SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Similar documents
SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Master DIALOG INDUSTRY RANGE

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

SR series. on-line

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master Plus kva

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

SIRIUS Online UPS. data CeNTReS. TeleCoMMUNICATIoN devices. MedICAl devices. emergency devices. TRANSPoRTATIoN. Smart Energy Solutions

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Master MPS kva kva 3:1 3:3 VFI TYPE

Master Plus kva

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

HAIRF UPS. X5 Series KVA

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical data sheets

POWER kva

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

POWER kva

Technical Data Sheets

EFFEKTA Power Supplies

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TECHNICAL DATA SHEET KVA UPS Systemss

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

PowerValue 11/31 T kva

Technical Data Sheets

ConceptpowerTM Modular kVA

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Industrial PFC UPS System

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Technical Data Sheets

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheets

UPS Multi Sentry 10-20kVA

TECHNICAL SPECIFICATIONS

YOUR POWER IN SAFE HANDS. E Series UPS

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

D Series: UPS UPTO - 300KVA - Three / Three Phase

» Sophisticated» Reliable» Intelligent

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

POWERTRONIX QUASAR 5-40 KVA

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

PowerPro three phase UPS technical data

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Liebert. FP 50Z kva

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

Aurora Single Phase Emergency Lighting Inverters

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

TLE Series UPS 400/500 kw With eboost Technology

60 to 160 kva.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

» Eco-Friendly. » Intelligent» Space Saving

Technical Data Sheets

Three Phase UPS Systems Range: 10 to 500kVA

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 160/200/225/250 kw with eboost Technology

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

PowerScale TECHNICAL SPECIFICATIONS

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Phase Modular Finally the benefits of Modular ups are for all

S2000 PRODUCT RANGE. Ultra compact

Illuminator Series CR NEMA 3R

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

SENTINEL VA

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS Multi Power 1-28 x 42 kw up to 1MW

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerScale kva Technical Specifications

MGE TM Galaxy TM 7000 GFC

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

Synthesis Twin. from 6 to 20 kva

TLE Series UPS 750/1000 kw With eboost Technology

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Transcription:

SUPREME 10-20 kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME on-line UPS The series includes the 10-15-20kVA three/single-phase, 10-15-20-30-40-60-80kVA three- phase models and uses double conversion on-line technology (VFI) with an in-built isolation transformer on the inverter output. The load is powered continuously by the inverter with a filtered, stabilised and regulated sinewave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges. provides maximum protection for vital 'mission- critical' networks, security applications (electromedical) and industrial applications thanks to its outstanding mechanical and electrical design. is supplied with UPS Network Monitoring 3 software as standard and can be remotely monitored using the Teleguard system from anywhere in the world. Additional battery extension packs allow the standard battery runtime to be extended up to several hours. Rectifier Bypass SUPREME UPS is equipped with BATTERY PROTECTION. There are several features that help to prolong battery life span and performance, such as: - cycling charging - two voltage level charging - temperature compensation charging - protection against deep discharge - battery self test - compatibility with open vented acid battery Inverter Inverter output isolation transformer Static by-pass Manual by-pass

Simplified Maintenance Access for maintenance is entirely from the front of the UPS. With the door opened and the protective panel removed, the power components mounted on the sliding tray can be pulled out to provide easy access to all the electrical and electronic components for maintenance and repair work. This particular feature means that the MTTR (Mean Time To Repair) is typically less than 30 minutes. A large amount of maintenance information is available from the front large LCD mimic panel. In addition system operating parameters are software configurable via a local PC to allow new functions to be added or adjustments made to operating specifications. Display Control Panel Bypass line indicator line indicator discharging Load on mains Load on inverter Alarm 1. Language selection 2. Input/output measurements 3. Controls/settings/customisations 4. Event log 5. Buzzer reset 6. Time/date 7. Scroll back 8. Scroll forward Main Features Large LCD screen with graphic display and improved high output power factor at 0.9 Can configure as Frequency Converter 50Hz to 60Hz or vice versa Reliable, filtered, stabilised and regulated sinewave output (double conversion on-line technology VFI according to EN50091-3 specifications) with filters for atmospheric disturbance suppression High reliability: IGBT technology, full microprocessor control with no-break static and manual bypasses, extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output Maximum reliability and power availability - connect up to 8 units in parallel or N+1 redundancy, even of different power ratings (optional) Low input total harmonic distortion (<5%) (optional) High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD in several languages Low loss high efficiency up to 98% in ECO-Mode for all models Simple to install: - Capability to install the UPS into any distribution system (neutral not required on rectifier input) - Capability to separate the rectifier/bypass power networks and of powering these from two separate sources, without galvanic isolation (necessary on those UPS without an output transformer) Capability of regulating the output voltage (to offset voltage drops down long cable runs) Built-in automatic and manual battery test feature, battery deep discharge protection and temperature compensating charger BACK FEED protection: to avoid energy feeding back into the mains supply should a fault occur.

SUPREME Technical Specification Three Phase Model 10 (3/3) 15 (3/3) 20 (3/3) 30 (3/3) 40 (3/3) 60 (3/3) 80 (3/3) Rated power (kva) 10 15 20 30 40 60 80 INPUT 400 Vac three-phase Voltage range +20%, -25% Rated frequency Frequency range 50/60 Auto sensing 45Hz to 65Hz Power factor >0.9 Permitted voltage range Rated frequency Permitted frequency range Standard features Type Maximum recharge current (A) Maintenance voltage BY PASS 400 Vac three-phase (380V, 415V selectable) ±15% (selectable from ±10% to ± 25% from front panel) 50/60 Auto sensing ± 2% (selectable from ±1% to ±6% from front panel) Backfeed protection; separate bypass line BATTERIES Maintenance-free sealed lead-acid 0.2xC10 RECTIFIER OUTPUT Variable acc. to temperature (-0.5 Vx C) Ripple <1% INVERTER OUTPUT Rated power (kva) 10 15 20 30 40 60 80 Rate (kw) 9 13.5 18 27 36 54 72 Number of phases Regulation of output voltage 3 phase + N 380/400/415 selectable 360V to 420V 3 phase Crest factor (Ipeak/Irms) 3: 1 Waveform Sinewave Static stability ± 1% Dynamic stability & recovery ±5% in 20ms according to EN 62040-3 Class 1 Frequency Overload Frequency stability Remote signalling Remote controls 50Hz to 60Hz selectable 110% for 60 mins; 125% for 10 mins; 150% for 60 secs ±0.05% with mains supply failure ENVIRONMENTAL Volt free contacts; UPS SNMP Network Management; ModBus/J-Bus Converter; Profibus Converter EPO and bypass Operating temperature 0 C - 40 C Relative humidity < 95% (non condensing) Colour Light Grey RAL 7035 Noise@1m, 0 to full load (dba) 60 62 Protection rating Efficiency IP20 Up to 98% in stand-by mode Weight (kg) 210 220 230 282 330 450 555 Dimensions (mm) (LxDxH), 6 pulse 555x740x1400 800x740x1400 Back-up (min) Internal from 0 to 30 from 0 to 15 from 0 to 10 0 0 0 0 Option: CLEAN VERSION for 5% THDi, Remote Monitor Panel, 12 pulse Rectifier*, Communication Software & Accessories, Isolation transformer, Parallelable 8 units.* For the following models: 60 (3/3) & 80 (3/3) Note: UPS Specification and data subject to change for improvement without prior notice.

SUPREME Technical Specification Three/Single Phase Model 10 (3/1) 15 (3/1) 20 (3/1) INPUT Rated power (kva) 10 15 20 400 Vac three-phase (380V to 415V configurable) Voltage range +20%, -25% Frequency range 45Hz to 65Hz Power factor 0.9 BY PASS Rated Current (A) 43 65 87 Permitted voltage range Rated frequency Permitted frequency range Standard features Type Maximum recharge current (A) Maintenance voltage 230 Vac single-phase (220V or 240V configurable) ±15% (selectable from ±10% to ± 25% from front panel) 50/60 Auto sensing ± 2% (selectable from ±1% to ±6% from front panel) Backfeed protection; separate bypass line BATTERIES Maintenance-free sealed lead-acid 0.2xC10 RECTIFIER OUTPUT Variable acc. to temperature (-0.5 Vx C) Ripple <1% INVERTER OUTPUT Rated power (kva) 10 15 20 Rate (kw) 9 13.5 18 Number of phases Single-phase 220/230/240 Regulation of output voltage 210V to 242V phase/neutral (from control panel) ±15% Crest factor (Ipeak/Irms) 3: 1 Waveform Sinewave Static stability ± 1% Dynamic stability & recovery ±5% in 20ms according to EN 62040-3 Class 1 Frequency Overload Frequency stability Remote signalling Remote controls Same as the input (autorange) 110% for 60 mins; 125% for 10 mins; 150% for 60 secs ±0.05% with mains supply failure ENVIRONMENTAL Volt free contacts; UPS SNMP Network Management; ModBus/J-Bus Converter; Profibus Converter EPO and bypass Operating temperature 0 C - 40 C Relative humidity < 95% (non condensing) Colour Light Grey RAL 7035 Noise@1m, 0 to full load (dba) 60 62 Protection rating Efficiency IP20 Up to 98% in stand-by mode Weight (kg) 200 220 230 Dimensions (mm) (LxDxH), 6 pulse 555x740x1400 Back-up (min) Internal from 0 to 30 from 0 to 15 from 0 to 10 Option: CLEAN VERSION for 5% THDi, Remote Monitor Panel, Communication Software & Accessories, Isolation transformer, Parallelable 8 units. Note: UPS Specification and data subject to change for improvement without prior notice. UPS three phase/single phase series. The input cables and protection must be capable of supplying the fully rated single phase output load should UPS switches to bypass mode.

G-TEC Service Center TECHNICAL ASSISTANCE SERVICES UPService, our technical assistance facility uses highly trained engineers to provide a reliable and competent technical support and after-sales service. UPService can provide customers with: A dedicated CALL CENTRE for connection to the UPService organisation. UPService personnel are always available and ready to provide advice and assistance regarding UPS installation, maintenance, fault finding and repair. FAST & READY A fast repair on site is guaranteed through the use of state-of-the-art UPS technology and the professionalism of the UPService personnel and Authorised Assistance Centres. UPService guarantees that failed parts are replaced with original ones, tested and updated in order to maintain the safety, reliability and operating characteristics of the UPS. COMMISSIONING AND START-UP UPService can provide assistance during commissioning and startup of the UPS equipment on-site with additional training during handover to site personnel. UPService engineers can also verify site suitability, analyse and advise on potential problems, and disconnect and relocate equipment. UPService recommend that all hardwired installations are commissioned by UPService engineers. MAINTENANCE CONTRACTS can be provided by UPService to minimise response times and repair costs. Contracts range from periodic inspections to comprehensive cover including labour and materials. The TELEGUARD software package provides remote 24 x 7 UPS supervision. TeleGuard can interrogate G-TEC UPS connected to a local telephone line to check on their operating logs and system status. Should the UPS report an alarm condition, the UPService Call Centre is immediately notified and a dedicated customer response activated. Routine site reports can be sent automatically to customer personnel. UPService organises regular TECHNICAL TRAINING COURSES for UPS operators and installers. Communication and Power Management Solutions ADVANCED COMMUNICATION Compatible with TELEGUARD for remote maintenance Advanced, multi-platform communication, for all operating systems and network environments: PowerShield 3 supervision and shut-down software included, with SNMP agent, for Windows NT 4.0, XP, Vista, Mac OS 10.x, Linux, Novell operating systems. The FC is equipped with a cable for direct connection to the PC (Plug and Play) *Can also provide shut-down software for: IBM AIX; Free BSD; BSDI UNIX; BSD/OS; SCO Unixware; SCO Openserver; Sun Solaris; Compaq True64;HP UNIX; HP OpenVMS; HP Openview; SGI Irix MIPS; NCR UNIX Double RS232 serial port Network adapter slot for SNMP agent EPO (Emergency Power Off) shut down input contact Remote control panel (optional) *All the trademarks indicated are the property of their respective owners. DETAILED UPS PARAMETER DISPLAY Powershield 3 provides all the information required for first level diagnostics. BLOCK AND FUNCTIONAL DIAGRAMS Powershield 3 also displays the UPS in block format providing the user with information regarding the operating status.

Flexible Configuration Bypass mains UPS1 UPS2 UPS3..8 UPS Redundancy: Parallel Bypass 1 Bypass 1 Load Parallel up to 8 UPS UPS1A System A Bypass 1 UPS2A UGS Synchroniser STS UPS1B System B Bypass 1 UPS2B Distribution Redundancy: UGS UPS Group Synchroniser (UGS) ensures 2 or more UPS parallel groups remain synchronised even during a mains supply failure. The UGS also enables to be synchronised with an independent power source and even with different rating. Load 3 Load 1 STS Load 2 Load 4 System A System B UPS1A UPS2A PSJ UPS1B UPS2B Distribution Redundancy: PSJ The Parallel Systems Joiner (PSJ) enables the connection of two UPS groups operating in parallel configuration through a power coupling switch. The Slave Group is permanently synchronised to the Master Group. Should one of the UPS in one of the parallel groups fail, the PSJ will automatically connect the remaining UPS to the other group. Load 1 Load 2