Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Similar documents
Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

The insulation tester must only be used by a skilled and competent measuring equipment connected directly to utilization points

i400s Calibration Information Introduction

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Users Manual. Phase Rotation Indicator

PY-11 Voltage & Continuity Tester

233 True-rms Remote Display Digital Multimeter Safety Information

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Go to to register your product and find more information.

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

362 Clamp Meter. Users Manual

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Tachometer. English. Users Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

323/324/325 Clamp Meter

HIGH VOLTAGE PROVING UNIT

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

SOIL RESISTIVITY TESTER

302+/303 Clamp Meter. Users Manual

80PK-2A Type K Immersion Probe

Infrared Thermocouple Probe

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

362 Clamp Meter. Users Manual

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

KMP Insulation-Continuity Tester. Users Manual

TIME-10 Process Control Stopwatch

P5510. Users Manual. Pneumatic Comparison Test Pump

Users Manual. MegOhmMeter

ANALOG INSULATION RESISTANCE TESTER

4-20mA DC PROCESS CLAMP METER

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

365 Detachable Jaw True-rms Clamp Meter

INSP-3 Wiring Inspection Tester

i3000s/i2000 Flex AC Current Probe

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

373 Clamp Meter. Users Manual

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Temperature Calibrator

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

DIGITAL EARTH RESISTANCE Model KM 2030

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Adjustable Steel Drum Dolly

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

HIGH VOLTAGE PROXIMITY DETECTOR

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

60 Watt Industrial LED Low Bay Light

Phase Sequence Tester


Low-Profile Drum Caddy

6-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

Air-Operated Waste Oil Drainer

712 RTD Calibrator. Instruction Sheet. Introduction

55-Gallon Drum Cradle

Heavy-Duty Sawhorse. Owner s Manual

4-Claw Log Lifting Tongs

1000-LB. ENGINE STAND

1000-Lb. Drum Truck. Owner s Manual

3-TON DOUBLE LOCKING JACK STANDS OWNER S MANUAL

KMP7010. Ground Resistance Tester. Users Manual

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

Dolly with Pneumatic Tires

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Visit us at

84in. Driveway Drag. Owner s Manual

Adjustable Shop Stool with Backrest

Flow Control Valve Instruction Manual

2000-LB. ENGINE STAND

Low Profile Creeper. Owner s Manual

Sawhorse with Chainsaw Holder

1500-lb Snowmobile Dollies

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S

16 Inch Hanging Pendant Barn Light

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Instruction Manual & Specification

Machinery Skate. Owner s Manual

IN120L / IN120LB / TM120L/TM120LB IN2400L

Hydraulic Drum Transporter

182-LED Solar-Powered Motion Security Light. Owner s Manual

Adjustable Steel Welding Table

VICE MOUNTED BEAD ROLLER

Transcription:

Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital Multimeters Labels Microwave Leakage Detectors Motor Maintenance Equipment Multifunction Testers Non-trip Loop Testers Pat Testers & Accessories Phase Rotation Testers Proving Units Socket Testers Thermometers & Probes Test Leads Voltage Indicators Specialist Metrohm Testers (4 & 5kV) Specialist Drummond Testers PC104/PC105 3-PHASE SOCKET TESTER Instruction Manual Martindale Electric Company Limited Metrohm House, Penfold Trading Estate, Imperial Way, Watford WD24 4YY, UK Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900 E-mail: sales@martindale-electric.co.uk Website: www.martindale-electric.co.uk 2012 Martindale Electric Company Ltd. Registered in England No. 3387451. E. & O.E. Document Rev1 LITPC104/105

GENERAL SAFETY INFORMATION: Always read before proceeding. These instructions contain both information and warnings that are necessary for the safe operation and maintenance of this product. It is recommended that you read the instructions carefully and ensure that the contents are fully understood. Failure to understand and to comply with the warnings and instructions can result in serious injury, damage or even death. Specifi cation PC104/PC105 3-Phase Socket Tester In order to avoid the danger of electrical shock, it is important that proper safety measures are taken when working with voltages exceeding 30V AC rms, 42V AC peak or 60V DC. This product must only be used by a competent person capable of interpreting the results under the conditions and for the purposes for which it has been constructed. Particular attention should be paid to the s, Precautions and Technical Specifications. Always check the unit is in good working order before use and that there are no signs of damage to it. Do not use if damaged. Where applicable other safety measures such as use of protective gloves, goggles etc. should be employed. Please keep these instructions for future reference. Updated instructions and product information are available at: www.martindale-electric.co.uk REMEMBER: SAFETY IS NO ACCIDENT MEANING OF SYMBOLS: 3 Equipment complies with relevant EU Directives End of life disposal of this equipment should be in accordance with relevant EU Directives Caution - risk of electric shock Caution - risk of danger & refer to instructions Equipment protected by double or reinforced insulation (Class II) Three-phase alternating current ELECTRICAL SPECIFICATIONS Input voltage range: 380V to 415V AC (Phase to Phase) Input frequency: 50Hz Input current: < 20mA GENERAL SPECIFICATIONS Power: From circuit under test Dimensions: 131(L) x 94(W) x 54(D) mm Weight: Approx 292g (without plug) Includes: Instructions SAFETY: Conforms to BS EN 61010-1, CAT III 300V Class II Double Insulation Pollution Degree: 2 EMC: Conforms to BS EN 61326-1

Since some jurisdictions do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any part of any provision of this warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision or other part of that provision. Nothing in this statement reduces your statutory rights. Thank you for buying one of our products. For safety and full understanding of its benefi ts please read this manual before use. Technical support is available from 01923 441717 and support@martindale-electric.co.uk. CONTENTS 1 Introduction 1 1.1 Inspection 1 1.2 Description 1 1.3 Accessories 1 2 Product Specific Safety Information 2 2.1 Precautions 2 3 Operation 4 3.1 Testing a 3-Phase Socket 4 3.2 Wiring Colour Coding 5 4 Maintenance 5 4.1 Cleaning 5 4.2 Repair & Service 5 4.3 Storage Conditions 6 5 Warranty 6 Specifications

1. INTRODUCTION 1.1 Inspection Examine the shipping carton for any sign of damage. Inspect the unit and any accessories for damage. If there is any damage then consult your distributor immediately. 1.2 Description The PC104 and PC105 are 3-phase socket testers intended to check CEE 4 & 5 pin, 16A, 32A & 63A sockets. The PC104 checks for phase presence, phase sequence and PE presence. The PC105 also checks for neutral presence. The table below shows the model number and the CEE socket type tested. Model No PC104/16 PC105/16 PC104/32 PC105/32 PC104/63 PC105/63 Socket Type Tested 16A/3P+E 16A/3P+N+E 32A/3P+E 32A/3P+N+E 63A/3P+E 63A/3P+N+E 1.3 Accessories (included) Instructions 4.3 Storage Conditions The instrument should be kept in warm dry conditions away from direct sources of heat or sunlight, and in such a manner as to preserve the working life of the unit. It is strongly advised that the unit is not kept in a tool box where other tools may damage it. 5. WARRANTY AND LIMITATION OF LIABILITY This Martindale product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is 2 years and begins on the date of receipt by the end user. This warranty extends only to the original buyer or enduser customer, and does not apply to fuses, disposable batteries, test leads or to any product which, in Martindale s opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation, handling or storage. Martindale authorised resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Martindale. Martindale s warranty obligation is limited, at Martindale s option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to Martindale within the warranty period. This warranty is the buyer s sole and exclusive remedy and is in lieu of all other warranties, expressed or implied, including but not limited to any implied warranty of merchantability or fi tness for a particular purpose. Martindale shall not be liable for any special, indirect, incidental or consequential damages or losses, including loss of data, arising from any cause or theory. 1 6

Note: The interchanging of the neutral wire (N) with the earth (PE) cannot be recognised by this device. Where a socket is found to have a wiring error, maintenance should only be carried out by a competent electrician who is familiar with the relevant regulations and the safety risks involved. 3.2 Wiring Colour Coding In April 2004 the colour coding of UK wiring was harmonised with the IEC wiring colour code. Table 2 shows the old UK colour code and the new IEC colour code. Earth Neutral Line 1 Line 2 Line 3 2. PRODUCT SPECIFIC SAFETY INFORMATION Measurement Category III (CAT III) is applicable to test and measuring equipment connected to the distribution part of the building s low-voltage MAINS installation. 2.1 Precautions This product has been designed with your safety in mind, but please pay attention to the following warnings and cautions before use. Before use check the unit for cracks or any other damage. Make sure the unit is free from dust, grease and moisture. Also check any associated leads and accessories for damage. Do not use if damaged. Old UK Colours New IEC Green/ Yellow Green/ Yellow Black Red Yellow Blue Blue Brown Black Grey Always verify the unit is functioning correctly on a known correctlywired live socket before and after use. Do not use the unit if the unit does not give the correct indications. 5 4. MAINTENANCE 4.1 Cleaning The unit may be cleaned using a soft dry cloth. Do not use moisture, abrasives, solvents, or detergents, which can be conductive. 4.2 Repair & Service There are no user serviceable parts in this unit other than those that may be described in section 3. Return to Martindale Electric if faulty. Our service department will quote promptly to repair any fault that occurs outside the guarantee period. Before the unit is returned, please ensure that you have checked the unit. The socket tester does not test whether the earth is voltage-free. Before using the socket tester, test by other means that the earth contacts are voltage-free. If there is voltage on the earth, switch off immediately (disconnect at the fuse). The socket tester must not be used in this case. The socket tester is not intended to determine if circuits being tested are dead. The correct testing methods should be used to do this. If the indicators do not illuminate, this does not necessarily mean all three phases under test are dead. Two phases and the earth/neutral could be open circuit, but one phase could still be live. 2

Caution Avoid severe mechanical shock or vibration and extreme temperature. 3. OPERATION 3.1 Testing a 3-Phase Socket Plug the PC104/PC105 into the socket to be tested and refer to the table below, or the front decal of the unit, to determine the wiring condition of the socket under test. PC104 Indication PC105 Indication Wiring Condition Socket is wired correctly. Phase sequence is L1, L2, L3. PE & Neutral are present. L1, L2 & L3 flash green in a clockwise direction. PE & N illuminate green. Phases wired incorrectly. Phase sequence is L1, L3, L2. L1, L2 & L3 flash red in an anti-clockwise direction. Phase L1 is missing L2 & L3 fl ash red. Phase L2 is missing L1 & L3 fl ash red. Phase L3 is missing. L1 & L2 fl ash red. PE is missing. PE illuminates red (PC104). PE extinguished (PC105). 3 NA Neutral is missing. N illuminates red. 4