Thermostats Series 142

Similar documents
Temperature controls, Type RT

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Pressure Control, Differential Pressure Control, Type RT

Temperature control, differential temperature control, type RT

Pressure controls and thermostats, type KPS

3RG4 BERO Inductive Proximity Switches

Control switch/load disconnect switch Series 8008

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

AQUASTATS THERMOSTAT APPLICATION

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK

Pressure and temperature controls, Type CAS

Explosion-protected surface-mounting Thermostat ATH-Ex Series

9 Control Equipment. Control Unit System Series ConSig 8040

TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper

Pressure switch and Thermostat Type CAS

10 Load and Motor Switchgear

60T Series Snap-Action Temperature Controls

Pressostats and thermostats CAS

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

Recommended Applications Interference suppressor for AC Primary Line of electronic equipments. Explanation of Part Numbers.

Technical data for manual motor starters Type MS325

Electric linear actuators

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION

Thermostatically operated cooling water valves Type AVTA

Pressure controls, differential pressure controls Type RT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

FSP Fan Speed Power Module Technical Data

Product overview linear actuators SBA

Room thermostats type series TRM

PS1 / PS2 Series Pressure Controls Technical Data

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Product Catalogue. Electromechanical controllers REL

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Ex Pressostat EXPK 944/947/953. Applications. Features

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Monitoring device OTV 30

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Limit Switch Type 4747

Core Industrial Products for Distributors and Wholesalers in North America

Operating Instructions

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Thermostat for shipbuilding Switching differential Not adjustable

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Sheet-Steel Light Fittings Series 6014 / 6414

Electromagnetic Flow Monitor magphant

A good connection. International approvals.

Thermostatic valve Type AVTA

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Accessories Cable glands

EX-REPAIR AND MAINTENANCE RECEPTACLES

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

International approvals.

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Alterostat M2S 104/114. Applications. Features

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

Reed sensor For bypass level indicators Model BLR

Control pressure switch series FF 4

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Control Buttons Series 8082

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Plug and Socket Devices SolConeX 16 A Series 8570

ZE motor-protective relay Overload monitoring of EEx e motors

Control Buttons / Switches for Panel Mounting Series 8003

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

BETA SWITCHES FOR HAZARDOUS AREA

LINEAR ELECTRIC ACTUATORS

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Installation Accessories

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Ministat M/MS 624/634. Applications. Features

Valve Position Monitors

/2-way piston valves

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale

Safety Switches Series 8537

Hydraulic pressure switch 20D Acc. to ATEX

Technical Information

Protection Equipment. 5/2 Introduction

Remote Temperature Controllers. Quick Selection Guide

THE EXPERT IN LEVEL AND FLOW

Differential Pressure Sensors

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

Rod thermostats (without immersion tube)

FF Pressure Switch. Diaphragm and piston switches

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

37T Series Moisture Resistant Temperature Controls

Floodlight Series 6121

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

6 Motors. BAUER motors are available as standard for the following three-phase line voltages:

7 Lighting Technology

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

Terminal Boxes Series 8125

Transcription:

Thermostats Series Features Large setting scale Standard two SPDT, one SPDT on explosion proof types Rugged, insulation proved housing, protection class IP 55 Silumin types IP 65 (i. e. for maritime application) Explosion proof types IP 55 Sealable TF Standard Housing TFg Silumin Housing Ex / TF V Technical Data TF / TFg Type of Contacts Non-Inductive Amp. (AC) Inductive Amp. (AC) Inductive Amp. (DC) Motor Rating, Full Load Amp. Motor Rating, Locked Rotor Amp. Bellows Heater at TFL / TFLg Ambient Temperature Range Vibration Resistance (0 to 000 Hz) Protection acc. to DIN 0050 / IEC 59 Cable Entry Options SPDT 6 A / 30 V AC 6 A / 30 V AC 0, A / 30 V DC A / 30 V AC 7 A / 30 V AC 30 V AC -50 C to +70 C g IP 55 with Standard Housing IP 65 with Silumin Housing Cable Glands Pg 3,5, Plastics at Standard Housing Cable Glands Pg 3,5, Brass at Silumin Housing Gold Plated Contacts for Electronic Application Technical Data Ex / TF V Ex-Protection acc. to VDE 070/07 i. e. EEx ed IIC T6 EN 500/8/9 Certificate of Conformity PTB No. Ex - 80 / 089 Type of Contacts SPDT, Flame Proof Non-Inductive Amp. (AC) 7 A / 30 V AC Inductive Amp. (AC) 0,5 A / 30 V AC Inductive Amp. (DC) 0,03 A / 30 V DC Protection acc. to DIN 0050 / IEC 59 IP 55 Ambient Temperature Range -0 C to +0 C Vibration Resistance (0 to 000 Hz) g Cable Entry Cable Gland Pg 3,5, Brass Electrical Connection Ex-Proof Terminals 66 A.5./0005/E

Thermostats with Standard Housing VDE 0660 / 063 Type Order- Range Lowest Factory Max. Bulb Charge Capillary No. Upper Differential Switch Point Setting Bulb and Style Tube Switch Point ÐVT Temp. Length C K C C C m TF - AA 06 056 59-5 -0,5 6-50 -8 / -0 +50 TF - AA 06 056 6-30 +0,5 6-39 - / 6 +50 Vapor/A TF - 3 AA 06 056 3-0 +5 8-8 +,5 / + +50 TF - 3 AD 06 056-0 +5 8-8 +0 / +8 +50 TF - AD 06 056 0 +5 +50 8-7 +0 / +35 +70 Liquid/D TF - 5 AD 06 056 08 +5 +75, 8 + +60 / +55 +00 TF - 5 AC 06 056 96 +5 +75, 8 + +60 / +55 +00 TF - 6 AC 06 056 8 +50 +00,5 0 +3 +80 / +75 +5 TF - 7 AC 06 056 7 +75 +0,8 0 +67 +00 / +95 +5 Liquid/C TF - 8 AC 06 056 60 +90 +0,8 0 +79 +0 / +5 +60 TF - 9 AC 06 056 58 +30 +80 3,5 +5 +30 / +55 +0 Room Thermostats with SPDT Contact TFL - AE00/ W 056 33-5 -0 6-50 -8 / -0 +70 TFL - AE00/ W 056-30 +0 6-39 - / -6 +70 Vapor/E 0 TFL - 3 AE00/ W 056 9-0 +5, 8-8 + / + +70 TFL - AE00/ W 056 095 +5 +50, 8-7 +0 / +8 +70 Frost Monitors TW - AP 0 056 6 +,5 +7,5 fix + +,5 / + +50 TB - DP 0/ W 0600 0 +,5 +7 man. Reset min. + +50 Vapor/P 6 (Limiter with SPDT contact) appr.,5 fix Thermostats with Silumin Housing VDE 0660 / 063 Type Order- Range Lowest Factory Max. Bulb Charge Capillary No. Upper Differential Switch Point Setting Bulb and Style Tube Switch Point ÐVT Temp. Length C K C C C m TFg - AA 06 0600 006-5 -0,5 6-50 -8 / -0 +50 TFg - AA 06 0600 009-30 +0,5 6-39 - / 6 +50 Vapor/A TFg - 3 AA 06 0600 0-0 +5 8-8 +,5 / + +50 TFg - 3 AD 06 0600 030-0 +5 8-8 +0 / +8 +50 TFg - AD 06 0600 033 +5 +50 8-7 +0 / +35 +70 Liquid/D TFg - 5 AD 06 0600 036 +5 +75, 8 + +60 / +55 +00 TFg - 5 AC 06 0600 05 +5 +75, 8 + +60 / +55 +00 TFg - 6 AC 06 0600 08 +50 +00,5 0 +3 +80 / +75 +5 TFg - 7 AC 06 0600 0 +75 +0,8 0 +67 +00 / +95 +5 Liquid/C TFg - 8 AC 06 0600 0 +90 +0,8 0 +79 +0 / +5 +60 TFg - 9 AC 06 0600 07 +30 +80 3,5 +5 +60 / +55 +0 Room Thermostats with SPDT Contact TFLg - AE00/ W 0600 055-5 -0 6-50 -8 / -0 +70 TFLg - AE00/ W 0600 058-30 +0 6-39 - / -6 +70 Vapor/E 0 TFLg - 3 AE00/ W 0600 06-0 +5, 8-8 + / + +70 TFLg - AE00/ W 0600 06 +5 +50, 8-7 +0 / +8 +70 Frost Monitors TWg - AP 0 0600 039 +,5 +7,5 fix + +,5 / + +50 TBg - DP 0/ W 0600 03 +,5 +7 man Reset min. + +50 Vapor/P 6 (Limiter with SPDT Contact) appr.,5 fix A.5./0005/E 67

# " # & " Thermostats Ex-Proof VDE 07, EN 500/8/9 Type Order- Range Lowest Factory Max. Bulb Charge Capillary No. upper Differential Switch Point Setting Bulb and Style Tube Switch Point ÐVT Temp. Length C K C C C m Ex / TF V - AA 06 0600 008-5 -0,5 6-50 -8 / -0 +50 Ex / TF V - AA 06 0600 0-30 +0,5 6-39 - / 6 +50 Vapor/A Ex / TF V - 3 AA 06 0600 0-0 +5 8-8 +,5 / + +50 Ex / TF V - 3 AD 06 0600 03-0 +5 8-8 +0 / +8 +50 Ex / TF V - AD 06 0600 035 +5 +50 8-7 +0 / +35 +70 Liquid/D Ex / TF V - 5 AD 06 0600 038 +5 +75, 8 + +60 / +55 +00 Ex / TF V - 5 AC 06 0600 07 +5 +75, 8 + +60 / +55 +00 Ex / TF V - 6 AC 06 0600 00 +50 +00,5 0 +3 +80 / +75 +5 Ex / TF V - 7 AC 06 0600 03 +75 +0,8 0 +67 +00 / +95 +5 Liquid/C Ex / TF V - 8 AC 06 0600 06 +90 +0,8 0 +79 +0 / +5 +60 Ex / TF V - 9 AC 06 0600 09 +30 +80 3,5 +5 +60 / +55 +0 Room Thermostats Ex / TFL V - AE00 0600 057-5 -0 6-50 -8 / -0 +70 Ex / TFL V - AE00 0600 060-30 +0 6-39 - / -6 +70 Vapor/E 0 Ex / TFL V - 3 AE00 0600 063-0 +5, 8-8 + / + +70 Ex / TFL V - AE00 0600 066 +5 +50, 8-7 +0 / +8 +70 Frost Monitors Ex / TF V - AP 0 0600 0 +,5 +7,5 fix + +,5 / + +50 Vapor/P 6 Accessories & Spare Parts Description Order-No. Insulation Console for TS 0 6 39 Mounting Console for TF(L) / 0 7 3 Locking Piece for TF(L) / 0 0 0 Blanking Plug instead of Adjusting Knob, for TF(L) / 0 36 770 Capillary Tube Holder e.g. for Frost Monitors 0 3 Capillary Tube Glands, Brass R/, max. 5bar tight, max. 00 C for Bulb Style A / C / D 0 56 867 Sensing Bulb Wells Mounting Depth mm Thread for Bulb Order-No. without Thread with Thread R 7,0 66,0 /HH A 0 56 88 37,0 56,0 /HH C 0 56 893 66,5 86,5 /HH F 0 0 85 66,0 87,0 3/HH D 0 56 97 # #,5 5 $ # # # " Ø,5 5 $ " &! M 5 $ # $ Mounting bracket angle Extension bracket Universal mounting bracket PCN: 0 7 PCN: 0 7 6 PCN: 0 7 7 68 A.5./0005/E

Thermostats Basic Terms and Technical Information Characteristics ALCO-thermostats are electric circuit control devices which open or close an electric contact depending on temperature changes at the bulb. Description of bulb charges The application range of thermostats in mainly determined by the charge. Accordingly various bulb shapes and sizes are necessary. x x Vapour charge, bulb type A, E, P The thermosystem is filled with a medium in vapour phase. A thermostat with vapour charge operates in accordance with temperature changes at the bulb as long as the bulb is the coldest part in the whole system (bellows, capillary tube, bulb). ALCO thermostats are equipped with a bellows heater (8 kohm, 30 V) to avoid such conditions (not for TF and Explosion proof types). On applications with low current the bellows heater has to be removed. Max. bulb temperature is 50 C (70 C for bulb type E). Response time is very fast. Liquid charge Bulb type D : This charge only reacts on temperature changes at the bulb. The max. bulb temperature is 00 C. Bulb type C: Bulb must be warmer than capillary tube and bellow (i.e. for heating purpose). Max. bulb temperature is 0 C. Response time is fast. x Adsorption charge, bulb type F This charge only reacts on temperature changes at the bulb. Max. bulb temperature is 00 C. Response time is slow but perfectly suitable for common refrigeration systems. Adjustment of switching points A thermometer should always be used for comparison when adjusting the switching points on temperature controls. The setting scale on the device is intended to serve for orientation, showing the setting range of the upper switching point t max in C and F and the value of the temperature differentialvt in K as difference between the upper switching point t max and the lower switching point t min. The upper switching point t max has to be adjusted on the scale, whereas the lower switching point t min is given by adjustment of the desired switching differential Vt. The formula is: Upper switching point Differential = Lower switching point t max Vt = t min Important! The differential Vt mentioned on the differential scale and in the technical data refers to the upper part of the setting range and the upper switching point. In the lower part of the setting range an increase of the differential Vt can be expected. The lowest possible lower switching point t min is mentioned in the selection tables and is helpful to select switching points with large differentials Vt in the lower temperature range. Bulb Sizes A E P C D F 5 65 AMW.6..00 70 AMW.6..00 0 Ø 9 70 AMW.6.6.00 Ø,5 AMW.6..00 AMW.6.5.00 AMW.6.3.00 Ø Ø Ø 9,5 Vapour Vapour Vapour Liquid Liquid Adsorption 6 A.5./0005/E

Function of contacts SPDT - On temperature rise above setting - opens and - closes. - On temperature drop below setting - closes and - opens. SPDT - with off switch AUTOmatic - STOP SPDT with manual reset min. - On temperature drop below setting - closes, - opens and latches. - The device can be manually reset when the temperature has risen at least K above setting. SPDT - with bellows heater include a 8 k Ohm, 30 V ac/dc resistor SPDT with manual reset max. - On temperature rise above setting - opens and - closes and latches. - The device can be manually reset when the temperature has dropped K below setting. Standards and regulations Important for the installation of thermostats: VDE 070/07: Regulations for firedamp and explosion proofed electric equipment VDE 063: Specification for temperature controls and (EN 60730) temperature cut-outs VDE 0660: Specifications for low-voltage switchgear. (EN 6097) EN 378: Refrigerating systems and heat pumps - Safety and environmental requirements Selection Guide for Thermostats Selection Criteria Design Temperature Protection Number Suitable for Adjust- Rated Operational Series Range DIN 0050 of low Voltage able Current at 30V AC Cata- IEC 59 Contacts Applications Inductive Motor logue (SPDT) i.e. Amp. Rating Page C Electronic AC UL Standard IP 3/ TS model -55 to +80 IP30 with - Yes 0 A A 6 off switch Higher Optional TF require- -50 to +80 IP 55 gold plated Yes 6 A A 66 ments contacts For outdoor Optional Yes TFg and maritime -50 to +80 IP 65 gold plated after removing 6 A A 66 applications contacts cover Ex-proof Yes Ex/TF V EEx -50 to +80 IP 55 - after removing 0,5 A - 66 ed IIC T6 cover Neutral TFM zone -50 to +80 IP 55 Neutral Standard Yes 0,5 A - - thermostat zone A.5./0005/E 63

Standards and Regulations Country and testing authority Series Series Series Series Series Series 5/5 PS3 FD 3 FSF/ PT3 FV Europe CE per Low Voltage Directive 73/3/EWG Y Y Y Y Y Y Europe FSF CE per EMC Directive 89/336/EWG FV + Y Filter Europe EN 50 0 / 8 / 9 N Germany TÜV N N N N Germany VDE N N N Canada CSA Y Y Y Denmark Demko K K K K Finland El.-Inspektoratet Y Y Y Norway Nemko Y N Y Austria ÖVE Y K Y K Switzerland SEV Y Y Y Y USA Unterwriter Laboratories Y S S Y FSF Ship classification organizations German. Lloyd GL N 3 G 3 LIoyd s Register of Shipping LRS G 3 Register of USSR RS G 3 Notes Y Standard version approved G Silumin version approved K No approval necessary. Standard version can be used. S Special version approved For TÜV approved pressure switches only Manufactured and tested to VDE standards on our own responsibilty. 3 For use on ships the devices must be fitted with marine-type cable glands. Explosion-proof version approved NEMA-guidelines are fulfilled by all units in UL-approved version. 8 A.5./0005/E