SLA Battery Capacity Analyzer

Similar documents
Model 1693, 1694 Switching DC Power Supply

Model 1672, 1673 Triple Output Power Supply

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Model 1900, 1901, 1902 Switching DC Power Supply

DC REGULATED POWER SUPPLY

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Model 1900, 1901, 1902 Switching DC Power Supply

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Instruction Manual. Model 310 Digital Milli-Ohm Meter

DC REGULATED POWER SUPPLY

Model P772 Conductivity Meter. User Manual

Switching DC Power Supply

362 Clamp Meter. Users Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Triple Output High Resolution Power Supply. User Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

OPERATING INSTRUCTIONS

Megohmmeter Test Probe

i3000s/i2000 Flex AC Current Probe

Go to to register your product and find more information.

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Triple Output Power Supply

OBAE, OBAEXU, ON BOARD Battery Chargers

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

OBE, OBEXU, ON BOARD Battery Chargers

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

5.2 PRE-OPERATION PROCEDURE WARRANTY

373 Clamp Meter. Users Manual

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

OPERATING INSTRUCTION

QSSE, QSSEX INDUSTRIAL Battery Chargers

OWNERS MANUAL JANUARY 2007 ISO

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

User Guide IGD Series

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

QPET, QPETXU Battery Chargers

60 Watt Industrial LED Low Bay Light

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

365 Detachable Jaw True-rms Clamp Meter

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

TS Series. MultiStage Centrifugal Pump Instruction Manual. Walrus America Inc. ISO 9001 Certified

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

ADI-125/750 ADI-125/1500 ADI-125/2500

KMP Insulation-Continuity Tester. Users Manual

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

c-go 24V/6A 24V/8A 24V/12A

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

362 Clamp Meter. Users Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Safety design conforming to the following provisions

Safety design conforming to the following provisions

Users Manual. Phase Rotation Indicator

Water Level Meter + Temperature

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

PY-11 Voltage & Continuity Tester

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Model G14SD Vapor Management System

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

Extended Battery Cabinet for Nfinity

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

OPERATING INSTRUCTIONS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

TPHK Series Immersible Pump

Fiber Optic Illuminator. Model 21AC Model 21DC

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

1000FLT. Users Manual. Fluorescent Light Tester

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

30 Amp Solar Charge Controller

For technical questions and replacement parts, please call

323/324/325 Clamp Meter

Installation and Operation Manual

MIL-24/2600Q MIL-24/3200DQ

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Digital/Analog Megohmmeter Model 1026 USER MANUAL

PSX-240 Enclosed Autotransformer Installation Manual

DC to AC Power Inverters

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

DC to AC Power Inverters

TPAK Series COOLANT PUMP

302+/303 Clamp Meter. Users Manual

20A Solar Charge Controller

Power Inverter 400 MW Owner s Manual

INSTRUCTION MANUAL DM5B Fax: (503)

WJS-3500 User Guide MIGHTY JUMP STARTER. Portable Jump Start & Power Supply

WJS-1800 User Guide MINI JUMP STARTER. Portable Jump Start & Power Supply

USER MANUAL English / Español

800 WATT POWER INVERTER

Toll Free DX100. Owner's Guide. Printed in China

Transcription:

Model: 600B SLA Battery Capacity Analyzer USER MANUAL

Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service, and repair of this instrument. Before applying power to this instrument: Read and understand the safety and operational information in this manual. Apply all the listed safety precautions. Verify that the voltage selector at the line power cord input is set to the correct line voltage. Operating the instrument at an incorrect line voltage will void the warranty. Make all connections to the instrument before applying power. Do not operate the instrument in ways not specified by this manual or by B&K Precision. Failure to comply with these precautions or with warnings elsewhere in this manual violates the safety standards of design, manufacture, and intended use of the instrument. B&K Precision assumes no liability for a customer s failure to comply with these requirements. Category rating The IEC 61010 standard defines safety category ratings that specify the amount of electrical energy available and the voltage impulses that may occur on electrical conductors associated with these category ratings. The category rating is a Roman numeral of I, II, III, or IV. This rating is also accompanied 2

by a maximum voltage of the circuit to be tested, which defines the voltage impulses expected and required insulation clearances. These categories are: Category I (CAT I): Measurement instruments whose measurement inputs are not intended to be connected to the mains supply. The voltages in the environment are typically derived from a limitedenergy transformer or a battery. Category II (CAT II): Measurement instruments whose measurement inputs are meant to be connected to the mains supply at a standard wall outlet or similar sources. Example measurement environments are portable tools and household appliances. Category III (CAT III): Measurement instruments whose measurement inputs are meant to be connected to the mains installation of a building. Examples are measurements inside a building's circuit breaker panel or the wiring of permanently-installed motors. Category IV (CAT IV): Measurement instruments whose measurement inputs are meant to be connected to the primary power entering a building or other outdoor wiring. Do not use this instrument in an electrical environment with a higher category rating than what is specified in this manual for this instrument. 3

You must ensure that each accessory you use with this instrument has a category rating equal to or higher than the instrument's category rating to maintain the instrument's category rating. Failure to do so will lower the category rating of the measuring system. Do not operate in an explosive or flammable atmosphere Do not operate the instrument in the presence of flammable gases or vapors, fumes, or finely-divided particulates. The instrument is designed to be used in office-type indoor environments. Do not operate the instrument In the presence of noxious, corrosive, or flammable fumes, gases, vapors, chemicals, or finelydivided particulates. In relative humidity conditions outside the instrument's specifications. In environments where there is a danger of any liquid being spilled on the instrument or where any liquid can condense on the instrument. In air temperatures exceeding the specified operating temperatures. 4

In atmospheric pressures outside the specified altitude limits or where the surrounding gas is not air. In environments with restricted cooling air flow, even if the air temperatures are within specifications. In direct sunlight. This instrument is intended to be used in an indoor pollution degree 2 environment. The operating temperature range is 0 C to 40 C and the operating humidity range is 95% relative humidity with no condensation allowed. Measurements made by this instrument may be outside specifications if the instrument is used in nonoffice-type environments. Such environments may include rapid temperature or humidity changes, sunlight, vibration and/or mechanical shocks, acoustic noise, electrical noise, strong electric fields, or strong magnetic fields. Do not operate instrument if damaged If the instrument is damaged, appears to be damaged, or if any liquid, chemical, or other material gets on or inside the instrument, remove the instrument's power cord, remove the instrument from service, label it as not to be operated, and return the instrument to B&K Precision for repair. Notify B&K Precision of the nature of any contamination of the instrument. Clean the instrument only as instructed 5

Do not clean the instrument, its switches, or its terminals with contact cleaners, abrasives, lubricants, solvents, acids/bases, or other such chemicals. Clean the instrument only with a clean dry lint-free cloth or as instructed in this manual. Not for critical applications This instrument is not authorized for use in contact with the human body or for use as a component in a life-support device or system. Do not touch live circuits Instrument covers must not be removed by operating personnel. Component replacement and internal adjustments must be made by qualified service-trained maintenance personnel who are aware of the hazards involved when the instrument's covers and shields are removed. Under certain conditions, even with the power cord removed, dangerous voltages may exist when the covers are removed. To avoid injuries, always disconnect the power cord from the instrument, disconnect all other connections (for example, test leads, computer interface cables, etc.), discharge all circuits, and verify there are no hazardous voltages present on any conductors by measurements with a properly-operating voltagesensing device before touching any internal parts. Verify the voltage-sensing device is working properly before and after making the measurements by testing with known-operating voltage sources and test for both DC and AC voltages. Do not attempt any service or adjustment unless another person capable of rendering first aid and resuscitation is present. 6

Do not insert any object into an instrument's ventilation openings or other openings. Servicing Do not substitute parts that are not approved by B&K Precision or modify this instrument. Return the instrument to B&K Precision for service and repair to ensure that safety and performance features are maintained. For continued safe use of the instrument Do not place heavy objects on the instrument. Do not obstruct cooling air flow to the instrument. Do not place a hot soldering iron on the instrument. 7

Table of Contents Section 1 General Description... 9 1.1 INTRODUCTION... 9 1.2 APPLICATIONS... 9 1.3 SPECIFICATIONS... 9 Section 2 Operation... 10 2.2 OPERATING PROCEDURE... 11 Service Information... 13 Limited One-Year Warranty... 14

Section 1 General Description 1.1 INTRODUCTION B&K Precision Battery Capacity Analyzer Model 600B measures the % capacity left in a battery. The model 600B supports 12V storage type lead acid batteries with wide range of Ah capacity. No external power (Main or DC) is required. The unit works on BUT (Battery Under Test). 1.2 APPLICATIONS As the information age develops it is likely that the demand for UPS units will increase for use in hospitals, offices, labs etc. It is expected that the importance of battery maintenance will increase along with increasing demand for UPS. The 600B can be applicable for Automobile Service Stations, UPS Manufacturing, Maintenance and Field Servicing, QC Department, Battery Systems in Railways, Telecommunications, Ships / Submarine. 1.3 SPECIFICATIONS TECHNICAL 1) Capacity Display Range: 0 % to 100 % 2) Max. Input Voltage: 20 V 3) No Load Voltage Indication Accuracy: ± 2 counts Caution: Do not exceed max. input voltage rating. Doing so may cause fatal damage to the unit. PHYSICAL 1) Dimensions (WxHxD): 2.91 x 10.44 x 2.12 (74 x 265.1 x 54 mm) 2) Weight: 2.65 lbs. (1.2 Kg.) NOTE: Specifications and information are subject to change without notice. Please visit www.bkprecision.com for the most current product information. 9

Section 2 Operation FRONT PANEL CONTROLS Refer to the Front view of the unit. 1) Ah Range : With this key the user can select the correct Ah range according to the battery under test. 2) Ah Select LED: This LED in ON to indicate that the user can select the Ah range. 3) Ah Setting Saved LED: This LED is ON when the unit locks to a particular Ah range set by the user. 4) Display Mode: This key selects the display either as No load voltage or % balance capacity. 5) Battery Voltage: Indicates that the Battery voltage is being displayed. 6) Battery Capacity %: This LED is ON when remaining capacity is being displayed. 7) Load Test: The test starts by pressing this key. 8) Ready/Complete: When this LED is ON and steady, indicates that the unit is ready to conduct a test. 9) Test In Progress: This LED is ON for approx. 3 sec. when the battery test is carried out. 10) Reverse Polarity: If the unit is connected to a battery in reverse polarity this LED will be ON. 11) LED Display Displays either battery voltage or battery capacity percent. 12) +ve Cable Positive connecting cable with strain relief. 13) ve Cable Negative connecting cable with strain relief. 10

2.2 OPERATING PROCEDURE Follow the steps as outlined below: 2.2.1 Connection Procedure Connect Battery Capacity Analyzer (600B) to Battery Under Test (BUT). Connect the +ve terminal of 600B to +ve terminal of Battery. Connect -ve terminal of 600B to -ve terminal of Battery. The 600B will be powered by the BUT. On Power up, 600B performs a self test by turning on the 7 segments, LEDs one after another & finally flashing the version number. 2.2.2 Selecting Ah Capacity Press the 'Ah Range' key. The select LED glows as shown. The display will show the last selected/stored Ah value. (Power ON default value is 7 Ah) To change the value, press the key again. Display shows new value. Keep on pressing till the desired Ah is obtained. Caution: Do not connect the +ve terminal of 600B to -ve terminal of BUT and -ve terminal of 600B to +ve terminal of BUT. By doing so, the Reverse Polarity LED glows as shown. To Lock the Ah capacity, either press any key OTHER than the Ah Range key OR wait for about 10 seconds. Your selected Ah value will automatically get locked and is indicated by the glowing of 'Locked' LED. 11

2.2.4 Observing Result After a Test By default the Battery Voltage is displayed on the display. To observe the Balance Capacity left, press the Display Mode switch. 2.2.3 Conducting a Test Test can be conducted any time Ready/Complete LED is ON by pressing the Load Test key. By doing so the Test On LED starts glowing. Typically, it glows for about 2 seconds. Thereafter the Ready test starts blinking. (The blinking time depends on the Ah range selected). Thereafter it becomes steady. The display will show the capacity in percentage. Note: Balance Capacity can have a meaningful value only after conduction of a test. At power on, a value of 0 is shown. Hence Balance Capacity should be seen only after conduction of a test. To observe No Load Battery Voltage, press the Display Mode Key. The display will show the No Load Battery Voltage. Note: User cannot conduct a test while the Ready LED is blinking. 12 1) Do not connect Model 600B to a voltage source more than 20V. 2) Do not connect the unit to a battery connected in circuit.

Service Information Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging with proof of purchase to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Non-Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Customers not on an open account must include payment in the form of a money order or credit card. For the most current repair charges please refer to the service and support section on our website. Return all merchandise to B&K Precision Corp. with prepaid shipping. The flat-rate repair charge for Non-Warranty Service does not include return shipping. Return shipping to locations in North America is included for Warranty Service. For overnight shipments and non-north American shipping fees please contact B&K Precision Corp. B&K Precision Corp. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 714-921-9095 Include with the returned instrument your complete return shipping address, contact name, phone number and description of problem. 13

Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its products and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from date of purchase. B&K Precision Corp. will, without charge, repair or replace, at its option, defective product or component parts. Returned product must be accompanied by proof of the purchase date in the form of a sales receipt. To help us better serve you, please complete the warranty registration for your new instrument via our website www.bkprecision.com Exclusions: This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs. The warranty is void if the serial number is altered, defaced or removed. B&K Precision Corp. shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitations of incidental or consequential damages. So the above limitation or exclusion may not apply to you. This warranty gives you specific rights and you may have other rights, which vary from state-to-state. B&K Precision Corp. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 714-921-9095 14

CE Declaration of Conformity This instrument meets the requirements of 2006/95/EC Low Voltage Directive and 2004/108/EC Electromagnetic Compatibility Directive with the following standards. Low Voltage Directive - EN61010-1 : 2001 EMC Directive - EN61326-1 : 2013 - CISPR11 - EN61000-4-2 : 2009 - EN61000-4-3 : 2006 + A2 : 2010 - EN61000-4-8 : 2010 15

B&K Precision Corporation 22820 Savi Ranch Parkway Yorba Linda, California 92887 www.bkprecision.com 2015 B&K Precision Corporation Printed in Taiwan 030916 16