X-CELL Analytical. Biofuels Analysis. St. Francis Xavier University Analytical Services Lab. Equipment Specification Brochure

Similar documents
ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

SCOPE OF ACCREDITATION

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Annex no. 1 of Accreditation Certificate no. LI 333 from

Production of Biodiesel from Used Groundnut Oil from Bosso Market, Minna, Niger State, Nigeria

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Application Note. Author. Introduction. Energy and Fuels

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Biodiesel Fuel Quality

GC Method Compliance and Large Valve Oven Application

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Using the PSD for Backflushing on the Agilent 8890 GC System

Application. Gas Chromatography June 1995

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

ALL TESTS. Density Oscillating U-tube method * IP 365. Distillation characteristics of petroleum products - Micro distillation method IP 596

Determination of Free and Total Glycerin in B100 Biodiesel

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Project Reference No.: 40S_B_MTECH_007

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

ISBN SANS 342:2006 Edition 4 SOUTH AFRICAN NATIONAL STANDARD Automotive diesel fuel Published by Standards South Africa 1 dr lategan roa

Antek Gas Chromatography Products: A Guided Tour Through Industry

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

SOUTH AFRICAN NATIONAL STANDARD

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Agilent and ASTM. Update on Recent Activities. Page 1

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Louis Dreyfus Claypool Holdings, LLC. Biodiesel Production Plant Claypool, Indiana

TSHR 6000 series TN/TS/TX analyzer

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Prodigy ICP Application Note: # 1039

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

DETECTORS Photo Ionization Detector - PID. Overview

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

S-PRO 3200 GC System for Sulfur Analysis

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

CERTIFICATE OF ACCREDITATION

Metrohm. 743 Rancimat. Determination of the oxidation stability of Oils and fats Biodiesel Food and cosmetics

Closed Cup Flash Point Tester

Biodiesel Testing Equipment

Biodiesel: Making Renewable Fuel from Waste Oils

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Biofuels and characteristics

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

TESTING OF FUELS : FLASH AND FIRE POINT

breakthrough versatility

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Application Note. Abstract. Authors. Environmental Analysis

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

What s s in your Tank?

Going Green: The Analysis of BioFuels

ASTM D189 pg 3. ASTM D130 pg 2. ASTM D445 pg 4. ASTM D874 pg 7. ASTM D1160 pg 6. ASTM D1160 pg 8 ASTM D1796/D2709 pg 9 ASTM D2274 pg 10

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

measuring vessel air inlet conductivity cell reaction vessel sample absorption solution (water) heating block (e.g. 120 C)

Biodiesel Specification in Indonesia

ANNEX 2, REFERENCE FUELS

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Agilent Multimode Inlet for Gas Chromatography

Certificate of Accreditation

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

MiniLab EL Series for High Performance Engine Development and Maintenance

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Extraction of Biofuel from Chicken Waste

Standard Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuels 1

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

Beverage Grade Carbon Dioxide

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Monitor Chlorine in Crude at Sub-ppm Levels

Biodiesel Technical Issues related to Biodiesel Production, Handling, Storage, and Use in Diesel Engines

Standard Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuels 1

FORCE TENSIOMETER K20 THE STAND-ALONE TENSIOMETER FOR QUALITY CONTROL

ASTM Methods that are feasible with Metrohm instruments

ANNEX 3 REFERENCE FUELS. Parameter Unit Limits (1) Test method Minimum Maximum Research octane number, RON

ISO Petroleum products Fuels (class F) Specifications of marine fuels

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Certificate of Accreditation

Transcription:

X-CELL Analytical Biofuels Analysis St. Francis Xavier University Analytical Services Lab Equipment Specification Brochure Physical Sciences Center PO Box 5000 Antigonish, NS, B2G 2W5 Canada Phone: 902-867-2324 Fax: 902-867-2414 E-mail: gmarango@stfx.ca

Biofuels Analysis Variables Measured Equipment Number Density 3, 4 p-anisidine value 5 Peroxide value 5, 7 Concentration of soaps 5, 7 Oxidation stability of oils and fats 6 Water content determinations 7, 8 Titration analysis 7, 8 Percentage of oil and water 13 Suspended and dissolved solids 13 measurement Flash point 18 Glycerin 21, 28 Sulfur 25 Cloud point 26, 27 Cold filter plugging 27 Cold soaked filterability 32 Carbon residue 31 Water & Sediment 29 Copper Strip Corrosion 30

Equipment Information 3 Lauda TD 1 C Surface Tensiometer Measurement type : surface and interfacial tension, density, weight Simple selection of measuring methods according to Du Noüy-ring, Wilhelmy-plate, or density measurement Measurements surface and interfacial tension < 300 mn/m (ring) ; < 999 mn/m (plate) Resolution ± 0.1 mn/m Density Measurement < 2000 g/l Resolution ±1 g/l Weight Measurement <5000 mg Resolution ±1 mg 4 Density Meter (DMA 5000) Measuring range: 0 to 3g/cm 3 Accuracy Density: 0.000005g/cm 3 Temperature: 0.01 o C Measuring Temperature: 0 o C to 90 o C (32 to 194 o F) Pressure range: 0 to 10 bar (0 to 145 psi) Minimum amount of sample: 1 ml Applications: Fine chemicals, Biodiesel, Bioethanol, Sea water, Crude oil, Fuel, Lubricants, Coatings, Beer and wort, Juice, Soft drinks, Spirits, and Wine.

5 FoodLabFat Measures the percentage of acidity, the amount of peroxides, the concentration of p-anisidine (AnV) and soaps in seed oils, dry fruit, essential oils, butter, cream, and edible fats and oils. 6 channel photometer designed to heat the samples at a temperature of 37 o C. Environmental operating specifications: the system and its components can be used in environments with a temperature ranging from 15 C to 35 C and a relative humidity from 20% to 90%, non condensing. Photometric range: 0.0-2.3 Abs 6 743 Rancimat For the determination of the oxidation stability of oils and fats, also referred to as Oil Stability Index (OSI). 8 sample positions, 2 separate heating blocks and a software solution for controlling methods, samples and data Applications: Vegetable fats/oils: soy, sunflower, corn, canola, coconut, peanut, palm, etc Animal fats/oils: butter, fish oil, lard, etc. Fat- or oil-containing products: o Direct measurements: margarine o After fat extraction: cereals, biscuits, cookies, nuts, bacon, sausages, meat, etc. Antioxidant research Oxidative stability of biodiesel and FAME (fatty acid methyl ester) Oxidation stability of light heating oil with Cu catalyst

7 787 KF Titrino With 703 Ti Stand Contains the four most important titration methods: Titer determination with water or water standard Titer determination with sodium tartrate Blank determination Karl Fischer titration- KFT Direct water content determinations in Liquids Solids Gases Viscous materials Range of water contents: 100 ppm-100% Range of start volume: 0-99.99mL 8 808 Titrando Titrator with built-in buret drive, one or two galvanically separated measuring interfaces with one high-impedance and one polarizable measuring input, measuring input for temperature sensor. Measuring ranges: Potentiometric : -2000mV- +2000mV ph: -20.00- +20.00 Amperometric: -2000mV- +2000mV Voltametric: -200 A- +200 A Resolution: Voltage: 0.1mV ph value: 0.001pH Current: 0.01uA Temperature: 0.1 o C Measuring Accuracy: Voltage: ± 0.2mV ph value: ± 0.003pH Temperature: ± 0.2 o C With 801Stirrer: Magnetic stirrer for use with the titrando. Applications: o Determining the water content in biodiesel by Karl Fischer titration. o Titration analyses of biofuels o Automated Karl Fischer titration for liquid samples Maximum speed: 1700-1900 min -1

13 OFITE Retort 50mL Retort with Digital Temperature Controller, 115V Measures the percentage of oil and water, and estimates both suspended and dissolved solids contained in a sample of water-based or oil-based muds and cuttings. 18 K16200 Pensky-Martens Closed Cup Flash Tester Determines flash points of a wide range of products by a closed cup method with two option speed stirring of the sample. Used in shipping and safety regulations for detection of contamination by volatile and flammable materials in fuel oils and lubricating oils, and for characterization of hazardous waste samples. Electrically heated model with a 750W nickel-chromium heater with stepless variable control for accurate, repeatable temperature rate of rise settings per specifications.

21 Hewlett Packard 5890 Series II Gas Chromatograph SRI Peak Simple Chromatography Data System Model 333 Column Oven: Operating range: 4 o C above ambient to 450 o C Setpoint entry: 1 o C for temperatures, 0.1 o C for program rates Programming: rates 0.1 to 70 o C per min, 650minutes maximum run time, three ramps with initial/ final holds Thermal conductivity detector (TCD): Range to 400 o C Flame ionization detector(fid): Range to 450 o C Grounded jet and current limited design for operator safety Push-button flame ignition Inlet systems: 5890 PI (Packed Inlet) 5890 Split/ Splitless Inlet with EPC (Series II with #039 only) 5890 Series II dual injectors (split/ splitless or packed) dual FID/TCD detectors Primary applications: analysis of herbicides, pesticides, biodiesels, many organic reaction products.

25 Antek (R) Model 9000V LLS Low Level Sulfur Analyzer Performs total sulfur analyses in LPGs (Liquefied petroleum gases) and syringeable liquids, including light viscous materials. Patented Pyro-fluorescence TM sulfur technology Enables unprecedented UVF (ultraviolet fluorescence) sensitivity Allows for sulfur analysis at the ppb level. Fast, precise measurement of liquid and gas samples Superior to wet chemistry and other instrumental methods No environmentally hazardous catalysts or reagents Utilizes ASTM D5453 methodology, which is accepted by the California Air Resources Board (CARB) for low level sulfur analysis in Phase 2 Reformulated Gasoline. European Union scientists (Workgroup 27) established this UVF technology as the method of choice for low (<10pg/kg) sulfur in motor fuels. Modular design of detectors and electronics. Single- or multi-point calibration curves. Post-analysis reprocessing including the ability to recalculate data with different calibration curves. Ability to plot 1 st, 2 nd and 3 rd order regression curves. Analytical Range Low ppb to 50 ppm Precision ±30 ppb or ±2% RSD, whichever is greater Typical Sample Size Gas: 5 to 15 ml LPG: < 15 L Liquid: 1 to 20 L Typical Analysis Time Less than five minutes Temperatures Combustion zone: ambient to 1100 o C in 1 o C increments The 9000 S (sulfur) system may be upgraded to a 9000 NS (nitrogen/sulfur) system at any time. Antek Model 735E Controlled Rate Sample Drive Provides precise, reproducible sample introduction into Antek elemental analyzers by either syringe or sample boat. 26 Cloud point

27 LAWLER Automated Cold Filter Plugging Point and Cloud Point Analyzer Model OL-14-2/ DR-2L One automated Cold Filter Plugging Point (CFPP) analyzer and one Cloud Point (CP) analyzer Fully conforming to the ASTM D6371 and ASTM D2500 manual test methods. Capable of automatically determining the CFPP and CP of most fuel and oil specimens. RTD temperature probes are located in the same position as prescribed by the respective methods. Directly refrigerated cooling Avoids the use of the alcohol cryostat by directly cooling the test jacket with refrigerant. Only ozone friendly, chlorine-free refrigerants are used. Capable of test jacket temperatures of - 34 o C, -51 o C, and -67 o C as per ASTM D6371 and 0 o C, -18 o C, -33 o C, -51 o C, and - 69 o C as per ASTM D2500 Touch panel display working with microprocessor (PLC) based software Software interprets all key parameters such as sample temperature, bath (jacket) temperature, cloud visibility, etc. and reports the test results on the display screen.

28 SRI 8610C Gas Chromatograph The SRI BioDiesel GC System is configured to perform ASTM 6584 (residual free and bound Glycerin in Bio Fuel). Analysis takes about 25 minutes. Model 8610C chassis Ambient to 400 o C column oven On-column injector with carrier EPC (Electronic Pressure Controller) Simple and Reproducible For liquids and gases with low and high boiling analytes No boiling point discrimination Low thermal mass FID Detector Hydrocarbon selective Robust, linear, stable Detects down to 1 ppm Unique Ceramic Ignitor can run HOT continuously to keep flame lit 15M x 0.53mm I.D. 0.15u Biodiesel Type MXT- 500 Metal Capillary Column Single channel PeakSimple data system at-a-glance display of temperatures, pressures, voltages, and detector parameters 29 Beckman J-6B Centrifuge Floor Model, refrigerated centrifuge Modified for determining the volume of free water and sediment in middle distillate fuels in accordance with ASTM D2709. Designed to operate at approximately 1600 rpm (giving a relative centrifugal force of approximately 80). Centrifuge head (able to withstand a force of approximately 2000 rpm) with four holders designed specifically for custom made 100 ml graduated tubes Easy to operate Speed dial, analogue display meters for rotor speed and temperature, timer (up to 30 minutes in one minute increments), braking system, start and stop buttons Adjustable over temp shutdown Accessories: 100 ml centrifuge tubes (readable to 0.005 ml and measurable to 0.01 ml), centrifuge tube holder

30 Lawler Model 279-4 Copper Corrosion Liquid Bath A heated liquid stainless steel bath designed to run ASTM D130 and also suitable for ASTM D1838 The temperature range is 40 to +180 C with temperature stability of ±0.2 C. Temperature is controlled with a digital display controller with 0.1 C resolution. Over temperature controller The bath is agitated with a bath circulation pump for bath uniformity. 8 test tube ports, 4 pressure vessel ports Accessories: Test tubes, stainless steel pressure vessels (test bombs), copper strips, ASTM copper corrosion standard, viewing test tube, polishing vise, metal test tube and test bomb holders 31 Carbon Residue 32 Cold Soaked Filterability