Pressure sensor for liquid and gaseous media QBE620-P...

Similar documents
Pressure Sensors. for liquid and gaseous media

Differential Pressure Sensors

Differential Pressure Sensors

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential pressure sensor

Differential Pressure Sensors

Differential Pressure Sensors

Modulating control valve PN16 with magnetic actuator

Relative and absolute pressure transmitter type 691

Electronic Pressure Switch EDS 3000

Submersible Pressure

Pressure transducer DMU 01K Compact version

Pressure Transmitters

Type A-10 General Purpose Pressure Transmitters

Actuators for small valves

JUMO MIDAS S05 Pressure transmitter Type

Relative and absolute pressure transmitter type 507

Modulating control valve PN16 with magnetic actuator

OEM relative pressure transmitter type 506

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Control of cutting-oil emulsion for industrial grinding machines. Applications for CHW and LPHW systems, see data sheet CA1N4454E.

Marine Pressure ECTN Applications. Features

JUMO MIDAS Pressure transmitter

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Air damper actuators

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)

Industrial Pressure Transmitter

ECT Applications. Features

Butterfly valves, PN6, PN10, PN16

Portable pressure calibrator, Wally Box III Model CPH7600

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

2-position electric actuators with Ball valves VBZ ½...11/4

EPI Applications. Features

Relative and absolute pressure transmitter type 528

FPT Applications. Features

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Figure 1: WPR2 Dimensions and Hardware

Actuators for Fire Protection Dampers

Relative pressure transmitter type 522 for shipbuilding

Pressure Transmitter

OEM Pressure Transmitters

Digital Pressure Regulator Sentronic PLUS Series 614

Modulating control valve PN16

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

CTE8000 / CTU8000 Series

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Industrial Pressure Transmitters

Type A-10 General Purpose Pressure Transmitter

Electronic Temperature Sensor ETS 300

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Positive displacement batch controller

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

CTE7000 / CTU7000 Series Miniature pressure transmitters

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

0-5V, 1-5V, 1-6V 0-10V, 1-10V V

Butterfly valves PN6, PN10, PN16

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic

Adjustment range. Seal material. Pressure connection

Actuators for Fire and Smoke Protection Dampers

PFT - the Flexible Pressure Transmitter

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

Air damper actuators

More Precision. mainsensor Magneto-inductive displacement sensor

Electronic Pressure Switches

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

Pressure Transmitter Series TST Pressure Range bar, mbar, bar Output Signals ma, V

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Paddle-wheel flow controller for On/Off control

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

SP38D Piezoresistive single crystal silicon differential pressure sensor

Electric actuators for small valves

Actuators for Fire and Smoke Protection Dampers

Electronic pressure switch with integrated analogue output

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

FlowCon Energy FIT System

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Pilot-Operated Proportional DC Valve Series D*1FH

Actuators for Fire and Smoke Protection Dampers

Digital display Pressure range ON/OFF output Linear output Model

Technical Principles of Valves

Proportional pressure regulators VPPX

INSERTION flow sensor for continuous flow measurement

Pressure Transmitters

Technical Datasheet P-30/P-31. Standard transmitter.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

SP38D Piezoresistive single crystal silicon differential pressure sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Operating instructions Flow monitors SI5000 SI / / 2007

Electronic Pressure Switches

PROPORTIONAL VALVES Sentronic D - G 1/8 to G 3/8 tapped body or G 1/8 - G 1/4 subbase mounted body with digital pressure control

Transcription:

1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal Complete sensor cast in synthetic resin Measurement unaffected by changes in temperature High temperature stability No mechanical ageing or creepage External thread G ½" Use The QBE620-P... pressure sensors are suitable for the measurement of static and dynamic positive pressure in HVAC applications, particularly in hydraulic and pneumatic systems using liquid or gaseous media. The sensor operates on piezo-resistive measuring principles. The ceramic diaphragm (thick-film hybrid technology) measures the pressure through direct contact with the medium. The measurement is converted electronically into a linear output signal of DC 0...10 V. 02.2001 Landis & Staefa Division

Type summary Seven different pressure sensor types are available, covering the entire pressure range from 0... 40 bar. Type Pressure range Signal QBE620-P1 0... 1 bar 0... 100 kpa 0... 14,5 psi DC 0...10 V QBE620-P4 0... 4 bar 0... 400 kpa 0... 58 psi DC 0...10 V QBE620-P5 0... 5 bar 0... 500 kpa 0... 72 psi DC 0...10 V QBE620-P10 0... 10 bar 0... 1,0 MPa 0... 145 psi DC 0...10 V QBE620-P16 0... 16 bar 0... 1,6 MPa 0... 232 psi DC 0...10 V QBE620-P25 0... 25 bar 0... 2,5 MPa 0... 362 psi DC 0...10 V QBE620-P40 0... 40 bar 0... 4,0 MPa 0... 580 psi DC 0...10 V Ordering When placing an order, please specify the quantity, product description and type code. Example: 4 pressure sensors QBE620-P1 and 2 mounting brackets AQB22.1 and 2 mounting kits AQB51.1 Accessories Any accessories required must be ordered separately. AQB22.1 Fixing bracket for sensor (for remote mounting). Dimensions see page 5 AQB51.1 Mounting kit comprising: 2 brass thread adapters, 2 x G 1 /8", male 2 copper seals, 1 /8" 1 m copper tube with retaining nuts at each end, G 1 /8" female 1 thread adapter, G 1 /8" female to G 1 /2" female, with 1 copper seal, 1 /2" 1 thread adapter, G 1 /8" female to R 1 /2" male Mounting instructions (no. 35 757) 80364a The components of the AQB51.1 mounting kit are supplied by SERTO, but the kit must be ordered from Landis & Staefa Division. Other mounting arrangements can be ordered directly from the SERTO range. Compatibility The QBE620-P... pressure sensors can be combined with all devices or systems capable of processing the DC 0...10 V output from the pressure sensor. 2/6

Mechanical design The QBE620-P... sensors are compact units, encapsulated in synthetic resin, and cannot be dismantled. No changes or adjustments are possible. Mounting Mounting instructions are enclosed with the sensor. The QBE620-P... sensors are designed for direct connection to screwed fittings with G½" threads. Appropriate measures must be taken to ensure a leak-proof fitting. To provide for test measurements without leakage of the medium, it is strongly recommended that an appropriate test adapter and shut-off device should be fitted. Pressure measurement with liquids Pressure measurement with condensing gases The tapping point should be at the side, near the bottom of the pipe. Do not measure the pressure from the top of the pipe (where it may be affected by airlocks) or the bottom (where it may be affected by dirt). Always evacuate the system. The tapping point should be at the top so that no condensate reaches the sensor. 50330 50329 Remote mounting If the ambient conditions in respect of temperature 15... + 80 C and vibration cannot be maintained, the sensor should be fitted remotely, taking care that no condensate can reach the sensor. 70219A For remote mounting a fixing brakket AQB22.1 and mounting kit AQB51.1 can be delivered, see "Accessories". QBE620... AQB22.1 Condensate or liquid AQB51.1 3/6

Technical data Electrical interface Power supply Supply voltage Max. voltage tolerance Current consumption Output signal With extra-low voltage only (SELV, PELV) AC 24 V, 50... 60 Hz or DC 18... 33 V ±15 % at AC 24 V <5mA DC 0...10 V, RLoad >10 kohm (no electrical isolation, three-wire connection, shortcircuit proof and protected against polarity reversal) Product data Application range 0... 40 bar (seven sensor types) Accuracy: Total of linearity, hysteresis and reproducibility Zero point offset voltage (FS = full scale) <±0.5%FS <50mV Temperature drift: TC zero point TC sensitivity Response time 90 % Nominal pressure Max. admissible pressure Rupture pressure Media Admissible temp. of medium Maintenance Orientation < ± 0.05 % FS / K < ± 0.015 % FS / K < 5 ms Relative pressure as in "Type summary" (Measurement of difference from ambient pressure) 2 x scale end value of measuring range (FS) 3 x scale end value of measuring range (FS) Neutral and mildly corrosive liquids and gases 15... + 80 C No maintenance required Any Materials Base Stainless steel (1.4305) Measuring element Ceramic diaphragm Cover Aluminium (Al Mg Si1), with silver-grey powder coating Sealant FPM rubber (Viton ) Sealing compound Synthetic resin Fixing bracket AQB22.1 Aluminium diecast Mounting kit AQB51.1 see "Accessories" Connection Connecting cable PVC, length 2 m, 3 x 0.25 mm 2 stranded conductors Screwed fitting External thread G1/2" General ambient conditions Temperature ranges Operation Storage Ambient humidity 15... + 80 C 25... + 85 C Class D to DIN40040 Dimensions / Weight Weight (including packaging) 0.31 kg Dimensions see page 5 Safety Protection standard IP65 to EN60529 Meets the requirements for CE marking in: EG89/336 (EMC), EN50081-1, EN50081-2, EN50082-2 4/6

Internal diagram G U M + 80358 0 Colour Brown Green White Supply voltage AC 24 V or DC 18... 33 V Output signal DC 0...10 V (Signal ground GND) GND Dimensions All dimensions in mm SW 27 70221 ø 40 G ½ 20 10 62 ~17 Fixing bracket AQB22.1 37.5 37 80362 M4 57 20 5 21 4.5 20 SW27 ø 4.5 10 5/6

6/6 2001 Ltd. Subject to changes

Represented By: POWER EQUIPMENT COMPANY 2011 Williamsburg Road Richmond, VA 23231 Ph. 804-236-3800 Fx. 804-236-3882 www.peconet.com