Installation& Maintenance Instructions

Similar documents
SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Installation & Maintenance Instructions

Easytork Solenoid Valve IOM

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Installation, Operation and Maintenance Manual

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES

CONTROL VALVES. Installation, Maintenance & Operating Instructions. Read these instructions carefully before installation or servicing.

Locktite Manual Reset Gas Shut-Off Valves

DA Series Diaphragm Valve

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

ANDCO Eagle Actuator Instruction Manual

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

Installation, Operation, and Maintenance Manual

Big Hermet Pressure Switches

Installation and Operating Manual

Solenoid Valve Installation Kit

1100 Series Piston Type Differential Pressure Gauges

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

SAFE & SECURE ACTUATOR PRODUCT MANUAL

CIRCLE SEAL CONTROLS

MC-351, 421, 431, MC-4311

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Type N550 Snappy Joe Emergency Shutoff Valves

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Installation and Service Instructions for Self Adjust Brakes 82,000 Series

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

DL/DS Series Diaphragm Valve

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

1000 Series Piston Type Differential Pressure Gauges

HQ Series ¼ Turn Electric Actuator

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

B21 Series BASOTROL Gas Valve

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline EC & EK Series Characterized Control Valves Sizes 1/2 6

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

HQ Series ¼ Turn Electric Actuator

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

Pneumatic Division North America Richland, MI 49083

Installation Instructions For Motor Control Center (MCC) Units

Fisher 657 Diaphragm Actuator Sizes and 87

CIRCLE SEAL CONTROLS

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

HQ-006 ¼ Turn Actuator

Eclipse AutoTite Automatic Gas Shut-Off Valves

RESISTIVITY MONITOR/CONTROLLERS

INSTALLATION AND OPERATION MANUAL

DR Series Radial Diaphragm Valves

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

HS6B Series Subminiature Interlock Switch

Actuated Valves. Product Information

MX4X-6XXX-20X Series MX4X-7XXX-20X Series

Introduction. Installation. Maintenance. Bill of Materials

Installation and Service Instructions for EX Series Explosion-proof Switches

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

BALDOR MN413 Brakes Manual

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation

GBV-G Balancing Valves

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

DP Series Diaphragm Valve Installation and Maintenance Instructions

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

Q35 Series Automatic Vent Damper System

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

Retractable System Operation & Maintenance Manual

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Type N550 Emergency Shutoff Valves. Instruction Manual. Type N550 Emergency Shutoff Valves. Introduction. Specifications. Scope of Manual.

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

RP-4000 Reserve Power Control

MOTOR. The electric motor. DC - direct current voltage.

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Thank You for Attending Today s Webinar. Today s Featured Speaker

Instruction Bulletin. Jockey Pump Controller

Shock/Vibration Control Switches

Type 657 Diaphragm Actuator Sizes and 87

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Electric Actuator Instructions

With regards to safety it is not necessary to check for correct operation.

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

Transcription:

Installation& Maintenance Instructions HS2 Valve Position Monitor With Integrated Valve Notice: These instructions are divided into two sections. Be sure to read, understand and follow all instructions on I&M No. V9538R2---Section1and2. Each valve position monitor is provided with a separate Mounting Plate Kit containing mounting instructions and all necessary parts to mount the valve position monitor to a specific actuator. See separate Installation Instructions For Mounting PlateKitsonI&MNo.V7490. DESCRIPTION Series HS2, HS3 and HS4 are visual and electrical valve position monitors for use with linear actuators. Visual indication of the actuator s OPEN/CLOSED position is accomplished by a yellow discwhichdisplaysthewordopenonthesideandtopofthevalve position monitor. When CLOSED, the disc retracts into the enclosure. Electrical indication is provided by one or two switches having a wide range of ratings and constructions to meet customer requirements. The integrated solenoid valve has an internal pilot which operates inconjunctionwiththelinearindicator. Itoffersa3/2NC operation. Separate Mounting Plates Kits are provided with each valve position monitor for direct mounting to a specific actuator. Series HS2 Valve Position Monitor is provided for indoor applications withanenclosuredesignedtomeettype4and4x --- Watertight, NonincendiveClassI,Division2,GroupsA,B,C&D,ClassIl,Class llldivision2,groupsf&g. Series HS3 Valve Position Monitor is provided for indoor/outdoor applications with an enclosure designed to meet IP66--- Watertight, NonincendiveClassI,Division2,GroupsA,B,C&D. Series HS4 Valve Position Monitor is provided with an enclosure designedtomeettype4and4x---watertight. INSTALLATION Check cover nameplate for correct catalog number and electrical rating of switches. Never exceed electrical rating of switches. Check valve nameplate for valve information including pressure, voltage, frequency and service. Installation and maintenance to be performed by qualified personnel. Temperature Limitations Ambienttemperaturerange:---20 Fto170 F(---29 Cto77 C) Media Air or neutral(inert) gas Positioning Position monitor may be mounted in any position. Mounting A separate mounting plate kit with installation instructions is supplied with each monitor. After the mounting plate kit is installedontheactuator,seesteps1through6startingonpage 3 of 6 for Mounting Valve Position Monitor To Actuator Mounting Plate. SERIES HS3 HS4 (Section1of2) Wiring Wiring must comply with local codes and National Electric Code. The position monitor enclosure is provided with 1/2 NPT or 1/2 NPSM conduit connections. Internal and external grounding locations are provided. To make electrical connections to terminal block, remove cover. Follow wiring diagrams inside housing cover or diagrams provided. For electrical connections use solid or stranded copperwirefrom28awgto14awg.stripwire1/4 thendepress wire clamp in terminal with screwdriver or similar flat edge tool, and insert wire in terminal block slot and release wire clamp. Before operation, replace housing cover. Wire Clamp Type Terminal 2 Enlarged view to show correct placement of wire and tool Stripwire1/4 theninsertscrewdriverorsimilarflatedgetool intoslot nexttoterminalwireentryslot,pushtool away fromwireslot toopenclamp. Insertwireandremovetool to release wire clamp. The position monitor is provided with independent switches. Each switch is adjusted independently to provide electrical indication of the actuators open or closed position. Switch Rating (T) ReedSwitch,Tungsten(SPDT) 3Ampsat120VAC(100VAmax) 2Ampsat24VDC(100WMAX) 3Watt(min) (R) ReedSwitch,Rhodium(SPDT) 1Ampsat24VAC/DC(max) 10mAat3VDC(min) (A) SnapSwitch,SilverContacts(SPDT) 15Ampsat125/250VAC(max) 125mAat125/250VAC(min) (HS4 ONLY) Correspondstocharacter#8ofcatalog. 1 3 Wiring Diagram See Figures 1 through 3 ASCOValves E222141--- 11/11 All Rights Reserved. I&M No. V 9538_Sec1 R2 Page1of6(Section1of2)

WARNING: To prevent the possibility of death, serious injury or property damage, turn off electrical power and depressurize actuator before installation, inspection or service. CAUTION: Failure to stay within electrical range may result in damage to or premature failure of electrical switches. WIRING DIAGRAMS INTEGRATED SOLENOID VALVE Figure 1. Wiring Diagram for SPDT--- Mechanical and Reed Switch INTEGRATED SOLENOID VALVE Figure 2. Wiring Diagram for Open SPDT--- Mechanical and Reed Switch INTEGRATED SOLENOID VALVE Figure 3. Wiring Diagram for Closed SPDT--- Mechanical and Reed Switch Note: Terminals7&8,inFigures1,2&3 are for solenoid connection. Code (A) (F) (D) Integrated Solenoid Valve Electrical Rating Wiring Diagram 1.0W at 120VAC 1.0W at 12VDC 0.5W at 24VDC See Figures 1 through 3 Mounting Valve Position Monitor to Actuator Mounting Plate 1. Mount valve position monitor in an orderly fashion paying careful attention to exploded views for proper orientation and locationofparts.refertosteps1through6startingonpage 3of6. 2. Install mounting plate kit on actuator following separate installation instructions. 3. Check base of valve position monitor to verify mounting screw gasket(3) and center gasket(1) are properly aligned. Center gasket supplied in mounting plate kit. 4. Locate three mounting screws and center shaft screw on valve positionmonitor.refertosteps2and5. 5. Checkthebottomofthevalvepositionmonitortoseethatthe centershaftscrewisvisibleandextendsbeyondthebase.ifthe screw is not visible and extended, loosen center knob screw on CLOSE adjustment knob and rotate knob until center shaft screw is extended. IMPORTANT: Before monitor installation on mounting plate, determine best location for main electrical connection of monitor. Threedeltamarks (120 apart)onmountingplateindicatewhere monitor can be mounted with main electrical connection directly above. 6. Install valve position monitor on mounting plate and align center shaft screw with actuator shaft. Torque center shaft screwto10in---lbsmaximum[1,1nmmaximum]. 7. Rotate valve position monitor on mounting plate to the best location for electrical connection. 8. Using a suitable screwdriver, thread all mounting screws a few turnsintomountingplate. Whenitisdeterminedthatall screws are properly engaged, torque mounting screws(3) evenlyinacrisscrossmannerto10in---lbsmaximum[1,1nm maximum]. 9. Make electrical connections and switch adjustments to valve position monitor. Replace enclosure cover before operation. Page2of 6(Section1of2)

STEP1 Install mounting plate kit on actuator, see separate instructions. STEP2 1. 2. Check base of monitor for mounting screw gaskets(3). Install center gasket in recess around shaft hole. Center gasket supplied in mounting plate kit. mounting screw gasket(3) center gasket STEP3 STEP4 Align center shaft screw with actuator shaft, then torque to 10in---lbsmaximum[1,1Nm maximum]. Lift and rotate enclosure for desirable position. Page3of6(Section1of2)

STEP5 Thread all mounting screws a few turns into mounting plate. Then torque mounting screws inacrisscrossmannerto10in---lbsmaximum [1,1 Nm maximum]. STEP6 Unlock CLOSE adjustment knob by loosening center screw. Turn knob in direction of arrow until switch is actuated. Once switch is activated, turn knob an additional 3 full turns to ensure visual indicator operates properly. Lock center screw. Replace cover before operation. Perform the same procedure for OPEN adjustment knob with actuator in the open position. NOTE: For constructions without an open switch, the OPEN adjustment knob should beturned inthe direction of the arrow (CCW)untilcamisatthe fully extended position with the actuator in the open position. Lock center screw. 3.73[95] 1.89[48] 5.007[127,18] 3.57[93] [124] 4.88.409[10,4].610[15,5].394[10] 1/2NPTor1/2 NPSMx1.5 thread 3.047[77,4].610[15,5].276[7] Figure 1. Integrated Valve Dimensions.409[10,4] Page4of 6(Section1of2)

Installation& Maintenance Instructions HS2 Valve Position Monitor With Integrated Valve I&MNo.V9538_Sec2R2 SERIES HS3 HS4 (Section2of2) Notice: These instructions are divided into two sections. Be sure to read, understand and follow all instructions on I&M No. V9538R2--- Sections 1 and 2. INTEGRATED SOLENOID VALVE These valves are 3--- way 2 position single solenoid valves designed for valve actuation use. INSTALLATION Check nameplate for pressure, voltage, frequency and service. Never apply incompatible fluids or exceed pressure rating of the valve. Installation and valve maintenance to be performed by qualified personnel. Piping/ Tubing Connect piping or tubing to valve according to marking on valve body. Refer to Flow Diagrams and Figure 6 for valve operation. Apply pipe compound sparingly to male pipe threads only. If applied to valve threads, the compound may enter the valve and cause operational difficulty. Avoid pipe strain by properly supporting and aligning piping. Wrenches applied to valve body or piping must be located as close as possible to connection point. CAUTION:Donotexceed200in---lbftorqueatvalve ports. CAUTION: These solenoid valves are intended for useoncleandryair,filteredto40micrometresorbetter. Thedewpointofthemediashouldbeatleast10 C(18 F) below the minimum temperature to which any portion ofthecleanair/inertgassystemcouldbeexposedto prevent freezing. If lubricated air is used, the lubricants must be compatible with Nitrile elastomers. Diester oils may cause operational problems. Instrument air in compliance with ANSI/ISA Standard 7.0.01--- 1996 exceeds the above requirements and is, therefore, an acceptable media for these valves. OPERATION Normally Closed: Applies pressure when solenoid is energized; exhausts pressure when solenoid is de--- energized. When solenoid isenergized,flowisfromport#1toport#2andport#3isclosed. Whensolenoidisde---energized,flowisfromPort#2toPort#3 andport#1isclosed. Manual Operator Manual operator allows manual operation during interruption of electrical power or when otherwise desired. A screw type of manual operator is supplied. To operate valve, rotate manual operator stem at side of valve body clockwise with a screwdriver until the valve shifts. Donotovertighten.Valvewillnowbeinthesamepositionaswhen the solenoid is energized. Rotate manual operator stem fully counterclockwise before operating valve electrically. 2 manual operator 3 1 3/2(N.C.) Flow Diagrams Port#1 View of side showing Manual Operator Operation: 3/2--- Normally Closed(N.C.) Operation Port#3 (exhaust) Port#2 (actuator N.C.) Port#1 (supply pressure) View Shown as Shipped Figure 2. Integrated Solenoid Valve Operation ASCOValves E222141--- 11/11 All Rights Reserved. I&M No. V 9538_Sec2 R2 Page5of6(Section2of2)

MAINTENANCE WARNING: To prevent the possibility of death, serious injury or property damage, turn off electrical power and depressurize actuator before installation, inspection or service. WARNING: To prevent the possibility of death, serious injury or property damage, connect supplypressurelinetoport#1only. Donotexceed maximum rated pressure. Causes of Improper Operation FaultyControlCircuit: Checktheelectricalpowersupplyto switches. Check for loose or blown fuses, grounded or open--- circuit wires, loose wire connections at terminal. Incorrect Electrical Indication: Check switch adjustment (setting) steps of valve position monitor. Preventive Maintenance Periodic inspection of the valve position monitor, external surfaces only, should be carried out. Position monitors should be kept clean and free from paint and foreign matter. Switch Replacement(Refer to Figure 6) FOR INFORMATION OR VALVE POSITION MONITOR OR SWITCH KITS CLOSE switch assembly Consult Factory or Authorized Factory Representative or Distributor Indicates Parts Supplied in Switch Rebuild Kit mounting screw(2) OPEN switch assembly 1. Remove switches in an orderly fashion paying careful attention to wire location, numbering, color codes and wiring diagrams provided. 2. From switch side of terminal block, remove switch wires from terminal block. Refer to Wiring section and Wiring Diagrams provided in Section 1. 3. Loosenandremovescrewontopofeachswitchassembly. 4. Slide switch assemblies from valve position monitor. 5. Install new switch assemblies, be sure switch marked OPEN isinstalledonopensideofvalvemonitorandswitchmarked CLOSE is installed on CLOSE side. 6. Install switch assembly mounting screw and torque to 2 in--- lbs [0,2Nm]. 7. Thread lead wires from both switches through wing on CLOSE side of monitor to terminal block. 8. Stripwire1/4 thendepresswireclampinterminalwithscrewdriver or similar flat edge tool, and insert wire in terminal block slot and release wire clamp. Before operation, replace housing cover. Refer to Wiring section and Wiring Diagrams provided. CLOSE wing OPEN 9. After new switch assemblies are installed, cycle monitor and check for proper switch operation. If necessary, readjust switches. Cause of Improper Visual Indication Incorrectsettingofadjustmentknob:Checkswitchadjustment setting of valve position monitor making sure 3 additional full turns are applied to ensure full visual indication. (Refer to STEP6onPage4inSection1) Thread switch lead wires through wing on CLOSE side to the terminal block. Figure 6. Switch Replacement Page6of6(Section2of2) I&MNo.V9538_Sec2R2