Tube Fitting Stainless SUS316 Compression Fitting Series

Similar documents
Multi-Circuit Rotary Block

Connector Series. Multiple Push-In Fitting Type. Desorption of Several Tubes at One Time. Combinable Connectors by Connector Band.

Exhaust Throttle (Needle) Valve ET

Speed Controller High Flow

Minimal Fitting Series

Tube Fitting Stainless SUS316 Series

Push-In Fitting Type Quick Exhaust Valve

Throttle (Needle) Valve PP Series

Main Block Series. Concentrated Branching Joint for Assembly. Assembling Manifold Blocks for Concentrated Branching

Light Coupling Series

Throttle (Needle) Valve Standard Series

Sub-D Connector. Concentrated wiringd Connector for Manifold type. Lead-Out Direction of cable is selectable. Suitable for PISCO's Solenoid Valves.

Tube Fitting PP Series

In-line Filter of Easy Maintenance

Vacuum Switch with LED display

Mechanical Valve Series

Tube Fitting Anti-spatter Series

Tube Fitting Brass Series

Pressure Switch with Super slim LED Display

Push-In Fitting Type Speed Control Valve Speed Controller Series

Push-In Fitting Type Speed Control Valve Speed Controller Series

Tube Fitting Stainless SUS304 Series

Tube Fitting EG Series

External Vacuum Controller with Blow-off Air and Relief Pressure Adjustment. External Vacuum Controller Series

Solenoid Valve SVR Series

Conventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Speed Controller with One-touch Fitting

The valve body is prepared in two different colors enabling the user to opt for either of the two according to operational environment.

Complex Vacuum Generator with Blow-off Air and Relief Pressure Adjustment

SUPPLY JOINTS CONTENTS

For Pneumatic Piping/Fittings & Tubing Prior to Use

Speed Controller with One-touch Fitting

Speed Controller with Indicator

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

SPEED CONTROLLERS WITH QUICK FITTINGS

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Speed Controller with Indicator

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

Two Hand Control Valve

Vacuum Generator VN. Vacuum level

ONE TOUCH FITTINGS Series WP2

Digital Catalog. Operation can be made from the toolbar at the center of the lower portion of the screen.

Tube. Flared I.D. Flared I.D. can prevent the tubing from deforming inwards. Specifications

Vacuum pad for packaging bag

One-touch Fittings 23% 24% 57% KQ2-G Series CAT.ES50-39A. 30% reduction. force 20% reduction 1. Stainless Steel. Improved tube insertion/removal

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4

Free position locking flat and compact cylinder UFCD Series

Valve Built-in self-seal mechanism. Air does not exhaust after removal of tubing. Stopper Cushion. Release button(blue) Guide Collet Chuck

Stainless One-touch Fittings. Applicable Tubing Tube material Tube O.D. Thread Nut

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Fluid medium. Operating pressure range. Operating temp. range. Fluid medium. Operating pressure range. Operating temp. range.

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

FIT-2. Inch. Ø Â" to Ë" O/D tube

H/DL/L/LL Series. Tube. Union nut. Flared I.D. Flared I.D. can prevent the tube from deforming inwards. Specifications

External vacuum controller

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

AUTO ACE COUPLER(Steel)

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD USA web:

EISELE IS QUALITY MADE IN GERMANY AVAILABLE ON STOCK IN GRAND RAPIDS, MI

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 ASP330F-N01 ASP430F-N02 ASP530F-N03 ASP630F-N04

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

3-Way Ball Valve Type 23H

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Transmitters: Relay Valve VR4151/4152

Standard Specifications

connection solutions in stainless steel

Applicable Tubing. Tubing material Note1) Tubing O.D. Note 1) ø2 is available in polyurethane only. Specifications

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.

Dome-Loaded Pressure Reducing BD-Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series

LF 3600 Push-In Fittings Range

Rotary Vacuum Pump RPV06. In-line twin rotor Parallel twin rotor Parallel triple rotor New Parallel quad rotor. >>>

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Doc. no.ck1*-om0066p. PRODUCT NAME Clamp Cylinder. MODEL / Series / Product Number

Butterfly Valves ASAHI AV VALVES

Fittings Metal Push-To- Connect Fittings. We make things MOVE

Quality Products at Competitive Prices awaits you with ATP! LIMITED WARRANTY

stainless steel compression fittings

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Pressure Relief 3 Port Valve With Locking Holes

Plug: KBP Elbow module: KBV Female connector union: KBH. Tubing. Guide. Chuck Collet. O-ring Lock ring. Spring Spring guide. Specifications.

Male stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature...

Stainless Steel 316 One-touch Fittings

Butterfly Valve Type 57P

Pneumatic Division North America Richland, MI 49083

Miniature Fittings Stainless Steel 316. Hose nipple. Barb Configuration for easy insertion into the tube Holds the tube tightly.

Technical information for LFU20-Z07-3A-X2

Composite Push-In Fittings BSP/Metric Series 7000

Brass Compression Fitting Range

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Port size AK AK AK AK /04 AK /10. Specifications

Miniature Regulator Series ARJ310

2-Color Display High-Precision Digital Pressure Switch

Fittings and Accessories. For oil and grease. For Centralized Lubrication Systems and General Use

STRAIGHT FITTING ORIFICE DISK MUFFLER MANIFOLD MOUNTING PLATE MULTI-FUNCTION IMPACT SEAL CYLINDER TUBE 1/4 BSPP ELBOW FITTING HEAD ASSEMBLY

Hose, Hose couplings & Adaptors B-HO-10E

Transcription:

http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Compression Fitting of Corrosion Resistant Steel Tube Fitting SUS316 Compression Fitting 120 Chemical Industry Medical Industry Medicine Industry Food Industry Chemical Corrosion Resistance SUS316 for All Parts. PP No Sleeve Required. No Worry about Forgetting or Losing Sleeve. EG Anti-spatter & Brass Die Temperature Control Cleaned and Packed in Clean Room Class 1000. Minimal Stop Fitting Rotary Newly Added Inch Size. Wide Variety of Products. Twist-Proof Fitting Block and Connector Coupling Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING Model Designation (Example) NS C 0640 01 SUS316 Compression Fitting 1 Type 2 Tube dia. 4 Thread sealing option 3 Thread size 1 Type Code Type Code Type Code Type Code Type C L B D MC U V E M CF MF MFF N P 121 Standard Mini 2 Tube dia. ( No code for MC and MFF ) Tube dia. mm size Code 0420 0425 0640 0860 1075 1080 1290 1210 1613 Tube O.D. (mm) ø4 ø6 ø8 ø10 ø12 ø16 Tube I.D. (mm) ø2 ø2.5 ø4 ø6 ø7.5 ø8 ø9 ø10 ø13 Code for Cap nut only 4 6 8 10 12 16 Code for Disc spring washer only 12 14 16 18 20 24 When only nut is required, enter the code for cap nut only. When only washer for Bulkhead type is required, enter the code for disc spring washer only. As for Bulkhead Socket, select the code from 3. Tube dia. inch size Code 1/4 3/8 1/2 Tube O.D. (mm) ø6.35 ø9.53 ø12.7 Tube I.D. (mm) ø4.57 ø6.99 ø9.56. Inch size compatible: 5/32 = 0425 and 5/16 = 0860. 3 Thread size Thread size Taper pipe thread Code 01 02 03 04 R R1/8 R1/4 R3/8 R1/2 Rc Rc1/8 Rc1/4 Rc3/8 Rc1/2 Code for Disc spring washer only 14 18 22 27. When washer for Bulkhead type is required, enter the code for disc spring washer only. 4 Thread sealing option No code:standard (No Sealock and seal tape) TP:Seal tape on thread (Seal tape wrapping on thread)

http://www.pisco.co.jp Specifications Fluid medium Air / Water / Others ( ) Max. operating pressure Max. vacuum Operating temp. range Follow the max. operation pressure of tube specification -100kPa Depends on the range of tube specification(no freezing) Warning The specification above may not be applied, depending on the kind of chemicals or mixed gases used as fluid medium. Make sure to use PISCO products after verifying their suitability on the user side. FITTING CONTROLLER VALVE TUBE Construction (Elbow: NSL) Fitting body (SUS316) Cap nut (SUS316) Tube MAKE-TO-ORDER PRODUCTS 122 Since this series is available for special applications such as chemical and food industries, there is no Sealock coating on the thread. Detailed Safety Instructions Before using PISCO products, be sure to read Safety Instructions and Safety Instruction Manual on page 23 to 27 and Common Safety Instructions for Fittings on page 33 to 35. Warning 1. When using chemicals or mixed gases as a fluid medium, be sure to contact us first. Depending on conditions, it may cause damage to the products, the escape of tubes and a fluid leakage. Caution 1. Taper thread is not coated with Sealock. When coating the thread with seal tape or sealant, do not coat 1.5 to 2 screw ridges from the tip of the thread. Chemical PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING Standard Size List Type Page Thread size Tube size mm size (O.D. x I.D.) (mm) inch size 4 2 4 2.5 6 4 8 6 10 7.5 10 8 12 9 12 10 16 13 1/4 3/8 1/2 NSC Straight P.125 R1/8 R1/4 R3/8 R1/2 NSL Elbow P.127 R1/8 R1/4 R3/8 R1/2 NSB Branch Tee P.130 R1/8 R1/4 R3/8 R1/2 NSD Run Tee P.131 R1/8 R1/4 R3/8 R1/2 NSMC Bulkhead Straight P.132 R1/8 R1/4 R3/8 R1/2 Connection: Thread Tube Type Page Thread Tube size mm size (O.D. x I.D.) (mm) inch size size 4 2 4 2.5 6 4 8 6 10 7.5 10 8 12 9 12 10 16 13 1/4 3/8 1/2 NSCF Female Straight P.128 Rc1/8 Rc1/4 Rc3/8 Rc1/2 NSMF Bulkhead Female Straight P.133 Rc1/8 Rc1/4 Rc3/8 Rc1/2 123 Standard Mini Connection: Tube Tube (Equal dia.) Tube size Type Page mm size (O.D. x I.D.) (mm) inch size 4 2 4 2.5 6 4 8 6 10 7.5 10 8 12 9 12 10 16 13 1/4 3/8 1/2 NSU Union Straight P.126 NSV Union Elbow P.126 NSE Union Tee P.129 NSM Bulkhead Union P.129 Nut Type Page Tube size mm size (O.D. x I.D.) (mm) inch size 4 2 4 2.5 6 4 8 6 10 7.5 10 8 12 9 12 10 16 13 1/4 3/8 1/2 NSN Cap Nut Only P.134 Connection: Thread Thread Type Page Thread Thread size 2 size 1 Rc1/8 Rc1/4 Rc3/8 Rc1/2 NSMFF Bulkhead Socket P.134 Rc1/8 Rc1/4 Rc3/8 Rc1/2 Washer 隔壁部 Thread size (mm) Type Page 12 14 16 18 20 22 24 27 NSP Disk spring washer for Bulkhead type P.135

http://www.pisco.co.jp How to insert and disconnect 1. How to insert and disconnect tubes 1 Tube insertion Pass the tube through the nut and insert the barb into the tube up to the barb end. Use a spanner to tighten the nut until the screw end. 2 Tube disconnection Loosen the nut by a spanner first and pull the tube out. Before tube disconnection, make sure to stop fluids such as air, water, etc. FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS 2. How to tighten thread 1 Tightening thread Use a spanner to tighten a hexagonal-column or square part of the fitting. Since there is no Sealock coating on taper pipe thread, use seal tape or sealant if necessary. Refer to Table 2: Recommended tightening torque / Sealock color / Gasket materials under 4. Instructions for Installing a fitting in Common Safety Instructions for Fittings. 124 Applicable Tube and Related Products Fluororesin (PFA) Tube P.628 Polyamide Tube P.634 Needle Valve SUS316 P.460 Chemical PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING NSC Straight B E1 E2 C 125 Standard Mini Model code Tube O.D. x I.D. A R A B E1 E2 C R Orifice dia. Effective area (ø mm) (mm 2 ) file name NSC0420-01 R1/8 4 2 NSC0420-02 R1/4 NSC0425-01 4 2.5 R1/8 NSC0425-02 ( 1) R1/4 NSC0640-01 R1/8 NSC0640-02 6 4 R1/4 NSC0640-03 R3/8 NSC0860-01 R1/8 8 6 NSC0860-02 R1/4 ( 2) NSC0860-03 R3/8 NSC1075-02 R1/4 NSC1075-03 10 7.5 R3/8 NSC1075-04 R1/2 NSC1080-02 R1/4 NSC1080-03 10 8 R3/8 NSC1080-04 R1/2 NSC1290-02 R1/4 NSC1290-03 12 9 R3/8 NSC1290-04 R1/2 NSC1210-02 R1/4 NSC1210-03 12 10 R3/8 NSC1210-04 R1/2 NSC1613-03 R3/8 16 13 NSC1613-04 R1/2 NSC1/4-01 R1/8 NSC1/4-02 6.35 4.57 R1/4 NSC1/4-03 R3/8 NSC3/8-02 R1/4 NSC3/8-03 9.53 6.99 R3/8 NSC3/8-04 R1/2 NSC1/2-02 R1/4 NSC1/2-03 12.7 9.56 R3/8 NSC1/2-04 R1/2 1. Equal to inch size 5/32 2. Equal to inch size 5/16 3. E1 is a reference value for dimension after tightening thread. 4. in Model code / Replaced with TP for Seal tape data is available at PISCO website. data is available at PISCO website.

http://www.pisco.co.jp NSU Model code Union Straight Tube O.D. x I.D. B E C B 6 2-2-E 2-C 2- Orifice dia. (ø mm) Effective area (mm 2 ) file name NSU0420 4 2 NSU0425 4 2.5 NSU0640 6 4 NSU0860 8 6 NSU1075 10 7.5 NSU1080 10 8 NSU1290 12 9 NSU1210 12 10 NSU1613 16 13 FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS NSV Union Elbow 2-E1 2-E2 2-C 126 2-(B) 2- Chemical Model code Tube O.D. x I.D. B E1 E2 C Orifice dia. Effective area (ø mm) (mm 2 ) file name NSV0420 4 2 NSV0425 4 2.5 NSV0640 6 4 NSV0860 8 6 NSV1075 10 7.5 NSV1080 10 8 NSV1290 12 9 NSV1210 12 10 NSV1613 16 13 PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling data is available at PISCO website. data is available at PISCO website. Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING NSL Elbow (E1) E2 E3 C (B) L2 L1 127 Standard Mini Model code Tube O.D. x I.D. A R A B L1 L2 E1 E2 E3 C R Orifice dia. Effective area (ø mm) (mm 2 ) file name NSL0420-01 R1/8 4 2 NSL0420-02 R1/4 NSL0425-01 4 2.5 R1/8 NSL0425-02 ( 1) R1/4 NSL0640-01 R1/8 NSL0640-02 6 4 R1/4 NSL0640-03 R3/8 NSL0860-01 R1/8 8 6 NSL0860-02 R1/4 ( 2) NSL0860-03 R3/8 NSL1075-02 R1/4 NSL1075-03 10 7.5 R3/8 NSL1075-04 R1/2 NSL1080-02 R1/4 NSL1080-03 10 8 R3/8 NSL1080-04 R1/2 NSL1290-02 R1/4 NSL1290-03 12 9 R3/8 NSL1290-04 R1/2 NSL1210-02 R1/4 NSL1210-03 12 10 R3/8 NSL1210-04 R1/2 NSL1613-03 R3/8 16 13 NSL1613-04 R1/2 NSL1/4-01 R1/8 NSL1/4-02 6.35 4.57 R1/4 NSL1/4-03 R3/8 NSL3/8-02 R1/4 NSL3/8-03 9.53 6.99 R3/8 NSL3/8-04 R1/2 NSL1/2-02 R1/4 NSL1/2-03 12.7 9.56 R3/8 NSL1/2-04 R1/2 1. Equal to inch size 5/32 2. Equal to inch size 5/16 3. L1 is a reference value for height dimension after tightening thread. 4. in Model code / Replaced with TP for Seal tape data is available at PISCO website. data is available at PISCO website.

http://www.pisco.co.jp NSCF Model code Female Straight Tube O.D. x I.D. Rc E1 A B Rc A B E1 E2 C E2 C Orifice dia. Effective area (ø mm) (mm 2 ) file name NSCF0420-01 4 2 Rc1/8 NSCF0420-02 Rc1/4 NSCF0425-01 4 2.5 Rc1/8 NSCF0425-02 ( 1) Rc1/4 NSCF0640-01 Rc1/8 NSCF0640-02 6 4 Rc1/4 NSCF0640-03 Rc3/8 NSCF0860-01 Rc1/8 8 6 NSCF0860-02 Rc1/4 ( 2) NSCF0860-03 Rc3/8 NSCF1075-01 Rc1/8 NSCF1075-02 Rc1/4 10 7.5 NSCF1075-03 Rc3/8 NSCF1075-04 Rc1/2 NSCF1080-01 Rc1/8 NSCF1080-02 Rc1/4 10 8 NSCF1080-03 Rc3/8 NSCF1080-04 Rc1/2 NSCF1290-02 Rc1/4 NSCF1290-03 12 9 Rc3/8 NSCF1290-04 Rc1/2 NSCF1210-02 Rc1/4 NSCF1210-03 12 10 Rc3/8 NSCF1210-04 Rc1/2 NSCF1613-03 Rc3/8 16 13 NSCF1613-04 Rc1/2 NSCF1/4-01 Rc1/8 NSCF1/4-02 6.35 4.57 Rc1/4 NSCF1/4-03 Rc3/8 NSCF3/8-01 Rc1/8 NSCF3/8-02 Rc1/4 9.53 6.99 NSCF3/8-03 Rc3/8 NSCF3/8-04 Rc1/2 NSCF1/2-02 Rc1/4 NSCF1/2-03 12.7 9.56 Rc3/8 NSCF1/2-04 Rc1/2 1. Equal to inch size 5/32 2. Equal to inch size 5/16 FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS 128 Chemical PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling data is available at PISCO website. data is available at PISCO website. Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING NSE Union Tee 3-E1 3-E2 3-C 129 Model code Tube O.D. x I.D. E1 E2 C 3-3- Orifice dia. (ø mm) Effective area (mm 2 ) file name NSE0420 4 2 NSE0425 4 2.5 ( 1) NSE0640 6 4 NSE0860 8 6 ( 2) NSE1075 10 7.5 NSE1080 10 8 NSE1290 12 9 NSE1210 12 10 NSE1613 16 13 NSE1/4 6.35 4.57 NSE3/8 9.53 6.99 NSE1/2 12.7 9.56 1. Equal to inch size 5/32 2. Equal to inch size 5/16 Standard Mini NSM Bulkhead Union Straight E2 B E4 E3 2-E1 2-C Model code Tube O.D. x I.D. M H3 M B E1 E2 E3 E4 C 2-2- H3 Orifice dia. Effective area (ø mm) (mm 2 ) file name NSM0420 4 2 NSM0425 4 2.5 NSM0640 6 4 NSM0860 8 6 NSM1075 10 7.5 NSM1080 10 8 NSM1290 12 9 NSM1210 12 10 NSM1613 16 13 data is available at PISCO website. data is available at PISCO website.

http://www.pisco.co.jp NSB Model code Branch Tee Tube O.D. x I.D. (B2) B1 L A E2 2-E1 2-E3 2-C R 2-2- R A B1 (B2) L E1 E2 E3 C Orifice dia. Effective area (ø mm) (mm 2 ) file name NSB0420-01 R1/8 4 2 NSB0420-02 R1/4 NSB0425-01 R1/8 4 2.5 NSB0425-02 R1/4 NSB0640-01 R1/8 NSB0640-02 6 4 R1/4 NSB0640-03 R3/8 NSB0860-01 R1/8 NSB0860-02 8 6 R1/4 NSB0860-03 R3/8 NSB1075-02 R1/4 NSB1075-03 10 7.5 R3/8 NSB1075-04 R1/2 NSB1080-02 R1/4 NSB1080-03 10 8 R3/8 NSB1080-04 R1/2 NSB1290-02 R1/4 NSB1290-03 12 9 R3/8 NSB1290-04 R1/2 NSB1210-02 R1/4 NSB1210-03 12 10 R3/8 NSB1210-04 R1/2 NSB1613-03 R3/8 16 13 NSB1613-04 R1/2. L is a reference value for height dimension after tightening thread.. in Model code / Replaced with TP for Seal tape FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS 130 Chemical PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling data is available at PISCO website. data is available at PISCO website. Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING NSD Run Tee (E2) E1 B L1 2-E3 2-2-C 131 Standard Mini Model code Tube O.D. x I.D. L2 A 2- R R A B L1 L2 E1 (E2) E3 C Orifice dia. Effective area (ø mm) (mm 2 ) file name NSD0420-01 R1/8 4 2 NSD0420-02 R1/4 NSD0425-01 R1/8 4 2.5 NSD0425-02 R1/4 NSD0640-01 R1/8 NSD0640-02 6 4 R1/4 NSD0640-03 R3/8 NSD0860-01 R1/8 NSD0860-02 8 6 R1/4 NSD0860-03 R3/8 NSD1075-02 R1/4 NSD1075-03 10 7.5 R3/8 NSD1075-04 R1/2 NSD1080-02 R1/4 NSD1080-03 10 8 R3/8 NSD1080-04 R1/2 NSD1290-02 R1/4 NSD1290-03 12 9 R3/8 NSD1290-04 R1/2 NSD1210-02 R1/4 NSD1210-03 12 10 R3/8 NSD1210-04 R1/2 NSD1613-03 R3/8 16 13 NSD1613-04 R1/2. L is a reference value for height dimension after tightening thread.. in Model code / Replaced with TP for Seal tape data is available at PISCO website. data is available at PISCO website.

http://www.pisco.co.jp NSMC Model code Bulkhead Straight Tube O.D. x I.D. R E2 A B E4 E3 M H3 L E1 C R A M B L E1 E2 E3 E4 C H3 Orifice dia. Effective area (ø mm) (mm 2 ) file name NSMC0420-01 R1/8 4 2 NSMC0420-02 R1/4 NSMC0425-01 R1/8 4 2.5 NSMC0425-02 R1/4 NSMC0640-01 R1/8 NSMC0640-02 6 4 R1/4 NSMC0640-03 R3/8 NSMC0860-01 R1/8 NSMC0860-02 8 6 R1/4 NSMC0860-03 R3/8 NSMC1075-01 R1/8 NSMC1075-02 R1/4 10 7.5 NSMC1075-03 R3/8 NSMC1075-04 R1/2 NSMC1080-01 R1/8 NSMC1080-02 R1/4 10 8 NSMC1080-03 R3/8 NSMC1080-04 R1/2 NSMC1290-02 R1/4 NSMC1290-03 12 9 R3/8 NSMC1290-04 R1/2 NSMC1210-02 R1/4 NSMC1210-03 12 10 R3/8 NSMC1210-04 R1/2 NSMC1613-03 R3/8 16 13 NSMC1613-04 R1/2. in Model code / Replaced with TP for Seal tape FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS 132 Chemical PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling data is available at PISCO website. data is available at PISCO website. Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING NSMF Bulkhead Female Straight E2 B E4 E3 E1 C 133 Standard Mini Model code Tube O.D. x I.D. Rc A M H3 Rc A M B E1 E2 E3 E4 C H3 Orifice dia. Effective area (ø mm) (mm 2 ) file name NSMF0420-01 4 2 Rc1/8 NSMF0420-02 Rc1/4 NSMF0425-01 Rc1/8 4 2.5 NSMF0425-02 Rc1/4 NSMF0640-01 Rc1/8 NSMF0640-02 6 4 Rc1/4 NSMF0640-03 Rc3/8 NSMF0860-01 Rc1/8 NSMF0860-02 8 6 Rc1/4 NSMF0860-03 Rc3/8 NSMF1075-01 Rc1/8 NSMF1075-02 Rc1/4 10 7.5 NSMF1075-03 Rc3/8 NSMF1075-04 Rc1/2 NSMF1080-01 Rc1/8 NSMF1080-02 Rc1/4 10 8 NSMF1080-03 Rc3/8 NSMF1080-04 Rc1/2 NSMF1290-02 Rc1/4 NSMF1290-03 12 9 Rc3/8 NSMF1290-04 Rc1/2 NSMF1210-02 Rc1/4 NSMF1210-03 12 10 Rc3/8 NSMF1210-04 Rc1/2 NSMF1613-03 Rc3/8 16 13 NSMF1613-04 Rc1/2 NSMF1/4-01 Rc1/8 NSMF1/4-02 6.35 4.57 Rc1/4 NSMF1/4-03 Rc3/8 NSMF3/8-01 Rc1/8 NSMF3/8-02 Rc1/4 9.53 6.99 NSMF3/8-03 Rc3/8 NSMF3/8-04 Rc1/2 NSMF1/2-02 Rc1/4 NSMF1/2-03 12.7 9.56 Rc3/8 NSMF1/2-04 Rc1/2 1. Equal to inch size 5/32 2. Equal to inch size 5/16 data is available at PISCO website. data is available at PISCO website.

http://www.pisco.co.jp NSMFF Bulkhead Socket 6 2-A B E2 E1 2-Rc Model code Rc A M B E1 E2 M Orifice dia. (ø mm) file name NSMFF01 Rc1/8 NSMFF02 Rc1/4 NSMFF03 Rc3/8 NSMFF04 Rc1/2 FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS 134 NSN Cap Nut Only C E B Model code Tube O.D. x I.D. B L E C H NSN4 4 2, 4 2.5 NSN6 6 4 NSN8 8 6 NSN10 10 7.5, 10 8 NSN12 12 9, 12 10 NSN16 16 13 NSN1/4 6.35 4.57 NSN3/8 9.53 6.99 NSN1/2 12.7 9.56 L H file name - Chemical PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling data is available at PISCO website. data is available at PISCO website. Color Cap

Fitting Tube Fitting SUS316 Compression Fitting FITTING NSP Disc spring washer for Bulkhead type H ød t Model code ød H t file name NSP12 12 17 NSP14 14 20 NSP16 16 22 NSP18 18 25 NSP20 20 28 NSP22 22 30 NSP24 24 30 - NSP27 27 36 135 Standard Mini data is available at PISCO website. data is available at PISCO website.

Safety Instructions SAFETY Instructions This safety instructions aim to prevent personal injury and damage to properties by requiring proper use of PISCO products. Be certain to follow ISO 4414 and JIS B 8370 ISO 4414:Pneumatic fluid power Recomendations for the application of equipment to transmission and control systems. JIS B 8370:General rules and safety requirements for systems and their components. This safety instructions is classified into Danger, Warning and Caution depending on the degree of danger or damages caused by improper use of PISCO products. Danger Warning Caution Hazardous conditions. It can cause death or serious personal injury. Hazardous conditions depending on usages. Improper use of PISCO products can cause death or serious personal injury. Hazardous conditions depending on usages. Improper use of PISCO products can cause personal injury or damages to properties. 23 Warning 1. Selection of pneumatic products 1 A user who is a pneumatic system designer or has sufficient experience and technical expertise should select PISCO products. 2 Due to wide variety of operating conditions and applications for PISCO products, carry out the analysis and evaluation on PISCO products. The pneumatic system designer is solely responsible for assuring that the user's requirements are met and that the application presents no health or safety hazards. All designers are required to fully understand the specifications of PISCO products and constitute all systems based on the latest catalog or information, considering any malfunctions. 2. Handle the pneumatic equipment with enough knowledge and experience 1 Improper use of compressed air is dangerous. Assembly, operation and maintenance of machines using pneumatic equipment should be conducted by a person with enough knowledge and experience. 3. Do not operate machine / equipment or remove pneumatic equipment until safety is confirmed. 1 Make sure that preventive measures against falling work-pieces or sudden movements of machine are completed before inspection or maintenance of these machine. 2 Make sure the above preventive measures are completed. A compressed air supply and the power supply to the machine must be off, and also the compressed air in the systems must be exhausted. 3 Restart the machines with care after ensuring to take all preventive measures against sudden movements.. This safety instructions are subject to change without notice.

http://www.pisco.co.jp Disclaimer 1. PISCO does not take any responsibility for any incidental or indirect loss, such as production line stop, interruption of business, loss of benefits, personal injury, etc., caused by any failure on use or application of PISCO products. 2. PISCO does not take any responsibility for any loss caused by natural disasters, fires not related to PISCO products, acts by third parties, and intentional or accidental damages of PISCO products due to incorrect usage. 3. PISCO does not take any responsibility for any loss caused by improper usage of PISCO products such as exceeding the specification limit or not following the usage the published instructions and catalog allow. 4. PISCO does not take any responsibility for any loss caused by remodeling of PISCO products, or by combinational use with non-pisco products and other software systems. 5. The damages caused by the defect of Pisco products shall be covered but limited to the full amount of the PISCO products paid by the customer. 24

Safety Instructions 25 SAFETY INSTRUCTION MANUAL PISCO products are designed and manufactured for use in general industrial machines. Be sure to read and follow the instructions below. Danger 1. Do not use PISCO products for the following applications. 1 Equipment used for maintaining / handling human life and body. 2 Equipment used for moving / transporting human. 3 Equipment specifically used for safety purposes. Warning 1. Do not use PISCO products under the following conditions. 1 Beyond the specifications or conditions stated in the catalog, or the instructions. 2 Under the direct sunlight or outdoors. 3 Excessive vibrations and impacts. 4 Exposure / adhere to corrosive gas, inflammable gas, chemicals, seawater, water and vapor. * * Some products can be used under the condition above(4), refer to the details of specification and condition of each product. 2. Do not disassemble or modify PISCO products, which affect the performance, function, and basic structure of the product. 3. Turn off the power supply, stop the air supply to PISCO products, and make sure there is no residual air pressure in the pipes before maintenance and inspection. 4. Do not touch the release-ring of push-in fitting when there is a working pressure. The lock may be released by the physical contact, and tube may fly out or slip out. 5. Frequent switchover of compressed air may generate heat, and there is a risk of causing burn injury. 6. Avoid any load on PISCO products, such as a tensile strength, twisting and bending. Otherwise, there is a risk of causing damage to the products. 7. As for applications where threads or tubes swing / rotate, use Rotary Joints, High Rotary Joints or Multi-Circuit Rotary Block only. The other PISCO products can be damaged in these applications. 8. Use only Die Temperature Control Fitting, Tube Fitting SUS316, Tube Fitting SUS316 Compression Fitting or Tube Fitting Brass under the condition of over 60 (140 F) water or thermal oil. Other PISCO products can be damaged by heat and hydrolysis under the condition above. 9. As for the condition required to dissipate static electricity or provide an antistatic performance, use EG series fitting and antistatic products only, and do not use other PISCO products. There is a risk that static electricity can cause system defects or failures. 10. Use only Fittings with a characteristic of spatter-proof such as Antispatter or Brass series in a place where flame and weld spatter is produced. There is a risk of causing fire by sparks. 11. Turn off the power supply to PISCO products, and make sure there is no residual air pressure in the pipes and equipment before maintenance. Follow the instructions below in order to ensure safety. 1 Make sure the safety of all systems related to PISCO products before maintenance. 2 Restart of operation after maintenance shall be proceeded with care after ensuring safety of the system by preventive measures against unexpected movements of machines and devices where pneumatic equipment is used. 3 Keep enough space for maintenance when designing a circuit. 12. Take safety measures such as providing a protection cover if there is a risk of causing damages or fires on machine / facilities by a fluid leakage.

http://www.pisco.co.jp Caution 1. Remove dusts or drain before piping. They may get into the peripheral machine / facilities and cause malfunction. 2. When inserting an ultra-soft tube into push-in fitting, make sure to place an Insert Ring into the tube edge. There is a risk of causing the escape of tube and a fluid leakage without using an Insert Ring. 3. The product incorporating NBR as seal rubber material has a risk of malfunction caused by ozone crack. Ozone exists in high concentrations in static elimination air, clean-room, and near the high-voltage motors, etc. As a countermeasure, material change from NBR to HNBR or FKM is necessary. Consult with PISCO for more information. 4. Special option Oil-free products may cause a very small amount of a fluid leakage. When a fluid medium is liquid or the products are required to be used in harsh environments, contact us for further information. 5. In case of using non-pisco brand tubes, make sure the tolerance of the outer tube diameter is within the limits of Table 1. Table 1. Tube O.D. Tolerance mm size Nylon tube Polyurethane tube inch size Nylon tube Polyurethane tube ø1.8mm ±0.05mm ø1/8 ±0.1mm ±0.15mm ø3mm ±0.15mm ø5/32 ±0.1mm ±0.15mm ø4mm ±0.1mm ±0.15mm ø3/16 ±0.1mm ±0.15mm ø6mm ±0.1mm ±0.15mm ø1/4 ±0.1mm ±0.15mm ø8mm ±0.1mm ±0.15mm ø5/16 ±0.1mm ±0.15mm ø10mm ±0.1mm ±0.15mm ø3/8 ±0.1mm ±0.15mm ø12mm ±0.1mm ±0.15mm ø1/2 ±0.1mm ±0.15mm ø16mm ±0.1mm ±0.15mm ø5/8 ±0.1mm ±0.15mm 6. Instructions for Tube Insertion 1 Make sure that the cut end surface of the tube is at right angle without a scratch on the surface and deformations. 2 When inserting a tube, the tube needs to be inserted fully into the pushin fitting until the tubing edge touches the tube end of the fitting as shown in the figure below. Otherwise, there is a risk of leakage. 26 Tube end Sealing Tube is not fully inserted up to tube end. 3 After inserting the tube, make sure it is inserted properly and not to be disconnected by pulling it moderately.. When inserting tubes, Lock-claws may be hardly visible in the hole, observed from the front face of the release-ring. But it does not mean the tube will surely escape. Major causes of the tube escape are the followings; 1Shear drop of the lock-claws edge 2The problem of tube diameter (usually small) Therefore, follow the above instructions from 1 to 3, even lock-claws is hardly visible.

Safety Instructions 7. Instructions for Tube Disconnection 1 Make sure there is no air pressure inside of the tube, before disconnecting it. 2 Push the release-ring of the push-in fitting evenly and deeply enough to pull out the tube toward oneself. By insufficient pushing of the releasering, the tube may not be pulled out or damaged by scratch, and tube shavings may remain inside of the fitting, which may cause the leakage later. 8. Instructions for Installing a fitting 1 When installing a fitting, use proper tools to tighten a hexagonal-column or an inner hexagonal socket. When inserting a hex key into the inner hexagonal socket of the fitting, be careful so that the tool does not touch lock-claws. The deformation of lock-claws may result in a poor performance of systems or an escape of the tube. 2 Refer to Table 2 which shows the recommended tightening torque. Do not exceed these limits to tighten a thread. Excessive tightening may break the thread part or deform the gasket and cause a fluid leakage. Tightening thread with tightening torque lower than these limits may cause a loosened thread or a fluid leakage. 3 Adjust the tube direction while tightening thread within these limits, since some PISCO products are not rotatable after the installation. Table 2: Recommended tightening torque / Sealock color / Gasket materials 27 Thread type Thread size Tightening torque Sealock color Gasket materials M3 0.5 0.7N m SUS304 M5 0.8 1.0 ~ 1.5N m NBR M6 1 2 ~ 2.7N m Metric thread M3 0.5 0.5 ~ 0.6N m M5 0.8 1 ~ 1.5N m M6 0.75 0.8 ~ 1N m POM M8 0.75 1 ~ 2N m R1/8 7 ~ 9N m Taper pipe thread R1/4 12 ~ 14N m R3/8 22 ~ 24N m White R1/2 28 ~ 30N m Unified thread No.10-32UNF 1.0 ~ 1.5N m SUS304 NBR 1/16-27NPT 7 ~ 9N m 1/8-27NPT 7 ~ 9N m National pipe 1/4-18NPT 12 ~ 14N m thread taper 3/8-18NPT 22 ~ 24N m White 1/2-14NPT 28 ~ 30N m These values may differ for some products. Refer to each specification as well. 9. Instructions for removing a fitting 1 When removing a fitting, use proper tools to loosen a hexagonal-column or an inner hex bolt. 2 Remove the sealant stuck on the mating equipment. The remained sealant may get into the peripheral equipment and cause malfunctions. 10. Arrange piping avoiding any load on fittings and tubes such as twist, tensile, moment load, shaking and physical impact. These may cause damages to fittings, tube deformations, bursting and the escape of tubes.

Fitting FITTING Common Safety Instructions for Fittings Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series as well as the instructions below. Warning 1. Do not use fittings with fluid medium other than air or water. (Water can be used with some series.) Contact us for using other kind of fluid medium except air and water. 2. Do not use fittings except Anti-spatter, Brass and Brass Compression Fitting series in a place where the flame and weld spatter is produced. There is a risk of causing fire by sparks. 3.As for applications where threads or tubes swing / rotate, use Rotary Joints, High Rotary Joints or Multi-Circuit Rotary Block only. The other PISCO products can be damaged in these applications. 33 4.Use only Die Temperature Control Fitting, Tube Fitting SUS316, Tube Fitting SUS316 Compression Fitting or Tube Fitting Brass under the condition of over 60 (140 F) water or thermal oil. Other PISCO products can be damaged by heat and hydrolysis under the condition above. 5.As for the condition required to dissipate static electricity or provide an antistatic performance, use EG fitting and antistatic products only, and do not use other PISCO products. There is a risk that static electricity can cause system defects or failures. 6. Avoid any load on PISCO products, such as a tensile strength, twisting and bending. Otherwise, there is a risk of causing damage to the products.

http://www.pisco.co.jp Caution 1.In case of using non-pisco brand tubes, make sure the tolerance of the outer tube diameter is within the following limits of Table 1. Table 1. Tube O.D. Tolerance mm size Nylon tube Urethane tube inch size Nylon tube Urethane tube ø1.8mm ±0.05mm ø1/8 ±0.1mm ±0.15mm ø3mm ±0.15mm ø5/32 ±0.1mm ±0.15mm ø4mm ±0.1mm ±0.15mm ø3/16 ±0.1mm ±0.15mm ø6mm ±0.1mm ±0.15mm ø1/4 ±0.1mm ±0.15mm ø8mm ±0.1mm ±0.15mm ø5/16 ±0.1mm ±0.15mm ø10mm ±0.1mm ±0.15mm ø3/8 ±0.1mm ±0.15mm ø12mm ±0.1mm ±0.15mm ø1/2 ±0.1mm ±0.15mm ø16mm ±0.1mm ±0.15mm ø5/8 ±0.1mm ±0.15mm FITTING CONTROLLER VALVE TUBE 2. Instructions for Tube Insertion 1 Make sure that the cut end surface of the tube is at right angle without a scratch on the tube surface and deformations. MAKE-TO-ORDER PRODUCTS 2 When inserting a tube, the tube needs to be inserted fully into the push-in fitting until the tubing edge touches the tube end of the fitting as shown in the figure below. Otherwise, there is a risk of leakage. Tube end 34 Standard Mini Sealing Tube is not fully inserted up to tube end. 3 After inserting the tube, make sure it is inserted properly and not to be disconnected by pulling it moderately. 3. Instructions for Tube Disconnection 1 Make sure there is no air pressure inside of the tube, before disconnecting it. 2 Push the release-ring of the push-in fitting evenly and deeply enough to pull out the tube toward oneself. By insufficient pushing of the release-ring, the tube may not be pulled out or damaged by scratch, and tube shavings may remain inside of the fitting, which may cause the leakage later. Chemical PP EG Anti-spatter & Brass Die Temperature Control Minimal Stop Fitting Rotary Twist-Proof Fitting Block and Connector Coupling Color Cap

Fitting FITTING 4. Instructions for Installing a fitting 1 When installing a fitting, use proper tools to tighten a hexagonal-column or an inner hexagonal socket. When inserting a hex key into the inner hexagonal socket of the fitting, be careful so that the tool does not touch lock-claws. The deformation of lock-claws may result in a poor performance of systems or an escape of the tube. 2 Refer to Table 2 which shows the recommended tightening torque. Do not exceed these limits to tighten a thread. Excessive tightening may break the thread part or deform the gasket and cause a fluid leakage. Tightening thread with tightening torque lower than these limits may cause a loosened thread or a fluid leakage. 3 Adjust the tube direction while tightening thread within these limits, since some PISCO products are not rotatable the installation. Table 2: Recommended tightening torque / Sealock color / Gasket materials 35 Thread type Thread size Tightening torque Sealock color Gasket materials M3 0.5 0.7N m SUS304 M5 0.8 1.0 ~ 1.5N m NBR M6 1 2 ~ 2.7N m Metric thread M3 0.5 0.5 ~0.6N m M5 0.8 1 ~1.5N m M6 0.75 0.8 ~ 1N m POM M8 0.75 1 ~ 2N m R1/8 7 ~ 9N m Taper pipe thread R1/4 12 ~ 14N m R3/8 22 ~ 24N m White R1/2 28 ~ 30N m Unified thread No.10-32UNF 1.0 ~ 1.5N m SUS304 NBR 1/16-28NPT 7 ~ 9N m 1/8-27NPT 7 ~ 9N m National pipe thread 1/4-18NPT 12 ~ 14N m taper 3/8-18NPT 22 ~ 24N m White 1/2-14NPT 28 ~ 30N m.these values may differ for some products. Refer to each specification as well 5.Instructions for removng a fitting 1 When removing a fitting, use proper tools to loosen a hexagonal-column or an inner hexagonal socket. 2 Remove the sealant stuck on the mating equipment. The remained sealant may get into the peripheral equipment and cause malfunctions. 6.Arrange piping avoiding any load on fittings and tubes such as twist, tensile, moment load, shaking and physical impact. These may cause damages to fittings, tube deformations, bursting and the escape of tubes.