BML-S1B0-Q _-M _-_0-KA. User's Guide. english

Similar documents
User's Guide. Magnetic Tape Magnet Rings

Manual Electronic Identification Systems BIS Read/Write Heads C3-slk_716464_E_1110.p65 Deutsch bitte wenden!

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

BSW , -204 Inductive Rotary Cam Switches. User's Guide. Rotary Cam Switches BSW BSW

manual magnetic linear measurement system MW10

EBOX SMB5, SMB2 SM5, SM2 MT50, MT20

ENC 150 REFERENCE MANUAL ACU-RITE

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Safety Sensor CSS 180 Product Information

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

JUMO MIDAS S05 Pressure transmitter Type

Series 7000 Torque Sensor for PTO-shafts

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Series 7000 Torque Sensor for PTO-shafts

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

* _0916* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Synchronous Linear Motors SL2

Electronic pressure switch with two switching outputs

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Electronic pressure switch with integrated analogue output

Pressure Transmitter JUMO dtrans p30 Type

Electric Mini Slides MSC-EL

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Dual Channel Speed Sensor GEL 2475

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Standard cylinders DDPC, with measured-value transducer DADE

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Inductive Special Properties

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

HF Series Incremental Magnetic Encoder Decade Count High Resolution Kit

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

standards based cylinder DNCI Operating instructions e [ ]

Operating Instructions. Angle Seat Control Valve. Type 7020

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Self-Adjusting Two-Wire Hall Effect Gear Tooth Sensor IC CYGTS9804

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

! CAUTION! Damages on the machine possible.

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

METEOROLOGICAL INSTRUMENTS

Weatherproof Tubular Slip Ring Assembly

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

METEOROLOGICAL INSTRUMENTS

User Manual Solar Charge Controller 3KW

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Integrated Measuring System IMS for Ball and Roller Rail Systems

Profibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

DATAFLEX 42/1000 Torque Measuring Shaft Operating/Assembly instructions DATAFLEX

DC POWER SUPPLY ALIMENTATION C.C.

WATERFLUX 3070 Quick Start

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

JUMO ecotrans Lf 01/02

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Electronic Limit Switch Type

SSI. Synchronous Serial Interface

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

User Manual. Solar Charge Controller 3KW

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Your Global Automation Partner. LTX Linear Position Sensors with SSI Interface. Operating instructions

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

JUMO MIDAS Pressure transmitter

POSIMAG - PMIS3 / PMIS4 Magnetic Scale Position Sensors

Space-saving installation Flexible motor mounting

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

MiniCoder GEL Operating Instructions. Speed and position sensor optional with amplitude control

See «Overview of types»

Float switch For industrial applications, with temperature output Model RLS-3000

Flexible. Fast. Reliable. ELM Compact Linear Module

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Contents. 1. Preface Product Outline Model Number Construction Specifications Outline Drawings and Wiring diagram...

Temposonics. Magnetostrictive Linear Position Sensors. GB-Series Analog Operation Manual

Inductive Proximity Sensor

MF /MS Series

Motion without compromise

Pressure Transmitter JUMO dtrans p30 Type

Type Electronic Limit Switch

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Sensor-Bearing Units Steer-By-Wire Modules Mast Height Control units Other sensorized units

STT280 SEALED TILT SENSOR

Transcription:

english User's Guide Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Phone +49 (0) 71 58/1 73-0 Fax +49 (0) 71 58/50 10 Servicehotline +49 (0) 71 58/1 73-3 70 E-Mail: balluff@balluff.de http://www.balluff.de

Content 1 Safety Advisories... 2 1.1 Intended use... 2 1.2 Qualified personnel... 2 1.3 Use and testing... 2 1.4 Validity... 2 2 Functional variants... 3 3 Function and Characteristics... 4 3.1 Characteristics... 4 3.2 Principle of operation... 4 3.3 Interface signals... 4 3.4 Limit switch function... 4 3.5 Reference point function... 5 4 Installation... 6 4.1 Distances, tolerances... 6 4.2 Determining orientation... 7 4.3 Attaching sensing head... 7 4.4 Gluing the tape... 7 4.5 Installing limit switches... 8 5 Wiring... 9 5.1 Cable assignments... 9 5.2 Connecting the Sense line... 9 5.3 Interfaces... 10 6 Startup... 11 6.1 Check connections... 11 6.2 Turn on system... 11 6.3 Check system function... 11 6.4 Regular checking... 11 6.5 Malfunction... 11 7 Accessories... 11 7.1 Limit switch magnets... 11 7.2 Tape cover... 11 8 Troubleshooting... 12 9 Technical Data... 13 10 Scope of Delivery... 14 11 Versions (indicated on part label)... 15 1 Safety Advisories Read this manual before installing the sensor and placing it in operation. 1.1 Intended use The BML displacement sensor is installed for use in a machine or system. Together with a controller (PLC) it comprises a displacement measurement system and may be used only for this purpose. Unauthorized modifications and non-allowed use will result in loss of guarantee and warranty. 1.2 Qualified personnel This manual is intended for technical personnel who are involved in installation and setup. 1.3 Use and testing Prevailing safety regulations and codes must be observed for using the displacement sensor. In particular, measures must be taken to ensure that a defect in the displacement sensor will not result in hazards to persons or equipment. This includes installation of additional safety limit switches, emergency stop switches, and the maintaining of permissible ambient conditions. BML displacement sensors may not be used in life-saving systems, in aircraft, etc. 1.4 Validity This manual is applicable to displacement sensors of type BML-S1B...-KAxx. An overview of the various versions can be found in section 11 "Versions" (refer to part label). The CE Mark verifies that our products meet the requirements of EC Directive 89/336/EEC (EMC Directive) and the EMC Law. Testing in our EMC Laboratory, which is accredited by DATech for Testing Electromagnetic Compatibility, has confirmed that Balluff products meet the EMC requirements of the following Generic Standards: EN 61000-6-4 (emission) EN 61000-6-2 (noise immunity) Emission tests: RF Emission EN 55011 Group 1, Class A+B Noise immunity tests: Static electricity (ESD) EN 61000-4-2 Severity level 3 Electromagnetic fields (RFI) EN 61000-4-3 Severity level 3 Fast transients (Burst) EN 61000-4-4 Severity level 3 Surge EN 61000-4-5 Severity level 2 Line-induced noise induced by high-frequency fields EN 61000-4-6 Severity level 3 Magnetic fields EN 61000-4-8 Severity level 4 2 english

2 Functional variants of the BML-S1B displacement sensor The BML is a non-contacting, incremental displacement measurement system which in addition to a counting function is available with a reference point and limit switch function. All functions are implemented by means of magnetic sensing.the reference position is integrated in the tape, and limit switches can be attached at any desired position. The following table show the functional variants with their possibilities. Output signal Reference signal Limit switch A/B periodic one none front and back none Variant 1 Incremental sensors Tape with alternating northand south poles Fig. 2-1: Displacement system with incremental sensors Variant 2 Incremental sensors Reference point sensor Magnetic reference point Fig. 2-2: Displacement system with incremental and reference point sensors Limit switch sensors Incremental sensors Magnetic reference point Variant 3 Reference point sensor Limit switch magnet Fig. 2-3: Displacement system with incremental, reference point and limit switch sensors english 3

3 Function and Characteristics 3.1 Characteristics BML displacement sensors are characterized by: High system accuracy of 50 µm High resolution of up to 5 µm High traverse speed of up to 10 m/s Position signal in real-time Insensitive to shock, vibration, and contamination such as dust and oil Wear- and maintenance-free Rugged Enclosure rating IP 67 per IEC 60529 3.2 Principle of operation The sensing head is attached to the machine member whose position is to be determined, while the magnetic tape is mounted along the direction of travel. The tape contains alternating magnetic north- and south poles. The two incremental sensors in the sensing head measure the magnetic alternating field. As the sensing head travels over the tape the two incremental sensors pick up the magnetic periods so that the controller can determine the distance traveled. 3.3 Interface signals The sensing head can convert the sinusoidal and cosinusoidal signals either into A/B pulses and send them to the controller (RS422). The digital A/B pulses are interpolated in the sensing head. The two digital pulses A and B are 90 phase-shifted, with the sign of the phase shift determined by the direction of travel of the sensor (Fig. 3-1). Signal A Signal B Increment Direction of motion Counter state Each edge change from A or B represents a counting step for the period counter (UP/DOWN counter). When Signal A is ahead, the counting state increases, and when Signal B is ahead the count decreases. The controller thus always knows the increment-precise position without having to periodically poll the sensor (realtime capability). Fig. 3-1: Digitized sinusoidal and cosinusoidal signals with period counter 3.4 Limit switch function When limit switch functionality is needed, sensing heads can be equipped in addition with a limit switch sensor which senses opposite pole permanent magnets at the ends of the measuring range and sends the signals to the controller (Fig. 3-2). forwards backwards The limit switch sensors function then even if the rest of the sensor fails (security function). If the actuation range of the limit switches needs to be longer than their length (20 mm), multiple limit switches of the same type can be mounted in rows. Limit switch sensor Incremental sensors Limit switch magnet rear Limit switch magnet front Fig. 3-2: Displacement measurement system with limit switch function 4 english

3 Function and characteristics (cont.) 3.5 Reference point function The reference position is always required as the starting point for the count for each incremental displacement system. How the reference position is determined depends on the sensor type, the tape and on the controller. In the simplest system the sensing head with the sinusoidal and cosinusoidal sensors can count only the magnetic periods. The tape contains only one track with magnetic north and south poles (Fig. 3-3). In this case the displacement measuring system does not know the absolute position. This is determined by the controller by adding the counted increments. First however the reference position must be determined by a homing move to the reference switch. A sensing head with an additional reference point sensor can output a reference point signal as soon as it reaches the magnetically encoded reference point on the second track of the tape (Fig. 3-4). Then an reference switch is not needed. In another sensing head version a reference point signal is output with each magnetic pole. This signal is repeated every 5 millimeters. The tape does not require a second track with a magnetically encoded reference point. Incremental sensors In this case an reference switch needs to be used for the selected reference signal. The controller precisely evaluates the reference position when the switch and the reference point signal of the sensing head are active. The accuracy requirement for this switch is not especially great. Single-track tape Fig. 3-3: Displacement measurement system without reference point or limit switch function Incremental sensors Two-track tape Reference point sensor Magnetic reference point Fig. 3-4: Displacement measurement system with reference point function english 5

4 Installation Important installation notes: The permissible distance and angle tolerances as per Figs. 4-2, 4-3 and 4-4 must be strictly observed. The sensing head may not come in contact with the tape at any point along the travel. Contact must still be avoided if the stainless steel cover (optional) is used. The magnetic tape must not be subjected to strong external magnetic fields. Direct contact with holding solenoids or other permanent magnets must be avoided. The displacement measurement system must be installed in accordance with the specified enclosure rating. Fig. 4-1: Dimensional drawing 4.1 Distances, tolerances The following distances and tolerance must be observed when installing the sensing head and tape: The distance (air gap) between sensing head and tape as per Fig. 4-2 The horizontal offset between sensing head and tape as per Fig. 4-3 The angle tolerances as per Fig. 4-4. Any tilt along the longitudinal axis of the sensing head must still maintain the nominal distance to the tape in the center of the head. The two incremental sensors are located there on the underside. Tape Stainless steel cover Fig. 4-2: Permissible air gap between sensing head and tape Tape without single reference point Tape with single reference point Fig. 4-3: Permissible horizontal tolerance Note: Even slight tolerance deviations can affect the measuring result. The specified systen accuracy applies only if the tape is installed parallel to the direction of travel. Fig. 4-4: Permissible angle tolerances Tape 6 english

4 Installation (cont.) 4.2 Determining orientation The orientation with respect to front, back, right and left is used in the installation description and is critical for correct installation of the sensing head and tape. Starting from the travel direction of the sensing head the orientations are defined in Fig. 4-5. back left side right side Fig. 4-5: Orientation Travel direction Reference point front 4.3 Attaching sensing head The sensing head is attached with M3 screws at its right or left side to the machine member whose position you are sensing. 4.4 Gluing the tape Note: Attach the tape parallel to the direction of travel and completely flat on the mounting surface. Wavy or tilted tapes will affect the measuring accuracy. Never stretch or crimp the tape while installing, otherwise nonlinear measurements will result. Once glued do not remove (even partially) the tape. Strong nonlinearity effects will be observed at the place where the tape was lifted. Keep magnetized parts away from the tape to prevent non-linear effects. For optimum gluing an ambient temperature of 0 to 40 C is recommended. For tapes with a reference track you should identify the front and back end so that the tape is installed appropriately to the count direction of the sensing head. The reference point is visually marked (Fig. 4-5). Installation options (Figs. 4-6): Pos. 1: For normal ambient conditions glue the tape down to a level surface. Optionally the cover band can be glued on for protection. Pos. 2: For harsh ambient conditions embed the tape fully in a somewhat deeper channel so that it does not extend over the top. Optionally the cover band can be glued on for protection Pos. 3: For harsh ambient conditions embed the tape fully in a somewhat deeper channel and fill with non-magnetizable material (such as adhesives). The fill material can be leveled by lightly sanding. Tape cover Tape Machine Tape cover Tape in a slot Fill material Tape in a slot Securing the ends of the tape Fig. 4-6: Installation options for the tape Installing the tape Note The tape must always be mounted flush with the left and right side of the sensing head. 1. Thoroughly remove any oil, grease, dust, etc. (use acetone or similar) from the mounting surface and allow to dry completely. 2. For tapes with a reference position, identify front and back end: the reference point is visually marked and is located on the right side of the tape in its own track. For the system to function the reference track of the tape must lie on the right side of the sensing head (Fig. 4-5). For tapes with no reference position no front-back orientation is required. 3. Position the sensing head at the back end of the tape (start of the measuring range). 4. Pull back the film from the back end of the tape and lightly attach the tape. 5. Remove another section of film. 6. Move the sensing head a short distance further while aligning the tape flush with the left and right side of the sensing head. 7. Gently press the tape behind the sensing head. Caution! Do not use a hard tool, otherwise the magnetic surface may be damaged! 8. Optional: To protect the tape from mechanical and chemical effects, glue the stainless steel cover in place (details see section 7.2). english 7

4 Installation (cont.) 4.5 Installing limit switches The front and rear limit switch magnets must always be installed on the right side of the sensing head. When the limit switch is in a housing always attach the front magnet with its nose facing back and the rear magnet with its nose facing front. When the limit switch is not in a housing install the rear magnet with its N pole (marked by a line) facing the sensing head and the front magnet with its S pole facing the head (Figs. 4-7, 4-9). The following applies to both limit switch types: If the E-stop travel exceeds the length of the limit switch magnet, multiple magnets may be installed in a row (Fig. 4-7). The limit switch sensor becomes active as soon as it begins to enter the magnetic field of the limit switch magnet (Fig. 4-8). Limit switch magnet rear Limit switch magnet rear: Slot left of center right side Fig. 4-7: Installing the limit switch magnets The limit switch is active at about this point Limit switch magnet front Limit switch magnet front: Slot right of center E-stop travel Travel direction (measuring range) E-stop travel Fig. 4-8: Traverse and E-stop distances for limit switches with and without housing Sensing head Limit switch glued to machine Tape Maintain distance from mounting Fig. 4-9: Installation example for limit switch without housing 8 english

5 Wiring Note the following when making electrical connections: The system and the control cabinet must be at the same ground potential. To ensure EMC, which Balluff confirms with the CE Marking, the following instructions must be followed. The cable shield must be grounded on the controller side, i.e., connect to the protection ground. The connection on the sensor side depends on the configuration. When routing the cable between the transducer, controller and power supply avoid proximity to highvoltage lines due to noise coupling. Especially critical are stray coupling caused by AC harmonics (e.g., from phase controls), against which the cable shield offers little protection. Cable length max. 20 m; conductor cross-section min. 0.14 mm 2, max. 0.5 mm 2. Longer cables may be used if their construction, shielding and routing resist external noise fields. Important: In spite of a voltage drop in the line a nominal operating voltage of 10 bis 30 V or 5 V ±5% must be ensured (see 5.2). 5.1 Cable assignments 12-conductor cable with Sense line for preventing voltage drop in the line. Cable Signal WH white A BN brown /A or n.c.* GN green B YE yellow /B or n.c.* GY gray Z PK pink /Z or n.c.* BU blue GND RD red +5 V or 24 V BK black GND Sense VT violet +5 V/24 V Sense GYPK gray/pink Limit switch front RDBU red/blue Limit switch back * only for BML-S1B0-Q53 5.2 Connecting the Sense line To avoid a voltage drop in the line a regulated power supply with Sense input should be used (Fig. 5-1). If that is not possible or desired, the Sense lines in the 12-conductor cable should be connected parallel to the +5 V and GND line (Fig. 5-2). When operating at 10...30 V you must ensure that the voltage does not drop below 10 V. Such a power supply does not normally possess a Sense line. Power supply Fig. 5-1: Power supply with Sense line Power supply Fig. 5-2: Power supply without Sense line Calculating the voltage drop in the line For the 5 V version of the BML the supply voltage must be 5 V ±5%. The power supply must ensure this voltage and also compensate for the voltage drop in the line. When operating at 10...30 V the voltage must be >10 V. Use the following formula to calculate the voltage drop in the line: U line = R l x l x [n x 3.1/R st + 0.03] where: U line = Voltage drop in the line in Volt R l = 0.23 for the parallel wiring of the Sense lines with the supply lines (Fig. 5-2) l = Cable length in m n = 3, if the reference pulse is processed in the controller 2, if the reference pulse is not processed in the controller = Input impedance of the controller in Ohm R st Sample calculation Under the following conditions: cable length 5 m Reference pulse is evaluated Control input impedance = 120 Ω Resulting voltage drop is: U line = 0.23 x 5 x [3 x 3.1/120 + 0.03] = 0.112 V english 9

5 Wiring (cont.) 5.3 Interfaces Digital incremental system The sensor transmits the measured variable to the controller as a digital differential voltage signal (RS422) or as an operating voltage signal (HTL). The edge separation A/B corresponds to the resolution of the sensing head. Signal periode 360 el. Circuit for reference position Depending on the model, the sensor sends either no reference signal, a single reference signal which is magnetically encoded in the tape, or a periodic reference signal (period = 5 mm, width of the reference signal = edge separation, Fig. 5-3). In the latter case an external reference switch must be attached to the desired reference signal. The accuracy requirements of this switch are not especially high. Note: The reference signals from the limit switch area are not allowed to be processed. Circuit for limit switch front and back The opposite poled permanent magnets at the ends of the measuring range are each sensed by a limit switch sensor. The sensor has a normally closed function, so that cable break can be detected. Fig. 5-6: Limit switch circuit Controller Limit switch front Limit switch rear Edge separation Reference puls Fig. 5-3: Digital output signals External switch Reference signal for the controller Fig. 5-5: Reference position circuit Limit switch rear Limit switch front Fig. 5-7: Limit switch signals A channel Relationship between mechanical resolution and max. frequency B channel Reference channel * only for BML S1B0-Q61... ** only for BML S1B0-Q51... The 24 V inputs are connected to digital inputs on the controller. The requirements for your controller (counting frequency) and for the traverse speed of your system can be determined from the BML model used (see part numbering code, p. 15). Note the values from the following table. Resolution (µm) Example for table line 1: Using a BML with a resolution of 5 µm and a max. speed around 1 m/s ("slow" model) the results are as follows: - The smallest edge separation which your controller must be able to count is 3.1 µs. min. possible edge separation (µs) for BML model: "slow" (V max approx. 1 m/s) 5 3.1 0.29 10 6 0.58 25 15.8 1.56 30 15.8 1.56 "fast" (V max approx. 10 m/s) Fig. 5-4: Circuit for following electronics 10 english

6 Startup 6.1 Check connections Caution! The connections are not protected against polarity reversal or short circuit! Before turning on power, check the connections carefully to prevent components from being destroyed by incorrect connections or overvoltage. 6.2 Turn on system Bear in mind that the system may make an uncontrolled move when first powered up, especially at initial startup and if the displacement sensor is part of a control system whose parameters are not yet set. Therefore be sure that no hazards could result from an unpredictable start. 6.3 Check system function After installing the transducer system or replacing the sensing head, check all functions as follows: 1. Turn on power to the sensing head. 2. Move the sensing head along the entire measuring range. 3. Check whether all signals are output. 4. Check whether the count direction agrees with the direction of travel. If not, reverse connections A and /A. 6.4 Regular checking The functionality of the transducer system and all its associated components should be checked and logged at regular intervals. 6.5 Malfunction If there is any indication that the transducer system is not functioning properly, remove it from service and secure it against unauthorized use (see also Troubleshooting). 7 Accessories (order separately) 7.1 Limit switch magnets (BML-Z0006) The magnets can be used with or without housing. The through-holes make it easy to precisely install these limit switch magnets (Fig. 4-8). The housing should be fitted with a magnet only on its side facing the sensor. The space-saving magnets can be glued or attached using customersupplied holders. The upper side is marked with a notch. If the E-stop travel exceeds the length of the limit switch magnet, multiple magnets may be installed in a row (for installation see 4.5). The scope of delivery includes: 2 magnets with housing 2 magnets without housing, and 1 installation guide Fig. 7-1: Magnet and housing 7.2 Tape cover To prevent damage to the tape from things like chips or chemicals, it may be covered with a strip of stainless steel. Note that the permissible air gap between the sensing head and tape is reduced now by the thickness of the cover strip with adhesive film (0.15 mm) (Fig. 4-2). Before adhering the cover strip, thoroughly clean the surface of the tape (acetone, terpentine, mild plastic cleaner, no gasoline). Ship configurations: 1 Tape cover and tape can be ordered together in the appropriate length. See ordering code p. 16. 2 The tape cover may be ordered in 3 defined lengths. See ordering code p. 15. english 11

8 Troubleshooting Error Possible causes Remedy/Explanation The controller is not getting The necessary supply voltage is PCheck whether voltage is present (in places) any information not present and the BML is properly connected The voltage drop is too high (see calculation formula on page 9) The lines are not correctly connected The transducer system requires a supply voltage of 10...30 V or 5 V ±5%. Check the voltage on the Sense line or by using the formula (page 9) Check the lines according to the schematic diagrams The orientation of the 2-track tape is incorrect The reference point marking must be on the right side of the Ssensinghead (Fig. 4-5). Correctly install a new tape. At certain points the controller The distance between the sensing Adjust the height of the sensor. To does not get any distance head and tape is (in parts) incorrect check, manually move the sensing information head over the entire measuring range The magnetic poles of the tape are damaged in places from the effect of strong external magnets Replace the tape Position signal very noisy Distance between sensing head Attach the sensing head closer to and tape is too great the tape Limit switches not switching The distance between the limit Check distance to sensing head nswitch magnets and the sensing and angle to tape (Fig. 4-7) and head is incorrect correct as necessary. The limit switch magnets are installed with the wrong side facing the sensing head (wrong polarity) Check position of the limit switch magnets with respect to the travel direction (Fig. 4-7) and correct as necessary Reference point signal not output The orientation of the 2-track tape The reference point marking must is incorrect be on the right side of the sensinghead (Fig. 4-5). Correctly install a new tape. The linearity deviation is outside The sensor head does not move Correctly position the sensing the tolerance parallel to the tape (see Fig. 4-4 for head (section 4) tolerances) The distance between the sensing head and the tape is too large 12 english

9 Technical Data Electrical data Type BML-S1B0-Q Output digital RS422 or supply voltage level (HTL) Output signal A-Signal, B-Signal, reference signal Reference signal no, one, periodic signal Resolution 5 µm, 10 µm, 25 µm, 50 µm, 100 µm, 200 µm, 500 µm, 1000 µm, 2000 µm Output voltage Differential signal per RS422 or same as operating voltage (HTL) Limit switch U max = 28 V, I max = 20 ma, N.C., GND switching (cable break monitor) System accuracy ±50 µm up to 1 mm distance, above that ±60 µm Hysteresis depends on air gap 3 to 7 µm max. non-linearity of the ±20 µm processing electronics unidirectional max. non-linearity of the ±50 µm within any one meter at a distance range up to 1 mm overall system (sensing head + tape) ±60 µm within any one meter at a distance range 1... 2 mm Temperature coefficient 10.5 x 10-6 K -1 of overall system like steel Max. traverse speed depends on model, see table p. 10 Reverse polarity protected no Overvoltage protected no Supply voltage 5 V ±5% or 10...30 V Current draw at 5 V operating voltage <50 ma + current draw of controller (depending on internal resistance) Current draw <40 ma + current draw of controller (depending on internal resistance) at 10...30 V operating voltage Shock load per IEC 60068-2-27 1 100 g/6 ms Continuous shock per IEC 60068-2-29 1 100 g/2 ms Vibration per IEC 60068-2-6 1 12 g, 10...2000 Hz Ambient conditions Operating temperature 20 C...80 C Storage temperature 30 C...85 C Degree of protection per IEC 60529 IP67 Mechanical data Sensing head to tape gap 0.01...2 mm Housing material plastic Connection 12-conductor cable Weight 11 g without cable 1 Individually determined as per Balluff Factory Standard english 13

9 Technical Data (cont.) Tape BML-M01-... Accuracy class ±18 µm Thickness without cover strip 1.75 ±0.05 mm with cover strip 1.90 ±0.05 mm Width 10 mm Length depending on tape type max. 24 m Pole width (distance north-south pole) 5 mm Single reference mark optional max. non-linearity ±18 µm within any one meter Weight 70 g/m Recommended operating temperature 0...40 C Chemical resistance Resistant to oils (motor oil, transmission fluid, hydraulic fluid), terpentine, antifreeze, water, kerosene. Not resistant to aromatic and chlorinated hydrocarbons, ketones, inorganic acids 10 Scope of Delivery Sensing head Short guide Stainless steel cover strip BML-A... Thickness Width Length approx. 0.15 mm (incl. adhesive film) 10 mm Same as tape length, or fixed lengths Limit switch magnet BML-Z0006 Dimensions L x W x H Magnet housing Limit switch magnet 20 x 12 x 9.5 mm 20 x 2 x 5 mm Cable Type Operating temperature Flexed 20...80 C Fixed 40...90 C Cable diamter 5.4 ±0.2 mm Cable bending radius Flexed 81 mm Fixed 41 mm PU cable:12-conductor, drag chain compatible 14 english

11 Versions Part numbering for sensing head (printed on part label) BML - S1 B 0 - Q 5 3 G - M 4 1 3-1 0 - KA05 (example) Connection: KA05 = Cable 5 m Possible cable lengths: 2, 5, 10, 15, 20 m max. traverse speed: 1 = 1 m/s (slow) 2 = 10 m/s (fast) Limit switch 0 = no limit switch 3 = two limit switches Reference signal 0 = no signal 1 = single signal 2 = periodic signal Pole width 4 = 5 mm Resolution (edge separation A/B) F = 5 µm G = 10 µm H = 25 µm K = 50 µm L = 100 µm M = 200 µm N = 500 µm P = 1000 µm R = 2000 µm Output voltage 1 = digital differential signal RS422 3 = level same as supply voltage (only for 10...30 V) Supply voltage 5 = 24 V (10...30 V) 6 = 5 V Part numbering for tape cover strip without tape BML - A 0 1 3 - T 0500 (example) Available lengths: 0500 = 5 m 1000 = 10 m 2400 = 24 m Form factor, width 01 = incremental 10 mm wide english 15

11 Versions (cont.) Part numbering for pre-assembled tapes, optional with tape cover (indicated on packaging) BML - M 0 1 - I 4 5 - A3 - M 0106 - R 0020 (example) Reference point position only for single reference signal in sensing head: xxxx = for xxxx cm from rear (in example 20 cm*) 0000 = no reference point Length in cm: Order length = effective measuring length + 6 cm (here 100 + 6 cm) Tape cover: 0 = no cover 3 = with cover BML - M 0 1 - I 4 5 - A0 - T 0500 - R 0000 (example) Accuracy class: 5 = 18 µm (overall accuracy ±20 µm) Pole width 4 = 5 mm Type I = incremental Form factor 01 = linear, incremental 10 mm wide *The reference point in the example is physically located approx. 25 cm from the beginning of the tape Part numbering tapes from a roll, without cover (indicated on packaging) Reference point position: 0000 = no reference point possible Available lengths: 0500 = 5 m 1000 = 10 m 2400 = 24 m Accuracy class: 5 = 18 µm (overall accuracy ±20 µm) Pole width 4 = 5 mm Type I = incremental Form factor 01 = linear, incremental 10 mm wide No. 841 971-726 E 01.105886 Edition 0512; specifications subject to changes. Replaces edition 0506 16 english