YASKAWA Energy in Motion TM

Similar documents
V1000, J7, V7, G5, P5, F7, E7

Compliance with CE Marking and UL Standard

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

CRegulatory. Compliance: UL and CE APPENDIX C IN THIS CHAPTER. Installation Instructions Installation Guidelines System Installation Techniques

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC

Installation Instructions

Mounting and Installation Guidelines

Filters for Converters and Power Electronics

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

Evaluation Certificate

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

ENERGY-SAVING DRIVE PACKAGE SPRiPM MOTOR & V1000 INVERTER DRIVE

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CC December 2010

Technical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT. Applies to the following models only: - FC.TGE - FC.OCIO

Varispeed J7 CIMR-J7AZ. System configuration

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

SPRiPM Package Energy-saving Drive Package of Super-Premium-iPM-Motor & Inverter Drive

Installation Manual. YASKAWA AC Drive Option Back-up Capacitor Unit for Momentary Power Loss. Type: P0010, P0020

YASKAWA IP54 Solutions. Product Launch Information , C. Schreiter

CIMR-V7AZ Varispeed V7

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Your Partner in Solutions 24/7. EMAW Worm Gearboxes. Tel: Fax: Web:

EMC INSTALLATION INFORMATION

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

Annex 3B COMMUNICATION

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

ZE motor-protective relay Overload monitoring of EEx e motors

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

SMT-BM 20 A BMM 05 F BMM 05 AF

SINAMICS G120. Inverter chassis units 0.37 kw to 90 kw Supplementary system components Basic Operator Panel BOP. Supplementary system components

Appendix: Safety and application notes for... 15

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

Parts Certificate Certificate for a part of a measuring system for LOTW

Packing Data Installation Instructions

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

SINAMICS G110 Inverter chassis units 0.12 kw to 3 kw

Micro Motion. CMF400 Sensor. Installation Instructions. Quick Reference Guide P/N , Rev. D May 2003

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol

Operating Instructions

ROTANTA 46 RSC ROBOTIC Robotic Centrifuge cooled

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

2.7. IT system floor-standing distribution cabinet Series -IPS-F

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

V-D2425 and V-D2440 Digital Clock

Comfort Pack Archived Part Lists PARTS LISTS

J1000. Compact Inverter Series.

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Encoder WDG 58V.

Test Report. E4S-Box V1.0

Informal document No. 2

Product Specification

Order No. of the options EMC filter Class A

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

INSTALLATION MANUAL. Automatic Transfer Switch Battery Backup Distribution. FLEXIBLE STORAGE within Battery Backup Function

Declaration of Conformity

YASKAWA AC Drive-V1000

V1000. Inverter Series.

V1000 Inverter Series

Automatic Transfer Switch Battery Backup Distribution

SIRIUS 3RU2 Thermal Overload Relays

EC Motors with LinMot Drives

Certificate of Conformity self-generation unit

Fan Coil Unit (FCU) Fan Motor Control

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

EC Motors with LinMot Drives

EDBMB935X.;p] Ä.;p]ä. Operating Instructions. EMB9351 E, EMB9352 E, EMB9351 C, EMB9352 C Braking unit

LED Driver Linear / area dimming

Spare Parts KPC 115-L-U/S, KPC115-L-S

CS Series Condensing Units

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Kinetix 5700 Capacitor Modules

micromaster Catalog DA MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

Manual motor starter MS132

Frankonia BlueBox - Mobile Load Machine -

Manual motor starter MS132

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

Electromotoric actuators

ILED Dorado. User Manual

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

NI 9251 with mini XLR

TEST EQUIPMENT USED. Part , ANSI C63.4, RSS 210

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

SolarMax 20C/25C/30C/35C. Proven reliability.

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

CFW PowerCable Redefining EMC. TN-S - the induction-free, low-radiation installation cable

Technical specification

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

ENERGY-SAVING DRIVE PACKAGE SPRiPM MOTOR & INVERTER DRIVE. SPRiPM

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

SERIES 54 Inductive Proximity Sensor

Transcription:

YASKAWA Energy in Motion TM Making YASKAWA Inverter Products Conform with the EMC Directive To assist you to comply with the EMC directives This information is for guidance only, good working practices should be followed at all times. EZZ 006543 Rev. 5 april. 04, 2002 Rev. 4 May. 21, 1999 Rev. 3 Mar. 13, 1998 Issued Nov. 30, 1995 Yaskawa Electric Europe GmbH Page 1 of 34

Contents Content Page 1. Introduction 4 2. Measures to make YASKAWA Inverters conform to EMC 4 3. Countermeasures for AC power supply and surrounding 5 3.1. Line Filter 5 3.2. Installation and wiring 5 4. Treatment of cables 5 4.1. Countermeasures against cable noise 5 APPENDIX 1 Recommended line filters for YASKAWA Inverters Appendix 1-1: Schaffner Filter for E7, F7 400 V 6 Schaffner Filter for E7, F7 200 V, 3 ph 7 Appendix 1-2: Schaffner Filter for all V7 8 Schaffner Filter for all J7 9 Appendix 1-3: Rasmi Filter for all V7 10 Rasmi Filter for all J7 11 Appendix 1-4: Schaffner Filter for G5, P5 400 V 12 Schaffner Filter for G5 575 V 13 Appendix 1-5: Rasmi Filter for G5,P5 400 V 14 Rasmi and Schaffner Filter for P5 200 V, 1 ph 15 Appendix 1-6: Rasmi Filter for VS mini C 16 Page 2 of 34

APPENDIX 2 Installation of line filter and inverters Appendix 2-1: Installation of line filter and CIMR-G5C40P4 to 4015, CIMR-P5C40P4 to 4015 17 Appendix 2-2: Installation of line filter and CIMR-G5C4018 to 4300, CIMR-P5C4018 to 4300 18 Appendix 2-3: Installation of line filter ( foot print type )and CIMR-G5C40P4 to 4015, CIMR-P5C40P4 to 4015 19 Appendix 2-4: Installation of line filter and CIMR-P5B00P4 to B3P7 20 Appendix 2-5: Installation of line filter and VS mini C 21 Appendix 2-6: Installation of line filters and CIMR-F7, E7C40P4 to 4018 CIMR-F7, E7C20P4 to 2018 22 Appendix 2-7: Installation of line filters and CIMR-F7, E7C4018 to 4300 CIMR-F7, E7C2018 to 2110 23 Appendix 2-8: Installation of line filters and CIMR-V7 C40P2 to 47P5 CIMR-V7 C20P1 to 24P0 24 Appendix 2-9: Installation of line filters and CIMR-V7 CB0P1 to B4P0 25 Appendix 2-10: Installation of line filters and CIMR-J7 C40P2 to 44P0 CIMR-J7 C20P1 to 24P0 26 Appendix 2-11: Installation of line filters and CIMR-J7 C20P1 to 24P0 27 Page 3 of 34

1. Introduction This document has been compiled as auxiliary material for use by each manufacturer using YASKAWA Inverters and described mainly countermeasures for EMC. Therefore please refer to Instruction Manual also for installation and wiring. We believe the Inverter that is installed according to this document and Instruction manual will meet following standards. Our inverter products have been tested by accredited laboratories with following norms: Product norm: EN 61800-3:1996, EN61800-3, A11: 2001 Emission (radiated ) : EN50081-2 (1993) EN55011 (1991) Class A Group 1 Emission ( conducted ) : EN50082-2 (1995) EN55011 (1991) Class A or B ( refer to attached tables ) 2. Measures to make YASKAWA Inverters conform to EMC Directive It is not necessary to mount YASKAWA inverters into a cabinet to keep the EMC limits. Therefore it is not possible to provide detailed installation guidelines. As a result we have to limit our instructions to a general guideline. All electrical devices could have some different radiated emissions which could be transmitted to other cables close by. Similar to an antenna these cables send this disturbance to their environment. If an electrical device ( i.e. an inverter ) is used without a proper filter high or low frequency disturbance could be send to the mains. General countermeasures are : separate wiring of power and control units. proper earthings screening of power and control cables To earth a high frequency disturbance with a low resistance a large area earthing is necessary. We recommend to use earthing strips instead of normal cables. Furthermore the screening of the cables must be earthed with proper earthing clamps. Page 4 of 34

3. Countermeasures for AC power supply and surrounding 3.1. Line Filter With regard to noise that is conducted on mains power supply by Inverters, a line filter is used as a countermeasure. In order to keep the EMC limits the recommended filters for YASKAWA Inverters. (Refer to APPENDIX 1) must be used. 3.2. Installation and wiring The line filter and the Inverter must be mounted on a same metal plate. The filter should be mounted as close as practical to the inverter. Keep cable as short as possible. The metal plate should be securely earthed. The frame (earth) of line filter and Inverter must be bonded to the metal plate with as much area as possible. For the motor cable, screened cable must be used and the screen of the motor cable is connected to earth at both ends by a short connection using as large area as practicable. 4. Treatment of cables 4.1. Countermeasures against cable noise The treatment of cables is the most important countermeasure. The machinery manufacturers are requested to examine the current structure of the cable lead - in. - Use cables with woven screen - The screen of the cable should be earthed with a large area. - It is desirable to earth the screen of the cable by clamping the cable to the earth plate. - The screen must be earthed on both side of the cable ( take care for good earthing system ) Ground bonds, remove any paint Examples : Number 1,2,3 show not proper ways to earth a cable screen. Page 5 of 34

Page 6 of 34

The following table shows recommended filters for YASKAWA Inverters APPENDIX 1-1 Recommended Line Filters for Varispeed F7and E7 made by Schaffner EMV AG ( 400V, 3phase ) Inverter Model Line Filter ( Schaffner ) Varispeed F7 Varispeed E7 Model EN 55011 CIMR-F7C40P4 CIMR-E7C40P4 B* CIMR-F7C40P7 CIMR-E7C40P7 FS 5972-10-07 B* 10 1.1 141 46 330 CIMR-F7C41P5 CIMR-E7C41P5 B* CIMR-F7C42P2 CIMR-E7C42P2 B* CIMR-F7C43P7 CIMR-E7C43P7 B* CIMR-F7C44P0 CIMR-E7C44P0 FS 5972-18-07 B* 18 1.3 141 x 46 x 330 CIMR-F7C45P5 CIMR-E7C45P5 B* CIMR-F7C47P5 CIMR-E7C47P5 FS 5972-21-07 B* 21 1,8 206 x 50 x 355 CIMR-F7C4011 CIMR-E7C4011 FS 5972-35-07 B* 35 2.1 206 x 50 x 355 CIMR-F7C4015 CIMR-E7C4015 FS 5972-60-07 B* 60 4.0 236 x 65 x 408 CIMR-F7C4018 CIMR-E7C4018 B* CIMR-F7C4022 CIMR-E7C4022 FS 5972-70-52 B* 70 3.4 80 x 185 x 329 CIMR-F7C4030 CIMR-E7C4030 B* CIMR-F7C4037 CIMR-E7C4037 FS 5972-100-35 B* 100 4,5 90 x 150 x 326 CIMR-F7C4045 CIMR-E7C4045 B* CIMR-F7C4055 CIMR-E7C4055 FS 5972-130-35 B* 130 4.7 90 x 180 x 366 CIMR-F7C4075 CIMR-E7C4075 FS 5972-170-40 B* 170 6.0 120 x 170 x 451 CIMR-F7C4090 CIMR-E7C4090 FS 5972-250-37 A 250 11.7 130 x 240 x 610 CIMR-F7C4110 CIMR-E7C4110 or FN 3359-250-28 A 7.0 230 x 125 x 300 CIMR-F7C4132 CIMR-E7C4132 FS 5972-400-99 A 400 18.5 300 x 160 x 564 CIMR-F7C4160 CIMR-E7C4160 or FS 5972-410-99 A 410 10.5 260 x 115 x 386 CIMR-F7C4185 CIMR-E7C4185 FS 5972-410-99 A 410 10.5 260 x 115 x 386 CIMR-F7C4220 CIMR-E7C4220 FS 5972-600-99 A 600 11 260 x 135 x 386 CIMR-F7C4300 CIMR-E7C4300 FS 5972-800-99 A 800 31 300 x 160 x 716 Rated Voltage Ambient Temperature : AC 480V 3phase : 45 C (max.) * max screened motor cable length : 50m Class B, Permissible emission of power drive systems for commercial and light industrial environment ( EN61800-3,A11 ) ( general availability, 1 st environment ) Page 7 of 34

Recommended Line Filters for Varispeed F7and E7 made by Schaffner EMV AG ( 200V, 3 phase ) Inverter Model Line Filter ( Schaffner ) Varispeed F7 Varispeed E7 Model EN 55011 CIMR-F7C20P4 CIMR-E7C20P4 B* CIMR-F7C20P7 CIMR-E7C20P7 FS 5972-10-07 B* 7 1.1 141 46 330 CIMR-F7C21P5 CIMR-E7C21P5 B* CIMR-F7C22P2 CIMR-E7C22P2 FS 5972-18-07 B* 18 1.7 141 x 46 x 330 CIMR-F7C23P7 CIMR-E7C23P7 FS 5973-35-07 B* 35 1.4 141 x 46 x 330 CIMR-F7C25P5 CIMR-E7C25P5 B* CIMR-F7C27P5 CIMR-E7C27P5 FS 5973-60-07 B* 60 3 206 x 60 x 355 CIMR-F7C2011 CIMR-E7C2011 B* CIMR-F7C2015 CIMR-E7C2015 FS 5973-100-07 A 100 4.9 236 x 80 x 408 CIMR-F7C2018 CIMR-E7C2018 A CIMR-F7C2022 CIMR-E7C2022 FS 5973-130-35 A 130 4.3 90 x 180 x 366 CIMR-F7C2030 CIMR-E7C2030 A CIMR-F7C2037 CIMR-E7C2037 FS 5973-160-40 A 160 6 120 x 170 x 451 CIMR-F7C2045 CIMR-E7C2045 FS 5973-240-37 A 240 11 130 x 240 x 610 CIMR-F7C2055 CIMR-E7C2055 A CIMR-F7C2075 CIMR-E7C2075 A CIMR-F7C2090 CIMR-E7C2090 FS 5973-500-37 A 500 19.5 300 x 160 x 564 CIMR-F7C2110 CIMR-E7C2110 A Rated Voltage Ambient Temperature : AC 240V 3phase : 45 C (max.) * max motor cable length : 10m Class B, 50m Class A Permissible emission of power drive systems for commercial and light industrial environment ( EN61800-3,A11 ) ( general availability, 1 st environment ) Page 8 of 34

APPENDIX 1-2 Recommended Line Filters for VS 606 V7 made by Schaffner EMV AG ( 230V single phase ) Inverter Model Line Filter (Schaffner) Model EN 55011 CMIR-V7CCB0P1 CMIR-V7CCB0P2 FS 5855-10-07 B 10 0.44 71 x 45 x 169 CMIR-V7CCB0P4 CMIR-V7CCB0P7 FS 5855-20-07 B 20 0.7 111 x 50 x 169 CMIR-V7CCB1P5 CMIR-V7CCB2P2 FS 5855-30-07 B 30 1.0 144 x 50 x 174 CMIR-V7CCB4P0 FS 5855-40-07 B 40 1.1 175 x 50 x 174 Rated Voltage : AC 250V single phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Recommended Line Filters for VS 606 V7 made by Schaffner EMV AG ( 200V 3 phase ) Inverter Model Line Filter (Schaffner) Model EN 55011 CMIR-V7CC20P1 CMIR-V7CC20P2 FS 5856-10-07 B 10 0.7 82 x 50 x 194 CMIR-V7CC20P4 CMIR-V7CC20P7 CMIR-V7CC21P5 FS 5856-20-07 B 16 0.84 111 x 50 x 169 CMIR-V7CC22P2 CMIR-V7CC24P0 FS 5856-30-07 B 26 0.98 144 x 50 x 174 Rated Voltage : AC 250V 3 phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Recommended Line Filters for VS 606 V7 made by Schaffner EMV AG ( 400V 3 phase ) Inverter Model Line Filter (Schaffner) Model EN 55011 CMIR-V7CC40P2 FS 5857-5-07 B 5 0.5 111 x 45 x 169 CMIR-V7CC40P4 CMIR-V7CC40P7 CMIR-V7CC41P5 FS 5857-10-07 B 10 0.75 111 x 45 x 169 CMIR-V7CC42P2 CMIR-V7CC43P0 FS 5857-20-07 B 20 1.0 144 x 50 x 174 CMIR-V7CC44P0 CMIR-V7CC45P5 FS 5857-30-07 B 30 2.0 184 x 56 x 304 CMIR-V7CC47P5 Rated Voltage : AC 480V 3 phase Page 9 of 34

Ambient Temperature : 40 C (max.) max motor cable length : 20m B Page 10 of 34

Recommended Line Filters for VS mini J7 made by Schaffner EMV AG ( 230V single phase ) Inverter Model Line Filter (Schaffner) Model EN 55011 CMIR-J7ACB0P1 CMIR-J7ACB0P2 FS 5872-10-07 B 10 0.45 71 x 45 x 169 CMIR-J7ACB0P4 CMIR-J7ACB0P7 FS 5872-20-07 B 20 0.68 111 x 50 x 169 CMIR-J7ACB1P5 Rated Voltage : AC 250V single phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Recommended Line Filters for VS mini J7 made by Schaffner EMV AG ( 200V 3 phase ) Inverter Model Line Filter (Schaffner) Model EN 55011 CMIR-J7AC20P1 CMIR-J7AC20P2 FS 5971-10-07 B 10 0.68 82 x 50 x 194 CMIR-J7AC20P4 CMIR-J7AC20P7 CMIR-J7AC21P5 FS 5971-20-07 B 16 0.84 111 x 50 x 169 CMIR-J7AC22P2 CMIR-J7AC24P0 FS 5971-30-07 B 26 0.98 141 x 50 x 174 Rated Voltage : AC 250V 3 phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Recommended Line Filters for VS mini J7 made by Schaffner EMV AG ( 400V 3 phase ) Inverter Model Line Filter (Schaffner) Model EN 55011 CMIR-J7AC40P2 FS 5871-5-07 B 5 0.57 111 x 50 x 169 CMIR-J7AC40P4 CMIR-J7AC40P7 CMIR-J7AC41P5 FS 5871-10-07 B 10 0.68 111 x 50 x 169 CMIR-J7AC42P2 CMIR-J7AC43P0 FS 5871-20-07 B 20 1.0 141 x 50 x 174 CMIR-J7AC44P0 Rated Voltage : AC V 480 3 phase Ambient Temperature : 40 C (max.) max motor cable length : 20 m B Page 11 of 34

APPENDIX 1-3 Recommended Line Filters for VS 606 V7 made by Rasmi Electronics Co.,LTD ( 230V single phase ) Inverter Model Line Filter (RASMI) Model EN 55011 CMIR-V7CCB0P1 CMIR-V7CCB0P2 RS 1010 V7 B 10 0.6 71 x 45 x 169 CMIR-V7CCB0P4 CMIR-V7CCB0P7 RS 1020 V7 B 20 1.0 111 x 50 x 169 CMIR-V7CCB1P5 CMIR-V7CCB2P2 RS 1030 V7 B 30 1.1 144 x 50 x 174 CMIR-V7CCB4P0 RS 1040 V7 B 40 1.2 175 x 50 x 174 Rated Voltage : AC 250V single phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Recommended Line Filters for VS 606 V7 made by Rasmi Electronics Co.,LTD ( 200V 3 phase ) Inverter Model Line Filter (RASMI) Model EN 55011 CMIR-V7CC20P1 CMIR-V7CC20P2 RS 2010 V7 B 10 0.8 82 x 50 x 194 CMIR-V7CC20P4 CMIR-V7CC20P7 CMIR-V7CC21P5 RS 2020 V7 B 16 1.0 111 x 50 x 169 CMIR-V7CC22P2 CMIR-V7CC24P0 RS 2030 V7 B 26 1.1 144 x 50 x 174 Rated Voltage : AC 250V 3 phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Recommended Line Filters for VS 606 V7 made by Rasmi Electronics Co.,LTD ( 400V 3 phase ) Inverter Model Line Filter (RASMI) Model EN 55011 CMIR-V7CC40P2 RS 3005 V7 B 5 1.0 111 x 45 x 169 CMIR-V7CC40P4 CMIR-V7CC40P7 CMIR-V7CC41P5 RS 3010 V7 B 10 1.0 111 x 45 x 169 CMIR-V7CC42P2 CMIR-V7CC43P0 RS 3020 V7 B 15 1.1 144 x 50 x 174 CMIR-V7CC24P0 Rated Voltage : AC 480V 3 phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Page 12 of 34

Recommended Line Filters for VS mini J7 made by Rasmi Electronics Co.,LTD ( 230V single phase ) Inverter Model Line Filter (RASMI) Model EN 55011 CMIR-J7ACB0P1 CMIR-J7ACB0P2 RS 1010 J7 B 10 0.6 71 x 45 x 169 CMIR-J7ACB0P4 CMIR-J7ACB0P7 CMIR-J7ACB1P5 RS 1020 J7 B 20 1.0 111 x 50 x 169 Rated Voltage : AC 250V single phase Ambient Temperature : 50 C (max.) max motor cable length : 20m B Recommended Line Filters for VS mini J7 made by Rasmi Electronics Co.,LTD ( 200 V 3 phase ) Inverter Model Line Filter (RASMI) Model EN 55011 CMIR-J7AC20P1 CMIR-J7AC20P2 RS 2010 J7 B 10 0.8 82 x 50 x 194 CMIR-J7AC20P4 CMIR-J7AC20P7 CMIR-J7AC21P5 RS 2020 J7 B 16 1.0 111 x 50 x 169 CMIR-J7AC22P2 CMIR-J7AC24P0 RS 2030 J7 B 26 1.1 141 x 50 x 174 Rated Voltage : AC 250V 3 phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Recommended Line Filters for VS mini J7 made by Rasmi Electronics Co., LTD ( 400 V 3 phase ) Inverter Model Line Filter (RASMI) Model EN 55011 CMIR-J7AC40P2 RS 3005-J7 B 5 1.0 111 x 50 x 169 CMIR-J7AC40P4 CMIR-J7AC40P7 CMIR-J7AC41P5 RS 3010-J7 B 10 1.0 111 x 50 x 169 CMIR-J7AC42P2 CMIR-J7AC43P0 CMIR-J7AC44P0 RS 3020-J7 B 15 1.1 141 x 50 x 174 Rated Voltage : AC 480V 3 phase Ambient Temperature : 40 C (max.) max motor cable length : 20m B Page 13 of 34

APPENDIX 1-4 Recommended Line Filters for VS-616G5/PC5/P5 made by Schaffner Elektronik AG ( 400V Class 3 Phase ) Inverter Model Line Filter ( Schaffner ) VS-616G5 VS-616PC5/P5 Model EN 55011 CIMR-G5C40P4 CIMR-P5C40P4 A CIMR-G5C40P7 CIMR-P5C40P7 FS4874-7/07 A 7 1.1 50 126 255 CIMR-G5C41P5 CIMR-P5C41P5 A CIMR-G5C42P2 CIMR-P5C42P2 A CIMR-G5C43P7 CIMR-P5C43P7 FS4874-18/07 A 18 1.7 55 142 305 CIMR-G5C44P0 CIMR-P5C44P0 A CIMR-G5C45P5 CIMR-P5C45P5 FS4874-30/07 A 30 2.0 60 150 335 CIMR-G5C47P5 CIMR-P5C47P5 A CIMR-G5C4011 CIMR-P5C4011 FS4874-42/07 A 42 3.0 70 185 329 CIMR-G5C4015 CIMR-P5C4015 A CIMR-G5C4018 CIMR-P5C4018 FS4874-55/07 A 55 3.3 80 185 329 CIMR-G5C4022 CIMR-P5C4022 FS4874-75/34 A 75 4.3 80 220 329 CIMR-G5C4030 CIMR-P5C4030 A CIMR-G5C4037 CIMR-P5C4037 FS4874-100/35 A 100 5.7 90 220 379 CIMR-G5C4045 CIMR-P5C4045 FS4874-130/35 A 130 8.0 110 240 439 CIMR-G5C4055 CIMR-P5C4055 FS4874-180/07 A 180 11 110 240 438 CIMR-G5C4075 CIMR-P5C4075 FS4874-300/99 A 300 15 300x160x564 CIMR-G5C4110 CIMR-P5C4110 A CIMR-G5C4160 CIMR-P5C4160 FS4874-400/99 A 400 20 300 160 564 CIMR-G5C4185 CIMR-P5C4185 FS4874-500/99 A 500 20 300x160x564 CIMR-G5C4220 CIMR-P5C4220 FS4874-600/99 A 600 21 300x160x564 CIMR-G5C4300 CIMR-P5C4300 FS4874-900/99 A 900 34 300 160 564 400V Class 3 Phase Foot mount Inverter Model Line Filter ( Schaffner ) VS-616G5 VS-616PC5/P5 Model EN 55011 CIMR-G5C40P4 CIMR-P5C40P4 B CIMR-G5C40P7 CIMR-P5C40P7 FS4874-7/07 A B 7 1.1 140 55 310 CIMR-G5C41P5 CIMR-P5C41P5 B ( Foot mount ) CIMR-G5C42P2 CIMR-P5C42P2 B CIMR-G5C44P0 CIMR-P5C43P7 FS4874-16/07 A B 16 2.4 140 55 310 CIMR-G5C44P0 CIMR-P5C44P0 B ( Foot mount ) CIMR-G5C45P5 CIMR-P5C45P5 FS4874-30/07 A B 30 3.3 200 55 330 CIMR-G5C47P5 CIMR-P5C47P5 B ( Foot mount ) CIMR-G5C4011 CIMR-P5C4011 FS4874-42/07 A B 42 3.3 250 70 410 CIMR-G5C4015 CIMR-P5C4015 B ( Foot mount ) Rated Voltage : AC 480V 3phase Ambient Temperature : 50 C (max.) Page 14 of 34

( 600V Class 3 Phase ) Inverter Model Line Filter ( Schaffner ) VS-616G5C Model EN 55011 CIMR-G5C51P5 CIMR-G5C52P2 CIMR-G5C53P7 FS5492-18-07 A 18 2.4 70 x 329 x 185 CIMR-G5C55P5 CIMR-G5C57P5 CIMR-G5C5011 FS5492-42-07 A 42 4.2 100 x 389 x 185 CIMR-G5C5015 Rated Voltage : AC 600V 3 phase Ambient Temperature : 50 C (max.) Page 15 of 34

APPENDIX 1-5 Recommended Line Filters for VS-616G5/PC5/P5 made by Rasmi Electronics LTD. ( 400V 3 phase ) Inverter Model Line Filter (Rasmi) VS-616G5 VS-616PC5/P5 Model EN 55011 CIMR-G5C40P4 CIMR-P5C40P4 RS-3008 G5 B 8 1.4 143 46 320 CIMR-G5C40P7 CIMR-P5C40P7 B ( Foot Mount ) CIMR-G5C41P5 CIMR-P5C41P5 B CIMR-G5C42P2 CIMR-P5C42P2 RS-3020 G5 B 20 1.8 143 46 320 CIMR-G5C44P0 CIMR-P5C44P0 B ( Foot Mount ) CIMR-G5C45P5 CIMR-P5C45P5 RS-3030 G5 B 30 3 213x51x350 CIMR-G5C47P5 CIMR-P5C47P5 B ( Foot Mount ) CIMR-G5C4011 CIMR-P5C4011 RS-3060 G5 B 60 5.3 268 56 435 CIMR-G5C4015 CIMR-P5C4015 B ( Foot Mount ) CIMR-G5C4018 CIMR-P5C4018 RS-3080 G5 A 80 7.5 180 90 350 CIMR-G5C4022 CIMR-P5C4022 A CIMR-G5C4030 CIMR-P5C4030 RS-3100 G5 A 100 13.8 200 130 420 CIMR-G5C4037 CIMR-P5C4037 RS-3120 G5 A 120 13.8 200 130 420 CIMR-G5C4045 CIMR-P5C4045 RS-3160 G5 A 160 23 200 160 480 CIMR-G5C4055 CIMR-P5C4055 RS-3180 G5 A 180 25 200x160x480 CIMR-G5C4075 CIMR-P5C4075 RS-3300 G5 A 300 25 200x160x480 CIMR-G5C4110 CIMR-P5C4110 A CIMR-G5C4160 CIMR-P5C4160 RS-3400 G5 A 400 45 250x200x588 Rated Voltage : AC 550V 3 phase Ambient Temperature : 50 C (max.) Page 16 of 34

Recommended Line Filters for VS-616 PC5 made by Schaffner Elektronik GmbH ( 230V single phase ) VS-616 PC5 Model EN 55011 CIMR-P5CB0P4 FS 4971-10/07 B 10 0.7 14.5x58x156 CIMR-P5CB0P7 FS 4971-20/07 B 20 1.0 57.6x85.5x119 CIMR-P5CB1P5 B CIMR-P5CB2P2 FS 4971-40/07 B 40 3 90x65x246 CIMR-P5CB3P7 B Rated Voltage : AC 250V single phase Ambient Temperature : 50 C (max.) Recommended Line Filters for VS-616 PC5 made by Rasmi Electronic LTD ( 230V single phase) VS-616 PC5 Model EN 55011 CIMR-P5CB0P4 RS 1010 P5 A 10 1.2 143x46x320 (Foot Mount) CIMR-P5CB0P7 RS 1020 P5 A 20 1.5 143x46x320 CIMR-P5CB1P5 A (Foot Mount) CIMR-P5CB2P2 RS 1040 P5 A 40 2.9 213x51x350 CIMR-P5CB3P7 A (Foot Mount) Rated Voltage : AC 250V single phase Ambient Temperature : 50 C (max.) Page 17 of 34

APPENDIX 1-6 Recommended Line Filters for VS mini C made by Rasmi Electronics Co.,LTD ( 230V single phase ) Inverter Model Line Filter (RASMI) VS mini C Standard type VS mini C Advanced type Model EN 55011 CMIR-XCACB0P1 CIMR-XCBCB0P1 RS1003-VSM B 3 0.55 72 41 162 CMIR-XCACB0P2 CMIR-XCBCB0P2 B (Foot Mount) CMIR-XCACB0P4 CMIR-XCBCB0P4 RS1010-VSM B 10 0.6 111 41 162 CMIR-XCACB0P7 CMIR-XCBCB0P7 B (Foot Mount) CMIR-XCACB1P5 CMIR-XCBCB1P5 RS1020-VSM B 20 1.0 134x42x162 (Foot Mount) Rated Voltage : AC 250V single phase Ambient Temperature : 50 C (max.) ( 400V 3 phase ) Inverter Model Line Filter (RASMI) VS mini C Standard type VS mini C Advanced type Model EN 55011 CMIR-XCAC40P2 CMIR-XCBC40P2 B CMIR-XCAC40P4 CMIR-XCBC40P4 RS3006-VSM B 6 0.6 112x42x162 CMIR-XCAC40P7 CMIR-XCBC40P7 B (Foot Mount) CMIR-XCAC41P5 CMIR-XCBC41P5 RS3008-VSM B 8 0.8 134x42x162 (Foot Mount) Rated Voltage : AC 460V 3 phase Ambient Temperature : 50 C (max.) Page 18 of 34

Appendix 2-1 Installation of Line Filter and CIMR - G5C40P4 to 4015 CIMR - P5C40P4 to 4015 PE L1 L2 L3 Ground Bonds ( remove any paint ) PE Line Filter Inverter Load L2 PE L1 L3 V U WPE Cable Length as short as possible Metal Plate Ground Bonds ( remove any paint ) 3~ M Motor cable, screened Page 19 of 34

Appendix 2-2 Installation of Line Filter and CIMR - G5C4018 to 4300 CIMR - P5C4018 to 4300 PE L1 L2 L3 Ground Bonds ( remove any paint ) PE Line Filter Inverter Load L2 PE L1 L3 V U WPE Cable Length as short as possible Metal Plate Ground Bonds ( remove any paint ) Page 20 of 34 3~ M Motor cable screened

Appendix 2-3 Installation of Foot - Print Typ - Filter CIMR-G5C40P4 to 4015 CIMR-P5C40P4 to 4015 L1 L2 L3 PE L1 L2 L3 PE PE U V W F I L T E R Ground Bonds Motor Cable screened 3~ M Page 21 of 34

Appendix 2-4 Installation of Line Filter and CIMR - P5CB0P4 to 3P7 PE L1 L2/N Ground Bonds ( remove any paint ) PE Line Filter Inverter Load PE L1L2 V U WPE Cable Length as short as possible Metal Plate Ground Bonds ( remove any paint ) 3~ M Motor cable screened Page 22 of 34

Appendix 2-5 Installation of Line Filter and VS - Mini L N PE L L2/N Rasmi Filter L L2/N ( Line ) ( Load ) L1 L2/N VS mini C UVW Metal Plate Motor cable screened 3~ M Page 23 of 34

APPENDIX 2-6 Installation of line filters and CIMR-F7, E7C40P4 to 4018 CIMR-F7, E7C20P4 to 2018 L1 L2 L3 PE Control Panel Shield Cable Metal Mounting Plate Filter L1 L2 L3 E Varispeed F7, E7 Ground Bonds (remove any paint) E Ground Bonds (remove any paint) Shield Cable Max. 50m Motor Cable Page 24 of 34 Motor

Page 25 of 34

Appendix 2-7 Installation of Line Filter and CIMR - F7, E7C4018 to 4300 CIMR - F7, E72018 to 2110 PE L1 L2 L3 Ground Bonds ( remove any paint ) PE Line Filter Inverter Load L2 PE L1 L3 V U WPE Cable Length as short as possible Metal Plate Ground Bonds ( remove any paint ) Page 26 of 34 3~ M Motor cable screened

APPENDIX 2-8 Installation of line filters and CIMR-V7 C40P2 to 47P5 CIMR-V7 C20P1 to 24P0 L1 L2 L3 PE Control Panel Shield Cable Metal Mounting Plate Filter L1 L2 L3 E Ground Bonds (remove any paint) V7 Series Inverter RST U V W E Ground Bonds (remove any paint) Shield Cable Max.20m Motor Cable Page 27 of 34 Motor

Page 28 of 34

APPENDIX 2-9 Installation of line filters and CIMR-V7 CB0P1 to B4P0 L N PE Control Panel Shield Cable Metal Mounting Plate Ground Bonds (remove any paint) L N E Schaffner Filter Ground Bonds (remove any paint) V7 Series Inverter R S U V W E Ground Bonds (remove any paint) Shield Cable Max.20m Motor Cable Motor Page 29 of 34

Page 30 of 34

APPENDIX 2-10 Installation of line filters and CIMR-J7 C40P2 to 44P0 CIMR-J7 C20P1 to 24P0 L1 L2 L3 PE Control Panel Shield Cable Metal Mounting Plate Ground Bonds (remove any paint) E R S T L1 L2 L3 Ground Bonds (remove any paint) Schaffner Filter J7Series Inverter U V W E Ground Bonds (remove any paint) Shield Cable Max.20m Motor Cable Motor Page 31 of 34

Page 32 of 34

APPENDIX 2-11 Installation of line filters and CIMR-J7 CB0P1 to B1P5 L N PE Shield Cable Control Panel Metal Mounting Plate E L N Schaffner Filter J7Series Inverter R S Ground Bonds (remove any paint) U V W E Shield Cable Ground Bonds (remove any paint) Max.20m Motor Cable Motor Page 33 of 34

Page 34 of 34