Dual-Rod Cylinder Compact Type

Similar documents
Dual-Rod Cylinder Compact Type

Compact Slide. Series MXH ø6, ø10, ø16, ø20

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Compact Type Dual-Rod Cylinder

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Free Mount Cylinder. Series CU. A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations.

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

Series MXH. Compact Slide. ø6, ø10, ø16, ø20

Guide Table. MGF Series

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping.

Trimmer Auto Switch Series D- 7K/D-R K

CAT.ES20-53 E. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Guide Table. ø40, ø63, ø100

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Mini Free Mount Cylinder

Dual Rod Cylinder. ø6, ø10, ø15, ø20, ø25, ø32. Dual rod cylinder with guide function suitable for pick & place applications.

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Mini Free Mount Cylinder

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping.

Dual rod cylinder with guide function for pick & place applications.

Guide Table. Series MGF

Compact Cylinder/Plate type

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

180 Angular Style Air Gripper

Mini Free Mount Cylinder

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V

Compact Guide Cylinder Series MGQ

Series RSH/RS1H. To stop pallets gently. Stopper cylinder with built-in shock absorber. Heavy Duty Stopper Cylinder. ø20, ø32 ø50, ø63, ø80

Solid State Auto Switch

22mm Space required between the bottom of the cylinder body and your equipment is reduced.

Miniature Guide Rod Cylinder ±0.1. Mounting from 2 directions

Angular Style Air Gripper

Compact Guide Cylinder

Parallel Style Air Gripper: Wide Type

Heavy Duty Stopper Cylinder

Free Mount Cylinder for Vacuum

Low Profile Air Gripper. Series MHF2. Low profile air gripper with space-saving design is newly released. 5-77

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

49.5 mm Overall. 30 mm MXZ ø20. Compact. Compact Cylinder with Linear Guide. MXZ Series CAT.ES20-236A. ø12, ø16, ø20, ø25. MXZ ø20, 10 mm stroke.

Compact Guide Cylinder

Free position locking flat and compact cylinder UFCD Series

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

1.7 kg. % lighter. 1.9 kg. Air Cylinder. Weight MB1. Reduced weight by changing the shape of the rod cover and head cover.

Compact Cylinder: Standard Type Double Acting, Single Rod. How to Order 30 D F9BW. Body option <Standard stroke> Nil C M. Double acting.

Mini Rotary Actuator/Rack & Pinion Style

Compact Guide Cylinder Series MGP

2 4times. Compact Cylinder/Guide Rod Type. Guide rod. Load can be directly mounted. Mounting dimensions compatible with the CQS, CQ2 series.

SeriesMHZL2 How to Order

22 mm Space required between the bottom of the cylinder body and your equipment is reduced. 24% Up to. Compact Guide Cylinder.

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Mini Rotary Actuator/Rack & Pinion Style

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32

Compact Rotary Actuator

Low Profile Air Gripper

Series MSU. Rotary Table. High Precision. Vane Type/Sizes 1, 3, 7, 20. High precision series MSUA introduced to vane type rotary tables CAT.

2 4times. Compact Cylinder/Guide Rod Type. ±0.2 or less. Guide Rod. Load can be directly mounted.

Solid State Auto Switch D-M9#A#

2-Color Display High-Precision Digital Pressure Switch

Standard Type Dual-Rod Cylinder. ø6, ø10, ø15, ø20, ø25, ø32. How to Order

Compact Rotary Actuator

CAT.ES C. Compact Guide Cylinder. SeriesMGP. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100. New end lock type introduced to Series MGP

Air Cylinder. New RoHS. Series CJ2. are. added to the mounting types. Improved amount of mounting freedom Head cover with boss is added.

Traveling parallelism: mm. Mounting from the through-holes on the top Tapped for mounting a work piece

New cylinder body allows small auto switches to be mounted on 4 surfaces.

Rotary Actuated Air Gripper

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3)

Rotary Actuator/Vane Type

Plate Cylinder. MU Series. It is possible to mount small auto switches in 4 directions. No stick-out Easy mounting. ø25, ø32, ø40, ø50, ø63

180 Angular Style Air Gripper

Series MXH/ ø6, ø10, ø16, ø20

Rotary Table/Vane Style

Compact Rotary Actuator

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Wide Type Parallel Style Air Gripper

How to Order D 30 D M9BW. Made to Order Specifications Bore size Number of. Rod end configuration Cylinder stroke (mm) Nil

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67.

Low Differential Pressure Sensor ±1% F.S.

Traveling parallelism: mm. Mounting from the through-holes on the top. Tapped for mounting a work piece

Series MHK2. Wedge Cam Operation Slide Guide Air Gripper (2 Finger)

MHR3/MDHR3 Series. Rotary Actuated Air Gripper/3-Finger Type. Size: 10, 15 MDHR 3 10 R M9N S. How to Order. Without auto switch

Low Profile Air Gripper

Series MGPS. Compact Guide Cylinder: ø50, ø80 MGP S Z73. How to Order. Applicable auto switches. Compact Guide Cylinder.

How to Order. Lead wire length Nil L Z M9N L. Type of auto switch for detecting rotation. Nil Without auto switch. Applicable Auto Switch

Compact Cylinder: Large Bore Size Type Double Acting, Double Rod. How to Order. Cushion C Rubber bumper. Action. D Double acting

Vane Type Rotary Actuator 50, 63, 80, 100

Series MLGP. Low Profile Guide Cylinder with Lock. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100


45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

Wedge Cam Operation Slide Guide. Air Gripper/2-Finger Type ø12, ø16, ø20, ø25. Option: Stainless steel

Compact Cylinder. Series CQS CUJ CU CQS CQ2 RQ CQM MU

Compact Guide Cylinder with Lock

Air Slide Table. Traveling parallelism: mm. Mounting from the through-holes on the top. Tapped for mounting a work piece

Air Cylinder. New. New RoHS. 6 types. Series CJ2. are. added to the mounting types. 4 types 7 types

ø20, ø32 ø50, ø63, ø80 How to Order Piping direction Flange side Nil Cylinder stroke 15mm 15 (RSH20) 20mm 20 (RSH32) 30 D L Cylinder stroke

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Vane Type Rotary Actuator

/ ø6, ø10, ø16, ø20 A table cylinder suitable for short pitch mounting

3-Position Rotary Table

Transcription:

CAT.ES-7 B Dual-Rod Cylinder Compact Type New Made to Order additionally released. (For details, refer to page 22.) Auto switch can be installed from 3 directions. Reverse Series CXSJ /ø, ø0, ø, ø, ø2, ø32 Dimensions/Weight CXSJ CXS Height (CXSJ) Height (CXS) Symmetric mounting Width (CXSJ) Width (CXS) Full length (CXSJ) Full length (CXS) Reverse mounting mechanism Bolt holder Auto switch Mounting bolt Reversible Bolt holder Axial piping available (ø, ø0) Since the bolt holder is movable, the mounting bolt does not interfere with the auto switch no matter what direction it is mounted from. Bore size (mm) ø ø0 ø ø ø2 ø32 Series CXSJ CXS CXSJ0 CXS0 CXSJ CXS CXSJ CXS CXSJ2 CXS2 CXSJ32 CXS32 Note) Slide bearing, mm strokes Dimensions (mm) Height Width Full length 3. 7 9 2 2 29 30 37 32 37 2 2 73 0 9 2 + Stroke. + Stroke + Stroke 72 + Stroke 70 + Stroke 79 + Stroke + Stroke 9 + Stroke 7 + Stroke 9 + Stroke 00. + Stroke 3 9 2 + Stroke Note) Weight (kg) 0.07 0.09 0. 0.70 0.29 0. 0.37 0.0 0. 0.0.07.230 Allowable kinetic energy, allowable load, and non-rotating accuracy are equivalent to those of CXS basic type.

Dual-Rod Cylinder Compact Type Series CXSJ ø, ø0, ø, ø, ø2, ø32 How to Order Nil TN TF Port thread type M thread ø to ø2 Rc/ NPT/ ø32 G/ Piping Nil P Standard (ø to ø32) Axial (ø, ø0) Standard piping Port location Axial piping Port location CXSJ M P 0 M9BW S Compact type M L Bearing type Slide bearing Ball bushing bearing Auto switch Nil Number of auto switches Nil 2 pcs. S pc. n n pcs. Without auto switch (with built-in magnet) Refer to the below table for auto switch model numbers. Made to Order (Refer to page 2 and 22.) Bore size / Stroke (mm) Bore size Standard stroke 0,, 30, 0, 0 0 0,, 30, 0, 0, 7 0,, 30, 0, 0, 7, 00 2 32 Applicable Auto Switches/Refer to page for detailed auto switch specifications. Type Reed switch Solid state switch Special function Diagnostic indication (2-color display) Water resistant (2-color display) Electrical entry Grommet Grommet Indicator light Yes None Yes Wiring (output) 3-wire (NPN equiv.) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire Load voltage DC V AC 2 V 00 V 2 V V, 2 V 00 V or less V, 2 V 2 V 2 V V, 2 V Auto switch model Perpendicular Lead wire length symbols 0. m... Nil (Example) M9N m... M M9NWM 3 m... L M9NL m... Z M9NZ Since there are applicable auto switches other than listed, refer to page for details. For details about switch with pre-wired connector, refer to Best Pneumatics 0 Vol. catalog. Auto switches are included when shipped, (but not assembled). 2 V A9V A93V A90V M9NV M9PV M9BV M9NWV M9PWV M9BWV In-line A9 A93 A90 M9N M9P M9B M9NW M9PW M9BW F9BA Lead wire length (m) 0. (Nil) (M) 3 (L) (Z) Pre-wired connector Applicable load IC circuit IC circuit IC circuit IC circuit Solid state switches marked with are produced upon receipt of order. Relay, PLC Relay, PLC

Dual-Rod Cylinder Compact Type Series CXSJ Specifications Bore size (mm) Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Cushion Stroke adjustable range Port size 0 2 32 Air (Non-lube).0 MPa 0.7 MPa 0. MPa 0. MPa 0.0 MPa 30 to 00 mm/s 0 to 0 C (No freezing) 30 to 700 mm/s 30 to 00 mm/s Rubber bumper on both ends 0 to mm compared to the standard stroke M3 x 0. M x 0. Rc (NPT, PF) / Standard Stroke Model Standard stroke Manufacturable stroke range CXSJ CXSJ0 0,, 30, 0, 0 0,, 30, 0, 0, 7 0 to 00 0 to 0 CXSJ 0 to 0 0,, 30, 0, 0, 7, 00 CXSJ, 2, 32 0 to 0 Strokes beyond the standard stroke range are available as a special order. (mm) Made to Order (For details, refer to page 22.) Symbol Specifications XB Heat resistant cylinder ( 0 to 0 C) XB3 Low speed cylinder ( to 0 mm/s) XC Note) Made of stainless steel Intermediate stroke (with mm width XC9 spacer) XC22 Fluoro rubber seals Note) Slide bearing type only Theoretical Output Bore size Rod size Operating Piston area Operating pressure (MPa) (mm) (mm) direction (mm 2 ) 0. 0. 0.2 0.3 0. 0. CXS CXS0 CXS CXS CXS2 CXS32 0 2 OUT OUT OUT OUT OUT OUT 7 33 2 92 0.7 3.3 2. 9.2..2 3. 70. 2 9 322. 7. 0 29 2 22. 2. 2 393 3 2.0 7. 77 3 9 0 IN IN IN IN IN IN 3 00 22 7 7 0.0 2.2 7. 7. 2..2.0 0. 9.2 2 9.3 30.0 7. 227 32 2. 0.0 0 302 2. 0.0 2 23 37 03 Note) Theoretical output (N) = Pressure (MPa) x Piston area (mm 2 ) (N) 0. 0.7 33. 39.2. 2.7 9.2 0 0.0 70.0 22 27 7 377 0 23 330 9 7 29 9 2 72 Weight Model CXSJM CXSJL CXSJM0 CXSJL0 CXSJM CXSJL CXSJM CXSJL CXSJM2 CXSJL2 CXSJM32 CXSJL32 0 0.07 0.0 0.099 0.0 0.9 0.2 0.3 0.37 0.0 0..022.032 0.07 0.0 0. 0.2 0.29 0.239 0.37 0.0 0. 0..07.0 30 0.07 0.0 0.29 0.3 0. 0. 0.397 0.27 0.2 0.92.3. Standard stroke (mm) 0 0.077 0.07 0. 0. 0.2 0.2 0.23 0.3 0. 0.30.90.0 0 0.07 0.0 0.9 0. 0.22 0.302 0.9 0.79 0. 0..2.2 7 0.9 0. 0.33 0.3 0. 0. 0.73 0.73.3.39 Note) For axial piping of CXSJP- and CXSJ0P-, please add the following weight. CXSJP-: 0.009 kg, CXSJ0P-: 0.0 kg (kg) 00 0.37 0.07 0.79 0.09 0. 0..2.3 2

Series CXSJ Model Selection Caution Theoretical output must be confirmed separately, referring to the table on page 2. Vertical Mounting L L Mounting orientation m m Max. speed (mm/s) Stroke (mm) Selection graph ø ø0 ø ø ø2 ø32 Up to 0 Up to 00 Up to 00 Up to 00 All strokes z x c v Horizontal Mounting L Mounting orientation m m Refer to the caution notes below. Stroke (mm) Max. speed (mm/s) Selection graph Caution If the cylinder is horizontally mounted and the plate end does not reach the load s center of gravity, use the formula below to calculate the imaginary stroke L' that includes the distance between the load s center of gravity and the plate end. Select the graph that corresponds to the imaginary stroke L'. Imaginary stroke L' = (Stroke) + k + L k: Distance between the center and end of the plate L k ø ø0 ø ø ø2 ø32 ø ø0 ø ø ø2 ø32 Up to 0 Up to 00 Over 00, 2.7 mm mm mm mm mm Up to 30 Up to 00 Over 00 Up to 0 Up to 00 Over 00 b n m. 0 2 3 (Example) q When using CXSJM-0 and L = mm: Imaginary stroke L' = 0 + 2.7 + = 27.7 Therefore, the graph used for your model selection should be the one for CXSJM-30 n). w When using CXSJL2-0 and L = 0 mm: Imaginary stroke L' = 0 + + = 7 Therefore, the graph used for your model selection should be the one for CXSJL2-7 ). Up to 7 Up to 00 Over 00 The maximum speeds for ø to ø32 are: ø, 0: up to 00 mm/s; ø, : up to 700 mm/s; ø2, 32: up to 00 mm/s Up to 00 Up to 00 Over 00 3

Dual-Rod Cylinder Compact Type Series CXSJ Vertical Mounting Graphz V = 0 (mm/s) CXSJM CXSJL Graphx V = 00 (mm/s) CXSJM CXSJL 0 ø32 ø32 ø2 ø Weight m (kg) ø2 ø ø Weight m (kg) ø ø0 ø0 0. 0. ø ø 0.03 0 30 0 0 00 0.02 0 30 0 0 00 Overhang L (mm) Overhang L (mm) Graphc V = 00 (mm/s) CXSJM CXSJL Graphv V = 00 (mm/s) (V = 700 mm/s for ø, ) CXSJM CXSJL ø32 ø2 ø 0. ø ø 0. ø Weight m (kg) ø0 Weight m (kg) 0. ø0 0. ø ø 0.02 0 30 0 0 00 0.02 0 30 0 0 00 Overhang L (mm) Overhang L (mm) Note) V = 700 mm/s for ø, ø.

Series CXSJ Horizontal Mounting Graphb Up to 0 mm stroke 0.2 V = Up to 00 mm/s V = Up to 00 mm/s Graphn Up to 30 mm stroke 0.2 V = Up to 00 mm/s V = Up to 00 mm/s 0. 0. Weight m (kg) 0.0 0.0 0.03 Weight m (kg) 0.0 0.0 0.03 0.02 0.02 CXSJM CXSJL CXSJM CXSJL 0.0 0 0 0 0.0 0 0 0 Overhang L (mm) Overhang L (mm) Graph, V = Up to 00 mm/s; Up to 0 mm stroke CXSJM CXSJL Graph. V = Over 00 mm/s; Up to 0 mm stroke CXSJM CXSJL Weight m (kg) 0. ø32 ø2 ø Weight m (kg) 0. ø32 ø2 ø ø ø ø0 0.0 0 0 0 0 00 Overhang L (mm) 0.0 0 0 0 0 00 Overhang L (mm) ø0 Graph 2 V = Up to 00 mm/s; Up to 0 mm stroke CXSJM CXSJL Graph 3 V = Over 00 mm/s; Up to 0 mm stroke CXSJM CXSJL Weight m (kg) 0. ø32 ø2 Weight m (kg) 0. ø32 ø2 ø ø ø ø ø0 0.0 0.0 0 0 0 0 00 0 0 0 0 00 Overhang L (mm) Overhang L (mm) ø0

Dual-Rod Cylinder Compact Type Series CXSJ Graphm Up to 0 mm stroke 0.2 V = Up to 00mm/s 0. Weight m (kg) 0.0 0.0 0.03 0.02 CXSJM CXSJL 0.0 0 0 Overhang L (mm) 0 Graph 0 V = Up to 00 mm/s; Up to 30 mm stroke CXSJM CXSJL Graph V = Over 00 mm/s; Up to 30 mm stroke CXSJM CXSJL Weight m (kg) 0. ø32 ø2 Weight m (kg) 0. ø32 ø2 ø ø ø ø 0.0 0 0 0 0 00 ø0 0.0 0 0 0 0 00 ø0 Overhang L (mm) Overhang L (mm) Graph V = Over 00 mm/s; Up to 7 mm stroke CXSJM CXSJL Graph V = Over 00 mm/s; Up to 00 mm stroke CXSJM CXSJL Weight m (kg) 0. 0.0 ø0 0 0 0 0 00 ø32 ø2 ø ø Weight m (kg) 0. 0.0 0 0 0 0 00 ø32 ø2 ø ø Overhang L (mm) Overhang L (mm)

Series CXSJ Construction: Standard Piping CXSJM (Slide bearing) CXSJL (Ball bushing bearing) CXSJM CXSJL!2! w @2 @!!9 r @3 @0 t!!2! @ @2 @!!9 @ @ @3 @0 t! CXSJM0!3 y!0! eq@! u!7 o i CXSJL0!3 y!0! @7 rq@! u!7 o i @2!!9 r! @9!7 o i @2!9 r! @ @! @9!7 o i Rod cover Piston rod B-side piston Rod cover Piston rod B-side piston Component Parts: Standard Piping No. Description Material Note No. Description Material Note 2 3 Housing Piston rod A Piston rod B Aluminum alloy Carbon steel Note) Carbon steel Note) Hard anodized Hard chromium electroplated Hard chromium electroplated 7 Bumper B Piston seal Rod seal Polyurethane NBR NBR Rod cover Aluminum bearing alloy 9 O-ring NBR Head cover Aluminum alloy Anodized O-ring NBR Plate Aluminum alloy Glossy, self-coloring hard anodized 2 Seal retainer Stainless steel 7 Piston A Aluminum alloy Chromated 22 Retaining ring B Special steel Nickel plated Piston B Aluminum alloy Chromated 23 Bolt holder Stainless steel 9 Magnet Magnetic material 2 Bearing spacer Aluminum bearing alloy 0 Bumper bolt Carbon steel Nickel plated 2 Ball bushing Hexagon nut Carbon steel Nickel plated 2 Piston rod A Special steel Hard chromium electroplated 2 Bumper Polyurethane 27 Piston rod B Special steel Hard chromium electroplated 3 Hexagon socket head cap screw Chromium steel Nickel plated 2 O-ring NBR Hexagon socket head set screw Chromium steel Nickel plated 29 Piston C Stainless steel Retaining ring Special steel Nickel plated 30 Bumper holder Resin Note) Stainless steel for CXSJM. Replacement Parts: Seal Kit Model CXSJM CXSJL CXSJM0 CXSJL0 Seal kit no. CXSJM-PS CXSJL-PS CXSJM0-PS CXSJL0-PS Contents Items!7,!, and @0 from the chart above 7

Dual-Rod Cylinder Compact Type Series CXSJ Construction: Standard Piping CXSJM (Slide bearing) CXSJM!2!!0 w @2!9! r! io u!7 t! CXSJL (Ball bushing bearing) CXSJL!2!!0 @ @2!9! @ @! io u!7 t!!3 y! e q CXSJM to 32!3 y! @7 q CXSJL to 32 @2!!9 r! i o u!7 t! @2!!9 r @ #0! i o u!7 t! Rod cover Head cover Rod cover Head cover Component Parts: Standard Piping No. Description Material Note No. Description Material Note Housing Aluminum alloy Hard anodized Bumper B Polyurethane 2 Piston rod A Carbon steel Hard chromium electroplated 7 Piston seal NBR 3 Piston rod B Carbon steel Hard chromium electroplated Rod seal NBR Rod cover Aluminum bearing alloy 9 O-ring NBR Head cover Special steel O-ring NBR Plate Aluminum alloy Glossy, self-coloring hard anodized 2 Seal retainer Stainless steel 7 Piston A Aluminum alloy Chromated 22 Retaining ring B Special steel Nickel plated Piston B Stainless steel 23 Bolt holder Stainless steel 9 Magnet Magnetic material 2 Bearing spacer Resin 0 Bumper bolt Carbon steel Nickel plated 2 Ball bushing Hexagon nut Carbon steel Nickel plated 2 Piston rod A Special steel Hard chromium electroplated 2 Bumper Polyurethane 27 Piston rod B Special steel Hard chromium electroplated 3 Hexagon socket head cap screw Chromium steel Nickel plated 2 O-ring NBR Hexagon socket head set screw Chromium steel Nickel plated 29 Piston C Stainless steel Retaining ring Special steel Nickel plated 30 Bumper holder Resin Replacement Parts: Seal Kit Model Seal kit no. CXSJM CXSM-PS CXSJM CXSM-PS CXSJM2 CXSM2-PS CXSJM32 CXSM32-PS CXSJL CXSLAPS CXSJL CXSLAPS CXSJL2 CXSL2APS CXSJL32 CXSL32APS Contents Items!7,!, and!9 from the chart above

Series CXSJ Construction: Axial Piping CXSJP, CXSJ0P r w t q e o i y u Component Parts: Axial Piping No. Description Material Note 2 3 7 9 Cover Adapter Hexagon socket head cap screw Hexagon socket head plug O-ring O-ring Steel ball Steel ball Steel ball Aluminum alloy Aluminum alloy Chromium steel Chromium steel NBR NBR Special steel Special steel Special steel Hard anodized Anodized Nickel plated Nickel plated Hard chromium electroplated Hard chromium electroplated Hard chromium electroplated Parts other than those listed above are the same as those of CXSJ basic type. Clean Series There are two types of cylinders, relieving type and vacuum type, available for a clean room environment. The relieving type specification with the double-seal construction of the rod section allows the cylinder to channel exhaust through the relief port directly to the outside of a clean room environment. The vacuum type specification allows for the application of a vacuum on the rod section while forced exhaust of air takes place through the vacuum port to the outside of a clean room environment. How to Order CXSJ M Bore size Stroke Auto switch Bearing type M Slide bearing L Ball bushing bearing Only ball bushing bearing is available for clean room specification 2-. Clean room specifications Vacuum type 2 Relieving type (with specially treated sliding parts) Bore size / Stroke 0 0,, 30, 0, 0 0,, 30, 0, 0 Specifications Bore size (mm) 0 Proof pressure.0 MPa Maximum operating pressure 0.7 MPa Minimum operating pressure 0. MPa 0. MPa Ambient and fluid temperature 0 to 0 C (No freezing) Piston speed 30 to 00 mm/s Stroke adjustable range 0 to mm compared to the standard stroke Bearing type Slide bearing, Ball bushing bearing Refer to SMC Clean Series catalog for dimensions. 9

Dual-Rod Cylinder Compact Type Series CXSJ Dimensions: ø Standard Piping 0 9 + Stroke -M3 x 0. thread depth 3.. 2-M3 x 0. thread depth 3 (Piping port) Bolt holder 2 x M3 x 0. through 2 x M3 x 0. through ø3. through ø. counterbore with depth (Opposite side: Same) 2 x M3 x 0. through ø.7 2.7..2 3. Stroke 2.7.. 2 + Stroke 32 + Stroke 2 + Stroke 32 3 2 ±0.2 2 ±0.2.3 0...3 2.7 (2) ( + Stroke) 2 ±0.2 For bolt holder, refer to the back of page, Mounting. 0

Series CXSJ Dimensions: ø0 Standard Piping 2 + Stroke x M3 x 0. thread depth. Stroke 3 3. + Stroke 2 0 33 ±0.2 33 ±0.2 7. 3. 2. 2 x M x 0. thread depth (Piping port) + Stroke. + Stroke Bolt holder. 2 x M x 0.7 through 2 x M3 x 0. through ø3. through ø. counterbore with depth. (Opposite side: Same) 2 x M3 x 0. through () ( + Stroke) ø 33 ±0.2 For bolt holder, refer to the back of page, Mounting.

Dual-Rod Cylinder Compact Type Series CXSJ Dimensions: ø, ø0 Axial Piping CXSJP 0 9 + Stroke ST 7 2 + Stroke.7 3. 0.3. ST (. + Stroke) + Stroke.. + Stroke + Stroke 7. 0.3 0.3 2. 0.3 (9 + Stroke) 2 + Stroke 32 + Stroke x M. x 0.3 x L 2 x M3 x 0. thread depth 3 (Piping port) OUT IN Steel balls CXSJ0P 2 + Stroke x M. x 0.3 x L. 2 x M x 0. thread depth (Piping port) OUT IN Steel balls 2

Series CXSJ Dimensions: ø to 32 Standard Piping U R T Stroke ZZ + Stroke B D J K SS + Stroke I L Z M NN C (G) A G ± 0.2 (G) H Q E F (Through) N N (I ) (L) (Z) Bore size (mm) 2 32 A 2 73 9 B 9 2 29 37 ZZ 70 7 00. C 2 0 7 92 D 7 22 27 3 E. 3. 7. F 2 x M x 0. 2 x M x 0. 2 x M x.0 2 x M x.0 G 2 0 0 7 H 2 29 3 I J 0 2 2 K 2... L 2 30 30 M 2 x 2 x ø.3 through 2 x 2 x ø counterbore with depth.3 2 x 2 x ø. through 2 x 2 x ø9. counterbore with depth.3 2 x 2 x ø. through 2 x 2 x ø counterbore with depth.3 2 x 2 x ø. through 2 x 2 x ø counterbore with depth.3 N 2 x M x 0.7 with thread depth 2 x M x 0.7 with thread depth 2 x M x 0. with thread depth 7. 2 x M x 0. with thread depth 7. NN ø ø0 ø2 ø Q 9. 2.. R 3 T 9 9 9 0 U 2 x M x 0. with thread depth 2 x M x 0. with thread depth 2 x M x 0. with thread depth 2 x Rc/ with thread depth SS 7. 7. 70. 0. Bore size (mm) 2 32 Symbol Stroke 0. 2 30 30 0 Z 30. 0. 0 3 0 0 0 7 0 0 70 00 0 0 70 3

Dual-Rod Cylinder Compact Type Series CXSJ Auto Switch Proper Mounting Position for Stroke End Detection CXSJ, 0 A CXSJ to 32 B B C D D Operating Range Auto switch model D-A9, D-A9V D-F9BAL D-M9, D-M9V D-M9W, D-M9WV 2. 2 2. 0 3. 2 3 Bore size 3. 2 3. 7. 2.. 2 2.. The operating ranges are provided as guidelines including hystereses and are not guaranteed values (assuming approximately ±30% variations). They may vary significantly with ambient environments. Bore size (mm) 0 2 32 D-A90, D-A9 B 9. C 3. 23. 29. 37 3 7 D. 3 7 9 9. A. 2. 3. 39 0 9 A. 2. 3. 39 0 9 D-A93 B C 2 27 9 3. 3... D.... 7 D-M9, D-M9W A 9. 29. 3. 3 3 B 0. 3 0 3. C 9. 9. 2. 33 3 3 D 9. 7 0 3. (mm) 32 9 2. D-M9V, D-M9WV A 9. 29. 3. 3 3 B 0. 3 0 3. C. 2. 27. 3 3 D 7. 2 7 7. A Electrical entry direction: Inward C Electrical entry direction: Outward Bore size (mm) 0 2 32 A. 2. 3. 2 3 2 D-F9BAL B C 0. 2 0. 9. 2 2 2. 3 D. 9 3. Note ) ø: D-A90, A9, A93, F9BAL ø0: D-A90, A9, A93 Only outward electrical entry (D dimension) is available. Note 2) Minus value in D column (ø, ø, ø2, ø32) means that the auto switches are to be mounted beyond the cylinder body edges. Note 3) When setting an auto switch, confirm the operation and adjust its mounting position. Auto switch mounting dimensions CXSJ, 0 A D-A9 (Reed switch) B D-M9W D-M9 (Solid state switch) C C3 D-A9V (Reed switch) C2 D D2 D-M9V D-M9WV (Solid state switch) Auto switch model D-A9 D-M9, D-M9W D-A9V D-M9V, D-M9WV Symbol A B C, D C2, C3, D2 C, D C2, C3, D2 (mm) Bore size. 0. CXSJ to 32 A D-A9 (Reed switch) D-M9 (Solid state switch) D-M9W C C3 C2 D-A9V (Reed switch) D-M9WV (Solid state switch) Auto switch model D-M9, D-M9W D-A9V D-M9WV Symbol A C C2 C3 Bore size 2...... (mm) 32..

Series CXSJ Auto Switch Mounting Watchmaker s screwdriver Set screw Auto switch Use a watchmaker s screwdriver with a handle to mm in diameter when tightening the auto switch mounting screw. Tightening torque should be approximately 0.0 to 0. N m. Caution q Avoid proximity to magnetic objects. When magnetic substances such as iron (including flange brackets) are in close proximity to an auto switch cylinder (switch mounting side), be sure to provide a clearance between the magnetic substance and the cylinder body as shown in the drawing below. If the clearance is less than 0 mm, the auto switch may not function properly. w For CXSJ/0, the switch cannot be attached or detached from the plate side if the middle groove (indicated by arrows in the figure on the right) is used. (It will interfere with the bumper bolt at the end of the groove.) 0 mm 0 mm Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted. Normally closed (N.C. = b contact), solid state switches (D-F9G and D-F9H type) are also available. For details, refer to Best Pneumatics 0 Vol. catalog.

Series CXSJ Auto Switch Specifications Auto Switch Common Specifications Type Leakage current Operating time Impact resistance Insulation resistance Withstand voltage Ambient temperature Enclosure Standard Reed switch Solid state switch None 3-wire: 00 µa or less 2-wire: 0. ma or less.2 ms 300 m/s 2 ms or less 000 m/s 2 0 MΩ or more at 00 VDC Mega (between lead wire and case) 00 VAC for minute (between lead wire and case) 000 VAC for minute (between lead wire and case) 0 to 0 C IEC29 standard IP7, JIS C 09 waterproof construction Conforming to CE Standards Lead Wire Length Lead wire length indication (Example) D-M9BW L Lead wire length Nil 0. m M m L 3 m Z m Contact Protection Boxes: CD-P, CD-P2 <Applicable switch model> D-A9/A9V type The auto switches below do not have a built-in contact protection circuit. Therefore, please use a contact protection box with the switch for any of the following cases: q Where the operation load is an inductive load. w Where the wiring length to load is greater than m. e Where the load voltage is 00 VAC. The contact life may be shortened (due to permanent energizing conditions). Since the solid statet auto switch is a semiconductor switch which has no contacts, no contact protection box is needed. Note ) Applicable auto switch with m lead wire Z Solid state switch: Manufactured upon receipt of order as standard. Note 2) To designate solid state switches with flexible specifications, add - after the lead wire length. To designate solid state switches with flexible specifications, add - after the lead wire length. Flexible cable is used for D-M9(V), D-M9W(V) as standard. There is no need to place the suffix - to the end of part number. (Example) Note 3) m (M): D-M9W(V) only. Note ) Lead wire tolerance Lead wire length 0. m m 3 m m D-F9BAL- Tolerance ± mm ±30 mm ±90 mm ±0 mm Flexible specification Specifications Part no. Load voltage Max. load current Lead wire length Switch connection side 0. m Load connection side 0. m Internal Circuit CD-P CD-P2 Surge absorber Zener diode CD-P 00 VAC 0 VAC 2 ma 2. ma Choke coil Choke coil OUT OUT OUT (+) OUT ( ) CD-P2 2 VDC 0 ma Dimensions Connection To connect a switch unit to a contact protection box, connect the lead wire from the side of the contact protection box marked SWITCH to the lead wire coming out of the switch unit. Keep the switch as close as possible to the contact protection box, with a lead wire length of no more than meter.

Basic Wiring Auto Switch Connections and Examples Solid state 3-wire, NPN Switch main circuit Load Black Solid state 3-wire, PNP Switch main circuit Black Load 2-wire (Solid state) Switch main circuit Load 2-wire (Reed) Indicator light protective circuit etc. Load (Power supplies for switch and load are separate.) Switch main circuit Load Black Switch main circuit Load Indicator light protective circuit etc. Load Example of Connection to PLC (Programmable Logic Controller) Sink input specification 3-wire, NPN Black Switch Input Source input specification 3-wire, PNP Black Switch Input Connect according to the applicable PLC input specifications, since the connection method will vary depending on the PLC input specifications. 2-wire COM Input PLC internal circuit 2-wire COM Input PLC internal circuit Switch Switch COM PLC internal circuit COM PLC internal circuit Example of AND (Serial) and OR (Parallel) Connection 3-wire AND connection for NPN output (using relays) Switch Switch 2 Black Relay Black Relay Load Relay contact AND connection for NPN output (performed with switches only) Switch Switch 2 Black Load Black OR connection for NPN output Switch Switch 2 Black Black Load The indicator lights will illuminate when both switches are turned ON. 2-wire with 2-switch AND connection Power supply Residual Load voltage at ON = x 2 pcs. voltage voltage = 2 V - V x 2 pcs. = V Example: Power supply is 2 VDC. Internal voltage drop in switch is V. 7 Switch Switch 2 Load When two switches are connected in series, a load may malfunction because the load voltage will decrease when in the ON state. The indicator lights will illuminate if both of the switches are in the ON state. 2-wire with 2-switch OR connection Switch Switch 2 Load (Solid state) When two switches are connected in parallel, a malfunction may occur because the load voltage will increase when in the OFF state. Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = ma x 2 pcs. x 3 kω = V Example: Load impedance is 3 kω. Leakage current from switch is ma. (Reed) Because there is no current leakage, the load voltage will not increase when turned OFF. However, depending on the number of switches in the ON state, the indicator lights may sometimes dim or not light because of the dispersion and reduction of the current flowing to the switches.

Reed Switch: Direct Mounting Style D-A90(V)/D-A93(V)/D-A9(V) Grommet Caution Operating Precautions Fix the switch with the existing screw installed on the switch body. The switch may be damaged if a screw other than the one supplied is used. Auto Switch Internal Circuit D-A90(V) Reed switch Contact protection box CD-P CD-P2 OUT (±) OUT (±) Auto Switch Specifications PLC: Programmable Logic Controller D-A90/D-A90V (Without indicator light) Auto switch part no. D-A90 D-A90V D-A90 D-A90V D-A90 D-A90V Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Applicable load IC circuit, Relay, PLC Load voltage 2 VAC/DC or less VAC/DC or less 00 VAC/DC or less Maximum load current 0 ma 0 ma ma Contact protection circuit None Internal resistance Ω or less (including lead wire length of 3 m) Standard Conforming to CE Standards D-A93/D-A93V/D-A9/D-A9V (With indicator light) Auto switch part no. D-A93 D-A93V D-A93 D-A93V D-A9 D-A9V Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Applicable load Relay, PLC IC circuit Load voltage 2 VDC 00 VAC to VDC Load current range and max. load current to 0 ma to ma ma Contact protection circuit None Internal voltage drop D-A93 2. V or less (to ma)/3 V or less (to 0 ma) D-A93V 2.7 V or less 0. V or less Indicator light Red LED illuminates when turned ON. Standard Conforming to CE Standards Lead wires D-A90(V)/D-A93(V) Oilproof heavy-duty vinyl cable: ø2.7, 0. mm 2 x 2 cores (, ), 0. m D-A9(V) Oilproof heavy-duty vinyl cable: ø2.7, 0. mm 2 x 3 cores (, Black, ), 0. m Note ) Refer to page for reed switch common specifications. Note 2) Refer to page for lead wire lengths. Weight Unit: g D-A93(V) Reed switch LED diode Resistor Zener diode Contact protection box CD-P CD-P2 OUT (+) OUT ( ) Auto switch part no. Lead wire length (m) Dimensions 2. 0. 3 D-A90/D-A93/D-A9 D-A90(V) 30 2 ø2.7 D-A93(V) 30 D-A9(V) Unit: mm D-A9(V) Reed switch LED diode Resistor Reverse current prevention diode DC (+) OUT Black DC ( ) Note) q In a case where the operation load is an inductive load. w In a case where the wiring load is greater than m. e In a case where the load voltage is 00 VAC. Use the auto switch with a contact protection box in any of the above mentioned cases. (For details about the contact protection box, refer to page.). M2. x l Slotted set screw D-A90V/D-A93V/D-A9V 22 (2.) Indicator light D-A90 type comes without indicator light. 0 M2. x l Slotted set screw Most sensitive position. 22 2 ø2.7 ( ): Dimensions for D-A93 Indicator light D-A90V type comes without indicator light. 9. Load (+) DC power supply ( ). 0 Most sensitive position

Solid State Switch: Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) Grommet 2-wire load current is reduced (2. to 0 ma). Lead-free UL certified (style 2) lead cable is used. Flexibility is. times greater than the conventional model (SMC comparison). Using flexible cable as standard spec. Auto Switch Specifications PLC: Programmable Logic Controller D-M9/D-M9V (With indicator light) Auto switch part no. D-M9N D-M9NV D-M9P D-M9PV D-M9B D-M9BV Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Wiring type 3-wire 2-wire Output type NPN PNP Applicable load Power supply voltage Current consumption IC circuit, Relay, PLC, 2, 2 VDC (. to 2 V) 0 ma or less 2 VDC relay, PLC Load voltage 2 VDC or less 2 VDC (0 to 2 VDC) Load current Internal voltage drop 0 ma or less 0. V or less 2. to 0 ma V or less Leakage current 00 µa or less at 2 VDC 0. ma or less Indicator light Standard Red LED illuminates when turned ON. Conforming to CE Standards Lead wires Oilproof flexible heavy-duty vinyl cable: ø2.7 x 3.2 ellipse D-M9B(V) 0. mm 2 x 2 cores D-M9N(V), D-M9P(V) 0. mm 2 x 3 cores Note ) Refer to page for solid state switch common specifications. Note 2) Refer to page for lead wire lengths. Weight Unit: g Caution Operating Precautions Fix the switch with the existing screw installed on the switch body. The switch may be damaged if a screw other than the one supplied is used. Auto Switch Internal Circuit D-M9N(V) Auto switch part no. 0. Lead wire length 3 (m) Dimensions D-M9 2. D-M9N(V) D-M9P(V) Mounting screw M2. x l Slotted set screw Indicator light D-M9B(V) 7 3 3 Unit: mm DC (+) Switch main circuit OUT Black 2. 22 2.7 3.2 D-M9P(V) Switch main circuit DC ( ) DC (+) OUT Black DC ( ) D-M9V Most sensitive position 22 Mounting screw M2. x l Indicator light Slotted set screw 2 3.2 2.7 9. 2.. D-M9B(V) OUT (+) 2. Most sensitive position Switch main circuit 9 OUT ( )

2-Color Indication Solid State Switch: Direct Mounting Style D-M9NW(V)/D-M9PW(V)/D-M9BW(V) Grommet 2-wire load current is reduced (2. to 0 ma). RoHS compliant UL certified (style 2) lead cable is used. Flexibility is. times greater than the conventional model (SMC comparison). Using flexible cable as standard spec. The optimum operating position can be determined by the color of the light. (Red Green Red) Auto Switch Specifications PLC: Programmable Logic Controller D-M9W/D-M9WV (With indicator light) Auto switch part no. D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV Electrical entry direction Wiring type Output type In-line Perpendicular 3-wire NPN In-line Perpendicular PNP In-line Perpendicular 2-wire Applicable load Power supply voltage Current consumption IC circuit, Relay, PLC, 2, 2 VDC (. to 2 V) 0 ma or less 2 VDC relay, PLC Load voltage Load current 2 VDC or less 0 ma or less 2 VDC (0 to 2 VDC) 2. to 0 ma Internal voltage drop Leakage current 0. V or less at 0 ma (2 V or less at 0 ma) 00 µa or less at 2 VDC V or less 0. ma or less Indicator light Standard Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Conforming to CE Standards Lead wires Oilproof flexible heavy-duty vinyl cable: ø2.7 x 3.2 ellipse D-M9BW(V) 0. mm 2 x 2 cores D-M9NW(V), D-M9PW(V) 0. mm 2 x 3 cores Note ) Refer to page for solid state switch common specifications. Note 2) Refer to page for lead wire lengths. Weight Unit: g Auto Switch Internal Circuit D-M9NW(V) Switch main circuit DC (+) OUT Black DC ( ) Auto switch part no. 0. Lead wire length (m) 3 Dimensions D-M9W D-M9NW(V) Mounting screw M2. x l Slotted set screw D-M9PW(V) D-M9BW(V) 7 3 3 3 Unit: mm D-M9PW(V) DC (+) 2. Indicator light Switch main circuit OUT Black 2. 22 2.7 D-M9BW(V) DC ( ) OUT (+) OUT ( ) Indicator light / Display method Operating range Switch main circuit ON OFF D-M9WV 3.2 Most sensitive position 22 Indicator light Mounting screw M2. x l Slotted set screw 2 3.2 2.. Most sensitive position 2.7 Display Red Green Red Optimum operating position 9. 2.

Water Resistant 2-Color Indication Solid State Switch: Direct Mounting Style D-F9BAL Grommet Water (coolant) resistant type The optimum operating position can be determined by the color of the light. (Red Green Red) Caution Operating Precautions Please consult SMC if using coolant liquid other than water based solution. Auto Switch Specifications D-F9BAL (With indicator light) Auto switch part no. Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Indicator light Standard PLC: Programmable Logic Controller D-F9BAL 2-wire 2 VDC relay, PLC 2 VDC (0 to 2 VDC) to 30 ma V or less ma or less at 2 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Conforming to CE Standards Lead wires Oilproof heavy-duty vinyl cable: ø2.7, 2 cores (, ) x 0. mm 2, 3 m Note ) Refer to page for solid state switch common specifications. Note 2) Refer to page for lead wire lengths. Weight Unit: g Auto Switch Internal Circuit Auto switch part no. 0. Lead wire length 3 (m) D-F9BA 37 7 Switch main circuit OUT (+) Dimensions Unit: mm OUT ( ) Indicator light / Display method M2. x l Slotted set screw Indicator light ø2.7 Operating range ON OFF Display Red Green Red Optimum operating position Most sensitive position 2

Made to Order Symbol Heat Resistant Cylinder ( 0 to 0 C) XB Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 0 C from 0 C. How to Order Standard model no. Specifications Ambient temperature range Seals material Grease Specifications other than above and external dimensions Note ) Operate without lubrication from a pneumatic system lubricator. Note 2) Please contact SMC for details on the maintenance intervals for this cylinder, which differs from those of the standard cylinder. Note 3) In principle, it is impossible to make built-in magnet type and the one with auto switch. (Please contact SMC for the availability with auto switch.) Note ) Piston speed is ranged from 0 to 00 mm/s. Warning Precautions Made of Stainless Steel Specifications Parts changed to stainless steel Specifications other than above and external dimensions Heat resistant cylinder XB 0 to 0 C Fluoro rubber Heat resistant grease Same as standard product Be aware that smoking cigarettes, etc. after your hands have come into contact with the grease used in this cylinder can create a gas that is hazardous to humans. 3 How to Order CXSJM Standard model no. Piston rod Hexagon socket head cap screw Made of stainless steel Retaining ring Hexagon socket head set screw Standard model no. XC Same as standard product Bumper bolt Hexagon nut Symbol Fluoro Rubber Seals XC22 The seal material is changed to fluoro rubber that has high chemical resistance. XC22 Symbol XC Note) Spring steel is used for the retaining ring on the head cover for ø. (Stainless steel is not used.) How to Order Piston rod, Retaining ring, Hexagon socket head cap screw, Hexagon socket head set screw, Bumper bolt, Hexagon nut Fluoro rubber seals Specifications Rod seal, Piston seal, O-ring Fluoro rubber Specifications and dimensions other than above are the same as standard product. Symbol 2 Low Speed Cylinder XB3 Even if driving at lower speeds to 0 mm/s (CY: 7 to 0 mm/s), there would be no stick-slip phenomenon and it can run smoothly. How to Order Standard model no. Specifications Piston speed External dimensions Specifications other than above Low speed cylinder XB3 to 0 mm/s Same as standard product Same as standard product Note ) Operate without lubrication from a pneumatic system lubricator. Note 2) For speed adjustment, use speed controllers for controlling at lower speeds. (Series AS-FM/AS-M) Symbol Intermediate Stroke (Spacer type) XC9 Dealing with the intermediate stroke by installing a spacer with the standard stroke cylinder. How to Order Standard model no. Applicable Stroke Intermediate stroke (Spacer type) XC9 ø, 2, 3, ø0, 2, 3,, 70 ø ø, 2, 3,, 70, 9 ø2 ø32 Dealing with it by installing a mm width spacer with the standard stroke cylinder. Specifications other than above are the same as standard type. External dimensions are the same as standard stroke products added by mm for the required stroke. Please consult with SMC when stroke other than applicable stroke is required. 22

Series CXSJ Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO Note ), JIS B 370 Note 2) and other safety practices. Explanation of the Labels Labels Danger Warning Explanation of the labels In extreme conditions, there is a possible result of serious injury or loss of life. Operator error could result in serious injury or loss of life. Caution Operator error could result in injury Note 3) or equipment damage. Note ) Note ) ISO : Pneumatic fluid power General rules relating to systems Note 2) JIS B 370: General Rules for Pneumatic Equipment Note 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalization or hospital visits for long-term medical treatment. Note ) Equipment damage refers to extensive damage to the equipment and surrounding devices. Selection/Handling/Applications. The compatibility of the pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. (Understanding JIS B 370 General Rules for Pneumatic Equipment, and other safety rules are included.) 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed.. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driven objects have been confirmed. 2. When equipment is removed, confirm that safety process as mentioned above. Turn off the supply pressure for this equipment and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity). 3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc.. If the equipment will be used in the following conditions or environment, please contact SMC first and be sure to take all necessary safety precautions.. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, requiring special safety analysis.. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. And, examine the devices periodically if they function normally or not. Exemption from Liability. SMC, its officers and employees shall be exempted from liability for any loss or damage arising out of earthquakes or fire, action by a third person, accidents, customer error with or without intention, product misuse, and any other damages caused by abnormal operating conditions. 2. SMC, its officers and employees shall be exempted from liability for any direct or indirect loss or damage, including consequential loss or damage, loss of profits, or loss of chance, claims, demands, proceedings, costs, expenses, awards, judgments and any other liability whatsoever including legal costs and expenses, which may be suffered or incurred, whether in tort (including negligence), contract, breach of statutory duty, equity or otherwise. 3. SMC is exempted from liability for any damages caused by operations not contained in the catalogs and/or instruction manuals, and operations outside of the specification range.. SMC is exempted from liability for any loss or damage whatsoever caused by malfunctions of its products when combined with other devices or software. Back page

Series CXSJ Auto Switches Precautions Be sure to read this before handling. Warning. Confirm the specifications. Read the specifications carefully and use this product appropriately. The product may be damaged or malfunction if it is used outside the range of specifications of current load, voltage, temperature or impact. We do not guarantee any damage in any case the product is used outside of the specification range. 2. Pay attention to the length of time that a switch is on at an intermediate stroke position. When an auto switch is placed at an intermediate position of the stroke and a load is driven at the time the piston passes, the auto switch will operate. However if the speed is too great, the operating time will be shortened and the load may not operate properly. The maximum detectable piston speed is: V (mm/s) = Auto switch operating range (mm) Load operating time (ms) 3. Keep wiring as short as possible. <Reed switch> In the case of an auto switch with no contact protection circuit: As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the product s life. (The switch will stay ON all the time.) Use a contact protection box when the wire length is m or longer. <Solid state switch> Although wire length should not affect switch function, use a wire 00 m or shorter. If the wiring is longer it will likely increase noise although the length is less than 00 m. When the wire length is long, we recommend attaching the ferrite core to the both ends of the cable to prevent excess noise.. Do not use a load that generates surge voltage. If a surge voltage is generated, the discharge occurs at the contact, possibly resulting in the shortening of product life. <Reed switch> If driving a load such as a relay that generates a surge voltage, use a contact protection box. <Solid state switch> Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. Since the solid state auto switch is a semiconductor switch which has no contacts, no contact protection box is needed.. Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance and confirm proper operation.. Do not make any modifications (including exchanging the printed circuit boards) to the product. It may cause human injuries and damage. Design and Selection x 000 Caution. Take precautions when multiple actuators are used close together. When two or more actuators are lined up in close proximity to each other, magnetic field interference may cause the switches to malfunction. Maintain a minimum cylinder separation of 0 mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) The auto switches may malfunction due to the interference from the magnetic fields. 2. Take note of the internal voltage drop of the switch. <Reed switch> ) Switches with an indicator light (Except D-A9, A9V) If auto switches are connected in series as shown below, take note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.) [The voltage drop will be n times larger when n auto switches are connected.] Even though an auto switch operates normally, the load may not operate. Load In the same way, when operating under a specified voltage, although an auto switch may operate normally, the load may not operate. Therefore, the formula below should be satisfied after confirming the minimum operating voltage of the load. Supply voltage Internal voltage drop of switch > Minimum operating voltage of load 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model D- A90, A90V). <Solid state switch> 3) Generally, the internal voltage drop will be greater with a 2- wire solid state auto switch than with a reed switch. Take the same precautions as in ). For details, refer to Example of AND (serial) and OR (parallel) connection on page 7. Also, note that a 2 VDC relay is not applicable. 3. Pay attention to leakage current. <Solid state switch> With a 2-wire solid state auto switch, current (leakage current) flows to the load to operate the internal circuit even when in the OFF state. Operating current of > Leakage current load (OFF condition) If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification will not be satisfied. Moreover, leakage current flow to the load will be n times larger when n auto switches are connected in parallel. Refer to page 7. Back page 2

Series CXSJ Auto Switches Precautions 2 Be sure to read this before handling. Design and Selection Caution. Ensure sufficient clearance for maintenance activities. When designing an application, be sure to allow sufficient clearance for maintenance and inspections.. Use the cylinder and switch in proper combination. The auto switch is pre-adjusted to activate properly for an auto-switch-capable SMC cylinder. If the auto switch is mounted improperly, used for another brand of cylinder or used after the alternation of the machine installation, the switch may not activate properly. Mounting and Adjustment Warning. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. 2. Do not drop or bump. Do not drop, bump or apply excessive impacts (300 m s 2 or more for reed switches and 000 m s 2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 3. Mount switches using the proper fastening torque. When a switch is tightened beyond the range of fastening torque, the mounting screws, mounting bracket or switch may be damaged. On the other hand, tightening below the range of fastening torque may allow the switch to slip out of position. (For mounting and moving auto switches, tightening torque, etc., refer to each series.). Mount a switch at the center of the operating range. Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON). (The mounting position shown in a catalog indicates the optimum position at stroke end.) If mounted at the end of the operating range (around the borderline of ON and OFF), operation will be unstable or the service life will be shortened. <D-M9(V)> When the D-M9(V) auto switch is used to replace old series auto switch, it may not activate depending on operating condition because of its shorter operating range. Such as Application where the stop position of actuator may vary and exceed the operating range of the auto switch, for example, pushing, pressing, clamping operation, etc. Application where the auto switch is used for detecting an intermediate stop position of the actuator. (In this case the detecting time will be reduced.) In these applications, set the auto switch to the center of the required detecting range. Mounting and Adjustment Caution. Do not carry an actuator by the auto switch lead wires. Never carry a cylinder (actuator) by its lead wires. This may not only cause broken lead wires, but it may cause internal elements of the switch to be damaged by the stress. 2. Fix the switch with appropriate screw installed on the switch body. If using other screws, switch may be damaged. Wiring Warning. Confirm proper insulation of wiring. Be certain that there is no faulty wiring insulation (contact with other circuits, ground fault, improper insulation between terminals, etc.). Damage may occur due to excess current flow into a switch. 2. Do not wire with power lines or high voltage lines. Wire separately from power lines or high voltage lines, avoiding parallel wiring or wiring in the same conduit with these lines. Control circuits, including auto switches, may malfunction due to noise from these other lines. Caution. Avoid repeatedly bending or stretching lead wires. Repeated bending or tensile force applied to the lead wire may cause the sheath to fall off or disconnection of the wire. If bending or tensile force are not avoidable, fix the lead wire close to the switch and allow a bend radius of R0 to 0 mm or larger. Please consult SMC for details. Stress and tensile force applied to the connection between the cable and switch increases the possibility of the sheath to fall off or disconnection. Fix the cable in the middle so that it is not movable in the area where it connects with the switch. 2. Be sure to connect the load before power is applied. <2-wire type> If the power is turned ON when an auto switch is not connected to a load, the switch will be instantly damaged because of excess current. It is the same as when the 2-wire brown cord (+, output) is directly connected to the (+) power supply terminal. Back page 3

Series CXSJ Auto Switches Precautions 3 Be sure to read this before handling. Wiring Caution 3. Do not allow short circuit of loads. <Reed switch> If the power is turned ON with a load in a short circuited condition, the switch will be instantly damaged because of excess current flow into the switch. <Solid state switch> Model D-M9(V), F9BA and all models of PNP output type switches do not have built-in short circuit prevention circuits. If loads are short circuited, the switches will be instantly damaged, as in the case of reed switches. Take special care to avoid reverse wiring with the power supply line (brown) and the output line (black) on 3-wire type switches. The 2-wire type brown lead wire is for output, and the 3-wire type lead wire with the same brown color is the + power supply line. If the 2-wire type brown lead wire is connected to the location where the 3-wire type brown lead wire has been wired, a load short (no load) will result, causing overcurrent and damage to the switch.. Avoid incorrect wiring. <Reed switch> A 2 VDC switch with indicator light has polarity. The brown lead wire is (+) and the blue lead wire is ( ). ) If connections are reversed, a switch will operate, however, the light emitting diode will not light up. Also note that a current greater than that specified will damage a light emitting diode and it will no longer operate. Applicable models: D-A93, A93V <Solid state switch> ) If connections are reversed on a 2-wire type switch, the switch will not be damaged if protected by a protection circuit, but the switch will always stay in an ON state. However, it is still necessary to avoid reversed connections, since the switch could be damaged by a load short circuit in this condition. 2) If connections are reversed (power supply line + and power supply line ) on a 3-wire type switch, the switch will be protected by a protection circuit. However, if the power supply line (+) is connected to the blue wire and the power supply line ( ) is connected to the black wire, the switch will be damaged. <D-M9(V)> The D-M9(V) does not have built-in short circuit protection circuit. Be aware that if the power supply connection is reversed (e.g. (+) power supply wire and ( ) power supply wire connection is reversed), the switch will be damaged.. When the cable sheath is stripped, confirm the stripping direction. The insulator may be split or damaged depending on the direction. (D-M9(V) only) Operating Environment Warning. Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside actuators will become demagnetized. 3. Do not use in an environment where the auto switch will be in water or continually exposed to water. Although switches satisfy IEC standard IP7 construction (JIS C 09: waterproof construction), do not use switches in applications where continually exposed to water splash or spray. Poor insulation or swelling of the potting resin inside switches may cause malfunction.. Do not use in an environment with oil or chemicals. Please consult SMC if auto switches will be used in an environment with coolant, cleaning solvent, various oils or chemicals. If auto switches are used under these conditions for even a short time, they may be adversely affected by improper insulation, malfunction due to swelling of the potting resin, or hardening of the lead wires.. Do not use in an environment with temperature cycles. Please consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally.. Do not use in an environment where there is excessive impact shock. <Reed switch> When excessive impact (300 m/s 2 or more) is applied to a reed switch during operation, the contact point will malfunction and generate or cut off a signal momentarily ( ms or less). Please consult SMC regarding the need to use a solid state switch depending upon the environment. 7. Do not use in an area where surges are generated. <Solid state switch> When there are units (solenoid type lifter, high frequency induction furnace, motor, radio equipment etc.) which generate large surges or electromagnetic waves in the area around actuators with solid state auto switches, this may cause deterioration or damage to the switches. Avoid sources of surge generation and crossed lines. Recommended Tool Model name Wire stripper Model no. D-M9N-SWY Stripper for a round cable (ø2.0) can be used for a 2-wire type cable. Back page