Installation manual. Excellent efficiency The best characteristics Attractive design. Solartechnik Prüfung Forschung

Similar documents
SOLAR COLLECTORS. Excellent efficiency, the best characteristics, high quality. The highest efficiency. More power.

U Q He y ys. UniPlate. Solar Collectors

Installation and Operation Manual for a Solar System with KPW Collectors

Installation and Operation Manual for a Solar System with KPC1-BP Collectors

for Solar Systems with KTU R Collectors

For our present, For their future. Version 11.03

Powertech/Apricus TM AP Solar Collector Specifications

GASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5

MANUAL. Collector FK7300. Mounting parallel roof bracket attachment system

Product Catalog Evacuated tube collectors CPC OEM CPC w OEM

Manual CPK 7210 N. Flate plate collector. Mounting parallel bench srew mountingsystem x x x x / version

DS Series Solar System

Version For our present, For their future.

SPLIT SOLAR HEATER SWSP-200 SWSP-300

Technical Product Submittal

Solar System with KPG1-ALC Collectors

INSTALLATION MANUAL THE / MODULE. IEC & UL version

Safety and Installation Instructions

SOLAR-LUX 6/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR ROOF MOUNTING INSTALLATION UK/IE (2011/05) GB/IE

INSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

SOLAR COLLECTORS. Werner Weiss. AEE - Institute for Sustainable Technologies (AEE INTEC) A-8200 Gleisdorf, Feldgasse 19 AUSTRIA

Solar Collector Product Specifications

Fact Sheet Sky CPC 58

OPERATION AND INSTALLATION

OPERATION AND INSTALLATION

INSTALLATION MANUAL MODULE TSM-PDG5/PDG5(C) TSM-PEG5/PEG5(C) TSM-PEG40 THE. UL version IEC version. TSM_UL/IEC_IM_Dec_2014_RevB - 1 -

Solar System with KPH1 ALP Collectors

Nanometrics Solar Power System

TRIC A On-Roof Installation for EURO- Collectors*

Schüco Premium Collectors Outstanding quality, performance and design

SOLAR THERMAL Forced circulation solar thermal system with selective flat plate collectors SELECTIVE SLIM

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

Detailed Assembly Instructions. ATS Evacuated Tube - Solar Panel Units ATS10 / ATS20 / ATS30

SOLAR-LUX 6/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR FLAT ROOF INSTALLATION (30, 45 ) WALL INSTALLATION (45, 60, 90 )

Photovoltaic Module User Manual

Photovoltaic Modules Installation Manual for Australia

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Assembly instructions

Solar System with KPS11-ALP Collectors

HP-30SC Solar Collector Evacuated Tube. Installation Manual Heat Transfer Products, Inc.

INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS

ES1V2.0, ES1V2.65, ES2V/2.0 AL, EM2V/2.0, ES2V/2.65, ES2H/2.65

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

Solar Electric Modules

SOLAR-LIFESTYLE INSTALLATION AND MAINTENANCE INSTRUCTIONS FLAT-PLATE COLLECTOR FLAT ROOF AND WALL-MOUNTED INSTALLATION (2011/05) UK

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

VIESMANN. Installation instructions VITOSOL 200-T. for contractors. Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Crystalline Silicon PV Module Installation Guide (JET)

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

Non-Imaging Concentrator based Solar System Operations & Maintenance Manual

INSTALLATION MANUAL.

INSTALLATION & OPERATION MANUAL

Solar System with KPS11 ALP Collectors

AUO Photovoltaic Module Installation Manual. Version 2.0

Installation Manual. Opal Solar QSA Series

INSTALLATION AND OPERATION MANUAL

Title Goes Here and Can Run Solar Photovoltaic up to 3 lines as shown here Systems as you see

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

FKB-1 / FKC /200/300 l system. Thermosiphon for flat roofs and rooftops. Installation instructions (2010/06) GR

GUIDANCE NOTES. Solar Collectors. On-Roof Installation (First Fix) Please leave these instructions with the User. Baxi Heating UK Ltd 2012

MAZDON. Table of Contents. Cautions. MAZDON Collector Tube Figure 1 Figure 2

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

05/14. OPC 360 Vacuum Tube Collector Planning/Installation/ Commissioning

SOLAR HEATING SYSTEM

SWIMMING POOL SOLAR HEATING SYSTEMS INSTALLATION MANUAL FOR AQUASOL SOLAR COLLECTORS

Installation Instructions. Vitosol 100. Vitosol 100 Type w 2.5 Flat collector for flat roofs and freestanding installation Part No.

AP Solar Collector Installation and Operation Manual. International Edition Rev. 1.5 (Sept 2005)

SDHW System Inspection Form

548 hydraulic separator

available in battery up to 4 units for a total of 560 kw

Operations and Assembly Manual

Test Report: KTB Nr k. Mechanical load test up to 2400 Pa according to EN :2002. for: IFF Kollmannsberger KG

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

SOLAR WORLD, INC. INSTALLATION MANUAL

Models DTT-84, DTT-94

The appropriate support systems for each SUNSYSTEM product. Robust and safe. Even weight distribution. Diversity of supports

SUNRAIN SOLAR HEAT PIPE COLLECTOR TZ58/1800- R SERIES

Solar module user manual Conergy PM 225P-250P

Installation instructions

Installation instructions

Installation, operating and maintenance instructions

INSTALLATION MANUAL. The Solution in Black The Quadmax Solution Honey M The Aesthetic Solution The Comax Solution

Replace - A - Top Installation Instructions

December 2017 ETC SOLAR COLLECTOR. Installation & Operation Manual Apricus Solar Co., Ltd

Results of annual simulation

Evacuated tube collectors

Renewables Installation Manual

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

INSTALLATION MANUAL FOR AQUATHERM INDUSTRIES SOLAR COLLECTORS USING STAINLESS STEEL MOUNTING HARDWARE

G500REC Manual Covering System for Containers

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

Summary of EN Test Results, Licence Number 011-7S660 R annex to Solar KEYMARK Certificate Issued

AEROWINGS Sun Control Systems

November 2015 ETC SOLAR COLLECTOR. Installation & Operation Manual. (North America)

INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL

Transcription:

Installation manual Excellent efficiency The best characteristics Attractive design SOLAR COLLECTORS The Quality Chooses Quality Solartechnik Prüfung Forschung 1

CONTENTS Remarks... 3 Technical specifications... 4-7 Safety instructions... 8 Installation instructions... 8-9 Description and packaging... 10-11 Filling and testing... 12-13 Fixing and mounting... 14-21 Termosiphon systems... 22-24 Facade mounting... 25 Connections... 26-27 Collector array layout... 28-29 Installation schemes... 30 Garantee... 31 2

REMARKS! A solar collector generates heat from sunlight and all other types of light. This leads to collector connectors getting! Neither drop the collector nor anything onto the collector. very hot, even when they are not filled. This creates a risk of burning. Cover the collectors with opaque material until the installation has been completed. It is recommended you leave the collector inside its packaging until it is installed.! Never step onto or stand on the collector.! Never install any shut-off valves in the line between the collectors and the safety valve. The safety valve responds at 87 PSI pressure.! Never leave the collector unsupported or unsecured. The glass could break if the collector falls over.! Never set the Solar loop presure lower then potable pressure.! All sensor wiring needs to be rated for expected temperatures. All sensor wiring needs to be protected from degradation and false signals. 3

SELECTIVE SOLAR COLLECTOR TYPE ESK 2.5 - SB Solartechnik Prüfung Forschung Technical characteristics: copper absorber with Eta plus selective foil 0.2 mm, corrugated low iron tempered glass, 4 mm thick dimensions 2149 x 1159 x 90 mm SELECTIVE SOLAR COLLECTOR TYPE ESK 2.5 - SB U Technical characteristics: copper absorber with Eta plus selective foil 0.2 mm, corrugated low iron tempered glass, 4 mm thick dimensions 2149 x 1159 x 90 mm 4

years 10 warranty Tip ESK 2.5 SB ESK 2.5 SB - U Gross area (m 2 ) 2,49 2,49 Light entering area (m 2 ) 2,35 2,35 Absorber surface (corrugate) (m 2 ) 2,32 2,32 Absorber material copper sheet with "Eta plus" selectiv surface coating Absorption coefficient (Eta plus) (%) 95 ± 2 95 ± 2 Emission coefficient (Eta plus) (%) 5 ± 2 5 ± 2 Cu Pipe register frame (mm) Ф 8 x 0,5 Ф 8 x 0,5 Collective Cu pipe frame (mm) Ф 22 x 0,8 Ф 22 x 0,8 Absorber volume (l) 1,7 1,7 Transparent front cover 4mm Hecker T-Safe Solarfloat tempered solar glass Solar light transmission through glass (%) 92 ± 2 92 ± 2 Solar energy transmission through glass (%) 91 ± 2 91 ± 2 Number of connections 4 2 Connection diameter (R) Ф 22 Ф 22 Max. working / test pressure (bar) 10 / 14 Stagnation temperature ( o C) 199 Insulation - back side 40 mm glass wool (50kg/m 3 ) Insulation - on the sides - Back area 0.5 mm embossed aluminium sheet Collector construction aluminium profil AlMgSi 0,5 F22 Welding method ultrasonic Height (mm) 2149 2149 Width (mm) 1159 1159 Depth (mm) 90 90 Weight (kg) 44 44 Collector efficiency Pressure drop 1.0 Collector efficiency for G = 800 W/m 2 1400 Pressure drop in Pa 0.9 0.8 Absorber Aperture Gross 1200 20 C 0.7 1000 0.6 800 0.5 0.4 600 0.3 400 0.2 0.1 200 0.0 0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 T m* [Km 2 /W] Reference area Absorber area Aperture area Gross area η0 (-) 0.766 0.754 0.708 a1 (W/m²K) 4.52 4.45 4.18 a2 (W/m²K²) 0.0042 0.0041 0.0039 0 0 50 100 150 200 250 300 350 400 Flowrate [l/h] Flow [l/h] 0 80 160 240 320 400 rate Pressure drop [Pa] 0 155 352 593 877 1203 5

SELECTIVE SOLAR COLLECTOR TYPE ESK 2.5 - SB T Technical characteristics: copper absorber with Eta plus selective foil 0.2 mm, corrugated low iron tempered glass, 9mm filled with argon, 2 x 4 mm thick dimensions 2149 x 1159 x 102 mm SELECTIVE SOLAR COLLECTOR TYPE ESK 2.5 - SB TU Technical characteristics: copper absorber with Eta plus selective foil 0.2 mm, corrugated low iron tempered glass, 9mm filled with argon, 2 x 4 mm thick dimensions 2149 x 1159 x 102 mm 6

years 10 warranty Tip ESK 2.5 SB T ESK 2.5 SB - TU Gross area (m 2 ) 2,49 2,49 Light entering area (m 2 ) 2,22 2,22 Absorber surface (corrugate) (m 2 ) 2,20 2,20 Absorber material copper sheet with "Eta plus" selectiv surface coating Absorption coefficient (Eta plus) (%) 95 ± 2 95 ± 2 Emission coefficient (Eta plus) (%) 5 ± 2 5 ± 2 Cu Pipe register frame (mm) Ф 8 x 0,5 Ф 8 x 0,5 Collective Cu pipe frame (mm) Ф 22 x 0,8 Ф 22 x 0,8 Absorber volume (l) 1,7 1,7 Transparent front cover 2 x 4mm tempered solar glass with 9 mm space gap, filled up with argon Solar light transmission through glass (%) 96 ± 2 96 ± 2 Solar energy transmission through glass (%) 95 ± 2 95 ± 2 Number of connections 4 2 Connection diameter (R) Ф 22 Ф 22 Max. working / test pressure Stagnation temperature Insulation - back side Insulation - on the sides Back area Collector construction Welding method (bar) ( o C) 10 / 14 236 12 mm elastomeric rubber foam / 40 mm glass wool (50kg/m 3 ) 12 mm elastomeric rubber foam / 10 mm glass wool (50kg/m 3 ) 0.5 mm embossed aluminium sheet aluminium profil AlMgSi 0,5 F22 ultrasonic Height (mm) 2149 2149 Width (mm) 1159 1159 Depth (mm) 102 102 Weight (kg) 70 70 Efficiency ( %) 90 80 70 60 50 40 30 20 10 0 Collector efficiency 5 10 20 30 40 50 60 70 80 90 100 Ta-Tm Collector efficiency η0 = 0,8 a1 = 3,175 W/(m²K) a2 = 0,01 W/(m²K²) Δp (kpa) Pressure drop 0,4 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 0 0,02 0,04 0,06 0,08 0,1 0,12 Flow (kg/s) Pressure drop 7

SAFETY INSTRUCTIONS Installation & Transportation Solar Collectors must be secured during transportation. You must secure the collectors from falling out of the packaging, and from scratching each other. Use of a carrying strap is recommended Do not lift the collector by the connection ports or header tube Avoid impacts & vibration on the collectors as much as possible Please lift collector by lifting lugs (if included) On Roof Operation Please follow the following safety & operational guidelines when installing Solar Collectors Included Mounting Hardware(2 x antislip protection and 4 x side bracket) is intended for On Roof Installations Only Additional Mounting Hardware is needed for Pitched Roof & Tilt Mount Installations You will be intervening in existing roof and roof coverings during installation Please ensure that proper measures are taken for protection of all installation crew Familiarize yourself with local laws & regulations, and follow them carefully! Important Note - Solar Collectors should not be filled when the sun is out because scalding can occur due to steam being released from the system. If you must fill the Solar Collectors during sunny periods, please cover the collectors. Lightning Protection Solar Collectors should be electrically connected to each other, and to the building s Earth ground via the shortest possible route. An authorized lightning protection specialist should be consulted to examine the installation and installation site. INSTALLATION INSTRUCTIONS Collector Layout, Orientation, and Siting Place the collector where it will receive the maximum amount of sunlight available in your location. Euroterm ESK 2.5 SB collectors may be installed on a roof, against a south facing wall, or on the ground. 8

INSTALLATION INSTRUCTIONS Orientation Orientation and tilt are critical to performance. The Euroterm ESK 2.5 SB collectors should be oriented (faced) as close to true south as practical, although they may be faced as much as 20 east or west of true south with less than 5% loss in capacity. Shading Trees, chimneys, dormers, other buildings, new construction, and even fences may shade the collector array, especially in the winter when sun angles are low and shadows are long. Be sure the collectors are placed where they will be not shaded by these obstructions. As a rule, no more than 5% of the collector area should be shaded between the hours of 9:00 a.m. and 3:00 p.m. To avoid shading by collectors on each other, the front to front dimension must be 2.5 times the highest point of the front collector. Angle of Inclination or Tilt Angle For domestic water, use an optimum tilt of the site s latitude plus 5, although the slope may be 10 greater or less with a capacity loss of under 5% for the system. For a solar space heating system, a steeper tilt angle is important for optimal winter performance. The steeper tilt will favor winter system operations when the sun is low in the sky. Therefore, for space heating systems chose a tilt of latitude plus 15. The variation of 10 either way will not seriously affect the total annual performance of the system, all other things being equal. Shedding Snow A tilt angle of 50 or more is necessary in regions of heavy snowfall and accumulation. Tilt angles of 50 and above will shed snow from OVSOL evacuated tube collectors even after severe storms. It is critical in heavy snow areas that the collectors be sloped to at least a 50 tilt angle. If collectors are installed on a flat roof in an area which receives heavy snowfalls, the lower end of the units should be at least 40 cm above the roof level to minimize chances of snow build-up on the bottom end of the collectors. Wind & Snow Load The wind and snow loads for your location should be taken into account when installing a Euroterm ESK 2.5 SB Flat Plate Solar Collector and calculating the overall weight-carrying capacity of the roof. Euroterm ESK 2.5 SB Flat Plate Solar Collector Mounting Hardware is designed for: 1.2 kn/m 2 (snow load) 1.1 kn/m 2 (wind load) Operation, Checks and Maintenance The solar system offers unmanned and almost maintenance-free operation. Despite that, it is important to check the right functioning of the system within the first days of operation. First of all the temperature, system pressure and pump operation shall be checked. Once a year, preferably during a sunny day, it is necessary to check the working order and tight fixing of the collectors, verify the system tightness and pressure (incl. pressure in the expansion vessel) and the pump operation. At least once in every 2 years the heat carrying fluid shall be checked for its antifrost properties. The system shall be always replenished with the same fluid as the original filling was. 9

Solartechnik Prüfung Forschung DESCRIPTION Euroterm Flat-plate solar collector TYPE: ESK 2.5 SB, is composed of aluminum housing in which is attached a selective copper plate for collecting heat. In one piece placed selective absorber - full plate, is processed in a latest technology Bluetec ETA Plus, which provides a very high efficiency of the collector. Selective solar absorber is ultrasonically welded to the 12 copper pipes. The upper side of each panel is tempered solar glass, with low content of iron oxide and high coefficient of energy transfer. Glass wool insulation with density of 50 kg/m3 is placed at the bottom of the collector. Temperature sensor should be placed in a specially designed pocket (A) near the upper collector pipe. System installation is simple, and if it is performed correctly, ensures long and efficient operation. A IDENTIFICATION For identification of the solar collector is used table: Solartechnik Prüfung Forschung 10

PACKAGING Solar collectors can be delivered in diffrent packaging depending of the quantity: 1. One collector - collector - installation manual with garantee included 2. Packaging in 14 pcs. - max 14 collector - installation manual with garantee included 11

FILLING PREPARATION OF MIXTURE OF WATER + glycol Glycol is supplied separately in the standard package and mixed with water in the tank before filling the installations (for example. 40% glycol and 60% water-resistant to frost temperatures from -21 C). Fill the solar system exclusively with propylene glycol which is intended specifically for use in solar devices. Propylene glycol retains its properties in the area of -32 180 C. Propylene glycol is biologically compatible and not toxic. Do not fill pure glycol first and then add water. If the water contains a high level of chlorine is it necessary to use a distilled water. Antifreeze temperature Density 50% -32 C 1.045 kg/dm 3 40% -21 C 1.037 kg/dm 3 30% -13 C 1.029 kg/dm 2 FILLING 1 - Close the valve (A) 2 - The manual venting valve at the highest point (see drawing ) shall be open during charging (7) 3 - Insert antifreeze liquid into the system from the reservour with external pump (B) figure 1, until all air bladders are removed. Close the manual venting valve. 4 - Raise the pressure in the installation at 4 bar. 5 - Open the valve (A) and leave the installation to work about 20 minutes 6 - Repeat the procedure from point 2, while the air is completely dropped 7 - Adjust the pressure in the installation of 3 bar. 8 - Open the valve (A) and close venting valve, to prevent possible evaporation of heat transfer fluid. Do not fill the installation during full insolation and while collectors are hot.! Important: The system must not be replenished with water. 12

FILLING For larger solar thermal systems or in installations where are not used pump sets, connecting and charging the system are implemented in accordance with the following scheme. Note: To prevent the natural circulation should be used one of these three solutions: - check valves (recommendation - two, one on each line), - solenoid valves or - electromotor valves. FILLING 1 - Close the valve (A) 2 - The manual venting valve at the highest point (see drawing ) shall be open during charging (7) 3 - Insert antifreeze liquid into the system from the reservour with external pump (B) figure 1, until all air bladders are removed. Close the manual venting valve. 4 - Raise the pressure in the installation at 4 bar. 5 - Open the valve (A) and leave the installation to work about 20 minutes 6 - Repeat the procedure from point 2, while the air is completely dropped 7 - Adjust the pressure in the installation of 3 bar. 8 - Open the valve (A) and close venting valve, to prevent possible evaporation of heat transfer fluid. Note: In the charging process, EM valve needs to be open. Figure 1! Important: The system must not be replenished with water. 13

MOUNTING WITH METAL CONSTRUCTION PARALLEL MOUNTING WITH THE ROOF LINE Install four collector roof hooks by lag bolting feet into roof rafter. 1 2 5 4 Metal profile is set to the roof hooks. Fixing is done by M8x35 self drilling screw. Anti slip protection is placed on the lower profile for prevent sliding of the collectors during installation. - Attach the collector to the profile rail by using a collector side bracket and M8x35 self drilling screw. - Each collector has four mounting brackets. 5 3 14

MOUNTING WITH METAL CONSTRUCTION PARALLEL MOUNTING WITH THE ROOF LINE - installation set for the collectors 1. Roof hook 2. profile rail 3. collector side bracket * 4. antslip protection * 45 5. M8 x 35mm self drilling screw * included in standard package 2 1 3 4 5 3 2 4 1 4 - roof hook for mounting of the collector Install four collector roof hooks by lag bolting feet into roof rafter. dimension: length 300mm width 30 mm material steel thickness 5 mm 1 15

MOUNTING WITH GALVANIZED PROFILE PARALLEL MOUNTING WITH THE ROOF LINE Install four collector roof hooks by lag bolting feet into roof rafter. 1 2 4 Galvanized profile is set to the roof hooks. Fixing is done by M8x20 screw and M8 locknut (20x30mm) Anti slip protection is placed on the lower profile for prevent sliding of the collectors during installation. - Attach the collector to the galvanized profile rail by using a collector side bracket, a bolt and a bracket locknut. - Each collector has four mounting brackets. 5 3 6 16

MOUNTING WITH GALVANIZED PROFILE PARALLEL MOUNTING WITH THE ROOF LINE - installation set for the collectors 1. Roof hook 2. Galvanized profile rail 3. collector side bracket * 4. antslip protection * 45 5. M8 screw x 20mm 6. M8 locknut (20x30mm) * included in standard package 2 4 1 3 3 5 6 3 5 2 1 4 4 1 - roof hook for mounting of the collector Install four collector roof hooks by lag bolting feet into roof rafter. dimension: length 300mm width 30 mm material steel thickness 5 mm 17

MOUNTING WITH UNIVERSAL AL PROFILE PARALLEL MOUNTING WITH THE ROOF LINE The base plate - Tray 1 (art. 50 206), is mounted on the roof beam using the M8 x 80 screws (art. 50 210). Base plate (Art. 50 206), is prepared so that it is always possible to use at least three screws. Carrier Profile - Tray 2 (art. 50 207), is placed on the basic plate - Tray 1 (art. 50 206). Grooved carrier profile and the base plate, allows removal of steps, such as height adjustment of the screw, and thus shortens the time of installation, as well as number of hours of the installer on the roof. Using self-locking screw M10 x 20 (art. 50.210) angular profile is associated with the carrier profile - Tray 2 (art.50 207). Angular profile (art. 50 203), is an important element in universal mounting system. It is used in cross-mounting and it is connecting element between the universal profile (art. 50 100) and roof hooks - Tray 2 (art. 50 207). Universal profile (art. 50 100), is set to the angle profiles (art. 50 203). Fixing is done with self - locking screw M10 x 20 (art. 50 210) and screw channels. Screw channels are designed so that the screw can be tightened with torque of 17 Nm. 18

MOUNTING WITH UNIVERSAL AL PROFILE PARALLEL MOUNTING WITH THE ROOF LINE Anti slip protection - stainless steel shafts (art. 50 215), is placed on the lower profile for prevent sliding of the collectors during installation. Attaching the solar collector on a universal platform is performed using side brackets (art. 50 211). 19

MOUNTING WITH UNIVERSAL AL PROFILE FREE STANDING MOUNTING On the already mounted base plate - Tray 1 (art. 50 206) and carrier profile - Tray 2 (art. 50 207), we placed the angle profile (art. 50 203) rotated for 90 degrees, using self - locking screw M10 x 20 (art. 50 210). Universal profiles (art. 50 100), using self-locking screw M10 x 20 (art. 50 210) and screw channels are placed on angular profile (art. 50 203), parallel to the roof beams. With angular panels - 90o (art. 50 205), universal mounting platform is adapted for mounting under a certain angle. Achieving the desired angle is allowed by using variable angular plates (art. 50 204). Universal profiles with self-locking screw M10 x 20 (art. 50 210) and screw channels are placed on the corner plates (art. 50 205) and (art. 50 204). 20

MOUNTING WITH UNIVERSAL AL PROFILE FREE STANDING MOUNTING The angular profiles (art. 50 203) are placed on the universal profiles (art. 50 100), using self - locking screw M10 x 20 (art. 50 210) and screw channels. On the angular profile (art. 50 203), which is rotated for 90 degrees, universal profiles (art. 50 100) are set normal to the roof beams. On the lower profile of an already mounted, universal platform, is placed antislip protection - stainless steel shafts (art. 50 215), for prevent sliding of the collectors during installation. Attaching the solar collector on a universal platform is performed as well as in the parallel mounting with the roof line. 21

MOUNTING TERMOSIPHON SYSTEM Termosiphon system ESK 2.5 150 H and ESK 2.5 300 H represents a simple installation for preparation of sanitary hot water. The system consists of the following elements: - Solar collector ESK 2.5 SB selective - Water heater - 150 or 300 litres - Stand for collectors and boiler Preparing for installation Before starting the installation of solar thermal system please check following: - Completeness and integrity of supply - Performance of the roof to allow installation on wooden construction. - The orientation of solar collectors (south). - Avoid shadows caused by trees, chimneys, etc. - The stability of the surface intended for installation of the system. Use only spare parts from the original manufacturer. Remediation of roof to provide hermetic sealing to perform professional team, especially in the field of waterproofing and bituminous layers. To ensure a minimum distance before you start mounting: - At least one meter between the construction and the edges of the roof 22

MOUNTING TERMOSIPHON SYSTEM SYSTEM DIMENSIONS ESK 2.5 150 H ESK 2.5 300 H FILLING TERMOSIPHON SYSTEM 1. With the container filled with a mixture of water and glycol, fill the system by opening the intended (1) for setting the safety valve. 2. Stop filling when fluid begins to drain from the second hole which is used for mounting the mini valve. 3. Close the mini valve (2), and set the safety valve on the intend (1). 23

MOUNTING TERMOSIPHON SYSTEM Mounting system (45 ) For complete installation of the system needs at least two people. The system is installed following the instructions provided with this tutorial. Supporting structure is mounted as shown on drawing Sets the boiler on the construction using special brackets placed on it or on the special holders that comes with ESK 2.5 SB 300H kit ESK 2.5 SB 150H ESK 2.5 SB 300H 24

FACADE MOUNTING use four antislip protection bracket rain protection profile 25

CONNECTING COLLECTORS EUROTERM solar thermal collectors are interconnected throught 22 mm common joints. Straight and corrugated stainless steel joints are recommended. - Hold firmly with the size 24 spanner and tighten the union nut onto the cutting connection with the size 27 spanner. - Avoid applying extra torsion on the Header as you install the connectors. Always use a spanner to fix the header and then install the connectors. 26

CONNECTING COLLECTORS Solar thermal collectors can also be interconnected by brazing (not recommended by the manufacturer) - Use oxyacetylene to weld common joints to the Cu pipe. - Mix a flux with water to make a paste and paint the surfaces to be welded. - Use wet piece of fabric to protect the plastic joint parts from flame. PIPE CONNECTIONS Number of collectors Flow Dimension of pipe / l/min mm 1 2 15 x 0.7 2 4 18 x 0.7 3 6 18 x 0.7 4 8 22 x 0.8 5 10 22 x 0.8 6 12 22 x 0.8 7 14 28 x 0.8 8 16 28 x 0.8 27

COLLECTOR ARRAY LAYOUT Collector field measurement (after distance 900 mm) Collector dimensions: 2149x1159x90 (all specified dimensions in mm) Weight: 45 kg 1200 4812 Roof rafter max 1700 The base plate and carrier profile (Tray 1 and 2) Universal profile 900 150 900 900 900 900 900 156 2404 6016 max 1700 900 900 302 900 900 900 900 900 900 308 3608 max 1700 max 1700 max 1700 7220 max 1700 900 900 900 454 900 900 900 900 900 900 900 460 28

COLLECTOR ARRAY LAYOUT Type ESK 2.5 - SB / ESK 2.5 - SB T Type ESK 2.5 - SB U / ESK 2.5 - SB TU Max. 6 collectors in line! During parallel connecting of two or more collectors fields, pay attention about equal flow (TICHELMAN SYSTEM). Unequal flow may occur disbalance of the system. When connecting collectors in series, use the compensation joints on evry second collectors, and in termpon version for each collector. Connecting for more then 6 collectors in line are performed in consultation with the manufacturer. 29

INSTALLATION SCHEMES Basic installation scheme with collector for DHW Installation scheme with collectors and additional heating source for DHW 1 1 P T T 2 2 A 3 3 6 Installation Installation scheme for DHW scheme for DHW and using collectors and using collectors to support to support heating system 1 heating system 1 2 2 8 5 7 5 4 3 4 3 7 LEGEND 1. Solar Collectors 5. Floor heating 2. Pump set 6. Boiler 3. Water tank 7. Chiller - Heat pump 4. Radiator 8. Fireplace DHW - domestic hot water production 30

GARANTEE All products are guaranteed by EUROTERM to be free of manufacturing defects since acceptance by the buyer according to following terms and conditions. Guarantee period: EUROTERM GUARANTEE PERIOD: 10 years after the date of acceptance by the buyer. Within that period, any repair or incidence will be repaired free of charge by EUROTERM to the buyer, but those expenses when unreasonable return occurs. This guarantee period is only applicable for EUROTERM trademark solar collectors. Any damage caused by abuse, inappropriate installation, inappropriate electrical protection, energy or combustion, corrosion caused by heat producers, incidences caused by an inadequate working of security elements, drillings caused by frosts and any other agent different to EUROTERM are not included in guarantee period. For any assistance during guarantee period, buyer must send to EUROTERM a copy of the warranty document filled and sealed. Guarantee exclusions: EUROTERM shall not be obliged to repair any damage if: - Solar collector has not been installed according to procedures described in this manual. - Warranty document has not been sealed by EUROTERM. - If products have been manipulated by operators who have not been authorized by EUROTERM - Spare parts not endorsed by EUROTERM have been used. - The guarantee does not cover damages caused by freezing of the solar fluid. Guarantee covers any manufacturing fault in products sold by EUROTERM. These products will be repaired or replaced in EUROTERM warehouse or in a different one authorized by EUROTERM. Therefore, guarantee does not include working or installation faults. Guarantee does not cover natural attrition or any breakdown caused by an inappropriate storage, negligence, overcharge or any other reason different to manufacturing faults. For correct functioning of the solar thermal system, the instaler need to comply with the manners and instruction for onstallation and connection of the collector discribed in this manual, and detaild in the instruction on our web site in the section of the technical support. EUROTERM shall not accept any penalty and shall not be liable for any damage to the buyer or to a third party due to abuse. 31

www.euroterm.com.mk GARANTEE Type ESK 2.5 SB Serial number Garantee 10 years Manufacturing date Signature 32 Euroterm d.o.o. Lece Koteski 50 Industrial area - Biljana Prilep, R. Macedonia tel. +389 48 419 415 fax +389 48 422 981 e-mail: info@euroterm.com.mk