Technical Data Sheets

Similar documents
Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

TLE Series UPS 400/500 kw With eboost Technology

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

POWER kva

POWER kva

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

EFFEKTA Power Supplies

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET KVA UPS Systemss

PowerValue 11/31 T kva

ConceptpowerTM Modular kVA

PowerScale TECHNICAL SPECIFICATIONS

PowerScale kva Technical Specifications

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

1.1 GENERAL CHARACTERISTICS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

POWERTRONIX QUASAR 5-40 KVA

Master Plus kva

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TECHNICAL SPECIFICATIONS

Master MPS kva kva 3:1 3:3 VFI TYPE

Industrial PFC UPS System

AME. Rectifier - Battery charger. Industrial applications: Key features:

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Master Plus kva

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Master MPS kva kva 3:1 3:3 VFI TYPE

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Three Phase UPS Systems Range: 10 to 500kVA

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

UPS Multi Sentry 10-20kVA

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Power+ CLASSIC. 20/30 kva, 3x208 Vac

MASTERYS IP+ 10 to 80 kva

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Green Power 2.0 MASTERYS GP

DC POWER SUPPLY SYSTEMS

Master DIALOG INDUSTRY RANGE

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

D Series: UPS UPTO - 300KVA - Three / Three Phase

EATON 9315 UPS 200 TO 300 KVA Specifications

60 to 160 kva.

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

Aurora Single Phase Emergency Lighting Inverters

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

Liebert. FP 50Z kva

Industrial Chargers and

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

SG Series 225 & 300. GE Digital Energy Power Quality. User Manual. imagination at work. Uninterruptible Power supply. 225 & 300 kva / 480Vac UL / S2

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Marketing Management Team of Europe

UPS5000-E (25-75 kva) Series

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Master MPS kva kva 3:1 3:3 VFI TYPE

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Transcription:

GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series 60-80 kva PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com GE imagination at work

Model: SG-CE Series 60 80 100 120 kva PurePulse / Series 1 Issued by: Product Document Department Riazzino - CH Date of issue: 15.12.2008 File name: TDS_SGS_PCE_60K_M12_1GB_V020 Revision: 2.0 Identification No. Up-dating Revision Concern Date 2.0 ECN 1257 (Short-circuit characteristic) + 50Ah battery cabinet 15.12.2008 COPYRIGHT 2008 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6

GENERAL DATA Topology VFI, double conversion with integrated transformer Nominal output power from PF=0.6 lag. to 0.9 leading KVA/kW 60/54 80/72 100/90 120/108 Overall efficiency at 100% load PF=0.9 lag. in VFI mode % 91.4 91.4 91.7 91.2 Overall efficiency at 75% load PF=0.9 lag. in VFI mode +/-0.2% (guaranteed 91.8 91.8 92.0 91.8 Overall efficiency at 50% load PF=0.9 lag. in VFI mode values) 91.9 91.9 91.9 92.1 Overall efficiency at 100% load in SEM mode +/-0.2% % 97.9 97.9 97.8 97.9 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. & charged battery kw 4.52 6.02 7.24 9.26 Cooling air (25 C 30 C) m 3 /h 1320 1760 2115 2710 Audible noise level db(a) 63 63 63 63 Battery type Valve regulated lead-acid (VRLA), vented lead-acid, NiCd Operating temperature range UPS: 0 C 40 C Storage temperature range -25 C +55 C Relative Humidity Max. 95% (non-condensing) Max. altitude without power derating 1000m Power derating (according to EN/IEC 62040-3) 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% Protection degree IP 20 (IEC 60529) s EN/IEC 62040, CE marking EMC EN/IEC 62040-2 (Category C2 as option), Burst & Surges 2kV L-L, 4kV L-PE Electrostatic discharge immunity 8kV contact / 15kV air discharge Internal protection All live parts shrouded Transport Cabinet suitable for handling by forklift Colour RAL 9003 (white), bottom air grids RAL 7021 (black) Installation Can be positioned against a wall and floor fixed Service access Front and top access only External cable connections Bottom at front of the cabinet (top as option) Cooling Enforced ventilation with fan speed control Paralleling (RPA version) Up to 6 units parallelable for redundancy or capacity in RPA configuration (optional). RECTIFIER Rectifier bridge Three phase, IGBT rectifier, PurePulse technology, overtemperature protection input voltage Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 340V 460V Other input voltages On request Input frequency 50/60 Hz +/-10% (45 66 Hz) Power factor 0.99 Input current THD 2% at 100% load <2.5% at 75% load <3% at 50% load Inrush current Limited by soft-start circuit Power walk-in 15 seconds Output voltage tolerance +/- 1% DC voltage ripple <1% DC current ripple Max. 5% the battery capacity [Ah], expressed in A Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Programmable Input power data kva 60 80 100 120 Input power at inverter nominal load and charged battery at PF=0.8 lag. 52.5 70.0 87.3 105.3 kw at PF=0.9 lag. 59.1 78.8 98.2 118.5 Max. input power at inverter nominal load and max. battery recharge current (programmable) kw 66.0 87.8 109.5 131.6 Max. battery charging current (programmable) at at PF=0.8 lag. 33 44 55 65 A the beginning of battery recharge at nominal load at PF=0.9 lag. 17 22 27 32 UPS OUTPUT POWER CAPABILITY Output UPS power versus power factor for: Inductive loads Resistive loads Capacitive loads Modifications reserved Page 3/6

BATTERY Battery type Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd Float voltage at 20 C 400V 436V (dependent on the number of cells) VRLA at 2.27V/cell: 177 192 cells Vented lead acid at 2.23V/cell, no boostcharge: 180 195 cells Number of cells Vented lead acid at 2.23V/cell, with boostcharge at 2.35 V/cell: 180 185 cells NiCd at 1.41V/cell, no boostcharge: 284 309 cells NiCd at 1.41V/cell, with boostcharge at 1.55 V/cell: 281 cells Min. discharge voltage (programmable) Up to 310V (dependent on the number of cells) Recharge time <5 hours up to 90% of battery capacity Battery to earth fault detection Automatic and manual battery test Automatic battery contactor Battery power data kva 60 80 100 120 DC power at full load and PF=0.8 lag. kw 50.8 67.8 84.7 101.6 DC power at full load and PF=0.9 lag. kw 57.2 76.2 95.3 114.3 DC power at full typical computer load (PF=0.66 lag.) kw 41.9 55.9 69.9 83.8 Matching battery cabinets See optional features on page 5 INVERTER Nominal output power at PF=0.6... 0.9 lag. 60 80 100-120 kva Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge SVM (Space Vector Modulation) and IGBT technology Output transformer (for galvanic separation) Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 3% - dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 5 ms - output voltage THD for 100% linear load... Max. 1.5% - output voltage THD for 100% non-linear load (EN 62040) Max. 3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 3% Overload capability (at 25 C ambient temperature) 125% - 10 minutes, 150% - 1 minute Electronic short-circuit protection, current limit to: Short-circuit characteristic 2.7 times In for 200 ms between phase and phase 4.0 times In for 200 ms between phase and N/PE MTCB clearance capability (selectivity) 20% In within 5-10ms (with MTCB class C or magn. trip at max. 10In) Crest factor >3:1 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass Separate (dual input-recommended) or common to the rectifier input - Static switch (SCR) on bypass - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass +/- 10% (adjustable) 200% for 5 minutes & 45 times In for 10 ms, non repetitive INTERFACING 6 programmable signalling voltage-free contacts - information for easy integration and signalling (available on Delta and block terminals) - 27 user settable signals Serial channel RS232 (on Delta 9 pin connector) - EMERGENCY POWER OFF (n/c contact, customer supplied) Input signals - GEN ON (emergency power supply ON, n/o contact, customer supplied) - 1 auxiliary signal, with settable functionality Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6

SGSE_060-120_S1_OPT_cabinet 500_01 SGSE_160-300_OPT_B1 cabinet_01 SGSE_160-300_OPT_ B2 cabinet_01 FRONT PANEL CONTROLS, SIGNALS AND ALARMS The control panel, positioned on the UPS front door, acts as the UPS user interface and comprises of the following elements: Back lit Graphic Display (LCD) with the following characteristics: Multilanguage communication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch; Graphic diagram indicating UPS status. Command keys and parameters setting. UPS status control LED. OPTIONS COMMUNICATION: 1. Additional Customer Interface Card 2. Advanced SNMP Card 3. GE Power Diagnostics 4. GE Data Protection 5. RSB - Remote Signalling Box (cable for connection to UPS not included) BUILT-IN UPS OPTIONS: 1. RPA kit 2. Auxiliary Power Supply (APS) 24Vdc OPTIONS IN ADDITIONAL CABINETS: Dimensions (WxDxH): 350x850x1900mm 500x850x1900mm 850x850x1900mm 1500x850x1900mm 1. Rectifier or bypass or UPS input transformer 2. EMC filter EN/IEC 62040-2 Category C2 (Class A) 3. Top entry cables cabinet 4. Special voltages: input and/or output On request 5. Empty battery cabinets 6. Battery cabinet 50Ah (without fuses) 7. Battery cabinet 75Ah (without fuses) BATTERY TABLE 8. Battery cabinet 2x50Ah (without fuses) UPS At 75% load PF 0.8 At 100% load PF 0.8 9. Battery cabinet 2x75Ah (without fuses) (kva) 50Ah 75Ah 2x50Ah 2x75Ah 4x50Ah 4x75Ah 50Ah 75Ah 2x50Ah2x75Ah4x50Ah4x75Ah 50Ah 670 kg 75Ah 1000 kg 2x50Ah 1170 kg 2x75Ah 1800 kg 60 13 min. 22 min. 31 min. 53 min. 77 min. 139 min. 9 min. 16 min. 22 min. 36 min. 53 min. 95 min. 80 9 min. 15 min. 22 min. 36 min. 52 min. 95 min. 6 min. 11 min. 16 min. 26 min. 36 min. 70 min. 100 _ 12 min. 17 min. 27 min. 37 min. 65 min. _ 8 min. 12 min. 20 min. 28 min. 45 min. 120 _ 9 min. 13 min. 22 min. 32 min. 51 min. _ 6 min. 9 min. 16 min. 22 min. 36 min. 500x850x1900mm 850x850x1900mm 1500x850x1900mm These runtimes can be achieved only with our High Rate batteries. EXTERNAL ACCESSORIES: 1. ISM - Intelligent Synchronization Module 350mm x 190mm x 584mm 2. Parallel output cabinet with centralized maintenance bypass On request 3. Battery fuses box On request Modifications reserved Page 5/6

TECHNICAL DATA SG-CE Series 60 & 80 kva SGSE_060-080_S1_UPS dimensions_ge_01 UPS cabinet WEIGHTS (kg) Additional cabinet SG-CE Series 100 & 120 kva SGSE_100-120_S1_UPS dimensions_ge_01 1'900mm UPS Rating (kva) UPS standard (kg) Floor loading UPS standard (kg/m 2 ) Rectifier or bypass transformer (500x850x1900mm) EMC filter EN/IEC 62040-Cat. C2 (350x850x1900mm) Top entry cables cabinet (350x850x1900mm) 1'900mm 60 550 kg 995 340 kg 110 kg 70 kg 80 630 kg 1140 380 kg 110 kg 70 kg 850mm 650mm Dimensions (WxDxH): 650mm x 850mm x 1900mm 100 860 kg 1212 450 kg 125 kg 75 kg 120 860 kg 1212 450 kg 125 kg 75 kg Note: Single weights have to be added up for system configuration to get the total weight! 850mm 835mm Dimensions (WxDxH): 835mm x 850mm x 1900mm UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass 1 = Rectifier 3 = Electronic Bypass 5 = Mains 7 = External Battery 2 = Inverter 4 = Manual Bypass 6 = Load F4 = External Battery Fuses Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Protections and cable sections Cable sections recommended by European s Alternatively, local standards to be respected kva Fuses AgL or equivalent MTCB Cable sections (mm 2 ) F1 F2 F3 F4 A B C & D & E K 60 3x100A 3x100A 3x100A 2x160A 3 x 25 + 16 4 x 25 4 x 25 + 16 2 x 50 + 25 80 3x125A 3x125A 3x125A 2x250A 3 x 35 + 25 4 x 35 4 x 35 + 25 2 x 120 + 70 100 3x160A 3x160A 3x160A 2x315A 3 x 50 + 25 4 x 50 4 x 50 + 25 2 x 150 + 95 120 3x200A 3x200A 3x200A 2x355A 3 x 70 + 35 4 x 70 4 x 70 + 35 2 x 185 + 95 Cable sections recommended in Switzerland (mm 2 ) F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer kva A B C & D & E K K: supplied by GE only with battery 60 3 x 35 + 25 4 x 35 4 x 35 + 25 2 x 70 + 35 F4: can be supplied by GE. 80 3 x 50 + 25 4 x 50 4 x 50 + 25 2 x 150 + 95 100 3 x 70 + 35 4 x 70 4 x 70 + 35 2 x 185 + 95 120 3 x 95 + 50 4 x 95 4 x 95 + 50 2 x 240 + 120 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Modifications reserved Page 6/6