Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel Electronics Gesellschaft mit beschränkter Haftung Prüflaboratorium August-Häusser-Straße 10, 74080 Heilbronn Tests in the fields: Electrical, mechanical and environmental simulation tests under inclusion of temperature, humidity, corrosion, IP degree of protection, vibration and mechanical shock as well as combinations thereof for the validation of connectors and other technical products Within the scope of accreditation marked with *), the testing laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, to use standards or equivalent testing methods listed here with different issue dates. Within the given testing field marked with #), the testing laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, the following: the free choice of standard or equivalent testing methods. The listed testing methods are exemplary. The testing laboratory maintains a current list of all testing methods within the flexible scope of accreditation. Connectors * DIN EN 60512-1- 1:2013-01 and measurements - Part1-1: General examination; Test1a: Visual examination (IEC60512-1-1:2002 This document is a translation. The definitive version is the original German annex to the accreditation certificate. 1/7
Connectors * DIN EN 60512-2- 1:2003-01 Connectors * DIN EN 60512-2- 2:2004-01 Connectors * DIN EN 60512-2- 6:2003-01 Connectors * DIN EN 60512-3- 1:2003-01 Connectors * DIN EN 60512-4- 1:2004-01 Connectors * DIN EN 60512-5- 1:2003-01 Connectors * DIN EN 60512-5- 2:2003-01- Connectors * DIN EN 60512-6- 3:2003-01 Connectors * DIN EN 60512-6- 4:2003-01 and measurements Part 2-1: Electrical continuity and contact resistance tests; Test 2a: Contact resistance; Millivolt level method (IEC 60512-2-1:2002) Connectors for electronic equipment- Tests and measurements- Part 2-2: Electrical continuity and contact resistance tests Test 2b: Contact resistance - Specified test current method (IEC 60512-2-2:2003) and measurements Part 2-6: Electrical continuity and contact resistance tests; Test 2f: Housing (shell) electrical continuity (IEC 60512-2-6:2002) and measurements Part 3-1: Insulation tests; Test 3a: Insulation resistance (IEC 60512-3-1:2002) and measurements Part 4-1: Voltage stress tests Test 4a: Voltage proof (IEC 60512-4-1:2003) and measurements Part 5-1: Currentcarrying capacity tests; Test 5a: Temperature rise (IEC 60512-5-1:2002); and measurements Part 5-2: Currentcarrying capacity tests; Test 5b: Currenttemperature derating (IEC 60512-5-2:2002) and measurements Part 6-3: Dynamic stress tests; Test 6c: Shock (IEC 60512-6- 3:2002) and measurements Part 6-4: Dynamic stress tests; Test 6d: Vibration (sinusoidal) (IEC 60512-6-4:2002) Period of validity: 2016-02-02 to 2021-02-01 - Translation - 2/7
Connectors * DIN EN 60512-6- 5:2003-01 Connectors * DIN EN 60512-9- 1:2010-12 Connectors * DIN EN 60512-9- 2:2012-09 Connectors * DIN EN 60512-9- 5:2010-12 Connectors * DIN EN 60512-10- 4:2004-06 Connectors * DIN EN 60512-11- 1:1999-08 Connectors * DIN EN 60512-13- 1:2006-11 Connectors * DIN EN 60512-13- 2:2006-11 Connectors * DIN EN 60512-13- 5:2006-11 and measurements Part 5-2: Currentcarrying capacity tests; Test 5b: Currenttemperature derating (IEC 60512-5-2:2002) and measurements- Part 9-1: Endurance tests Test 9a: Mechanical operation (IEC 60512-9-1:2010) and measurements Part 9-2: Endurance tests - Test 9b: Electrical load and temperature (IEC 60512-9-2:2011) and measurements Part -5: Endurance tests Test 9e: Current loading, cyclic (IEC 60512-9-5:2010) Connectors for electronic equipment- Tests and measurements Part 10-4: Impact tests (free components), static load tests and overload tests - endurance tests and overload tests Test 10d: Electrical overload (connectors) (IEC 60512-10-4:2003); Electromechanical components for electronic equipment - Basic testing procedures and measuring methods Part 11: Climatic tests; Section 1: Test 11a: Climatic sequence (IEC 60512-11-1:1995) and measurements Part 13-2: Mechanical operation tests Test 13b: Insertion and withdrawal forces (IEC 60512-13-2:2006 and measurements Part 13-2: Mechanical operation tests Test 13b: Insertion and withdrawal forces (IEC 60512-13-2:2006) and measurements Part 13-5: Mechanical operation tests Test 13e: Polarizing and keying method (IEC 60512-13-5:2006) Low pressure tests exempted Period of validity: 2016-02-02 to 2021-02-01 - Translation - 3/7
Connectors * DIN EN 61984:2009-11 Connectors * DIN EN 60352-2:2014-04 Connectors * DIN EN 60529:2014-09 Connectors- Safety requirements and tests (IEC 61984:2008) Solderless connections Part 2: Crimped connections - General requirements, test methods and practical guidance (IEC 60352-2:2006) Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989 + A1:1999 + A2:2013) Limited to: Protection against contact IP 1x up to IP4x Water tightness IPx7 and IPx8 Degree of protection * ISO 20653:2013-02 Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access Limited to: Protection against contact IP 1x up to IP4x Water tightness IPx7 and IPx8 Connectors Climatic Testing * VW 75174:2010-04 Motor vehicle connectors Test specification 31 DIN EN 60512-11- 14 DIN EN 60512-14-5 13 DIN EN 60512-15-6 DIN EN 60512-1-2 DIN EN 60512-1-3 DIN EN 60512-1-4 DIN 40050-9 Connectors Climatic Testing *# VW 75174-2:2008-01 Motor vehicle connectors - Slow-Motion Test Exempted Mixed flowing gastest ( MFG 4) Connectors Climatic Testing *# VW 60330:2013-12 Crimped connections Solderless electrical connections Exempted DIN EN 60512-16-8 Period of validity: 2016-02-02 to 2021-02-01 - Translation - 4/7
Corrosion*# 1:2008-01 2:2008-05 6:2008-10 11:2000-02 14:2010-04 27:2010-02 30:2006-06 38:2010-06 52:1996-10 61:1993-12 64:2009-04 78:2014-02 DIN EN ISO 9227:2012-09 testing Part 2-1: Tests Test A: Cold (IEC 60068-2-1:2007) testing Part 2-2: Tests Test B: Dry heat (IEC 60068-2-2:2007) testing- Part 2-6: Tests - Test Fc: Vibration (sinusoidal) (IEC 60068-2-6:2007) testing Part 2: Tests; test Ka: Salt mist (IEC 60068-2-11:1981) testing Part 2-14: Tests Test N: Change of temperature (IEC 60068-2-14:2009) testing Part 2-27: Tests Test Ea and guidance: Shock (IEC 60068-2-27:2008) testing Part 2-30: Tests Test Db: Damp heat, cyclic (12h + 12h cycle) (IEC 60068-2- 30:2005) testing Part 2-38: Tests Test Z/AD: Composite temperature/humidity cyclic test (IEC 60068-2-38:2009) testing Part 2: Tests, Test Kb: Salt mist, cyclic (sodium chloride solution) (IEC 60068-2-52:1996) testing; part 2: test methods; test Z/ABDM: climatic sequence (IEC 60068-2-61:1991) testing Part 2-64: Tests Test Fh: Vibration, broadband random and guidance (IEC 60068-2-64:2008); testing Part 2-78: Tests - Test Cab: Damp heat, steady state (IEC 60068-2-78:2012) Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2012) Corrosion*# ASTM B 117:2011 Standard Practice for Operating Salt Spray (Fog) Apparatus Corrosion*# DIN EN ISO 6270-2:2005-09 Paints and varnishes - Determination of resistance to humidity Part 2: Procedure for exposing test specimens in condensation-water atmospheres (ISO 6270-2:2005); Low pressure tests exempted Only NSS Only NSS Period of validity: 2016-02-02 to 2021-02-01 - Translation - 5/7
Type of testing testing area / value range Measurement uncertainty limit deviation example standard Heat / Cold # -70 C up to +180 C - ±2 K 1 2 Temperature Change # -70 C up to +180 C - ±2 K 14 Nb Temperature Shock # 70 C up to +180 C - ±2 K 14 Na Temperature # 70 C up to +180 C ±0,25 K - - Humidity # 10 % up to 100 % RH ±3% RH 78 DIN EN ISO 6270-2 CHT Temperature Humidity cyclic # 10 % up to 100 % RH ±3% RH 38 DIN EN ISO 6270-2 AT / AHT Humidity # 95 % RH ±2% RH at 25 C up to 55 C - IPX7 / IPX8 Immersion test # at ambient temperature up to 25 m DIN EN 60529 ISO 20653 Pressure # up to 4 bar ±0,005 bar IP1X to IP4X Test probe # Test Force: ±10 % DIN EN 60529 ISO 20653 Vibration Sinusoidal / Frequency range # 5 Hz up to 2.000 Hz Frequency: ±1 Hz from 5 Hz up to 50 Hz; ±2 % over 50 Hz Acceleration reference point: ±15 % 6 Random Vibration / Frequency range # 5 Hz up to 2.000 Hz ±10 % grms 64 Period of validity: 2016-02-02 to 2021-02-01 - Translation - 6/7
Type of testing testing area / value range Measurement uncertainty limit deviation example standard Mechanical Shock # Combined Vibration & Temperature # Acceleration: 5 g up to 50 g Shock duration: 2 ms up to 30 ms -50 C up to +150 C ±15 % m/s 27 ±2 K Frequency # 2 Hz up to 5.000 Hz ±2 % Acceleration # 0,1 m/s² up to 1.000 m/s² ±5 % Salt spray test # Condensation water atmosphere CH, AHT, AT # Ambient temperature (+5 K) up to +50 C Ambient temperature (+5 K) up to +42 C ±2 K DIN EN ISO 9227 11 52 ±3 K DIN EN ISO 6270-2 Visual inspection # Magnification ratio 8X up to 1000X Stereo DIN EN 60512-1-1 Contact interruption # 1 µs, 10 µs Time: ±10 % DIN EN 60512-2-5 Temperature rise # Current: 1 A up to 1000 A Temperature: 20 C up to 250 C Temperature: ±0,25 K Current: ±1 % DIN EN 60512-5-1 DIN EN 60512-5-2 DIN EN 60512-10-4 Force, pull and push # 1 N up to 100 kn ±0,5 % DIN EN 60512-13-1 DIN EN 60512-13-2 Heat / Cold # -70 C up to +180 C - ±2 K 1 2 Period of validity: 2016-02-02 to 2021-02-01 - Translation - 7/7