YOUR POWER IN SAFE HANDS. E Series UPS

Similar documents
MKN-DSP SERIES - THREE PHASE

D Series: UPS UPTO - 300KVA - Three / Three Phase

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

EFFEKTA Power Supplies

Master Plus kva

Technical data sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Master DIALOG INDUSTRY RANGE

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

TECHNICAL DATA SHEET KVA UPS Systemss

On-line, Single Phase, Double Conversion UPS

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheets

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Series 120/120VAC Universal Tower/Rack Mount

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Technical Data Sheets

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

PowerValue 11/31 T kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Power+ CLASSIC. 20/30 kva, 3x208 Vac

POWER kva

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Industrial PFC UPS System

Technical Specification SENTINEL PRO

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Technical Data Sheets

TLE Series UPS 400/500 kw With eboost Technology

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Technical Data Sheets

Aurora Single Phase Emergency Lighting Inverters

UPS Multi Power 1-28 x 42 kw up to 1MW

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

TLE Series UPS 160/200/225/250 kw with eboost Technology

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS Multi Sentry 10-20kVA

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Liebert. FP 50Z kva

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Technical Data Sheets

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

Onfiniti. 1 Phase UPS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 750/1000 kw With eboost Technology

Technical Data Sheets

Master MPS kva kva 3:1 3:3 VFI TYPE

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Est FlexiPower Mini UPS FPX Mini kVA

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Three Phase UPS Systems Range: 10 to 500kVA

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

MGE TM Galaxy TM 7000

HAIRF UPS. X5 Series KVA

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

PowerScale TECHNICAL SPECIFICATIONS

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

60 to 160 kva.

Master Plus kva

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Technical Data Sheets

Technical data sheets

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

» Sophisticated» Reliable» Intelligent

MGE TM Galaxy TM 7000 GFC

Transcription:

E Series UPS YOUR POWER IN SAFE HANDS

E Series UPS Secure Power The E Series UPS range from Dale Power Solutions Contents 1 Introduction 2 E-Series UPS Power Matrix 4 E200 Series 1 3kVA 6 E200 Series 6 10kVA 8 E200 Series 10 20kVA 10 E200R Series 1 3kVA 12 E200R Series 6 10kVA 14 E200R+ Series 1 3kVA 16 E300 Series 160 300kVA 20 E400 Series 20 120kVA 24 E600 Series 4 200kVA 28 Total Power Solutions 29 UPS Service & Support 30 Corporate & Social Responsibility 31 Settings New Standard 32 Dale Power Solutions Overview Keeping the power secure.

Setting the benchmark in UPS solutions Your total power solutions partner In an uncertain world, where rocketing demand is putting a strain on power supplies, you need the total confidence in your back-up power that Dale provides. Select from our standard range of UPS and generators, or our secure power projects providing your ideal standby power solution. Our integrated UPS and generator solutions provide no-break power, saving you from costly outages and downtime. We deliver flexible, innovative and cost effective secure power solutions, service and maintenance and manage the complete lifecycle of your equipment. Manufacturing excellence Operating lean and efficient 6 Sigma designed working practices, we ensure that your exact requirements are met - from design to a finished product of the highest quality and reliability. All systems are built and tested, including customer witness testing, under the highest levels of quality control. Outstanding features Features include internal failsafe bypass, extended run times, and high input power factor. With maximum reliability and power availability you can connect several units in parallel. The E Series has multi-language touch screen displays, remote monitoring, an advanced IGBT rectifier, back-feed protection and is configurable for redundancy. Future proof modular flexibility A modular approach to system design includes hot-swappable modules ensuring maximum up time. Your power solution lifecycle is totally flexible with ease of maintenance and expandability. As your power requirement grows so can your power solution, guaranteeing continued reliability. Safe removal and insertion of the UPS modules ensure no risk to the critical load. Protecting the environment Our systems are designed and manufactured using the minimum amount of resources, can be upgraded or refurbished to reduce material consumption and extend product life, and can be safely recycled, avoiding the need for system disposal. The E Series is designed with selectable ECO-mode, guaranteeing high operation efficiency. Unrivalled service and support Outstanding service and maintenance support is backed by more than 77 years experience, a worldwide team of service personnel, access to a comprehensive parts and spares archive and 24/7 expert help available. Leading edge technology The outstanding E series uses double conversion technology (VFI) with the UPS load powered continuously by the inverter. This guarantees that the critical UPS load receives a stable, clean, regulated sinusoidal power supply. Expert project management, installation and commissioning Your system is in expert hands. Project managers work with you to plan, control and co-ordinate everything from order placement, design and manufacture to installation. Our engineers join you on site to install and commission your equipment. www.dalepowersolutions.com 01

E Series UPS Secure Power E-Series UPS Power Matrix At a glance E200 E200R E200R+ E300 Power (kva) 1:1 3:1 1:1 3:1 1:1 3:3 1 kva 2 kva 3 kva 4 kva 6 kva 10 kva 15 kva 20 kva 40 kva 60 kva 80 kva 100 kva 120 kva 160 kva 200 kva 250 kva 300 kva 02

E400 E600 E600 Module 3:3 1:1 3:1 3:3 1:1 3:1 3:3 www.dalepowersolutions.com 03

E Series UPS Secure Power E200 Series An Advanced UPS Technology 1:1 Phase 1 3 kva FEATURES 3 High frequency, double conversion on-line technology 3 Fully digital DSP control 3 User friendly LCD interface 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EE battery packs available 3 E suffix models have no internal battery and increased charging capacity BATTERY PACK Intelligent Slot options: RELAY CARD SNMP CARD OR 04

SPECIFICATIONS UPS Model E201(E) E202(E) E203(E) Capacity 1000VA / 700W 2000VA / 1400W 3000VA / 2100W Input Voltage Range 115V AC 295V AC, load < 70% 160V AC 295V AC, load > 70% Phase Single phase Frequency 46 54Hz ±0.5Hz or 56 64Hz ±0.5Hz (auto sensing) Power Factor 0.97 Output Voltage 208 / 220 / 230 / 240V AC ±2% Phase Single phase Frequency Range 50 / 60Hz ±0.2% (auto selected at start up) w (Linear Load) < 3% THD (Non-Linear Load) < 6% Overload Capability >110% for 30 sec then transfer to bypass >150% for 0.3 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.7 Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm Battery mode: Inverter turns off after 5 cycles & provides an alarm Bypass mode: AC input fuse blows or circuit breaker operates Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency 83% 85% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 24V DC 48V DC 72V DC Battery 2 12V / 9Ah 4 12V / 9Ah 6 12V / 9Ah Backup Time At Half Load 11 mins 11 mins 11 mins Backup Time At Full Load 4 mins 4 mins 4 mins Charge Current Internal Battery: 1A External Battery: 4A (E suffix) Recharge Time 90% capacity after 8 hours charging Environment Temperature 0 C to +40 C Relative Humidity 0 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25 C to +55 C Communication Standard: RS232, USB Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 45dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 10.0kg / E suffix 5.2kg 21.0kg / E suffix 11.0kg 25.0kg / E suffix 11.0kg Dimensions (H W D) 215 144 361 mm 337 191 428 mm Standard Accessories Control Software Yes Yes Yes Input & Output Leads Yes Yes Yes Data Lead Yes Yes Yes User Manuals Yes Yes Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. APPLICATION Server, Telecommunications, Networking, Desktop, CCTV www.dalepowersolutions.com 05

E Series UPS Secure Power E200 Series An Advanced UPS Technology 1:1 Phase 6 10 kva 0.8PF FEATURES 3 High frequency, double conversion on-line technology 3 Fully digital DSP control 3 Wide input voltage range 3 Integral hot-swap maintenance bypass module 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Parallel capacity or redundancy (maximum 4 units) 3 Optional Emergency Power Off facility 3 Smart RS232 communications with monitoring software 3 Optional relay or SNMP communications card 3 Matching EE2000 battery packs available 3 E suffix models have no internal battery and increased charging capacity BATTERY PACK Intelligent Slot options: RELAY CARD SNMP CARD PARALLEL L CARD 06

SPECIFICATIONS UPS Model E206 E206E E2010 E2010E Capacity 6000VA / 4800W 10000VA / 8000W Input Voltage Range 120V AC 276V AC Phase Single phase Frequency 40 70Hz Power Factor 0.99 Output Voltage 220 / 230V AC ±2% Phase Single phase Frequency Range 50 / 60Hz (user adjustable) THD (Linear Load) 2% THD (Non-Linear Load) 6% Overload Capability 130% load for 10 min then transfer to bypass > 130% load for 1 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.7 (16 or 18 12V batteries) or 0.8 (20 12V batteries) Short Circuit Protection On-line mode: 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms Battery mode: 5 duration, inverter turns off, bypass unavailable, unit alarms Bypass mode: Input fuse blows or breaker operates, no alarm Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: 90% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 192V DC 192 / 216 / 240V DC 192V DC 192 / 216 / 240V DC Battery 16 12V / 9Ah 16 / 18 / 20 12V 16 12V / 9Ah 16 / 18 / 20 12V Backup Time At Half Load 14.3 min Depends on ext. battery 6.5 min Depends on ext. battery Backup Time At Full Load 5.5 min Depends on ext. battery 2.5 min Depends on ext. battery Charge Current 1.0A 1.0 6.0A (selectable) 1.0A 1.0 6.0A (selectable) Recharge Time 90% capacity after 8 hrs Depends on ext. battery 90% capacity after 8 hrs Depends on ext. battery Environment Temperature 0 C to +40 C Relative Humidity 0 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25 C to +55 C Communication Standard: RS232 Optional: USB, SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 77kg (nett) / 84kg (gross) 35kg (nett) / 42kg (gross) 80kg (nett) / 87kg (gross) 38kg (nett) / 45kg (gross) Dimensions (H W D) mm 655 250 590 mm 655 250 590 mm Standard Accessories Control Software Yes Input & Output Leads Optional extra Battery Leads Optional extra Data Lead & User Manual Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. APPLICATION Server, Telecommunications, Networking, Desktop, CCTV www.dalepowersolutions.com 07

E Series UPS Secure Power E200 Series An Advanced UPS Technologyogy 3:1 Phase 10 20kVA 0.8PF FEATURES 3 High frequency, double conversion on-line technology 3 Fully digital DSP control 3 Wide input voltage range 3 Integral hot-swap maintenance bypass module on E2310(E) model 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Parallel capacity or redundancy (maximum 4 units) 3 Optional Emergency Power Off facility 3 Smart RS232 communications with monitoring software 3 Optional relay or SNMP communications card 3 Matching EE2000 battery packs available for E2310(E) model 3 E suffix models have no internal battery and increased charging capacity Intelligent Slot options: RELAY CARD SNMP CARD PARALLEL L CARD 08

SPECIFICATIONS UPS Model E2310 E2310E E2315E E2320E Capacity 10000VA / 8000W 10000VA / 8000W 15000VA / 12000W 20000VA / 16000W Input Voltage Range 176V AC to 275V AC Line Neutral Phase 3 Phase 4 Wire & Earth Frequency 40 70Hz Power Factor 0.99 Output Voltage 220 / 230V AC ±2% Phase Single phase Frequency Range 50 / 60Hz (user adjustable) THD (Linear Load) 2% THD (Non-Linear Load) 6% Overload Capability 130% load for 10 min then transfer to bypass > 130% load for 1 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.7 (16 or 18 12V batteries) or 0.8 (20 12V batteries) Short Circuit Protection On-line mode: 5 cycle duration, inverter turns off, no transfer to bypass, unit alarms Battery mode: 5 duration, inverter turns off, bypass unavailable, unit alarms Bypass mode: Input fuse blows or breaker operates, no alarm Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: 90% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 192V DC 192 / 216 / 240V DC Battery 16 12V / 9Ah 16 / 18 / 20 12V blocks Backup Time At Half Load 6.5 min Depends on external battery Backup Time At Full Load 2.5 min Depends on external battery Charge Current 1.0A 1.0 6.0A (selectable) Recharge Time 90% capacity after 8 hours Depends on external battery Environment Temperature 0 C to +40 C Relative Humidity 0 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25 C to +55 C Communication Standard: RS232 Optional: USB, SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level < 55dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 80kg 40kg 45kg 45kg Dimensions (H W D) mm 655 250 590 mm 655 250 590 mm Standard Accessories Control Software Yes Yes Input & Output Leads Optional extra Optional extra Battery Leads Not applicable Optional extra Data Lead & User ManualYes Yes Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. APPLICATION Server, Telecommunications, Networking, Desktop, CCTV www.dalepowersolutions.com 09

E Series UPS Secure Power E200R Series An Advanced UPS Technology 1:1 Phase 1 3 kva 0.8PF FEATURES 3 High frequency, double conversion on-line technology 3 Rotatable LCD suitable for 19" rack or slim tower 3 Fully digital DSP control 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EER battery packs available 3 E suffix models have no internal battery and increased charging capacity BATTERY TERY PACK Intelligent Slot options: RELAY CARD SNMP CARD OR 10

SPECIFICATIONS UPS Model E201R(E) E202R(E) E203R(E) Capacity 1000VA / 800W 2000VA / 1600W 3000VA / 2400W Input Voltage Range 115V AC 295V AC, load < 70% 160V AC 295V AC, load > 70% Phase Single phase Frequency 46 54 ±0.5Hz or 56 64Hz ±0.5Hz (auto sensing) Power Factor >0.98 Output Voltage 220 / 230 /240V AC ±2% (factory set) Phase Single phase Frequency range 50 / 60Hz ±0.2% THD (Linear Load) < 3% THD (Non-Linear Load) < 6% Overload Capability >110% for 30 sec then transfer to bypass >150% for 0.3 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.8 Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm Battery mode: Inverter turns off after 5 cycles & provides an alarm Bypass mode: AC input fuse blows or circuit breaker operates Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: 87% On-line mode: 88% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 24V DC 48V DC 72V DC Battery 2 12V / 9Ah 4 12V / 9Ah 6 12V / 9Ah Backup Time At Half Load 10 mins 10 mins 10 mins Backup Time At Full Load 4 mins 4 mins 4 mins Charge Current Internal battery: 1A External battery: 4A (E suffix) Recharge Time 90% capacity after 8 hours charging Environment Temperature 0 C to +40 C Relative Humidity 0 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25 C to +55 C Communication Standard: RS232, USB Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level Safety & EMC < 45dBA CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 12.0kg / E suffix 7kg 21.1kg / E suffix 11.5kg 26kg / E suffix 14.5kg Dimensions (H W D) 400 380 86.5 mm 440 520 131 mm Standard Accessories Control Software Yes Yes Yes Input & Output Leads Yes Yes Yes Data Lead Yes Yes Yes User Manuals Yes Yes Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. APPLICATION Server, Telecommunications, Networking, Desktop, CCTV www.dalepowersolutions.com 11

E Series UPS Secure Power E200R Series An Advanced UPS Technology 3:1 or 1:1 6 10 kva 0.9PF FEATURES 3 High frequency, double conversion on-line technology 3 Input can be configured for either 3:1 or 1:1 operation 3 Rotatable LCD suitable for 19" rack or slim tower 3 Fully digital DSP control 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Up to 4 units can be operated in parallel 3 Emergency Power Off facility 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EER2000 battery pack available BATTERY PACK Intelligent Slot options: RELAY CARD SNMP CARD OR 12

SPECIFICATIONS UPS Model E21306RE E21310RE Capacity 6000VA / 5400W 10000VA / 9000W Input Rated Voltage 380 / 400 / 415V AC or 220 / 230 / 240V AC Voltage Range 120V AC 276V AC Line Neutral or 208V AC 478V AC Line Line Phase 3 Phase 4 Wire & Earth or 1 Phase 2 Wire & Earth Frequency 40 70Hz Power Factor 0.99 Output Voltage 220 / 230 / 240V AC ±2% Phase Single phase Frequency Range 50 / 60Hz ± 0.2Hz (user adjustable) THD (Linear Load) 2% THD (Non-Linear Load) 5% Overload Capability AC Mode: 110% for 3 min, 125% for 30 sec, 150% for 1 sec, >150% shutdown immediately, transfer to bypass Battery Mode: 110% for 30 sec, 125% for 1 sec, 150% for 0.2 sec, >150% shutdown immediately Crest Factor 3:1 (max) Power Factor 0.9 Short Circuit Protection Yes Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: 90% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 192 / 216 / 240V DC Backup Time At Half Load Depends on the external battery capacity Backup Time At Full Load Charge Current 6A (Maximum) Recharge Time 90% capacity after 8 10 hours charging Environment Temperature 0 C to +40 C Relative Humidity 0 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25 C to +55 C Communication Standard: USB, RS485 & Parallel Port Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level Safety & EMC < 55dBA CE marked to EN62040-1-1:2008 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 23.0 kg 25.0 kg Dimensions (H W D) 131 443 580 mm Standard Accessories Control Software Yes Yes Input & Output Leads Yes Yes Data Lead Yes Yes User Manuals Yes Yes Battery Leads Optional extra Optional extra Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. APPLICATION Server, Telecommunications, Networking, Desktop, CCTV www.dalepowersolutions.com 13

E Series UPS Secure Power E200R+ Series An Advanced UPS Technology 1:1 Phase 1 3 kva 0.9PF FEATURES 3 High frequency, double conversion on-line technology 3 Rotatable LCD suitable for 19" rack or slim tower 3 Fully digital DSP control 3 Wide input voltage range 3 Cold start function 3 Advanced battery management 3 Selectable ECO mode for high efficiency operation 3 Automatic battery charge in UPS off mode 3 Lightning and surge protection 3 Short circuit and overload protection 3 Automatic fan speed control with load variation 3 Emergency Power Off facility 3 Smart RS232 communications with monitoring software 3 USB communications port included 3 Optional relay or SNMP communications card 3 Matching EER+ battery packs available 3 Programmable load shedding in battery mode BATTERY TERY PACK Intelligent Slot options: RELAY CARD SNMP CARD OR 14

SPECIFICATIONS UPS Model E201R+ E202R+ E203R+ Capacity 1000VA / 900W 2000VA / 1800W 3000VA / 2700W Input Voltage Range 160V AC 295V AC Phase Single phase Frequency 46 54Hz ±0.5Hz or 56 64Hz ±0.5Hz (auto sensing) Power Factor >0.98 Output Voltage 200 / 208 / 220 / 230 / 240V AC ±2% (factory set) Phase Single phase Frequency Range 50 / 60Hz ±0.02Hz THD (Linear Load) < 3% THD (Non-Linear Load) < 5% Overload Capability Up to 130% for 30 sec then transfer to bypass 130% 200% for 0.3 sec then transfer to bypass >200% for 0.2 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.9 Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm Battery mode: Inverter turns off after 5 cycles & provides an alarm Bypass mode: AC input fuse blows or circuit breaker operates Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency 89% AC mode 84% battery mode Battery Model 12V valve regulated lead acid maintenance free DC Voltage 36V DC 72V DC 72V DC Battery 3 12V / 9Ah 6 12V / 9Ah 6 12V / 9Ah Backup Time At Half Load 14 mins 14 mins 8 mins Backup Time At Full Load 5 mins 5 mins 3 mins Charge Current Internal battery: 1A Recharge Time 90% capacity after 5 hours charging Environment Temperature 0 C to +40 C Relative Humidity 0 90% (non-condensing) Altitude 1500m maximum Storage Temperature -25 C to +55 C Communication Standard: RS232, USB Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise Level Safety & EMC < 55dBA CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 18.7kg 31.3kg 33.0kg Dimensions (H W D) 86.5 440 430 mm 86.5 440 690 mm Standard Accessories Control Software Yes Yes Yes Input & Output Leads Yes Yes Yes Data Lead Yes Yes Yes User Manuals Yes Yes Yes Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. APPLICATION Server, Telecommunications, Networking, Desktop, CCTV www.dalepowersolutions.com 15

E Series UPS Secure Power E300 Series An Advanced UPS Technology 3:3 Phase 160 300kVA 0.8PF FEATURES 3 Cutting edge technology, high frequency double conversion on-line UPS 3 Fully digitised microprocessor control 3 Parallel capacity or redundancy (maximum 16 units) 3 Wide input voltage range from single or dual source 3 Open architecture design provides full access for servicing 3 Intelligent battery charge management 3 RS232/RS485 communication with monitoring software 3 Short circuit and overload protection 3 Over temperature and over humidity protection 3 EMI and RFI noise filtering 3 Line interactive ECO mode 3 Large user friendly LCD interface 3 Cold start and programmable auto re-start functions 3 Fan speed auto control with load variation 3 Built-in static and maintenance bypass switches 3 Back feed protection between UPS output and mains supply 3 Emergency Power Off function 3 Low THD and high input power factor for diverse generator compatibility 3 Soft start with programmable power walk-in 3 Optional temperature compensated battery charging 3 Optional SNMP, relay card and remote monitoring panel 3 Optional galvanic isolation transformer Intelligent Slot options: RELAY CARD SNMP CARD 16

The Dale E300 series is the innovative new generation of high frequency, on-line double conversion Uninterruptible Power Supplies. Full DSP controlled inverter technology ensures continuous, clean, true sinusoidal power to critical applications under a wide range of conditions. Available in output power capacities from 160 to 300kVA, all with three phase input and output. The E300 series UPS is the new industry flagship in uninterruptible power supplies. Innovative and inspired in concept, designed and manufactured with engineering precision to deliver pure, resilient power to the most critical of applications. COMMON SPECIFICATIONS Input Voltage Range 176V AC to 264V AC Line-Neutral Phase Frequency 3 Phase 4 Wire & Earth 50 / 60Hz ±10% (user adjustable) Power Factor > 0.99 Output Voltage 220 / 230V AC Line-Neutral (user adjustable) Phase Frequency range 3 Phase 4 Wire & Earth 50 / 60Hz (user adjustable) THD (Linear Load) < 2% THD (Non-Linear Load) < 3% Efficiency On-line mode: 93% ECO mode: 98% Overload Capacity 125% load for 10 min, 150% load for 1 min Crest Factor 3:1 Power Factor 0.8 Short Circuit Protection Waveform Transfer Time IGBT controlled electronic protection True sine wave 0ms (on-line mode) Battery External 50 12V mono blocks (600V DC Nominal) Environment Altitude 1000m at rated power Operate Temperature 0 C to 40 C Relative Humidity 0 95% (non-condensing) Communication Standard: RS232 / RS485 Optional: SNMP and relay cards, remote monitoring panel LCD Screen Display Operation mode LED Indication Noise Level Safety & EMC Standard Accessories Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass Double conversion on-line or ECO line interactive (user selectable) Mimic panel overview of UPS operation and alarms <60dBA CE marked and tested to EN62040-1-1, IEC60950 & EN62040-2 Class A Control software, data lead & user manual MODEL SPECIFICATIONS Model Output Ratings Full Load Battery DC Audible Noise Physical Number (kva) (kw) Efficiency Voltage (dba) Nett Weight (kg) Dims (mm) (H W D) E3160 160 128 93% 600V < 60 550 1900 1050 800 E3200 200 160 93% 600V < 60 575 1900 1050 800 E3250 250 200 93% 600V < 60 700 1900 1500 800 E3300 300 240 93% 600V < 60 750 1900 1500 800 Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. www.dalepowersolutions.com 17

E Series UPS Secure Power E300 Series + DSP Power Factor Corrected IGBT Rectifier Latest IGBT power factor correction technology provides an input power factor close to unity ( 0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads. The high input power factor leads to reduced electricity consumption, minimised switchgear and circuit protection, cabling and generator requirements, thus reducing investment cost. Parallel and Redundant Operation Capability to connect up to 16 units in parallel to provide increased power capacity or redundancy. All parallel units can be operated from the front panel of any UPS. POWER INCREASE Units can be connected in parallel to increase the total capacity of the system. When an inverter goes offline, the critical loads are automatically transferred to bypass. REDUNDANCY Units can be connected in parallel to provide redundancy for absolute reliability. In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes offline, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption. Advanced Battery Management Intelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel. Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining). Temperature compensated battery charging monitors are available to monitor the internal and external battery temperature with a feedback control loop to adjust the charge current rate accordingly. Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load. The batteries can also be hot-swapped without disconnection of the UPS. DSP Controlled IGBT Inverter The DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads. The DSP circuitry is embedded within a single control board to reduce hardware and improve noise immunity. Complex control algorithms are utilised with floating point controllers to ensure uninterrupted operation and protection of the loads in abnormal conditions that may cause failure. The DSP control system achieves fast dynamic response for non-linear loads and high power factor under various load conditions. Static & Manual (Maintenance) Bypass Static and manual bypass switches are included as standard, with operational characteristics as follows: STATIC BYPASS This feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line. To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics. MANUAL BYPASS This feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load. Single or Dual Source Operation To increase flexibility, the UPS input can be fed by single or dual sources. In dual configuration, the rectifier is fed from the utility (main source), and the static and maintenance bypasses are fed from a secondary source. Open Architecture Design The UPS incorporates an open architecture design to facilitate full access to replace parts quickly and easily, resulting in low Mean Time To Repair (MTTR). Excellent Generator Compatibility Thanks to the robust IGBT rectifier, the E300 series UPS is uniquely compatible with a diverse range of sources, in particular, generators. Input current total harmonic distortion (THDi) of less than 3% is 18

achieved without compromising efficiency. The high input power factor enables a generator to be utilised with a power rating only 20% higher than the UPS. Power walk-in can be adjusted from 5 to 15 seconds. Based on the current measured on the input, the UPS gradually increases the power supplied from the utility source to the load. The power, delivered by the utility source to the load, varies according to the input voltage, current and power factor. Back Feed Protection Back feed protection prevents current from the UPS output feeding back to the UPS input terminals, thereby protecting maintenance personnel from electric shock hazards whilst working on the incoming supply side of the system. Reverse Energy Tolerance for Regenerative Loads The E300 series UPS is suitable for use with regenerative loads, such as synchronous motors. Regenerative loads pump energy back to the mains supply. Traditionally, UPS systems would burn this feedback energy, resulting in lower operating efficiency. The IGBT rectifier in the E300 series UPS is capable of absorbing intermittent load generated power. This reverse power tolerance facilitates the execution of important system operations, such as closed transition transfers of the UPS load directly to an engine generator source. Lower Total Cost of Ownership The high efficiency operation of the UPS means that less energy is consumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements. With reduced THDI and high 0.99 input power factor, switchgear, circuit protection, cabling and generator requirements are minimised, thus reducing investment cost. Advanced User Interface The UPS operating information and parameter settings are displayed in 4 different languages and can be accessed using the large user friendly, data rich LCD and system LED mimic panel. The UPS is capable of recording up to 500 events. Green ECO Mode of Operation The E300 series UPS can be operated in high efficiency ECO mode (98%) providing green energy savings through reduced power consumption. Emergency Power Off (EPO) The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging. With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened. Auto Re-start When the utility and bypass sources fail, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of Discharge threshold, the UPS will shut down. The UPS will automatically re-start once the utility power is restored and output power to the load will be delivered. The UPS also incorporates a programmable automatic start time delay. Advanced Communications A wide range of advanced communication options are available: EXTERNAL BATTERY TEMPERATURE SENSOR One module is fitted to each external battery cabinet to monitor the battery temperature. A feedback control loop within the UPS adjusts the charge current based on the battery temperature, optimising battery performance and longevity. RELAY ALARMS CARD Isolated, volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Fully programmable to facilitate the capture of a diverse range of operating and alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely. RS232/RS485 SERIAL PORT The UPS operating parameters can be observed and controlled locally using an RS232/RS485 communications port. Real time notification of changes in UPS status is reported to users by SMS or e-mail. SNMP NETWORK CARD Enables monitoring and control of the UPS operation by ethernet or internet connection. Allows the remote execution of scheduled events and the shutdown / reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by audible alarm, SMS or e-mail. Software supports Windows, Linux, Mac, Solaris, Open VMS and IBM operating systems. REMOTE LCD AND LED MIMIC PANEL Facilitates the monitoring and control of the UPS operations, events and parameters from a remote location. APPLICATION Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education www.dalepowersolutions.com 19

E Series UPS Secure Power E400 Series An Advanced UPS Technology 3:3 Phase 20 120kVA 0.8PF Intelligent ligent Slot options: RELAY CARD SNMP CARD FEATURES 3 High frequency double conversion on-line technology 3 Fully digitised microprocessor control 3 Parallel capacity or redundancy (maximum 4 units) 3 Wide input voltage range 3 Intelligent battery charge management 3 Automatic battery charge in UPS off mode 3 RS232 communication with monitoring software 3 Short circuit and overload protection 3 Lightning and surge protection 3 EMI and RFI noise filtering 3 Line interactive ECO mode 3 User friendly LCD interface 3 Cold start function 3 Fan speed auto control with load variation 3 Built-in maintenance bypass switch 3 Configurable external battery options 3 Emergency Power Off function 3 Relay alarm card fitted as standard 3 Optional SNMP network card available 20

The Dale E400 series UPS is an advanced, innovative range of high frequency, on-line double conversion Uninterruptible Power Supplies. Full DSP controlled inverter technology ensures continuous, clean, true sine wave power to critical applications under a wide range of conditions. Available in output power capacities from 20 to 120kVA, all with three phase input and output. The E400 series UPS is one of the finest secure power solutions available, capable of protecting a diverse range of critical load applications. COMMON SPECIFICATIONS Input Voltage Range 184V AC to 276V AC Line-Neutral Phase Frequency 3 Phase 4 Wire & Earth 40 to 70Hz Power Factor > 0.99 Output Voltage 220/230/240V AC Line-Neutral (user adjustable) Phase Frequency 3 Phase 4 Wire & Earth 50/60Hz (user adjustable) THD (Linear Mode) < 2% THD (Non-Linear Mode) < 5% Waveform Overload Capacity Crest Factor Sine wave 110%: 60 mins, 125%: 10 mins, 150%: 1 min 3:1 (max) Power Factor 0.8 Short Circuit Protection Transfer Time Battery External Configurable 32 / 34 / 36 / 38 / 40 12V mono blocks (384V / 408V / 432V / 456V / 480V DC Nominal) Environment Altitude 1000m at rated power (de-rate output by 1% per 100m above 1000m) max 4000m Operate Temperature 0 C to 40 C Storage Temperature Yes 0ms -25 C to +55 C Relative Humidity 95% Communication Standard: RS232 Optional: SNMP LCD Screen Display Operation mode LED Indication Noise Level Measurements: Input/output voltage/freq, battery voltage, load power and kva, UPS temperature Operation mode: On-line, Battery, Bypass Double conversion on-line or ECO line interactive (user selectable) Mimic panel overview of UPS operation and alarms < 62 dba Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1 & EN62040-2 Standard Accessories Control software, data lead & user manual MODEL SPECIFICATIONS Model Output Ratings Full Load Battery DC Audible Noise Physical Number (kva) (kw) Efficiency Voltage (dba) Nett Weight (kg) Dims (mm) (H W D) E420 20 16 92% 384 480V < 56 186 / 226 1200 600 730 E430 30 24 92% 384 480V < 56 192 / 232 1200 600 730 E440 40 32 92% 384 480V < 56 203 / 243 1200 600 730 E460 60 48 93% 384 480V < 56 280 / 328 1800 600 730 E480 80 64 93% 384 480V < 56 289 / 357 1800 600 730 E4100 100 80 90% 384 480V < 62 295 / 363 1800 600 730 E4120 120 96 90% 384 480V < 62 295 / 363 1800 600 730 Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. www.dalepowersolutions.com 21

E Series UPS Secure Power E400 Series + DSP Power Factor Corrected IGBT Rectifier Latest IGBT power factor correction technology provides an input power factor close to unity ( 0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads. Parallel and Redundant Operation Capability to connect up to 4 units in parallel to provide increased power capacity or redundancy. All parallel units can be operated from the front panel of the master UPS. Programmable master/slave rotation is provided for additional reliability. POWER INCREASE Units can be connected in parallel to increase the total capacity of the system. When an inverter goes offline, the critical loads are automatically transferred to bypass. REDUNDANCY Units can be connected in parallel to provide redundancy for absolute reliability. In parallel redundant mode, the number of units (N) supply the load and an extra unit is provided in case of failure (N+1). All units share the load current equally. When a unit goes offline, due to failure or maintenance, the standby unit continues to supply the critical load without any interruption. Back Feed Protection Back feed protection prevents current from the UPS output feeding back to the UPS input terminals, thereby protecting maintenance personnel from electrocution whilst working on the incoming supply side of the system. Advanced Battery Management Intelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. 3 Automatic adjustment of charging parameters based on the battery configuration entered via the LCD panel. 3 Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining). 3 Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load. The batteries can also be hotswapped without disconnection of the UPS. DSP Controlled IGBT Inverter The DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads. Static & Manual (Maintenance) Bypass Static and manual bypass switches are included as standard, with operational characteristics as follows: STATIC BYPASS This feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line. To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics. MANUAL BYPASS This feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load. Single or Dual Source Operation To increase flexibility, the UPS input can be fed by single or dual sources. In dual configuration, the rectifier is fed from the utility (main source) and the static and maintenance bypass are fed from a secondary source. Discrete UPS Module Design The UPS design incorporates discrete rack mount PFC and Inverter assemblies to facilitate quick and easy replacement for low Mean Time To Repair (MTTR). The UPS modules can be exchanged with the protected load supplied by the internal maintenance bypass breaker. Frequency Converter Mode The UPS can also be used as a frequency converter. It can accept a 40Hz to 70Hz input frequency range and provide a stable 50Hz or 60Hz output frequency. 22

Excellent Generator Compatibility Thanks to the robust IGBT rectifier, the E400 series UPS is compatible with a diverse range of sources, including generators. High Input power factor (0.99) and low input current total harmonic distortion (THDi) <3% is achieved without compromising efficiency, allowing a modestly sized generator to be utilised. Power walk-in can be adjusted from 5 to 20 seconds. Based on the current measured on the input, the UPS gradually increases the power supplied from the utility source to the load. Control Power Supply Board Redundancy The E400 series UPS is equipped with two identical and fully redundant control power supply boards. The boards are fed by both AC and DC sources within the UPS. If one of the sources or even one of the boards fails, the UPS system can continue to operate normally using the remaining source or control power supply board. This feature further enhances the reliability of the system. Lower Total Cost of Ownership The high efficiency operation of the UPS means that less energy is consumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements. With low <3% THDi and high 0.99 input power factor, switchgear, circuit protection, cabling and generator requirements are minimised, thus reducing investment cost. Advanced User Interface The UPS operating information, status and parameter settings are accessed using the large user friendly, data rich LCD and system LED mimic panel. The UPS stores 500 events on a rolling data log. Green ECO Mode of Operation The E400 series UPS can be operated in high efficiency ECO mode (97%) providing green energy savings through reduced power consumption. Emergency Power Off (EPO) The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging. With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened. Auto Re-start When the utility and bypass sources fail, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of Discharge threshold, the UPS will shut down. The UPS can be programmed to auto-recover after End of Discharge after a set variable delay time. Cold Start Operation When the utility and bypass sources are not available, the cold start feature enables the UPS to be started using the battery only. Advanced Communications A wide range of advanced communication options are available: RELAY ALARMS CARD Isolated, volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely. RS232 SERIAL PORT The UPS operating parameters can be observed and controlled locally using an RS232 communications port. SNMP NETWORK CARD Enables monitoring and control of the UPS operation by LAN or Internet connection. Allows the remote execution of scheduled events and the shutdown / reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by SMS or e-mail. Software supports Windows, Linux, Mac, Free BSD and VM Ware operating systems. Accepts environmental monitoring inputs (temperature, humidity, water, smoke, security sensors). REMOTE LCD PANEL Facilitates the monitoring and control of the UPS operations, events and parameters from a remote location. Load-Bus Synchronisation E400 series UPS may be configured to achieve Load Bus Synchronisation, whereby the outputs of two independent UPS systems (single or parallel units) are synchronised, enabling the load to be switched transparently between either source. APPLICATION Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education www.dalepowersolutions.com 23

E Series UPS Secure Power E600 Series An Advanced UPS Technology 1:1, 3:1, 3:3 Phase 4kVA 200kVA FEATURES 3 Flexible and expandable UPS power solution 3 19" cabinets available in full and half height format 3 Modular design capable of housing either 5 or 10 power modules 3 1:1 and 3:1 power modules available in 4, 6 and 10kVA ratings 3 3:3 power modules available in 10, 15 and 20kVA ratings 3 Configurable N+1 modular redundancy 3 Parallel system capability on 3:3 models (maximum 4x cabinets) 3 High frequency double conversion on-line technology 3 Wide input voltage range 3 Intelligent battery charge management 3 Programmable battery charge current 3 Short circuit and overload protection 3 EMI and RFI noise filtering 3 Smart RS232 communication with monitoring software 3 Fully digitised microprocessor control 3 Large touch screen LCD interface BATTERY PACK Intelligent Slot options: RELAY CARD SNMP 3 Built-in maintenance bypass 3 Emergency Power Off function 3 Optional SNMP card or relay card 3 Optional hot plug internal batteries on 1:1 and 3:1 models 24

The Dale E600 series UPS is a sophisticated, new generation of modular, high frequency on-line double conversion Uninterruptible Power Supplies. Full DSP controlled inverter technology ensures continuous, clean, true sine wave power to critical applications under a wide range of conditions. Available in output power capacities from 4 to 100kVA in 1:1 and 3:1 phase configurations and 10 to 200kVA in 3:3 phase configuration. The E600 series UPS is the perfect modular UPS solution, capable of supporting a diverse range of mission critical applications. SPECIFICATIONS Cabinet Model E61150 E611100 E63150 E631100 E633100 E633200 Maximum Rating 4-50kVA 4-100kVA 4-50kVA 4-100kVA 10-100kVA 10-200kVA 3.2 40kW 3.2 80kW 3.2 40kW 3.2 80kW 9 90kW 9 180kW Input Voltage range 120 to 276V AC Line - Neutral 208 to 478V AC Line - Line 208 to 478V AC Line - Line Phase 1 Phase 2 Wire & Earth 3 Phase 4 Wire & Earth 3 Phase 4 Wire & Earth Frequency 40 70Hz Power factor 0.99 Output Voltage 220 / 230V AC Line Neutral 220 / 230V AC Line Neutral 380 / 400 / 415V AC Line Line Phase 1 Phase 2 Wire & Earth 1 Phase 2 Wire & Earth 3 Phase 4 Wire & Earth Frequency range THD 50-60Hz 2% with linear load 5% with non-linear load Efficiency Normal mode 90% Overload capability Load 110% 60 min, 125% 10 min, 150% 1 min, 150% automatic shutdown of UPS Crest factor 3:1 Power factor 0.8 0.8 0.9 Short circuit protection Waveform Transfer time YES Sine wave 0ms (between on-line mode and battery mode) Battery DC voltage 16/18/20x 12V blocks 32/34/36/38/40x 12V blocks 192V/216V/240V DC 384V/408V/432V/456V/480V DC Charge current Recharge time 6A (per module) Depends on battery capacity and charger current Environment Temperature 0 40 C Communication Relative humidity 0 95% (non-condensing) Altitude <1500m RS232, RS485, SNMP (optional) relay card (optional) LCD Touch screen display Measurements: Input & output voltage/frequency, battery voltage, load power & kva, UPS temperature Operation mode: i.e. Online, On Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Battery mode/bypass mode Red LED: Abnormal operation Noise Level Safety & EMC CE EN/IEC 62040-2, EN/IEC62040-1-1 Weight & Dimensions Std. unit weight (empty) 150kg 213kg 150kg 213kg 170kg 230kg Dimensions (H W D) mm 1400x600x840 2000x600x840 1400x600x840 2000x600x840 1400x600x840 2000x600x840 Standard Accessories Control software No (unless SNMP option selected) Data lead No User manuals Yes Power Module E61104H E61106H E61110H E63104H E63106H E63110H E63310H E63315H E63320H Capacity 4kVA 6kVA 10kVA 4kVA 6kVA 10kVA 10kVA 15kVA 20kVA Weight & Dimensions Standard unit weight 21kg 23kg 25kg 21kg 23kg 25kg 26kg 30kg 31kg Dimensions (H W D) mm 131 443 580 (3U) Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions Ltd own data & is considered accurate at time of publishing. www.dalepowersolutions.com 25

E Series UPS Secure Power E600 Series + DSP Power Factor Corrected IGBT Rectifier Latest IGBT power factor correction technology provides an input power factor close to unity ( 0.99) and input current total harmonic distortion (THDi) less than 3% to avoid disturbances to the connected loads. N+X Parallel Modular Redundancy The E600 series provides N+X parallel modular redundancy for absolute reliability. When a module goes offline, due to failure or maintenance, the remaining modules continue to supply the load without any interruption. The level of redundancy can be set to suit the criticality of the protected load. Should the load increase above the redundancy threshold, the UPS will alarm to notify the user there is insufficient capacity available to maintain the load if a module fails. This allows preventative action to be taken (decrease load or install additional UPS modules). HIGH AVAILABILITY & MTBF All UPS modules share the load current equally. With two modules configured for redundancy, the UPS system achieves 99.999% availability and the Mean Time Before Failure (MTBF) exceeds 15,000,000 hours, satisfying the reliability requirements of the critical load. The UPS design incorporates drawer style hot-swap UPS modules to facilitate quick and easy replacement for low Mean Time To Repair (MTTR). DSP Controlled IGBT Inverter The DSP controlled IGBT inverter provides a clean, true sine wave output voltage to deliver the highest quality power to protect critical loads. Advanced Battery Management Intelligent precision charging principles guarantee enhanced battery life and maximum battery performance and reliability. This provides the reassurance that the battery is primed and ready for the critical role they play in your power protection system. 3 Powerful 6A charger built into each UPS module with the ability to freely set the charge current level. 3 Automatic adjustment of charging parameters based on the battery configuration settings. 3 Real-time battery management information is displayed on the LCD, such as battery capacity (as percentage or time remaining). 3 Programmable automatic or manual battery tests can be performed without interruption to the UPS operation or load. The batteries can also be hotswapped without disconnection of the UPS. Single or Dual Source Operation For increased flexibility, the E600 series UPS is available with a split bypass, enabling the UPS input to be fed by single or dual sources. In dual configuration, the rectifier is fed from the utility (main source) and the static and maintenance bypass are fed from a secondary source. Scalable Modular Solution 1.4m and 2.0m tall 19 cabinets are available, capable of holding up to 5 or 10 UPS modules respectively, providing scalability to expand as power demand increases. Up to 4 three phase cabinets may be connected in parallel configuration, providing a maximum output power capacity of 800kVA at 0.9 power factor. Static & Manual (Maintenance) Bypass Static and manual bypass switches are included as standard, with operational characteristics as follows: STATIC BYPASS This feature provides a safe transfer to mains should the UPS be overloaded or develop a fault condition. The static switch contains electronically controlled switching circuits that enable the critical load to be connected to either the inverter output or to a bypass source via the static bypass line. During normal operation, the load is connected to the inverter, but in the event of a UPS overload or inverter failure, the load is automatically transferred to the static bypass line. To provide a clean (no-break) load transfer between the inverter output and static bypass line, the static switch activates and connects the load to bypass. To achieve this, the inverter output and bypass are fully synchronised by the inverter control electronics. MANUAL BYPASS This feature is provided solely to allow maintenance work to be carried out on the UPS without interrupting the power to the load. The UPS can be powered down to enable technical personnel to replace parts. Full system replacement and repair of major components does however, necessitate shutdown of the load. Cold Start Operation When the utility and bypass sources are not available, the cold start feature enables the UPS to be started using the battery only. 26

Excellent Generator Compatibility Thanks to the robust IGBT rectifier, the E600 series UPS is compatible with a diverse range of sources, including generators. High Input power factor (0.99) and low input current total harmonic distortion (THDi) <3% is achieved without compromising efficiency, allowing a modestly sized generator to be utilised. Adjustable power walk-in allows the UPS to gradually increase the power supplied from the utility source to the load, based on the current measured on the input. Wide Choice of Module Options 3U high drawer-style UPS modules with individual LCD control panel. Available in the following phase and power configurations: 3 1:1 Phase 4, 6 and 10kVA 3 3:1 Phase 4, 6 and 10kVA 3 3:3 Phase 10, 15 and 20kVA Common module size: H131 W443 D580mm Decentralised Parallel Structure Concept Each UPS module contains all the required hardware and software for autonomous operation, without reliance on the centralised monitoring module. This increases system reliability by eliminating Single Points of Failure (SPOF). Lower Total Cost of Ownership The high efficiency operation of the UPS ( 98% in ECO mode and 95% in On-Line mode) means that less energy is consumed to supply power to the protected loads. As a result of reduced heat emission and power loss, users benefit from reduced electricity usage and air conditioning requirements. With low <3% THDi and high 0.99 input power factor, switchgear, circuit protection, cabling and generator requirements are minimised, thus reducing investment cost. Advanced User Interface The UPS operating information, status and parameter settings are accessed using the large user friendly, data rich LCD and system LED mimic panel. The UPS stores 500 events on a rolling data log. Emergency Power Off (EPO) The EPO function is designed to switch off the UPS in an emergency situation (eg. fire, flood). Operation of the EPO turns off the rectifier and inverter and cuts power to the load immediately (both the inverter and bypass lines). The EPO also prevents the battery from charging or discharging. With the utility input supply present, the UPS control circuits remain energised, even though the output is turned off. To remove all power from the UPS, the external feeder breaker must be opened. Auto Re-start When the utility and bypass sources fail, the UPS draws power from the battery system to supply the load, until the batteries are depleted. Once the batteries reach their End of Discharge threshold, the UPS will shut down. Once the utility and bypass sources are re-instated, the UPS will auto re-start, deliver power to the load and recharge the battery. Advanced Communications A wide range of advanced communication options are available: RELAY ALARMS CARD Isolated, volt-free dry contacts indicate the UPS operating status and the presence of alarm conditions. Opto-isolated inputs allow the UPS to be controlled remotely. RS232 SERIAL PORT The UPS operating parameters can be observed and controlled locally using an RS232 communications port. SNMP NETWORK CARD Enables monitoring and control of the UPS operation by LAN or Internet connection and allows the remote execution of scheduled events and the shutdown/ reboot of the UPS and multiple servers. Full event log and data management. Real time notification of changes in UPS status reported to users by SMS or e-mail. Software supports Windows, Linux, Mac, Free BSD and VM Ware operating systems. Accepts environmental monitoring inputs (temperature, humidity, water, smoke, security sensors). Green ECO Mode of Operation The E600 series UPS can be operated in high efficiency ECO mode (98%) providing green energy savings through reduced power consumption. Centralised Monitoring Module All system data is processed by a centralised monitoring module offering advanced DSP control technology. The module itself can be exchanged from the system without disrupting the protected load. APPLICATION Server, Telecommunications, Networking, Data Centre, IT, Financial, Emergency Services, Defence, Retail, Transportation, Broadcasting and Communications, Healthcare, Leisure and Sport, Government, Education www.dalepowersolutions.com 27

E Series UPS Secure Power The Total Secure Power Solution Dale offers you 77 years of technical excellence in providing technologically advanced product solutions, expertly project managed and supported by tailored service packages. UPS and generator together true no break solution Our total secure power solution integrates UPS and generator together where the UPS supports critical loads without interruption until the generator kicks in. With our no-break power solution we can ensure your business continuity without costly downtime. 28

UPS Service and Support We provide nationwide service and maintenance contracts for all our UPS products and have a variety of preventive maintenance agreements that are designed to suit your system s needs. Wherever your equipment is required or located from the roof to the basement, in the desert or off shore we have the expertise to provide the perfect installation, service and maintenance solution. Planned preventative maintenance Scheduled inspections agreed to your requirements Database management We can manage all your equipment to ensure it is maintained to schedule Lifecycle management Optimising the operational cost and reducing capital outlay by upgrading or refurbishing both our own brand and other OEM equipment keeping it running longer Waste disposal Providing environmentally ethical and compliant disposal and recycling services Our Service portfolio includes: 3 Standard and bespoke maintenance/ service contracts 3 Standard and bespoke service contracts 3 System upgrades and modifications 3 DC load bank hire 3 Temporary battery and secure power system hire 3 Management of turnkey projects 3 Individually tailored training (in factory or on site) 3 Site surveys 3 Installation and commissioning 3 Independent advice on all aspects of standby power and batteries Our highly-skilled and qualified engineers have offshore certification, enabling us to work on oil and gas platforms as well as terrestrial installations world-wide. We offer a 24 hour, 365 days per year call out facility that is second to none. Your first point of contact will be with a member of our own Service team, not a call centre. This guarantees you a customised service and an immediate reaction facilitated by our nationwide team of engineers. www.dalepowersolutions.com 29

E Series UPS Secure Power Dale Power Solutions Corporate & Social Responsibility Operating in a responsible and sustainable manner is important to Dale Power Solutions. Whilst we run our business in line with the expectations of our stakeholders, we also see corporate responsibility as a discipline that helps us to manage risks and maximise on the opportunities presented to us in a changing world. We take our corporate responsibility seriously across the Company as an employer, manufacturer, investor and a consumer. We are committed to understanding, monitoring and managing our social, environmental and economic impact to enable us to contribute to society s wider goal of sustainable development. We aim to demonstrate these responsibilities through our actions and within our corporate policies. Environment We recognise the importance of understanding the impact of our activities on the environment and we are developing an Environmental Programme to demonstrate and benchmark our commitment. Our company is accredited to ISO 14001 and we are continually looking at ways to improve our efficiency across our sites. We promote energy and water efficiency, waste reduction, and reduction of potentially dangerous, volatile or environmentally damaging chemicals. We also have an ongoing commitment to reducing our carbon footprint. Health & Safety We shall provide, and strive to maintain, a clean, healthy and safe working environment. Providing a workplace where our employees feel safe is not only a legal obligation, but a fundamental factor in building their engagement with the company. Through management intervention, awareness campaigns and a culture that encourages employees to raise concerns about the workplace safety, we aim to reduce the frequency of accidents. Our SHE Team promotes and develops cooperation between all employees to ensure health and safety management is embedded into management and business processes. This is supported by our Health & Safety Policy. Community We are committed to making a sustainable positive impact on the communities in which we operate. We aim to make a distinctive contribution to equality and social development through the establishment of effective partnerships and programmes that make best use of the energies and skills of our employees. We support our employees in fundraising for charities and voluntary work, recognising both the benefit to the community and to the employees themselves. 30

The E Series UPS Secure Power Solution D A L E U P S Dependable and reliable Advanced power solutions Leading edge technology Ethical and environmentally friendly Unrivalled installation and support Precision power management Secured business continuity Setting New Standards The Dale brand provides the benchmark in UPS power solutions for diverse global markets including: 3 Data Centres 3 Financial 3 Commercial 3 Retail 3 Medical An unmatched history of continued supply of secure power solutions for the most demanding requirements worldwide, providing total customer satisfaction. www.dalepowersolutions.com 31

E Series UPS Secure Power Dale Power Solutions Delivering secure back-up power across the globe Established since 1935, Dale Power Solutions has become a global leader in bringing technology and engineering together to create innovative solutions, protecting critical power supplies for customers through our standby power systems. With an annual turnover in excess of 30million, it is through Dale Power Solutions commitment to excellence, combined with our mission to deliver outstanding client service has earned Dale Power Solutions its prestigious reputation it enjoys today as one of the world s most trusted providers of standby power solutions. Dale Power Solutions provides a comprehensive and bespoke design capability service to our customers, taking initial concepts through design, project management, manufacturing, installation and commissioning processes, followed by complete maintenance and servicing on a worldwide basis to more than 8,000 generators and UPS systems. Our professional structure, financial strength and the necessary quality assurance, health and safety, and product accreditations meet the demands of the world s most discerning clients. These accreditations include: Proud of our pedigree proud to be your partner. 32

Dale E Series UPS Secure Power Business power continuity guaranteed www.dalepowersolutions.com

produced by adverset media solutions limited www.adverset.co.uk Dale Power Solutions Ltd HEAD OFFICE, FACTORY 1, SCARBOROUGH Salter Road Eastfield Industrial Estate Scarborough North Yorkshire YO11 3DU Tel : + 44 01723 583511 FACTORY 2, FILEY ABERDEEN BRANCH LONDON CITY BRANCH Tel : + 44 01723 583511 Tel: + 44 01224 270 391 Tel: + 44 020 3217 3041 MIDDLE EAST BRANCH Tel: +971 4 364 1228 Your power in safe hands www.dalepowersolutions.com