Air Regulator 100 psi (.7 MPa, 7 bar) Maximum Air Inlet Pressure

Similar documents
Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Air Control Kits INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

INSTRUCTIONS PARTS LIST

Stainless Steel Air Motor Conversion Kits

Pro Shot Grease Dispense Valve

Stainless Steel Air Motor Conversion Kits

Universal Hand Pump. Instructions D EN. - For transferring grease to Grease Jockey and G3 Systems - Part No Hand Operated - 35# Pump

Pump Package Conversion Kits

PROVEN QUALITY, LEADING TECHNOLOGY

Cleaning System. Instructions/Parts A

Color Change Valve. Instructions Parts List K

Pressurized oil drain for collection of used lubricants and anti-freeze.

Electronic Pulse Meters

24G621 Agitator Speed Controller Accessory

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

Motor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors

15H882 Slider Bearing Kit

Old Proportioning Pumps

Low Pressure Fluid Filters

Mechanical Pulse Meter

Integrated and 2-Button Interlock Air Controls for use with Supply Systems.

Merkur Displacement Pump

Elevators and Pump Supports

Vertical Hydraulic Driver

Air Actuated Dispense Valve

Field Sensitive Magnetic Proximity Cycle Switch

Fuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels.

390 Airless Sprayer. Parts J EN. Models: , , , , , ,262024, , , , Hi-Boy.

Instructions Parts List

Horizontal Hydraulic Driver

Split Manifold Kits. Installation Parts List C. Converts Husky 307 Diaphragm Pump to dual fluid inlet or outlet

950SeriesSealantGun. Instructions-Parts D. Models Palm Grip Gun: Pistol Grip Gun: ENG

Ultimate Mx II. Parts List E psi (228 bar, 22.8 MPa) Maximum Working Pressure. Vac Model Type Lo-Boy Hi-Boy. Sherwin Williams 120V

Air Actuated Dispense Valve

4:1 Fusion Static Mixer Kit

Model For petroleum products and other fluids compatible with aluminum and buna-n seals.

Displacement Pump. Instructions C EN. Model psi (3.7 MPa, 37 bar) Maximum Working Pressure 12 gpm Flow Rate

Split Manifold Kits. Installation - Parts List D. Converts Huskyt 307 Diaphragm Pump to dual fluid inlet or outlet

Stainless Steel 1000cc Lower

Instructions 3A4793B EN. See page 3 for a complete list of model descriptions and part numbers.

Displacement Pump INSTRUCTIONS-PARTS LIST psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A. Model , Series A

Fast-Flo Air Motor 12.5 bar (1.25 MPa, 180 psi) Maximum Air Working Pressure

Repair D EN. Displacement Pump. Model , Series A 190ES/ 210ES, 190LTS/210LTS Pro 230ES, Pro 270ES Pro 270GS

RS Gun Front Adapter Kits

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Displacement Pump 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A

Displacement Pump 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A

INSTRUCTIONS-PARTS LIST

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Old Seal Kits. Instructions - Parts B. Piston Seal Kits, see page 2. Cylinder Seal Kits for A-Side Pumps, see page 2

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

ST Max 395/495/595 ST Max II 490/495/595

Single Acting and Double Acting Paint Spray Guns for RoadLazer RoadPak Line Striping System

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

Spray Nozzle Adapters

Instructions-Parts 3A2801G. See page 2 for model part numbers, maximum fluid working pressure, and approvals.

Proportioning pumps and hydraulic cylinders used on Hydraulic Proportioners. Model : 2000 psi (13.8 MPa, 138 bar) Maximum Working Pressure

Hose Heat Control Kit

Displacement Pump. Repair-Parts. Contents D ENG. Part No psi (13.8 MPa, 138 bar) Maximum Working Pressure

3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A Ultra Max II and Ultimate Mx II 695 and 795

PROVEN QUALITY. LEADING TECHNOLOGY.

Instructions Parts List

Displacement Pump Used in the Ultra Max 695 Sprayers 3000 psi (207 bar, 21 MPa) MAXIMUM WORKING PRESSURE

Ultra Max II Ultimate Mx II

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

Mark V Premium and Mark V Max Electric Airless Sprayers

Instructions/Parts List

Proportioning Pumps. Repair - Parts M EN

Merkur Spray Packages

Pistol Grip Mastic Flo Gun

Plus Mark V Mark V Plus

INSTRUCTIONS-PARTS LIST. BLACK MAX Airless Spray Gun psi (24.8 MPa, 248 bar) Maximum Working Pressure. Rev. F Supersedes D and PCN E

Fire-Ball 225, 300, and 425 Oil Pumps

3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure Model , Series A

2K Ultra-Lite Dispense Kits

SaniForce Air Motors. Instructions/Parts 3A1211N

Viscount I Hydraulic Motor and Displacement Pump

Airless Spray Gun. Instructions Parts List H. Model , Series H psi (21.0 MPa, 210 bar) Maximum Working Pressure

Instructions Parts List. Table of Contents F. Part No Part No

President Pump WITH PRIMING PISTON

2:1 Ratio Monark Pump

ProMix Auto Color and Catalyst Change Kits

Ultra Platinum Sprayers

Texture Gun & Hopper B

Carbon Steel 1000cc Lower

Silver Airless Spray Gun

3:1 Ratio President Pump

UltraMix Pumps. Repair - Parts A

XHF Spray Gun. Instructions - Parts 3A2799A EN. Part No , Series A

Husky 515/Husky 716 Drum Pump Kits and Packages

NXT Air Motor for FRP

Instructions Parts List

Displacement Pump. Repair-Parts. Contents B EN. Part No psi (22.7 MPa, 227 bar) Maximum Working Pressure

INSTRUCTIONS. Direct-Drive Pressure Washers

Lean Lube Valve. Instructions A. Models: page 2. - For oil and grease lubrication -

Dura-Flo Lowers A

PR70 and PR70v Integrated Heat

Power-Lock Heated Hose

Model Reverse (up cut) / inlay and grooving (Must be used with LineDriver ) GrindLazer 480 (480 cc / 16 hp)

Transcription:

INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 30934 Rev. A Air Regulator 00 psi (.7 MPa, 7 bar) Maximum Air Inlet Pressure Part No. 24479 3/4 in. npt(f) inlet and outlet Part No. 244720 3/4 in. npt(f) inlet and outlet Table of Contents Part No. 24479 Warnings...................................... 2 Installation..................................... 2 Operation..................................... 4 Service....................................... 5 Parts......................................... 6 Technical Data................................. 9 Graco Warranty............................... 0 Toll-Free Graco Phone Number................. 0 TI22A Part No. 244720 TI29A GRACO INC. P.O. BOX 44 MINNEAPOLIS, MN 55440 44 COPYRIGHT 200, GRACO INC. Graco Inc. is registered to I.S. EN ISO 900

Symbols Warning Symbol This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. This equipment is for professional use only. Read all instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. Do not alter or modify this equipment. Check equipment daily. Repair or replace worn or damaged parts immediately. Follow the Pressure Relief Procedure on page 4 if the spray tip clogs and before cleaning, checking or servicing the equipment. Do not exceed the maximum working pressure of the lowest rated system component. Refer to the Technical Data on page 9 for the maximum working pressure of this equipment. Always wear protective eyewear when operating or servicing this equipment. Comply with all applicable local, state, and national fire, electrical, and safety regulations. Prepare the Site NOTE: Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system. Bring a compressed air supply line from the air compressor to the pump location. Be sure all air hoses are properly sized and pressure-rated for your system. Use only electrically conductive hoses. The air hose should have a 3/4 npsm(m) thread. Before installing any air line components, blow out the air lines to remove scale and other debris. Use pipe compound or tape sparingly and only on male threads. Installation Install a bleed-type shutoff valve in the air line upstream from all other air line components, to isolate them for servicing. CAUTION Do not hang the air control kit directly off the pump air motor inlet, which could be damaged by the weight and operating stress. Use a bracket to mount the kit to a cart or to the wall.

Installation Kit Components (see page 6) A bleed-type master air valve (5) is supplied. This valve relieves air trapped between it and the pump when the valve is closed, to help reduce the risk of serious injury, including fluid injection and splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump. The bleed-type master air valve (4) is supplied to relieve air trapped between it and the air motor when the valve is closed (see the above). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air filter/regulator (). Fig. 2. The air filter/regulator () controls pump speed and outlet pressure by adjusting the air pressure to the pump. It also removes harmful dirt and moisture from the compressed air supply. Locate the regulator as close as possible to the equipment it serves, but upstream from the bleed-type master air valve (4). Install the regulator in the air line so the air flow is in the direction of the arrow stamped on the body. Fig. 2. Using the Pipe Port Inserts To open the pipe port insert (A), remove the insert pin (S) and pull insert up in direction away from pin hole. Install new insert and reinsert pin. Fig.. Fig. A S TI249A Adding a Lubricator (Accessory) To add an accessory air line lubricator to the kit, you must order Part No. 24484 Lubricator Accessory Kit.. Remove filter/regulator from mount bracket. 2. Remove the pin (B) from the outlet of the filter/regulator. Fig. 2 3. Remove regulator cover. 4. Slide the threaded end insert off (3)with outlet fittings still attached. 5. Install the modular connector (2a) (with o rings and grease provided) between the filter/regulator and the lubricator (L). 6. Install the threaded end insert (3) onto the outlet of the lubricator (L)(with o ring and grease). 7. Install the three retaining pins (B). NOTE: On light weight cart units only, replace the 3/4 npt pipe extension and the 3/4 npt f x f elbow with the 3/4 npt f x m elbow supplied with kit 24484, refer to instructions (form 40652) included with kit. Fig. 2 4 3 F 2a L B B B TI250A The lubricator meters oil into the moving air stream to automatically lubricate air-operated motors. A manual adjustment in the housing (F), Fig. 2, sets the oil drip rate into the air stream, which can be monitored through a sight glass. One to two drops of oil per minute is common. Use an oil rated at 50 to 200 SUS (ISO grade 7 to 46) at 00F (38C), such as Graco motor oil, Part No. 202659. To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 4. To refill, unscrew the fill plug (L, Fig. 2) and pour in the oil. The lubricator s capacity is 7 oz. (0.2 liter). Check the oil level with the side sight glass. The lubricator can be refilled with the system pressurized. However, always relieve the system pressure before removing the bowl for any reason.

Pressure Relief Procedure INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tips.. Lock the gun trigger safety. 2. Close all bleed-type master air valves, including the bleed-type master air valve (4), supplied in your system. Fig. 2. 3. Turn the regulator T-handle all the way counterclockwise if you are removing the air filter/regulator () bowl, or servicing the air filter/regulator. 4. Open any fluid shutoff valves. 5. Unlock the gun trigger safety. 6. Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure. 7. Lock the gun trigger safety. Operation 8. Open any fluid drain valves (required in your system), having a container ready to catch the drainage. 9. Leave the drain valve(s) open until you are ready to spray again. If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose. Adjusting the Air Regulator. To increase the regulated air pressure, turn the T-handle clockwise. 2. To decrease the regulated air pressure, turn the T-handle counterclockwise. 3. To lock the regulator setting, tighten the jam nut. 4. Slowly open the air filter/regulator (), Fig.2. Use the filter/regulator to control pump speed and fluid pressure. Always use the lowest air pressure necessary to get the desired results. Higher pressures cause premature tip and pump wear. COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause component rupture and serious injury, never exceed the specified Maximum Incoming Air Pressure to the pump (see the Technical Data, on page 9).

Service Air Regulator Service Repair Kits are available. Refer to page 6. Every day, drain contaminants from the bowl before reaching the baffle level by opening the drain (D) at the bottom of the bowl (B). See Fig. 3. To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 4. Clean the air filter regularly to maximize filtering efficiency and to avoid excessive pressure drop. Fully relieve pressure to remove the bowl (B). Clean the filter element and bowl using household soap and water or denatured alcohol. Use compressed air to blow out the filter body. Blow the filter element out from the inside. If the regulator fails to operate, operates roughly, or vibrates, service it as follows. Inspect all parts for wear or damage. Replace damaged parts. Lubricate the bearing area, all o-rings, adjusting screw threads, and spring ends with no. 2 lithium-base grease. See. Fig. 3. Reassemble the regulator. Lubricator Service (Accessory) An accessory Lubricator Kit is available. Order Part No. 24484. Repair Kits are available (refer to page 7) for an accessory lubricator should you add one to the Air Control Kit. Clean the lubricator regularly to maximize efficiency. Fully relieve pressure and remove the lubricator from the air line. Disassemble the lubricator. Clean the parts with household soap and water or denatured alcohol. Wipe dry with a clean, soft cloth. Use compressed air to blow dirt and contaminants out of the lubricator body. Inspect all parts for wear or damage. Replace damaged parts. Clean the sight glass (S) thoroughly. See Fig. 4. Do not leave solvent residue in the sight glass as it may attack or weaken the glass. If the sight glass appears damaged, replace it immediately. Reassemble the lubricator.

Air Regulator Repair Kits Model 652 Air Regulator Shown Lubricate with no. 2 lithium-base grease. Regulator Repair Kit 6634 Regulator Repair Kit 6634, for Part No. 652 Air Filter/Regulator. Individual parts are not available separately. Bowl Replacement Kit 6672 for Part No. 652 Air Filter/Regulator and Part No. C034 Lubricator. Individual parts are not available separately. Note: this repair kit can be used for both the air regulator and the lubricator Bowl Replacement Kit 6672 Filter Element Kit 6635 Filter Element Kit 6635 for Part No. 652 Air Filter/Regulator. Individual parts are not available separately. Includes 40 micron filter. B Fig. 3 D TI25A Lubricator Repair Kits Sight Dome Repair Kit 6670. For Part No. C034 Lubricator. Individual parts are not available separately. Sight Dome Repair Kit 6670 Bowl Repair Kit 6672 for Part No. 652 Air Filter/Regulator and Part No. C034 Lubricator. Individual parts are not available separately. Note: this repair kit can be used for both the lubricator and the air regulator. Bowl Repair Kit 6672 S Fig. 4 TI252A

Air Control Parts Part No. 24479, Series A (includes items to 2 does not include Ref. No. 3) Ref. No. Part No. Description Qty. 5 2 652 AIR FILTER/REGULATOR; 0 3/4 npt(f) inlet and outlet; 5 25 psi (.03 0.86 MPa, 0.3 8.6 bar) pressure range; 40 micron polypropylene filter 2 UNION, swivel; 3/4 npt(m) x 3/4 npsm(f) 3 NIPPLE, pipe 3/4 npt x 4 in. 4 ELBOW, street, 45; /4 npt (m x f) 5 328 BALL VALVE, vented; 3/4 npt (m x f) 6 TEE, pipe /4 npt 7 0689 GAUGE, air pressure 3 TI222A 9 ELBOW, street, 90; 3/4 npt (f x f) 0 94545 CONNECTOR, bulkhead 9 NUT, keps, hex, 8mm 2 WASHER, lock 8mm 3* VALVE, safety relief 2 7 4 6 3* Part No. 244720, Series A (includes items to does not include Ref. No. 2) Ref. 4 0 2 No. Part No. Description Qty. 9 652 AIR FILTER/REGULATOR; 3/4 npt(f) inlet and outlet; 5 25 psi (.03 0.86 MPa, 0.3 8.6 bar) pressure range; 40 micron polypropylene filter 2 UNION, swivel; 3/4 npt(m) x 3/4 npsm(f) 3 ELBOW, street, 90 4 328 BALL VALVE, vented; 3/4 npt (m x f) 5 TEE, pipe /4 npt 6 ELBOW, street /4 npt (m x f) 7 0689 GAUGE, air pressure 9 94545 CONNECTOR, bulkhead 0 NUT, hex, 8mm WASHER, lock 8mm 2* VALVE, safety relief 3 TI220A 7 6 5 2* * not included in Air Control Kit Part No. 24479 or 244720. Replace with appropriate Part No. from table below according to pump ratio. Pump Ratio Part No. Description Pressure Relief 80: King 6643 Safety Relief Valve 90 psi 56: King 03347 Safety Relief Valve 00 psi 24: Bulldog 33: Bulldog 4: Bulldog 45: King 68: King 3498 Safety Relief Valve 0 psi

Lubricator Conversion Kit Parts Part No. 24484, Series A, (includes items to 3) Ref. No. Part No. Description Qty. C034 LUBRICATOR, Air 2 6522 AIR CONTROL, conversion kit (includes items 2a 2c) 2a ADAPTER 2b PINS, retaining 2 2c O RINGS 2 3 ELBOW, street, 90, 3/4 NPT (m x f) 2c 2a 2c 2b 2b TI250A 3

Technical Data Model 652 Air Regulator Category Maximum air input pressure Air inlet size Air outlet size Gauge port size (air regulator) Air filter element Maximum operating temperature Data 250 psi (.7 MPa, 7.2 bar) 3/4 npsm(f) 3/4 npt(f) /4 npt(f) 40 micron polypropylene screen 50C (22F) psi MPa bar 0.55 5.5 0.4 4. 0.28 2.8 0.4.4 MODEL 652 AIR REGULATOR FLOW CURVE scfm m/min.20 2.240 3.360 4.480 5.600 AIR FLOW AT INLET PRESSURE OF 00 PSI (0.7 MPa, 7 BAR), 3/4 port, and 40 micron element

The Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées. Graco Phone Number TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you: 800 367 4023 Toll Free 62 623 692 62 378 3505 Fax All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Sales Offices: Minneapolis, Detroit International Offices: Belgium, Korea, Hong Kong, Japan GRACO INC. P.O. BOX 44 MINNEAPOLIS, MN 55440 44 www.graco.com PRINTED IN USA 30934 June 200