TSHD (SensyTemp Heavy Duty) Temperature sensor for particularly rough environments; Ex-certified, including Ex-d according to ATEX 10/10-3.

Similar documents
Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Temperature Measurement Resistance thermometers

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Resistance thermometer Model TR10-B, for additional thermowell

Thermocouples Model TC10-B, for Additional Thermowell

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Resistance thermometer Model TR10-E, for additional thermowell

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

FICHA TÉCNICA DE PRODUTO

SITRANS T measuring instruments for temperature

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Field instrumentation. Electropneumatic units. as I/P converters and positioners

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Electrical Linear Actuator RSD10 / RSD20 (Contrac)

EAS822 (Contrac) Power Electronic Unit

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Resistance thermometer Without thermowell Model TR10-H

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

RTD Temperature Sensor omnigrad M TR 15

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Omnigrad TA20, TA21. Technical Information. Temperature Measuring Technology Terminal heads for mounting on thermowells of resistance thermometers

RSD100 (Contrac) Electrical Linear Actuator

WedgeMaster FPD570 Compact wedge flowmeter. Combining durability with simplicity

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

POSITIONERS and Controls for Complete Valve Automation

Measuring insert for resistance thermometer Model TR10-A

TZIM. Electropneumatic Analog Positioner 10/ EN

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

BETA SWITCHES FOR HAZARDOUS AREA

Thermocouples Model TC10-E, for Additional Thermowell

Contrac RSD 200. Electrical Linear Actuator for Continuous Control Rated Force 200 kn 10/ EN. Application. Positioning:

Explosion Proof Equipment General Overview*

Thermocouple For additional thermowell Model TC10-B

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Thermocouple Without thermowell Model TC10-H

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

ORIMAS Mass Flowmeter

RTD Temperature Sensor omnigrad M TR 47, TR 48

Thermocouple Model TC10-H without thermowell

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

RTD Temperature Sensor omnigrad M- TR 11

Reed sensor For bypass level indicators Model BLR

Thermocouple Model TC10-E, for additional thermowell

International approvals.

Measuring insert for process resistance thermometer

Tubeskin thermocouple assembly Model TC59-V

A good connection. International approvals.

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

Shut-off valves and accessories for pressure measuring instruments

Explosion-protected surface-mounting Thermostat ATH-Ex Series

STEEMCO Flowmeter for Steam

Process Connections for Dial Thermometers

Surface thermocouple Model TC50

RTD Temperature Sensor omnigrad M- TR 13

Product specification

Omnigrad S -TC65. Technical Information

97100 NAMUR. Technical data

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Certificate of Conformity

Compact temperature switch Model TCS

CERTIFICATE OF COMPLIANCE

Product specification

Tubeskin thermocouple assembly Model TC59-V

Mini temperature switch Stainless steel switch enclosure Model TXS

Tubeskin thermocouple assembly Model TC59-W

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Series Level-Trol Electronic Liquid Level Transmitters

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Level Limit Switch liquiphant FTL 365 / FTL 366

AS-I

3/2-way Rocker Solenoid Valve for pneumatic systems

RTD Insert for Temperature Sensor omniset- TPR100

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Thermocouple with spring-loaded tip Model TC55

THE EXPERT IN LEVEL AND FLOW

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Technical Information Omnigrad S TR66, TC66

Magnetic Float Switches horizontal 1003-h

Unused flameproof threads for cable glands have to be closed with certified plugs.

Exhaust gas temperature sensors MBT 5113 and MBT 5116

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Transcription:

TSD (SensyTemp eavy Duty) Temperature sensor for particularly rough environments; Ex-certified, including Ex-d according to ATEX 10/10-3.28 E ighlights Particularly durable construction for high mechanical request igh-quality materials for aggressive environment salt water steady low copper aluminium connection head with 70 µm epoxy finish or stainless steel version Different explosion protection philosophies realisable costreducing for standard- and global oriented users Further features Ex-certification according to the new ATEX FM- and CSA-certified versions available Variable process connections Exchangeability of the insets during operation, on use of our certified types Available with display option Central spring inset according S-standards optionally available. An indicator is observable also from the side. Applications Oil exploration and pipelines Offshore (Petro-) chemical industry Machinery and protective measures Description The SensyTemp eavy Duty temperature sensor was developed particularly for applications with rough environmental conditions. In connection with special insets this sensor may be supplied as intrinsically safe explosion- or flameproof version. Global players can trust on one proven product concept all over the world and reduce consequently their costs of engineering, supply and storage.

TSD (SensyTemp eavy Duty) Temperature sensor for particularly rough environments Connection heads and standard assembly for transmitters with ceramic terminal block with transmitter, replaceable mounted on the inset with transmitter and digital display ead-mounted transmitters for Ex d- and on-ex-applications TR04 fixed measuring range TS02 PC programmable T02 programmable, ART TF12 PROFIBS PA for Ex i-applications TR04-Ex fixed measuring range TS02-Ex PC programmable T02-Ex programmable, ART TF12-Ex PROFIBS PA 2 05.04

TSD (SensyTemp eavy Duty) Temperature sensor for particularly rough environments General information Accessories Removable insets are already available and will be list in a separate Data Sheet Delivery time For scope of catalog 3 weeks, customized versions upon request Options other process connection other type of protection tube other tube material Certification/tests (please refer to Data Sheet 10/10-3.81 E) Further versions The available Data Sheet represents our standard delivery program. Technical data see Data Sheet 10-3.03 E. Further models are available on request. Special versions with drilled thermowells are also applicable with FM-/CSA-certification. As an option a second cable entry is available Overvoltage protection upon request ints for cost-effective engineering The use of standard components and lengths will reduce price and delivery time. Please consider the use of standardised nominal lengths, and emphasise on the importance of the insertion length. Applying welded tubes for example will allow the free choice of the insertion length. As a result, the extension length results from the difference between nominal and insertion length. Please note that the extension length shall not be less than 45 mm. Reliability, availability, security The SensyTemp eavy Duty was designed for rough environmental conditions. In order to fulfill those requirements, we only apply pre-selected and tested components. Please note the following limitations in regards to the design: Extension diameter min. 14 mm Process connection min. 1/2" or comparable Only applicable thermowells to be used Order code example Model number Model number Options, specify successively and separated by dash V10573-2XL2AB9-406-490-(=700)-0...500 C Components omponenten Blank text field i.e. for insertion length and measuring range 05.04 3

TSD (SensyTemp WT eavy Duty) Temperature sensor for particularly rough environments with welded tube and measuring inset Sensor design Connection heads Example without display AGL Aluminium Epoxy coating, 70 µm with digital display AGLD Aluminium Epoxy coating, 70 µm M20x1.5 M20x1.5 41 41 Process connection Welded thread cylindrically (G) conical (PT) Welded flange Protection tubes Type 3S for inset 6 mm Type B2S fast response time, for inset 3 mm D D S S E 50 E 39 Ø 6.5 Ø 3.5 Captions: D E S = ominal length = Extension length = Insertion length = Extension diameter 14 mm = Thermowell diameter 14 mm = Tip diameter = Wall thickness 4 05.04

TSD (SensyTemp WT eavy Duty) Temperature sensor for particularly rough environments with welded tube and measuring inset Ordering information Catalog o. Code ER Deliv. time Temperature sensor TSD (SensyTemp WT eavy Duty) V10573-216,00 Protection tube Type D x S Material E 3S 14 x 2,5 mm 1.4571 (AISI 316-Ti) 9 mm T - B2S 14 x 2,5 mm 1.4571 (AISI 316-Ti) 6 mm W 16,50 ominal length = 275 mm 1 - = 365 mm 2 6,18 = 515 mm 3,50 Connection head Cable entry M 20 x 1.5; prot. degr./-class IP 66/67/EMA 4 X Type Material AGL aluminium, epoxy painted G - AGLD incl. display aluminium, epoxy painted 1) 6,00 Explosion protection maximum operation temperature for Ex-areas 450 C on-explosion protected 0 - intrinsic safety II 1 G EEx ia IIC T6 PTB 01 ATEX 2200 X 1 13,40 flameproof II 1/2 G EEx d IIC T6 PTB 99 ATEX 1144 2 22,70 Error limit Class B E/IEC 60 751 2) A - Class A from 0...250 C E/IEC 60 751 2) 3) E 14,40 Class 2 E/IEC 60 584 4) G - Class 1 E/IEC 60 584 4) 6,18 Measuring inset 1 x Pt 100, 2-wire operation temperature -200...600 C A 16,50 1 x Pt 100, 3-wire operation temperature -200...600 C B,50 1 x Pt 100, 4-wire operation temperature -200...600 C C 18,50 2 x Pt 100, 2-wire operation temperature -200...600 C 5) D 19,60 2 x Pt 100, 3-wire operation temperature -200...600 C 6) E 50,50 1 x Type (i-cri) - 2 x Type (i-cri) J 10,30 ead mounted transmitter 7) without 0 - TR04 fixed measuring range Standard: 2 or 3-wire circuit 8) 9) 1 90,60 TS02 programmable 8) 6 212,00 T02 programmable, ART protocol 8) 9 238,00 TF12 PROFIBS-PA 8) 365,00 TR04-Ex fixed measuring range Standard: 2 or 3-wire circuit 9) 10) A 124,00 TS02-Ex programmable 10) F 241,00 T02-Ex programmable, ART protocol 10) J 264,00 TF12-Ex PROFIBS-PA 10) L 389,00 1) only possible with ead mounted transmitter (not with TF12) 2) only resistance thermometers 3) not for 2-wire, not for 2 x Pt100 4) only thermocouples 5) not for Ex i in prot. tube B2S 6) not for protection tube B2S 7) Transmitter TS02/TS02-Ex, T02/T02-Ex, TF12/TF12-Ex incl. parameterization Transmitter TR04/TR04-Ex incl. standard measuring range (clear text) 8) not for measuring inset with (PTB) EEx ia IIC T6 9) only for Pt100, standard measuring ranges in C: -30/60, 0/60, 0/100, 0/120, 0/150, 0/200, 0/250, 0/300, 0/400, 0/600 10) only for measuring inset with (PTB) EEx ia IIC T6 Other versions on request 05.04 5

TSD (SensyTemp WT eavy Duty) Temperature sensor for particularly rough environments with welded tube and measuring inset Additional ordering information Code ER Deliv. time Process connection Mounting thread G½, welded-on Mat. 1.4571 (AISI 316-Ti) Type A DI 3852 1) RB1 - Mounting thread G¾, welded-on Mat. 1.4571 (AISI 316-Ti) Type A DI 3852 1) RB2 37,10 Mounting thread G1, welded-on Mat. 1.4571 (AISI 316-Ti) Type A DI 3852 1) RB3 52,50 Mounting thread ½ PT, welded-on Mat. 1.4571 (AISI 316-Ti) 1) RB4 23,70 Mounting thread ¾ PT, welded-on Mat. 1.4571 (AISI 316-Ti) 1) RB5 40,20 Mounting thread 1 PT, welded-on Mat. 1.4571 (AISI 316-Ti) 1) RB6,50 Welded flange D 25, P 40, Type B1 Mat. 1.4571 (AISI 316-Ti) DI E 1092-1 1) F06 31,90 Welded flange D 50, P 40, Type B1 Mat. 1.4571 (AISI 316-Ti) DI E 1092-1 1) F11 102,00 Welded flange 1 300 Ibs. RF Mat. 1.4571 (AISI 316-Ti) 1) F18 80,30 Options Insertion length =...mm 1) 468 - Measuring range = (start value...end value C) 2) 680 - TAG-o. on stainless steel label 490 11,30 4-wire circuit TR04 / TR04-Ex TMP 41,20 1) Specify insertion length. Standard: = 160 for = 275, = 250 for = 365, = 400 for = 515 2) Transmitter TS02/TS02-Ex, T02/T02-Ex, TF12/TF12-Ex incl. parameterization Transmitter TR04/TR04-Ex incl. standard measuring range (clear text) Other versions on request 6 05.04

TSD (SensyTemp TW eavy Duty) Temperature sensor for particularly rough environments with drilled thermowell and measuring inset Sensor design Connection heads Example without display AGL Alu, Epoxy coating, 70 µm AGS stainless steel with digital display AGLD Alu, Epoxy coating, 70 µm AGSD stainless steel Digital display AGLD/AGSD M20x1.5 M20x1.5 41 41 M20x1.5 41 Extension, stainless steel nipple, 2 x ½ PT nipple & union, 2 x ½ PT Thermowell Type PW for weld-in Type PL with 1 PT thread for screw-in Type P with 1 PT thread for screw-in Process connection Threaded thermowell Welded onflange (optionally) Ø32 h11 1 PT Ø23 10 10 Type PW Ø 32 h11 Ø 23 L TypePW Ø32 T Type PL 10.2 25 min. 45 Type P Ø35 1 PT 10.2 25 Ø23 Ø27 1 PT Ø 7 L Ø7 L Cone length max. 400 L Cone length max. 400 Ø25 3 Ø6.5 Ø6.5 Ø13.5 3 Ø13.5 Ø16 Ø16 Captions: = ominal length = Extension length = Insertion length = Extension diameter 14 mm E = Tip diameter 05.04 7

TSD (SensyTemp TW eavy Duty) Temperature sensor for particularly rough environments with drilled thermowell and measuring inset Ordering information Catalog o. Code ER Deliv. time Temperature sensor TSD (SensyTemp TW eavy Duty) V10574-353,00 Thermowell Type Process connection Material PW Ø 32 mm 1.4404 (AISI 316 L) B - PL 1" PT 1.4404 (AISI 316 L) A 28,80 P 1" PT 1.4404 (AISI 316 L) C 28,80 Insertion length = 150 mm L = 215 mm 1 - = 300 mm L = 365 mm 2 152,00 Extension tube Type Thermow.- / ead- conn. Length Material nipple 1/2 " PT / 1/2" PT = 150 mm stainless steel Q - nipple & union 1/2 " PT / 1/2" PT = 150 mm stainless steel 36,10 Connection head Cable entry M 20 x 1.5; prot. degr./- class IP 66/67/EMA 4 X Type Material AGL aluminium, epoxy painted G - AGLD incl. display aluminium, epoxy painted 1) 6,00 AGS stainless steel L 103,00 AGSD incl. display stainless steel 1) 360,00 Explosion protection maximum operation temperature for Ex-areas 450 C on-explosion protected 0 - intrinsic safety II 1 G EEx ia IIC T6 PTB 01 ATEX 2200 X 1 13,40 flameproof II 1/2 G EEx d IIC T6 PTB 99 ATEX 1144 2 22,70 Error limit Class B E/IEC 60 751 2) A - Class A from 0...250 C E/IEC 60 752 2) 3) E 14,40 Class 2 E/IEC 60 584 4) G - Class 1 E/IEC 60 584 4) 6,18 Measuring inset 1 x Pt 100, 2-wire operation temperature -200...600 C A 16,50 1 x Pt 100, 3-wire operation temperature -200...600 C B,50 1 x Pt 100, 4-wire operation temperature -200...600 C C 18,50 2 x Pt 100, 2-wire operation temperature -200...600 C D 19,60 2 x Pt 100, 3-wire operation temperature -200...600 C E 50,50 1 x Type (i-cri) - 2 x Type (i-cri) J 10,30 ead mounted transmitter 5) without 0 - TR04 fixed measuring range Standard: 2 or 3-wire circuit 6) 7) 1 90,60 TS02 programmable 6) 6 212,00 T02 programmable, ART protocol 6) 9 238,00 TF12 PROFIBS-PA 6) 365,00 TR04-Ex fixed measuring range Standard: 2 or 3-wire circuit 7) 8) A 124,00 TS02-Ex programmable 8) F 241,00 T02-Ex programmable, ART protocol 8) J 264,00 TF12-Ex PROFIBS-PA 8) L 389,00 Continued on next page 1) only possible with ead mounted transmitter (not with TF12) 2) only resistance thermometers 3) not for 2-wire, not for 2 x Pt100 4) only thermocouples 5) Transmitter TS02/TS02-Ex, T02/T02-Ex, TF12/TF12-Ex incl. parameterization Transmitter TR04/TR04-Ex incl. standard measuring range (clear text) 6) not for measuring inset with (PTB) EEx ia IIC T6 7) only for Pt100, standard measuring ranges in C: -30/60, 0/60, 0/100, 0/120, 0/150, 0/200, 0/250, 0/300, 0/400, 0/600 8) only for measuring inset with (PTB) EEx ia IIC T6 Other versions on request 8 05.04

TSD (SensyTemp TW eavy Duty) Temperature sensor for particularly rough environments with drilled thermowell and measuring inset Ordering information (continued) Catalog o. Code ER Deliv. time Temperature sensor TSD (SensyTemp TW eavy Duty) V10574- Process connection without welded flange 0 - Welded flange 1 1/2" 150 lbs. RF 1.4571 (A 316-Ti) (Grade L on request) 1 80,30 Welded flange 1 1/2" 300 lbs. RF 1.4571 (A 316-Ti) (Grade L on request) 2 92,70 Welded flange 2" 150 lbs. RF 1.4571 (A 316-Ti) (Grade L on request) 3 94,80 Options Measuring range = (start value...end value C) 1) 680 - TAG-o. on stainless steel label 490 11,30 cable entry 1 x 1/2" PT 406 8,24 4-wire circuit TR04 / TR04-Ex TMP 41,20 1) Transmitter TS02/TS02-Ex, T02/T02-Ex, TF12/TF12-Ex incl. parameterization Transmitter TR04/TR04-Ex incl. standard measuring range (clear text) Other versions on request 05.04 9

TSD (SensyTemp ET eavy Duty) Temperature sensor for particularly rough environments for installation in a thermowell, with measuring inset Sensor design Connection heads Example without display AGL Alu, Epoxy coating, 70 µm AGS stainless steel with digital display AGLD Alu, Epoxy coating, 70 µm AGSD stainless steel M20x1.5 M20x1.5 41 41 Process connection nipple 2 x ½ PT nipple & union 2 x ½ PT with welded thread G½ or M18x1.5 with welded thread ½ PT 10 10 Sensor tip ØA ote: The thermometer SensyTemp ET eavy Duty is appropriate for the installation into a suitable thermowell. Only in this case, the request at explosion prevention and pressure strength can be fullfilled. Captions: E = ominal length = Extension length = Insertion length = Extension diameter 14 mm = Tip diameter 10 05.04

TSD (SensyTemp ET eavy Duty) Temperature sensor for particularly rough environments for installation in a thermowell, with measuring inset Ordering information Catalog o. Code ER Deliv. time Temperature sensor TSD (SensyTemp ET eavy Duty) V10575-6,00 Measuring inset Ø A = 6 mm 2 - Ø A = 3 mm 1 19,60 Extension tube Type Thermow.-/ead-conn. Length Material nipple 1/2 " PT / 1/2" PT = 150 mm stainless steel Q - nipple & union 1/2 " PT / 1/2" PT = 150 mm stainless steel 36,10 mount.-thread M 18 x 1.5 / M 24 x 1.5 = 150 mm stainless steel D - mount.-thread 1/2 " PT / M 24 x 1.5 = 150 mm stainless steel I - mount.-thread G 1/2 " / M 24 x 1.5 = 150 mm stainless steel 9 - Insertion length = 125 mm 1 - = 215 mm 2 1,03 = 365 mm 3 4,12 =... mm to be specified (max. 835 mm) X call Connection head Cable entry M 20 x 1.5; prot. degr./-class IP 66/67/EMA 4 X Type Material AGL aluminium, epoxy painted G - AGLD incl. display aluminium, epoxy painted 1) 6,00 AGS stainless steel L 103,00 AGSD incl. display stainless steel 1) 360,00 Explosion protection maximum operation temperature for Ex-areas 450 C on-explosion protected 0 - intrinsic safety II 1 G EEx ia IIC T6 PTB 01 ATEX 2200 X 1 13,40 flameproof II 1/2 G EEx d IIC T6 PTB 99 ATEX 1144 2 22,70 Error limit Class B E/IEC 60 751 2) A - Class A from 0...250 C E/IEC 60 751 2) 3) E 14,40 Class 2 E/IEC 60 584 4) G - Class 1 E/IEC 60 584 4) 6,18 Measuring inset 1 x Pt 100, 2-wire operation temperature -200...600 C A 16,50 1 x Pt 100, 3-wire operation temperature -200...600 C B,50 1 x Pt 100, 4-wire operation temperature -200...600 C C 18,50 2 x Pt 100, 2-wire operation temperature -200...600 C D 19,60 2 x Pt 100, 3-wire operation temperature -200...600 C 5) E 50,50 1 x Type (i-cri) - 2 x Type (i-cri) J 10,30 Continued on next page 1) only possible with ead mounted transmitter (not with TF12) 2) only resistance thermometers 3) not for 2-wire, not for 2 x Pt100 4) only thermocouples 5) only for 6 mm inset Other versions on request 05.04 11

TSD (SensyTemp ET eavy Duty) Temperature sensor for particularly rough environments for installation in a thermowell, with measuring inset Ordering information (continued) Catalog o. Code ER Deliv. time Temperature sensor TSD (SensyTemp ET eavy Duty) V10575- ead mounted transmitter 1) without 0 - TR04 fixed measuring range Standard: 2 or 3-wire circuit 2) 3) 1 90,60 TS02 programmable 2) 6 212,00 T02 programmable, ART protocol 2) 9 238,00 TF12 PROFIBS-PA 2) 365,00 TR04-Ex fixed measuring range Standard: 2 or 3-wire circuit 3) 4) A 124,00 TS02-Ex programmable 4) F 241,00 T02-Ex programmable, ART protocol 4) J 264,00 TF12-Ex PROFIBS-PA 4) L 389,00 Options Measuring range = (start value...end value C) 1) 680 - TAG-o. on stainless steel label 490 11,30 cable entry 1/2" PT 406 8,24 4-wire circuit TR04 / TR04-Ex TMP 41,20 1) Transmitter TS02/TS02-Ex, T02/T02-Ex, TF12/TF12-Ex incl. parameterization Transmitter TR04/TR04-Ex incl. standard measuring range (clear text) 2) not for measuring inset with (PTB) EEx ia IIC T6 3) only for Pt100, standard measuring ranges in C: -30/60, 0/60, 0/100, 0/120, 0/150, 0/200, 0/250, 0/300, 0/400, 0/600 4) only for measuring inset with (PTB) EEx ia IIC T6 Other versions on request 12 05.04

TSD (SensyTemp eavy Duty) Temperature sensor for particularly rough environments Version with center spring according S-standard Widespread on the American markets are measuring insets with a spring loading in the extension. The below listed versions provide this feature. Even, the exchange of the measuring inset requires more effort, the solution may also be applied as integral sensor assemblies in conjunction with field mounted temperature transmitters. This option enables the observation of the display in a 90 angle in relation to the thermowell. Devices with central spring are available, as on-ex-, Intrinsically save (EEx i)- and explosionproof (EEx d) version according ATEX. Field housing devices without sensors approved by ATEX/FM/CSA, please refer to data sheets: 10/11-8.59 E analog device 10/11-8.62 E PC programmable device 10/11-8.64 E programmable, ART 10/11-8.70 E Profibus PA Axial head mounting with ceramic terminal block with transmitter with transmitter and digital display Integral thermometer assembly with ceramic terminal block with transmitter with transmitter and digital display 05.04 13

ABB Ltd. Salterbeck Trading Estate Workington, Cumbria CA14 5DS Tel: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. 125 E. County Line Road Warminster, PA 18974 SA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products Gmb Borsigstr. 2 63755 Alzenau Germany Tel: +49 551 905-534 Fax: +49 551 905-555 Technische Änderungen vorbehalten. Printed in the Fed. Rep. of Germany 10/10-3.28 E 05.04