CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Similar documents
CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

PC-125x Counter-Balanced Backdraft Damper

ARROW INDUSTRIAL PRODUCTS

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

VCD-23. Flange Options. Size Limitations

VCD-23. Low Leakage CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

VCD-23 Low Leakage CONTROL DAMPER

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20 3V CONTROL DAMPER

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

LINEAR DIFFUSERS AND BAR GRILLES

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

ARROW UNITED INDUSTRIES

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model VCD-43 Extruded Airfoil Blade Control Damper

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

ID-141x 12-Gauge Hat Channel Industrial Damper

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

HCD-230 Industrial Control Damper

Series HCD Airfoil Control Damper

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

BD-1600 Balancing/Zone Control Damper

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Thermal Isolation. Break

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AIR CONDITIONING PRODUCTS COMPANY

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

ACCESS DOORS GENERAL PRODUCT OVERVIEW

Model FSD-331 Combination Fire Smoke Dampers

Introduction to Johnson Controls Dampers

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

SECTION CONTROL DAMPERS

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

FSD60/MFSD60 Multi-blade Fire Damper

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

For installation into ductwork

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

MOTORIZED VOLUME DAMPER

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

LINEAR DIFFUSERS AND BAR GRILLES

GRAVITY VENTILATORS SIZING

MULTI-BLADE FIRE DAMPERS

GRAVITY VENTILATORS SIZING

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

RM-1200 Slim Round Control Damper

SECTION DUCTWORK ACCESSORIES

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

AD-1250 Airflow Measuring Station

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

DAMPERS WE CONTROL AIR

Filtered Kitchen Supply Packaged Ventilator

ceiling & inline/cabinet ventilators

HVAC Control & Balancing Dampers

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

Motorized Fire Dampers

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

EGG CRATE RETURN GRILLE

L O U V E R S & D A M P E R S

CEILING & INLINE/CABINET VENTILATORS

Installation, Operation, and Maintenance Instructions

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

Transcription:

CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and velocity commercial HVAC systems. Ruggedly built, they provide a cost effective and reliable damper for reduced volume control and offer an economical manufactured product alternative to custom 'shop built' dampers that exceed the volume damper designs recommended by SMACNA. Features include a sturdy galvanized steel hat channel frame with die-formed corner gussets for reinforcement and superior structural strength, a vee groove blade design that maximizes strength and optimizes airflow and no-maintenance concealed linkage located out of the airstream, totally enclosed within the damper frame for reduced air turbulence, noise and pressure drop. Models 1810 & 1820 MODEL 1870 MANUAL ALANCING DAMPER STEEL SINGLE LADE Model 1870 Manual alancing Damper is a ruggedly built, economical branch duct balancing damper designed for manual balancing applications with rectangular ductwork. The 1870 installs quickly and easily, saving time and money on installation costs. The low profile 18 ga. (1.3) frame and sills allow maximum free area and the ribbed forms in the blade and frame provides extra strength. A locking manual hand quadrant is provided with each damper. Model 1870 MODEL 1890 MANUAL ALANCING DAMPER ROUND DUCT Model 1890 Manual alancing Damper is a steel butterfly damper designed for all types of round ductwork balancing applications and is suitable for use in low pressure and velocity commercial HVAC systems. The design features a sturdy beaded casing ideal for round spiral ductwork connections, and a corrosion resistant steel blade that can be locked in any position with the hand quadrant that is supplied as standard with the damper. The 1890 installs quickly and easily and becomes part of the ductwork, saving time and money on installation costs and is an economical alternative to a shop built damper. Model 1890 6 Model 1370 MODEL 1370 ACKDRAFT DAMPER EXTRUDED ALUMINUM LIGHT/ MEDIUM DUTY Model 1370 is an extruded aluminum gravity operated backdraft damper for use in light to medium duty commercial HVAC applications to pass airflow in one direction and to prevent airflow in the opposite direction. Standard features include a corrosion resistant extruded aluminum reinforced mitered corner frame that resists racking, aerodynamic extruded aluminum blades that overlap the jambs for maximum weather protection, extruded PVC blade seals that provide quiet closure as well as extra weather protection, corrosion resistant long life synthetic bearings and a concealed blade linkage for low pressure drop that provides smooth operation at system velocities of up to 1500 fpm (7.6 m/s).

CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy duty commercial and light industrial HVAC applications to pass airflow in one direction and to prevent airflow in the opposite direction. Corrosion resistant extruded aluminum construction highlights the model s features which include a heavy duty frame with reinforced mitered corners that resist racking, aerodynamic blades that overlap the jambs for maximum weather protection, extruded PVC blade seals that provide quiet closure as well as extra weather protection, corrosion resistant long life synthetic bearings and a concealed blade linkage for low pressure drop that provides smooth operation at system velocities of up to 2500 fpm (12.7 m/s). Model 1370C Model 1380 MODEL 1370C COUNTERALANCED ACKDRAFT DAMPER EXTRUDED ALUMINUM LIGHT/ MEDIUM DUTY Model 1370C Counterbalanced ackdraft Damper is designed to automatically prevent the backflow of air while allowing for automatic air intake or exhaust/pressure relief in medium duty HVAC applications. Standard features include a corrosion resistant extruded aluminum reinforced mitered corner frame that resists racking, aerodynamic extruded aluminum blades that overlap the jambs for maximum weather protection, extruded PVC blade seals that provide quiet closure as well as extra weather protection, corrosion resistant long life synthetic bearings and a concealed blade linkage for low pressure drop that provides smooth operation at system velocities of up to 1500 fpm (7.6 m/s). lade mounted counterweights are easily adjusted to desired opening pressure. CONTROL DAMPERS MODEL 1380C HIGH PERFORMANCE COUNTERALANCED ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380C High Performance Counterbalanced ackdraft Damper is engineered and designed to automatically prevent the backflow of air while allowing for automatic air intake or exhaust/pressure relief in medium to heavy duty commercial and light duty industrial HVAC applications. Corrosion resistant extruded aluminum construction highlights the model s features which include a heavy duty frame with reinforced mitered corners that resist racking, aerodynamic blades that overlap the jambs for maximum weather protection, extruded PVC blade seals that provide quiet closure as well as extra weather protection, corrosion resistant long life synthetic bearings and an out of sight rear mounted blade linkage for that provides smooth operation at system velocities of up to 2500 fpm (12.7 m/s). lade mounted counterweights are easily adjusted to desired opening pressure. Model 1380C MODEL 1390C HIGH PERFORMANCE COUNTERALANCED ACKDRAFT DAMPER STEEL FRAME HEAVY DUTY Model 1390C is a counterbalanced backdraft damper designed for pressure relief to automatically assist in maintaining and limiting desired pressures in medium to heavy duty commercial and light duty industrial HVAC or process air systems. The unique extruded aluminum blade design and fully adjustable counterbalance assembly offer pressure relief at extremely low pressure differentials. The rugged steel mitered corner frame is reinforced to resist racking, and ball bearings provide extreme sensitivity and ultra-smooth operation. Neoprene blade seals provide quiet closure as well as extra weather protection. Model 1390C 7

ACKDRAFT DAMPERS LIGHT/MEDIUM DUTY ACKDRAFT DAMPER EXTRUDED ALUMINUM GRAVITY OPERATED LIGHT/ MEDIUM DUTY Model: 1370 ackdraft Damper ACKDRAFT DAMPERS Model 1370 Model 1370 is an extruded aluminum gravity operated backdraft damper for use in light to medium duty commercial HVAC applications to pass airflow in one direction and to prevent airflow in the opposite direction, suitable for use in fan discharge applications. Standard features include a corrosion resistant extruded aluminum reinforced mitered corner frame that resists racking, aerodynamic extruded aluminum blades that overlap the jambs for maximum weather protection, extruded PVC blade seals that provide quiet closure as well as extra weather protection, corrosion resistant long life synthetic bearings and a concealed blade linkage for low pressure drop that provides smooth operation at system velocities of up to 1500 fpm (7.6 m/s). A variety of frames and screens are available for specific application requirements. STANDARD CONSTRUCTION: Frame: 2" (51) wide x.090" (2.3) nominal wall thickness type 6063-T5 extruded aluminum. Corners are mitered. lades:.050" (1.3) nominal wall thickness type 6063-T5 extruded aluminum on 3 5/8" (92) centers. Linkage: earings: lade Seals: Finish: Concealed in jamb. Synthetic type. Extruded PVC. Mill. Model 1370 Sizes (Duct W x H): Minimum Maximum Single Section Single Section Multiple Section 6" x 6" (152 x 152) 40" x 48" (1016 x 1219) Unlimited H = DUCT SIZE - 1/4" (6) 1370 Series - Maximum Performance Ratings Maximum System Velocity Maximum Spot Velocity Maximum ack Pressure Maximum Temperature 1500 fpm (7.6 m/s) 2500 fpm (12.7 m/s) 6 in. w.g. (1.5 kpa) 200 F (93 C) W = DUCT SIZE - 1/4" (6) MODEL 1370 2" (51) COMMON OPTIONS: Vertical or Horizontal mount. Front or rear flange frame (with or without bolt holes). Rear mounted bird and insect screens. 52

ACKDRAFT DAMPERS LIGHT/MEDIUM DUTY FRAME OPTIONS: MOUNTING OPTION: 5 1/4" (133) MAX. 1 1/2" (38) 1 1/2" (38) Channel Frame (Duct Mount) (Standard CF) Front Flange (on discharge side) (Option FF) Rear Flange (on intake side) (Option FR) Horizontal Mount Airflow up only (Option HMU) (Available on all frame styles) ACKDRAFT DAMPERS PERFORMANCE DATA: MODEL: 1370 Operational Data Leakage* Maximum Maximum Damper ack System lades lades % of Cfm Width egin Fully Maximum per Pressure Velocity Opening Open Flow Sq. Ft. 40" (1016) 3.0" w.g. 1500 fpm 1.00 15 36" (914) 4.0" w.g. 1500 fpm.05" w.g..20" w.g. 1.00 15 24" (610) 5.0" w.g. 1500 fpm (12 Pa) (50 Pa) 1.20 18 12" (305) 6.0" w.g. 1500 fpm 2.67 40 Pressure and velocity limitations shown are guidelines for design purposes. Although ratings are on the conservative side, contact Nailor for requirements beyond limitations shown. *Leakage data is based upon a pressure differential of 1 in. w.g., tested in accordance with AMCA Standard 500-D. PRESSURE DROP: Static Pressure Drop in inches w.g. (Pa) 1.0 (250.0).8 (200.0).6 (150.0).5 (125.0).4 (100.0).3 (75.0).2 (50.0).1 (25.0).08 (20.0).06 (15.0).05 (12.5).04 (10.0).03 (7.5).02 (5.0).01 (2.5) 10 (.05) 20 (.10) 30 (.15) 50 (.25) SIZE: 36" x 36" (914 x 914) 70 (.36) 100 (.51) 200 (1.02) 300 (1.5) 500 (2.54) Air Velocity in feet per minute (m/s) 700 (3.56) 1000 (5.08) 2000 (10.16) 3000 (15.24) Tested per AMCA Standard 500-D, Figure 5.5. 53

ACKDRAFT DAMPERS HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM GRAVITY OPERATED HEAVY DUTY Model: 1380 ackdraft Damper ACKDRAFT DAMPERS Model 1380 Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy duty commercial and light duty industrial HVAC applications to pass airflow in one direction and to prevent airflow in the opposite direction, suitable for use in fan discharge applications. Standard features include a heavy duty corrosion resistant extruded aluminum reinforced mitered corner frame that resists racking, aerodynamic extruded aluminum blades that maximize airflow and overlap the jambs for maximum weather protection, extruded PVC blade seals that provide quiet closure as well as extra weather protection, corrosion resistant long life synthetic bearings and a rear mounted blade linkage that provides smooth operation at system velocities of up to 2500 fpm (12.7 m/s). STANDARD CONSTRUCTION: Frame: 2 1/4" (57) duct mount type,.125" (3.2) nominal wall thickness type 6063-T5 extruded aluminum. Corners are mitered. lades: Linkage: earings: lade Seals: Finish:.070" (1.8) nominal wall thickness type 6063-T5 extruded aluminum on 5 1/2" (140) centers. Center mounted on rear of blades. Synthetic type. Extruded PVC. Mill. Model 1380 Sizes (Duct W x H): Minimum Maximum Single Section Single Section Multiple Section 6" x 6" (152 x 152) 40" x 52" (1016 x 1321) Unlimited H = DUCT SIZE - 1/4" (6) 1380 Series - Maximum Performance Ratings Maximum System Velocity Maximum Spot Velocity Maximum ack Pressure Maximum Temperature 2500 fpm (12.7 m/s) 3500 fpm (17.8 m/s) 16 in. w.g. (4 kpa) 200 F (93 C) COMMON OPTIONS: Vertical or Horizontal mount. Front or rear flange frame (with or without bolt holes). Rear mounted bird and insect screens. W = DUCT SIZE - 1/4" (6) MODEL 1380 (VM Vertical Mount standard) 2 1/4" (57) 54

ACKDRAFT DAMPERS HIGH PERFORMANCE FRAME OPTIONS: MOUNTING OPTION: 6 3/4" (171) MAX. 1 1/4" (32) 1 1/4" (32) Channel Frame (Duct Mount) (Standard CF) PERFORMANCE DATA: MODEL: 1380 Front Flange (on discharge side) (Option FF) Rear Flange (on intake side) (Option FR) Horizontal Mount Airflow up only (Option HMU) (Available on all frame styles) ACKDRAFT DAMPERS Operational Data Leakage* Maximum Maximum Damper ack System lades lades % of Cfm Width egin Fully Maximum per Pressure Velocity Opening Open Flow Sq. Ft. 48" (1219) 4.0" w.g. 2500 fpm 0.60 15 36" (914) 8.0" w.g. 2500 fpm.08" w.g..30" w.g. 0.60 15 24" (610) 12.0" w.g. 2500 fpm (20 Pa) (75 Pa) 0.72 18 12" (305) 16.0" w.g. 2500 fpm 1.00 25 Pressure and velocity limitations shown are guidelines for design purposes. Although ratings are on the conservative side, contact Nailor for requirements beyond limitations shown. *Leakage data is based upon a pressure differential of 1 in. w.g., tested in accordance with AMCA Standard 500-D. PRESSURE DROP: 3.0 (747) SIZE: 36" x 36" (914 x 914) 2.0 (498) Static Pressure Drop in inches w.g. (Pa) 1.0 (250).8 (200).6 (150).5 (125).4 (100).3 (75).2 (50).1 (25).08 (20).06 (15).05 (12.5).04 (10).03 (7.5).02 (5.0).01 (2.5) 10 (.05) 20 (.10) 30 (.15) 50 (.25) 70 (.36) 100 (.51) 200 (1.0) 300 (1.5) 500 (2.5) 700 (3.6) Air Velocity in feet per minute (m/s) 1000 (5.1) 2000 (10.2) 3000 4000 (15.2) (20.3) Tested per AMCA Standard 500-D, Figure 5.5. 55

ACKDRAFT DAMPERS HOW TO SPECIFY ACKDRAFT DAMPERS MODEL: 1370 ACKDRAFT DAMPERS SUGGESTED SPECIFICATION: Provide and install, as shown on plans and/or schedules, backdraft dampers as manufactured by Nailor Industries, Inc. which meet or exceed the following criteria: Frame shall be constructed of.090" (2.3) type 6063-T5 extruded aluminum with welded mitered corners and concealed reinforcing brackets. lades shall be.050" (1.3) type 6063-T5 extruded aluminum on maximum 3 5/8" (92) centers with extruded PVC blade seals mechanically fastened to blade edge. Adhesive type seals are not acceptable. earings shall be long life synthetic type. lade linkage shall be concealed in frame for low pressure drop. Standard of acceptance shall be Nailor Industries Model 1370. MODEL: 1380 HIGH PERFORMANCE ACKDRAFT DAMPERS SUGGESTED SPECIFICATION: Provide and install, as shown on plans and/or schedules, backdraft dampers as manufactured by Nailor Industries, Inc. which meet or exceed the following criteria: Frame shall be constructed of.125" (3.2) type 6063-T5 extruded aluminum with welded mitered corners and concealed reinforcing brackets. lades shall be.070" (1.8) type 6063-T5 extruded aluminum on maximum 5 1/2" (140) centers with extruded PVC blade seals mechanically fastened to blade edge. Adhesive type seals are not acceptable. earings shall be long life synthetic type. lade linkage shall be plated steel tie bar with stainless steel pivot pins. Standard of acceptance shall be Nailor Industries Model 1380. MODEL: 1370C COUNTERALANCED ACKDRAFT DAMPERS SUGGESTED SPECIFICATION: Provide and install, as shown on plans and/or schedules, counterbalanced backdraft dampers as manufactured by Nailor Industries, Inc. which meet or exceed the following criteria: Frame shall be constructed of.090" (2.3) type 6063-T5 extruded aluminum with welded mitered corners and concealed reinforcing brackets. lades shall be.050" (1.3) type 6063-T5 extruded aluminum on maximum 3 5/8" (92) centers with extruded PVC blade seals mechanically fastened to blade edge. Adhesive type seals are not acceptable. earings shall be long life synthetic type. lade linkage shall be concealed in frame. Counterbalances shall be of plated steel, mounted on rear of blades, internally in the airstream, and shall be field adjustable. Standard of acceptance shall be Nailor Industries Model 1370C. MODEL: 1380C HIGH PERFORMANCE COUNTERALANCED ACKDRAFT DAMPERS SUGGESTED SPECIFICATION: Provide and install, as shown on plans and/or schedules, counterbalanced backdraft dampers as manufactured by Nailor Industries, Inc. which meet or exceed the following criteria: Frame shall be constructed of.125" (3.2) type 6063-T5 extruded aluminum with welded mitered corners and concealed reinforcing brackets. lades shall be.070" (1.8) type 6063-T5 extruded aluminum on maximum 5 1/2" (140) centers with extruded PVC blade seals mechanically fastened to blade edge. Adhesive type seals are not acceptable. earings shall be long life synthetic type. lade linkage shall be plated steel tie bar with stainless steel pivot pins. Counterbalances shall be of plated steel, mounted on rear of blades, internally in the airstream, and shall be field adjustable. Standard of acceptance shall be Nailor Industries Model 1380C. 60

ACKDRAFT DAMPERS HOW TO ORDER MODELS: 1370, 1380, 1370C AND 1380C ACKDRAFT DAMPERS AND COUNTERALANCED ACKDRAFT DAMPERS EXAMPLE: 1370-24 x 24 - HMU - FF - MI - GS 1. Models 4. Frame Type 1370 Extruded Aluminum, CF Channel (default) Light/Medium Duty FF Front Flange 1380 Extruded Aluminum, FF Front Flange with olt Holes Heavy Duty FR Rear Flange 1370C Counterbalanced, FR Rear Flange with olt Holes Extruded Aluminum, Light/Medium Duty 5. Finish MI Mill 1380C Counterbalanced, Extruded Aluminum, 6. ird Screen (not available on Models 1370C & 1380C) Heavy Duty None (default) 2. Duct Size AIS Aluminum Insect Screen Width x Height (inches [mm s]) 3. Mounting GS Galvanized Steel ird Screen VM Vertical Mount (default) HMD Horizontal Mount (Air Down) (Models 1370C and 1380C only) HMU Horizontal Mount (Air Up) Note: 1. Not all variants and options are available on all models. Refer to individual model for selection availability. ACKDRAFT DAMPERS 61