OpenEVSE - 40A Charging Station

Similar documents
OpenEVSE. Testing Basic and Advanced

WaltZilla TM Installation and Operation Guide

E Series CE Approved Intermittent Pilot Ignition Control

OpenEV. OpenEVSE 40A Charging Station. Build a Charging station for a 50A circuit (40A Charge current) with an OpenEVSE kit.

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

Application Engineering

INSTALLATION GUIDE AND USER MANUAL

TRAVEL CORDSET AND WALL STATION TEST REPORT

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Language specific user manuals are available on

USER GUIDE TURBOCORD TM PORTABLE CHARGER 240V. AeroVironment EV Solutions

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

Model No. PS-2000 WARRANTY AND OPERATING INSTRUCTIONS

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Quick Start Guide TS 910

Virtual Measurements & Control. VC210 Operators Manual

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

Electric Vehicle Charging Station

Application Engineering

Quick Start Guide TS 910 & TS 920

ADVANCED PID TROUBLESHOOTING

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

INSTALLATION GUIDE AND USER MANUAL

User s Manual. Automatic Switch-Mode Battery Charger

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

USER GUIDE. 100% electric. AeroVironment EV Solutions Charging Dock Model EVSE-RS Plug-In

User Guide for Viridian EV Charging Stations

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

OTEC Transfer switch open transition

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

USER GUIDE. AeroVironment EV Solutions Charging Station Model EVSE-RS Plug-in

OPERATOR TROUBLESHOOTING GUIDE

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

LS/ CCS. Constant Current Charger

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

Transfer switch GTEC open or delayed transition

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

DIESEL Engine Fire Pump Controllers Features

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

OPERATOR CALIBRATION GUIDE

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

DSEULTRA DSE6000 Quick Start Guide Document Number

REVISION HISTORY REVISION HISTORY

Installation and Operating Instructions. Solar System Controller ISC3030

EAGLETRON II REMOTE CONTROL OPERATOR and MAINTENANCE. Remote Control Procedure

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Language specific user manuals are available on

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

G72x Series Direct Spark Ignition Controls

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Installation Instructions & Users Manual

STONESTAR AUSTRALIA PTY LTD

A419ABG-3C Electronic Temperature Control

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Operations Manual Pika Harbor Smart Battery

Gate & Door Controller with LCD and Intelligent Technology

ORDERING INFORMATION SPECIFICATIONS APPLICATION

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Model (Circuit Tester) Model (GFCI Tester)

MIL-24/2600Q MIL-24/3200DQ

Subject Underhood G System Error Codes and Symptoms System or Parts affected

User Manual. Solar Charge Controller 3KW

MODEL 422 Submersible Pump Controller

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

Model LA 4400 Time Delay OFF Controller

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

MITYFLEX PERISTALTIC PUMPS

Definitions. Scope. Customer Generation Interconnection Requirements

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Installation and Operating Instructions

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

MP7650 CONTROLLER. Lake-Shore-Electric.com MP7650 Controller STANDARD FEATURES 1.0 INTRODUCTION

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

SECTION 2 - PROCEDURES. Features. 2.6 MOTOR CONTROLLER. Modes of Operation JLG Lift 2-5

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

ICS-200A Service Manual

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

User Manual Solar Charge Controller 3KW

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

c-go 24V/6A 24V/8A 24V/12A

AL600ULX Series. Power Supply/Charger Installation Guide

M40/50RF System - Installers Guide

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Installation and Operating Instructions. Solar System Controller ISC3020

Transcription:

OpenEVSE - 40A Charging Station P50 Advanced P50 Standard http://www.openevse.com

Read and save these instructions prior to installing and operating your Charging Station. Retain this installation guide for maintenance and troubleshooting information. If you have further questions, contact Customer Service at support@openevse.com. WARNING: To reduce the risk of fire, electric shock, and serious bodily injury, observe the following: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. When cutting or drilling into structure, do not damage electrical wiring and other hidden utilities. Use this device only in the manner intended. CAUTION: The installation of this charging Station must be in accordance with all national and local electrical codes. CAUTION: Exercise caution and common sense when powering the device. Do not connect to a damaged power source. WARNING: Power must be disconnected before installation and servicing, cleaning, and other user-maintenance. Failure to disconnect power creates risk of fire, electric shock, and serious bodily injury. CAUTION: The product warranty will not cover equipment damage or failure that is caused by improper installation or operation. WARNING: Do not install in an environment that is excessively dusty, conductive, corrosive, or gas-filled, is exposed to open flames (e.g., gas-burning stoves), is near strong chemicals or solvents, or where there is excessive heat, shock, or vibration. CAUTION: This charging station is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the charging station by a person responsible for their safety. Children should be supervised to ensure that they do not play with the charging station. 1 Users Guide

Contents Introduction... 4 About... 4 License... 5 Technical Specifications... 6 Safety... 9 Power interlock... 9 Pilot Signal... 9 Self Check... 9 Ground Monitoring... 9 Ground Fault Interrupt... 9 Stuck Relay detection... 10 Electric Vehicle Identification... 10 Ventilation Required... 10 Internal Temperature... 10 Temperature Throttling... 10 Installation... 11 Operation... 15 Display... 15 LCD Text... 15 Real Time Clock... 16 Button Menu... 17 Button Menu Options... 17 Power on Self Test... 18 Self Check... 18 Errors... 18 Additional Resources... 19 Users Guide 2

3 Users Guide

Introduction About OpenEVSE started in February 2011 with a simple experiment to try to generate the SAE J1772 pilot signal on an Arduino Board. One experiment lead to another to another until a prototype J1772 compatible controller was born. With lots of feedback and interest from the great folks on the "My Nissan LEAF" Forum a few boards were offered to other hardware hackers (6 were built in the first batch) 6 turned into more and more... Boards and now complete kits have been built all over the world and are reliably charging many EVs all over the globe. OpenEVSE was released as an Open Source hardware and software project in October 2011. For more information: OpenEVSE Information info@openevse.com OpenEVSE Support support@openevse.com Users Guide 4

License This manual was written by Christopher Howell and is released under the Creative Commons 3.0 with Attribution, share alike license. OpenEVSE is a truly open project with all source materials freely shared. The licenses are clearly defined and there are zero additional restrictions. OpenEVSE may be used for Commercial purposes as defined in the licenses OpenEVSE Code license GNU General Public License v3 http://www.gnu.org OpenEVSE Content license (including this document) Creative Commons 3.0 with Attribution Share alike (CC 3.0 BY-SA) http://creativecommons.org/licenses/by-sa/3.0/ The OpenEVSE Project and Source code has been evaluated by the Open Source Hardware Foundation and meets the requirements for Open Hardware. The registration number for OpenEVSE is US000028. 5 Users Guide

Technical Specifications The OpenEVSE P50A Advanced is compatible with Level 1 and Level 2 can be powered by a single phase AC power from 90 264V 50 or 60hz including the following common configurations: 120V - 240V AC single-phase Line, Neutral and safety ground 240V AC split-phase: The two phases must both measure 120V AC to ground. 208V AC single-phase Any 2 phases and safety ground The OpenEVSE P50S Standard is compatible with Level 2 ONLY can be powered by a single phase AC power from 208 264V 50 or 60hz including the following common configurations: 240V AC split-phase: The two phases must both measure 120V AC to ground. 208V AC single-phase Any 2 phases and safety ground 230V AC single-phase Line, Neutral and safety ground Users Guide 6

Specifications 7 Users Guide Model: P50A AC Input Operating Voltage 90-264 VAC, 1-Ph AC Frequency 50 or 60Hz AC Output 50A Circuit 6A - 40A Current 40A Circuit 6A - 32A 30A Circuit 6A - 24A 20A Circuit 6A - 16A Output Power 120 VAC 720 W - 2880 W 240VAC 1440 W - 9600 W Features Display Type LCD 16 Character 2 Lines Backlight Color Temperature Sensor Type DS3231 Real Time Clock Station Based Timers Current Measurement Display - kwh added Display - kwh total Add x kwh Session Options Charge x min Safety Power Interlock Pilot Signal Ground Monitoring Ground Fault Interrupt with self test 15ma - 20ma Welded Contact Detection Self test Power-on and before energizing 50% 65 C - 150 F 25% 68 C - 155 F Temperature Throttling Shutdown 71 C - 160 F Resume 100% 62 C - 145 F Electric Vehicle ID Ventilation Check Warranty Standard 3 Year Enclosure P50A-18 P50A-24 Weight 4.2kg - 9.3 lbs 4.4kg 9.7lbs Dimensions (H x W x D) mm 260 x 135 x 70 Inches 10.3 x 5.3 x 2.8

Specifications Model: P50S AC Input Operating Voltage 208-264 VAC, 1-Ph AC Frequency 50 or 60Hz AC Output 50A Circuit 6A - 40A Current 40A Circuit 6A - 32A 30A Circuit 6A - 24A 20A Circuit 6A - 16A Output Power 120 VAC 720 W - 2880 W 240VAC 1440 W - 9600 W Features Display Type LCD 16 Character 2 Lines Backlight Monochrome (White on Blue) Temperature Sensor Type MCP9808 Real Time Clock No Station Based Timers No Current Measurement Display - kwh added Display - kwh total Add x kwh Session Options Charge x min Safety Power Interlock Pilot Signal Ground Monitoring Ground Fault Interrupt with self test 15ma - 20ma Welded Contact Detection Self test Power-on and before energizing 50% 65 C - 150 F 25% 68 C - 155 F Temperature Throttling Shutdown 71 C - 160 F Resume 100% 62 C - 145 F Electric Vehicle ID Ventilation Check Warranty Standard 3 Year Enclosure P50S-18 P50S-24 Weight 4.2kg - 9.3 lbs 4.4kg 9.7lbs Dimensions (H x W x D) mm 260 x 135 x 70 Inches 10.3 x 5.3 x 2.8 Users Guide 8

Safety OpenEVSE was designed to comply with safety features required by standards documents for Electric Vehicle Charging from SAE J1772, NEC and UL. Note: The OpenEVSE P50 Charging Station has not been tested or certified by a Nationally Recognized Testing Laboratory. UL2251 Standard for Plugs, Receptacles and Couplers for Electric Vehicles UL2231 Standard for Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits SAE J1772 Electric Vehicle Conductive Charge Coupler Standard NEC Article 625 Electric Vehicle Charging System Equipment Power interlock OpenEVSE includes an interlock that de-energizes the electric vehicle connector and cable whenever the electrical connector is uncoupled from the electric vehicle (NEC 625.18) Pilot Signal OpenEVSE supports the SAE J1772 pilot signal which provides an automatic means to deenergize the cable conductors and electric vehicle connector upon exposure to strain that could result in either cable rupture or separation of the cable from the electric connector and exposure of live parts (NEC 625.19) (SAE J1772) Self Check OpenEVSE performs a Self-Testing sequence during start up to ensure unit is working properly and safely upon power-up OpenEVSE checks for: GFCI--Ability to respond to a 20mA ground fault Missing Ground Welded Relay Contact Monitor Pilot line status Ground Monitoring OpenEVSE checks ground during power-up and constantly monitors for presence of proper safety ground during operation. If ground is lost charging is discontinued. (SAE J1772) Ground Fault Interrupt 9 Users Guide

OpenEVSE includes mandatory Ground Fault Interruption. Fault sensitivity of 20ma trip for protection against electric shock of personnel. (NEC 625.22) (SAE J1772) (UL 2231) After each GFCI event OpenEVSE will retry charging up to 4 times after a 15 minute delay per event. (UL 2231) Ground Fault circuit tested during Power on Self-test. Stuck Relay detection OpenEVSE checks relay contacts on power up to ensure relays are functioning properly and providing proper power interlock. Electric Vehicle Identification OpenEVSE verify the pilot signal integrity by checking the Electric Vehicle Diode. The pilot signal must BOTH be at the correct resistance AND pass the "diode check" to activate the circuit. (SAE J1772) Ventilation Required OpenEVSE checks for the Ventilation Required request from Electric Vehicles with lead acid batteries (not common). By default OpenEVSE will deny charging if ventilation is not available. With additional hardware and firmware update OpenEVSE can allow Ventilation Required charging if the charging station is equipped to activate ventilation. (SAE J1772) Internal Temperature OpenEVSE Continuously monitors the internal temperature of the Charging Station and will shutdown if the internal temperature exceeds 71 C (160 F). Temperature Throttling OpenEVSE Actively reduces charging current during high temperature events in several steps beginning at 65 C (150 F). If temperature drops full current is restored. Charging will be halted if temperature exceeds a critical level. Users Guide 10

Installation 11 Users Guide

Users Guide 12

13 Users Guide

Users Guide 14

Operation Display The OpenEVSE P50 Advanced displays various colors based on state if equipped with a Red - Green - Blue (RGB) Liquid Crystal Display (LCD). The colors are: Color OpenEVSE State EV State J1772 State White Booting N/A N/A Green Ready Not Connected State A Yellow Ready Connected State B Blue Charging Charging State C Red Error N/A Error LCD Text The Standard LCD used on OpenEVSE P50 has 2 lines and 16 Characters per line. Top Line Left Side Ready Charging Error Stopped Waiting Sleeping OpenEVSE is ready OpenEVSE is ready to Charge OpenEVSE has detected an Error OpenEVSE has been stopped OpenEVSE is waiting for a timer OpenEVSE is sleeping Top Line Right Side The Right side displays information about the Service level and Current setting of the Pilot. In the "Ready" States the LCD displays the Service Level L1-120V or L2-240V and the Maximum current allowed by the Charging Station. Bottom Line The Bottom line displays information about the state of the Electric Vehicle and the current charging session. 15 Users Guide

EV Not Connected EV Connected OpenEVSE does not detect an EV OpenEVSE detected an EV While in the Charging state the LCD will display the watt hours added for the current session on the left and the Total Life time in kwh on the right. Real Time Clock The P50 Advanced includes a Real Time Clock which allows charging station based timers. See the Button Menu section to set the current time, Start and Stop times. These timers are independent of timers set on the vehicle. Battery - The P50 Advanced includes a CR1220 coin cell battery installed on the back side of the LCD. This battery can be replaced with a CR1216, CR1220 or CR1225 at the end of its life. Note the battery is not required for normal operations, it serves to keep time after a power failure. Users Guide 16

Button Menu Menu options can be accessed with the button. The menu operates on Long press and short press. All options are available in the "Ready" State. If a vehicle is connected only session options are available. Long Press - Press and hold down Short Press - Press and release To access the menu press the button and hold it down until the menu displays. Scroll through the options with a short press the button. Change the value of an option Press and hold. Scroll through the available values for that particular option short press. Select the desired value Press and hold. Button Menu Options LCD Type (Monochrome, RGB) o Monochrome - Single Color LCDs o RGB - Red, Green, Blue LCDs Service Level (L1, L2, Auto) o L1 - Level 1 Charging Only (120v) o L2 - Level 2 charging Only (200-240v) Recommended for International Users o Auto - Auto Detect L1 or L2 Default Current (Max 40A. Do not exceed 80% of Circuit/Breaker Rating) Set Time (Day, Month, Year, Hour, Minute) Start Time (Hour, Minute) Stop Time (Hour, Minute) Session Options o Charge Limit (add xxx kwh) o Time Limit (charge for xx minutes) For Advanced users only with specific need. The following safety features are enabled by default. Do not disable under normal circumstances. Any disabled Safety Features will be displayed on every boot. Vent Required (Enabled, Disabled) Stuck Relay Check (Enabled, DIsabled) Ground Check (Enabled, Disabled) GFCI Self Test (Enabled, Disabled) Temperature Check (Enabled, Disabled) 17 Users Guide

Power on Self Test Self Check OpenEVSE performs a Self-Testing sequence during start up and every time before beginning to charge to ensure all safety features are working properly including: GFCI--Ability to respond to a 20mA ground fault Missing Ground Welded Relay Contact Monitor Pilot line status with Vehicle Identification Internal Temperature Possible errors returned during the self test are: GFCI Self Test Failed Earth Ground Test Failed Stuck Relay Test Failed OpenEVSE did not detect a GFCI Fault during test OpenEVSE could not detect a Ground OpenEVSE read AC voltage before Relays were closed Check GFCI CT and Self test coil Check Ground Connections and AC_Test lines Check Relay and AC_Test Lines Errors GFCI FAULT NO GROUND STUCK RELAY VENT REQUIRED DIODE CHECK OVER TEMPERATURE OpenEVSE detected a ground leakage of > 20ma OpenEVSE lost connection to ground Power was detected when line should be open. OpenEVSE read a pilot signal at 3V OpenEVSE did not detect a Vehicle Temperature over 72C detected OpenEVSE will rerun GFCI self-test and retry charging. If Ground fault indicates immediate failure. Charging is suspended. If GFCI continues regularly Contact Support Check Electrical Ground, Contact Support Contact Support Ventilation requested by the Electric Vehicle. Ensure Charge handle is dry and clean. Contact Support. If outside air temperature is very hot, keep station out of direct sunlight and charge at lower current otherwise Contact Support. Users Guide 18

Additional Resources Online Solutions, Forums and Trouble Tickets http://support.openevse.com E-mail support@openevse.com Online Guides http://guides.openevse.com Store http://store.openevse.com Website http://www.openevse.com Source Code - Firmware - Schematics, etc. https://github.com/openevse 19 Users Guide