of charge and state of health. Here are the steps for restart learning cycle: Step 1: Press the menu button, use the down button to select Restart Learning Cycle and press OK to confirm selection. Step 2: Connect a multi-stage battery charger with reverse polarity protection to any sockets or terminals, except AC socket. Step 3: Fully charge the internal battery and the Learning Cycle is completed. 14

FREQUENTLY ASKED QUESTIONS Q. What is state of charge (SOC)? A. It is the remaining battery capacity expressed as a percentage of full charge capacity. Q. What is State of Health (SOH) or Battery Health? A. It is expressed as a percentage of the ratio of predicted full charge capacity over the design capacity. The PH125 uses 4 levels to represent the battery health: Ideal, Good, Fair and Poor. Please look at the battery health section for more detail. Q. What is the low battery capacity alarm for? A. The unit uses an audible alarm to remind the user that the battery capacity is reduced to a set level. This allows the user to recharge before the battery is fully discharged. Q. What is the battery health alarm for? A. The unit also uses and audible alarm to remind the user that the battery s health has reduced below the set level. This allows the user to recondition the battery before it is too late or change the battery if required. 15

WARRANTY STATEMENT Brown & Watson International Pty. Ltd. ( BWI ) of 1500 Ferntree Gully Road, Knoxfield, Vic., telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products described in its current catalogue will under normal use and service be free of failures in material and workmanship for a period of one (1) year from the date of the original purchase by the customer as marked on the invoice (see elsewhere for specific warranty period). This warranty does not cover ordinary wear and tear, abuse, alteration of products or damage caused by the purchaser. To make a warranty claim the consumer must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a warranty assessment may be performed. The consumer must also deliver the original invoice evidencing the date and place of purchase together with an explanation in writing as to the nature of the claim. In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or replace it at its discretion. In the event that a major failure is determined the consumer will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable loss or damage. This warranty is in addition to any other rights or remedies that the consumer may have under State or Federal legislation. IMPORTANT NOTE Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Distributed by AUSTRALIA Brown & Watson International Pty Ltd Knoxfield, Victoria 3180 Telephone (03) 9730 6000 Facsimile (03) 9730 6050 National Toll Free 1800 113 443 NEW ZEALAND Narva New Zealand Ltd 22 24 Olive Road PO Box 12556 Penrose Auckland, New Zealand Telephone (09) 525 4575 Facsimile (09) 579 1192 IS357 Issue 1 11.11.16