Bedienungsanleitung Schüttler KM. Operating Instructions Shaker KM. Mode d emploi Agitateur KM KM 2 KM 2 AKKU KM CO 2 VERSION 04 / 2016

Similar documents
Rockers &Shakers Shakers

Instruction Manual. Vortex Mixers

Magnetic Stirrer POWER DIRECT. Operating Manual Issue

Rockers, Rotators and Mini Shakers

shak er ES-X (Lab-Shaker) Shaker with separate control unit suitable for use in incubators with humidity

Installation and Connection: Installation and Operating Manual

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

ORBITAL SHAKER. Note: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Heavy Duty Orbital Shakers

Fisher Scientific. Rockers, Rotators and Shakers

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Type Maxi Mix III Rotary Shaker

3-D GYRATORY ROCKERS.

Lab Rotators and Low Cost Orbital Shakers

SciQuip Benchtop Shakers

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates.

c-go 24V/6A 24V/8A 24V/12A

L Charger. Instruction manual

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

C3 Operating Instructions

GLASSCO LABORATORY EQUIPMENTS PVT. LTD.

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

HST-BL-2830MS & HST-BL-2830MS-USA

Orbital Shaker-Incubator ES-80

MANUAL. Single charger

shak er LS-X (Lab-Shaker) Sturdy bench top shaker

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

OPERATIONS MANUAL CR Thermoreactor

Safety instructions. Always... Never... Fire hazard! Dear customer,

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

ALFRA Akku-Compact Flex Handstanze Art.-Nr / Prod.-No / N art / Nº de prod

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Operating Instructions

Swing Piston Compressors and Vacuum Pumps

Oil-free piston compressors KK and piston vacuum pumps KV

Operating instructions Solenoid interlock EX-AZM About this document. Content

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

BARNSTEAD THERMOLYNE ROTO MIX TYPE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

SPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup 3200

2016 Catalogue. Shaker. v1.0

Magnetic Stirrer MONO DIRECT. Operating Manual Issue

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Incubators. Incubators

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

Flask shaker SF1. Instructions for use Manuel d'utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung. Version 2.

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

This manual covers the following model:

Digital incubating/ refrigerating benchtop shakers.

SPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup (2700 for 50Hz models)

Angle seat valve with piston actuator VZXA-...-K

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Declaration of Conformity

Type Maxi Mix III Rotary Shaker OPERATION MANUAL AND PARTS LIST SERIES 1046 BARNSTEAD THERMOLYNE

ADN-W L 10. Battery Charger. Instruction manual

MX-S/MX-F Vortex Mixers

Power consumption In operation At rest For wire sizing

Assembly and Maintenance Manual Type ASNU

SCOPELITE TIMING LIGHT OPERATING MANUAL

Angle seat valve with diaphragm actuator VZXA-...-M

EF SERIES MOTORS OPERATION & PARTS MANUAL

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Hybex Microsample Incubator

Model 2053 Conductivity Meter Instruction Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

ELECTRICAL. Laser Distance Measure User Guide

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Type 6213 EV, 6281 EV

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

MR 3001, MR 3001 K, MR 3001 K8 MR 3002, MR 3002 S8 HG 3001, HG 3001 K

Assembly and Maintenance Manual Type AS

ADN-W BA. Li-Ion Battery Pack. Instruction manual

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Exchange of rollers from the XTS-Mover

TP + ATEX MF-Version (grease lubricated)

OPERATING INSTRUCTIONS

CYCLONE DR Bolt PP-400BP Battery Pack for PP-400DR Portable Power Pack

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

DIGITAL BATTERY TESTER 12V

k ual I24/24R Benchtop Incubator Shaker N) manual New Brunswick I24/24R Benchtop Incubator Shaker Operating manual

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL


OPERATING INSTRUCTIONS

Models P, P, P, , DANGER

Angle seat valve with piston actuator VZXA-...-K

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Transcription:

Bedienungsanleitung Schüttler KM Operating Instructions Shaker KM Mode d emploi Agitateur KM VERSION 04 / 2016 KM CO 2 KM 2 KM 2 AKKU Order-no. 0091005

Operating Instructions Shaker KM D Thank you for having chosen an original Bühler product. KM CO 2 KM 2 KM 2 AKKU 2 3

Content 1. General Notes 6 1.1 General Notes concerning areas of application and mode of operation 7 1.2 Safety Instructions 8 2. Transport Instructions 8 3. Installation and Connection 9 4. Operating the models 10 4.1 Control panel and buttons 10 4.2 Display layout 11 4.3 Operating the devices 12 4.4 Starting the device 12 4.5 Setting the speed 12 4.6 Setting the running time 12 4.7 Switching the device off 12 5. Operating modes 13 5.1 Operating mode with battery 13 5.2 Operating with power adapter 14 6. Maintenance and Servicing Instructions 14 7. CE Declaration of Conformity 15 8. Warranty 15 9. Technical Data 16 10. Basic Equipment 17 11. Rack Systems and Loading Capacities 18 11.1 Rack Systems and accessories 18 11.2 Loading Capacity of rack system with clamping strips 20 11.3 Loading Capacity of Universal Tray KM Mini 200 x 295 mm 21 11.4 Loading Capacity of Universal Tray KM 356 x 300 mm 21 1. The original version of these operating instructions is in German. Subject to technical alterations and mistakes. 4 5

1. General Notes You have chosen a Bühler high-quality product for supporting you in your work. All Bühler shakers were developed for the use in laboratories in a neutral environment. To ensure a long life and optimal operation of the device we recommend to observe the following points. Read the operating manual carefully before initial operation. The user must acquaint himself with the safety instructions and operating conditions in order to avoid damage / injuries to material and personnel. Liability and all claims under warranty end immediately in case of damages which result from misuse and / or abuse. The devices were carefully checked for perfect functioning and condition before delivery. Necessary servicing or repair work may only be done by personnel of the manufacturer (Edmund Bühler GmbH) their authorized agents personnel trained by Bühler For shipping, the device must be adequately and safely packed. If possible, use the original packing. If the device is returned to Bühler for repair, it should be cleaned and free from any harmful substances or residues. These operating instructions are protected by copyright. Modifications reserved. 1.1 General Notes concerning areas of application and mode of operation The devices can be used in all laboratory fields in which it is necessary to mix and shake homogeneously under constant and defined conditions. Areas of Application (Examples) Homogeneous mixing of different liquids as well as of solid and liquid components (e.g. nutrient solutions) Shaking of kits for diagnostic tracing reactions Solvent extraction of different phases in separating funnels for chemical investigations Evenly changing agitation of liquid phase (nutrient solutions) or gaseous phase (cell culture in Petri dishes) Coloring and decoloring of gels Thanks to their different motions and high loading capacities, and especially their variable Combifix rack systems, Bühler shakers offer solutions both for general as well as individual shaking tasks. For keeping the samples at constant temperatures, the shaker models SM 30, KS 15 and TiMix 5 can be equipped with an additional incubator hood. Temperature range: +5 C above ambient up to +50 C, optionally up to +60 C. A cooling coil for connection of an external flow-through cooler is available as an option (TH 30). Incubator Hood TH 15 (Order No. 6161 000) Incubator Hood TH 30 (Order No. 6162 000) In case of enquiries please contact the Export Sales Department Phone: +49 74 71 / 98 64-0 Fax: +49 74 71 / 98 64-75 e-mail: info@edmund-buehler.de 6 7

1.2 Safety Instructions When shaking aggressive liquids / substances there is a risk of injuries caused by splashing or spilling. Work with adequate protective equipment only. In general, avoid splashing by choosing a suitable shaking speed. Due to the movements of the device there is danger of clothing or body parts getting caught. During operation pay attention that neither clothing nor jewellery get into contact with moving parts. 3. Installation and Connection Place the shaker on a level, smooth and firm surface so that it stands firmly also at high shaking frequencies. For connection requirements and operating voltage see technical data as well as the rating plate at the back of the device. The system may only be connected to a mains with protection earth! When installing the devices make sure that they are protected against splash water. 2. Transport Instructions Safe transport of the devices is only ensured if original packaging is used. If they are bumped hard or put down roughly, damages can occur. The safety distance between the device and other instruments or a wall must be chosen in such a way that the shaking plate is freely movable and that the operating personnel cannot be injured when the shaker is switched on or during operation. If other tasks are performed by personnel in immediate vicinity of the shaker, the shaker must be switched off for reasons of safety. Do not lift the devices at the shaking plate (tray)! Transport the devices by holding them at the housing only! 8 9

4. Operating the models 4.1 Control panel and buttons 4.2 Display layout Scroll button to scroll through the display during the shaking process Up arrow button to increase the speed or runtime Down arrow button to decrease the speed or runtime On/Off button to switch the device on/off and to stop the shaking motion The speed is set in increments of 5 revolutions per minute (rpm) The running time is specified in minutes and seconds or hours and minutes (with running times over 1 hour). The maximum possible running time which can be set is 99 h 59 min. Actual value for speed, runtime and state of charge 1 (only with KM 2 Akku) 2 Selected display value (speed or remaining runtime) 3 Speed display selected 4 Runtime display selected 5 Flashing symbol t when the runtime is set 6 State of charge display (only with KM 2 Akku) 7 Runtime display in hours and minutes 10 11

4.3 Operating the devices The KM 2, KM 2 Akku and KM CO 2 devices have a modern touch technology. The devices are operated by touching the buttons on the front foil. 4.4 Starting the device The device is started by touching the button for at least 2 seconds. The device type is shown in the display during the initialisation process. The device is ready for operation at the end of the startup routine. You are now in the speed menu. The set value for the speed is 0 rpm after switching on. The remaining runtime is also set to 00:00 (= continuous running). 4.5 Setting the speed The speed is decreased or increased by pressing the, buttons. Changes to the target value are saved immediately. If the button is pressed for an extended period, the speed changes to 0 rpm. If the button is pressed during the shaking process, it stops immediately and the remaining runtime is set to 0. 4.6 Setting the runtime The runtime menu is called up by pressing the button. The value is decreased or increased by pressing the, buttons. The time is shown in mm:ss. If the set value is greater than 1 hour, the display changes to hh:mm and this is indicated by a h in the display. The set target value is started by pressing the button. With the KM 2 and KM CO 2 devices, the speed menu is called up by pressing the button again. With KM 2 Akku devices, the state of charge of the battery is firstly shown as a percentage. Pressing again takes you back to the speed menu. An activated runtime is shown in the speed menu via a flashing t. 5. Operating modes 5.1 Operating mode with battery The shaker KM 2 battery is supplied with a charged battery pack. Prior to initial operation, the charge level of the battery pack should be checked and recharged if necessary. In particular, when the battery-shaker wasn t used for a longer time, the charge level of the battery pack should be checked and recharged if necessary. To recharge the battery pack use only the supplied Power adapter. The full capacity is reached after approx. 5 hours charging time. The achievement of the full charge capacity is indicated by the LED on the charger. During charging, the LED lights red, after the full charge capacity is reached, the LED turns green. To extend the lifetime of the batteries, we recommend to connect the battery shaker to the power adapter during longer times without operation. The battery pack will not be damaged by this procedure. To protect the battery against deep discharge, the battery-shaker shuts off automatically when reaching the minimum capacity. In this case, the shaker has to be switched off at the main switch. Then connect the power adapter and switch on the shaker again. Higher ambient temperatures will reduce the lifetime of the batteries. Therefore ambient temperatures above 45 C have to be avoided. Significantly reduced working hours of battery shaker indicate that the battery pack must be replaced. To replace the battery pack first disassemble the rack system, then disassemble and remove the upper housing part.then remove the cable from the battery pack. After releasing the green rubber bands, the batteries can be removed Do not dispose used batteries into the garbage! Disposal of used batteries must be done through a local disposal system 4.7 Switching the device off The device is switched off by touching the active. button for 2 seconds whilst the device is 12 13

5.2 Operating with power adapter The charger can also be used as power supply for the battery-shaker. The battery-shaker can then be used in continuous operation The battery shaker can be used in ambient temperatures from + 4 C - + 45 C in normal atmosphere The system may only be connected to a mains with protection earth! 6. Maintenance and Servicing Instructions The devices are maintenance-free; excessive soiling should be avoided. In case of failure, please contact the Technical Service Department of the Edmund Bühler GmbH. 7. CE Declaration of Conformity We, Edmund Bühler GmbH Am Ettenbach 6 72379 Hechingen Manufacturers of this product, declare under our sole responsibility that this products corresponds to the EC directives 2006/42/EG (machinery directive), 2014/35/EU (low-voltage directive) and 2014/30/EU (EMC directive). The following harmonised standards apply: EN 61 010; EN 50 082; EN 55 014; EN 60 204; EN 60 555 Responsible for the documentation: Tobias Neher (Engineer) Am Ettenbach 6 72379 Hechingen Hechingen, May 2016 Edmund Bühler GmbH Edmund Bühler GmbH Technical Service Dept. Am Ettenbach 6 D-72379 Hechingen Phone: +49 7471 / 9864-0 Fax: +49 7471 / 9864-75 e-mail: info@edmund-buehler.de 8. Warranty The Edmund Bühler GmbH warrants that this device has the properties guaranteed by contract and that it does not have any defects which rescind its value or its use for customary and usual applications or applications foreseeen by the contract. (See General Terms and Conditions of the Edmund Bühler GmbH). The warranty period ends 24 months after delivery (date of invoice). The warranty does not include wear parts. Excluded from warranty are malfunctions caused by misuse or improper use, installation, or maintenance. Warranty ends immediately if the device is subjected to technical modifications which are not authorized in advance by Edmund Bühler GmbH. 14 15

9. Technical Data 10. Basic Equipment KM 2 KM 2 Akku KM CO 2 Article number 6113 000 6135 000 6136 000 Shaking motion orbital orbital orbital Shaking platform (w x d) mm 200 x 295 200 x 295 200 x 295 Max. load max. 2 kg max. 2 kg max. 2 kg Shaking speed 30-220 rpm 30-220 rpm 30-220 rpm Stroke 20 mm 20 mm 20 mm Runtime 1s - 100 h / 1s - 100 h / 1s - 100 h / Battery service life - min. 40 h - LED display Shaking speed and runtime Shaking speed, runtime and charge state Shaking speed and runtime CO 2 concentration 5 % 5 % 20 % Relative humidity ~ 95 % non-condensing ~ 95 % non-condensing ~ 95 % non-condensing Ambient temperature 4 C bis 45 C 4 C bis 45 C 4 C bis 45 C Electrical supply 230 V, 50/60 Hz 230 V, 50/60 Hz 230 V, 50/60 Hz Enclosure protection IP 21 IP 21 IP 21 Heat emission max. 4 W max. 4 W max. 4 W Dimensions (w x d x h) 250 x 415 x 145 250 x 415 x 145 230 x 340 x 145 Weight 8,1 kg 10,5 kg battery charger: 220 g 7,6 kg control unit: 400 g Miniature Shaker KM 2 Miniature Shaker KM 2 Akku CO 2 -Shaker KM CO 2 Basic device incl. basic platform (0007 622) and rubber mat Operating Instruction KM (0091 005) Basic device incl. basic platform (0007 622) and rubber mat, battery charger / power unit Operating Instruction KM (0091 005) Basic device incl. basic platform (0007 622) and rubber mat External control unit with connecting cable Operating Instruction KM (0091 005) 16 17

11. Rack Systems and Loading Capacities 11.1 Rack Systems and accessories Universal tray KM For secure fastening of Erlenmeyer flasks, round bottom flasks, or beakers in single stainless steel spring clamps. The drillings (28.3 mm apart) ensure flexible loading with stainless steel spring clamps. The tray is placed on the integrated basic tray and fixed. The coated tray is proof against aggressive liquids. Universal Tray KM, without spring clamps 356 x 300 mm Order No. 0052 030 Universal tray KM Mini 200 x 295 mm without spring clamps Order No. 0052 119 Clamping Strips KM for basic tray Order No. 0052 115 Spring clamps (stainless steel) for universal trays. The sizes are related to Erlenmeyer flasks, but are also suitable for round bottom flasks, beakers, etc. 10 ml 25 ml 50 ml 100 ml 250 ml 500 ml 1000 ml 2000 ml 3000 ml 5000 ml Order No. 0009 642 Order No. 0009 643 Order No. 0009 644 Order No. 0009 645 Order No. 0009 646 Order No. 0009 647 Order No. 0009 648 Order No. 0009 649 Order No. 0009 653 Order No. 0009 652 Test tube racks, stainless steel The test tube racks can be fastened either on the standard rack system between the clamping strips h, or they can be screwed on the universal tray by means of a hinged foot. With this foot it is possible to vary the angle of inclination of the test tubes. With: 68 holes à 14 mm Ø Order No. 0052 056 44 holes à 16 mm Ø Order No. 0052 057 44 holes à 18 mm Ø Order No. 0052 058 14 holes à 30 mm Ø Order No. 0052 201 Hinged foot for test tube racks, stainless steel Order No. 0052 059 18 19

11.2 Loading Capacity of rack system with clamping strips Qty (pcs) Erlenmeyer flasks 10 ml 20 1) 25 ml 16 1) 50 ml 12 1) 100 ml 9 2) 250 ml 6 2) 500 ml 4 3) 1000 ml 2 3) 2000 ml 1 4) 3000 ml 1 4) 5000 ml - Test tube racks 1 11.3 Loading Capacity of Universal Tray KM Mini 200 x 295 mm Qty (pcs) Spring clamps 10 ml 23 25 ml 15 50 ml 15 100 ml 15 250 ml 6 500 ml 4 1000 ml 3 2000 ml 1 3000 ml - 5000 ml - Test tube racks (with hinged foot) 1 1) with 5 clamping strips h (0052 115) additional 2) with 4 clamping strips h (0052 115) additional 3) with 3 clamping strips h (0052 115) additional 4) with 2 clamping strips h (0052 115) additional 11.4 Loading Capacity of Universal Tray KM 356 x 300 mm Qty (pcs) Spring clamps 10 ml 58 25 ml 29 50 ml 27 100 ml 24 250 ml 12 500 ml 8 1000 ml 5 2000 ml 2 3000 ml - 5000 ml - Test tube racks (with hinged foot) 3 20 21

www.edmund-buehler.de M A D E I N G E R M A N Y Edmund Bühler GmbH Am Ettenbach 6 72379 Hechingen / Germany Phone: +49 7471 9864-0 Fax: +49 7471 9864-75 info@edmund-buehler.de