UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

Similar documents
UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

DC-UPS CONTROL UNIT SHORT-FORM DATA MARKINGS

UB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS DC-UPS CONTROL UNIT 24V, 10A, DC-UPS 1/21.

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Bulletin 1606 Switched Mode Power Supplies

DECOUPLING MODULE. Input to output voltage drop

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

UB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS DC-UPS CONTROL UNIT 1/23 PRELIMINARY. UB-Series Related products

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

DC-UPS CONTROL UNIT SHORT-FORM DATA

M Series External Battery Frame. User Guide

Industrial Power Supplies

c-go 24V/6A 24V/8A 24V/12A

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

MS General Information Extended Product Type: MS

Dependable innovative. partner. efficiency achieved. global flexible industry Leadership.

Installation and Operations Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

SHORT-FORM DATA MARKINGS

POWER SUPPLY CS5.241-S1 CS5.244

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

POWER SUPPLY CS S1 CS10.481

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

SG-B1 SERIES / SG-A1 SERIES

CS5.241, CS5.241-C1, CS5.241-S1

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

BOOST POWER 1212 Product Description

RX 3 M.C.B A up to 63 A

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Mini contactors B6, BC6 with 3 pole

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

SHORT-FORM DATA MARKINGS

RX 3 M.C.B A up to 63 A

Powerware Vdc Extended Battery Cabinet User s Guide.

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Phoenix Inverter

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Chapter. Installation and. In this Chapter...

1329I Integrated Drive/Motor CE Filter Option Kit

Technical Documentation

Electronic Circuit Breaker ESS20-0..

Electronic overload relay EF65, EF96 and EF146

SHORT-FORM DATA MARKINGS

Installing Power Components

Switching DC Power Supply

AF40... AF96 3-pole contactors Technical data

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

PURE SINE WAVE DC TO AC POWER INVERTER

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Galaxy VM. Battery Breaker Box Installation 09/

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

General_technical_data Series

Direct Coupled Damper Actuator Model MY6050A1001

CX Series User s Manual

POWER SUPPLY SHORT-FORM DATA MAJOR AGENCY APPROVALS

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Thermal overload relay TF65 and TF96

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.

SITESTAR ELECTRONICS CABINET DESCRIPTION

Operating Instructions

1100 Series Piston Type Differential Pressure Gauges

SCCP PWM Charge Controller/Load Manager Owner s Manual

HS6B Series Subminiature Interlock Switch

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

up to 63 A (1 module per pole)

B Mini Contactor V Hz

1606-XLE240EN 24V,10A Single Phase Input

Direct Coupled Damper Actuator Model MY9050A1001


Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

SBC / 2140 / Stage Battery Charger User Manual

Uninterruptible Power Supplies

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Manual motor starter MS116

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

Electronic overload relays EF205 and EF370

CPS Energy Balancer. Version: 1.0

CBI All in One DC UPS Power Solutions

CX-SERIES ADVANCED BATTERY CHARGER

RUZ- _/_ Protection (3) Isolation Option (4)

Application Mini Contactors for Motors and Resistive Loads

Transcription:

PASSIVE BATTERY MODULE 24V, 12Ah Battery Capacity (2x 12V Batteries in Series) IP00 Open Type Protection Level Small Mounting Footprint ATO Fuse for Power Wires Included 2m Power Leads Included PT1000 Sensor for Battery Module Temperature Included Center-tap Terminal with Auto-resettable Fuse Included to Support the PULS 1-Battery-Concept 1. GENERAL DESCRIPTION The UZK24.121 passive battery module utilizes two nonspillable maintenance-free lead-acid batteries (connected in series), that are assembled in one package with all the required wiring included. The battery module includes the monitoring and protection board UZS24.100. This board contains a temperature sensor and a center-tap connection with an auto-resettable fuse to protect the center-tap wire between the battery module and the DC-UPS control unit. Connecting the center-tap wire to the DC-UPS control unit enables all the benefits of the PULS 1- Battery-Concept. This makes the use of matched replacement batteries unnecessary and allows a precise battery charging and testing which results in the longest possible battery life. The UZK24 battery module is available in two different options. It can be ordered with assembled batteries or as a battery bracket without batteries, allowing for different battery options. The mounting bracket option also allows the batteries to be assembled just in time, avoiding outdated batteries due to limited shelf life. 2. DATA Battery type VRLA Lead-acid Battery design life 3 to 5 years acc. EUROBAT Battery voltage DC 24V Battery capacity 12Ah Battery current max. 35A for discharging max. 3.5A for charging Battery fuse 35A ATO fuse Temperature sensor PT1000 Charging voltage 27.8V 27.5V 27.15V 26.8V at 10 C at 20 C at 30 C at 40 C Self-discharge rate 3%/month at 20 C Temperature range -10 C to +40 C for charging -15 C to +50 C for discharging -20 C to +50 C for storage Dimensions 203x186x143mm WxHxD Weight 9000g / 19.8lb 900g / 2lb UZK24.121 UZO24.121 3. ORDER NUMBERS 4. MARKINGS Battery Module UZK24.121 UZO24.121 Battery module with assembled batteries Battery module without assembled batteries IND. CONT. EQ. UL 508, pending UL 60950-1, pending LVD Replacement UZB12.121 Battery replacement 12V, 12Ah 2pcs needed for one battery module 1/9

U-Series INDEX Page 1. General Description...1 2. Data...1 3. Order Numbers...1 4. Markings...1 5. Intended Use...2 6. Instructions for Disposal of the Battery...2 7. Warranty...2 8. Installation Instructions...3 9. Replacing Batteries...4 Page 10. Functional Diagram... 4 11. Environment... 4 12. UZS24.100 Sensor Board... 5 13. Protection Features... 6 14. Approvals... 6 15. Physical Dimensions and Weight... 7 16. Recommendations for a Long Battery Life... 8 17. Mounting Orientations... 9 The information presented in this document is believed to be accurate and reliable and may change without notice. No part of this document may be reproduced or utilized in any form without permission in writing from the publisher. 5. INTENDED USE This module is designed for installation in an enclosure and is intended for the general professional use such as in industrial control, office, communication, and instrumentation equipment. Do not use this module in equipment, where malfunction may cause severe personal injury or threaten human life. 6. INSTRUCTIONS FOR DISPOSAL OF THE BATTERY Always dispose the batteries through a recycling organization. Batteries must be completely discharged before recycling. 7. WARRANTY 3 Year limited warranty except batteries which are considered a service part. 2/9

8. INSTALLATION INSTRUCTIONS This device may only be installed and put into operation by qualified personnel. Check the last charging date of the batteries (marked on the battery). If it is older than 9 month replace the batteries. PULS charges every battery before shipment. For storage, installation and operation, the requirements of the EN 50272-2 as well as other national regulations must be observed. Place the battery module in a cool area inside a cabinet and ensure sufficient ventilation for the battery. The battery module should be securely mounted on a flat surface. If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to the factory for inspection. Shorten the (+) and (-) wires as needed for the DC-UPS between the battery module and the DC-UPS. If seperate wires are used, do not use wires smaller than 4mm 2 (12 AWG). When required, install the UZS24.100 sensor board. The sensor board can be snapped on the metal mounting bar as shown in chapter 12. Connect the blue center-tap wire to the battery. Connect the sensor board to the DC-UPS by using control wires with a minimum wire size of 0.5mm 2 / 20AWG. The last step is to insert the battery fuse and to store the spare fuse in the designated holes of the plastic cover. Do not store batteries or the battery module longer than 9 month without supplementary charge or performance might change. WARNING Risk of electrical shock, fire, personal injury or death. - Do not short-circuit the battery poles or power wires - Observe correct battery polarity - Disconnect battery fuse before working on the battery or on the DC-UPS. Protect against inadvertent re-powering. - Make sure that the wiring is correct by following all local and national codes. - Do not modify or repair the unit. - Do not use in wet locations or in areas where moisture or condensation can be expected. Fig. 8-1 Wiring scheme Fig. 8-2 Bracket hole pattern (+) (-) Load Input X1 Data/ Temp. (11) RTN (12) DC-UPS Center Tap (13) Output X2 Battery (+) (-) UZK24.121 Battery Module Battery wires (+) (-) X1 Temp. RTN (11) (12) Center Tap (13) optional 3/9

9. REPLACING BATTERIES Disconnect battery fuse before replacing the batteries. To replace battery, loosen screw with only one turn and slide the mounting bracket sideways. Replace only one battery at a time. Always dispose the batteries through a recycling organization. Batteries must be completely discharged before recycling. Batteries can also be returned to PULS or the battery manufacturer. Battery replacements can be acquired through PULS. PULS also offers a list with recommended batteries in case batteries need to be acquired elsewhere. 10. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram battery module with sensor board (+) 2m Fuse + 12V - BAT1 (-) 2m + 12V - BAT2 X1: Center Tap Auto Temp. RTN Temp. Sensor Resettable Fuse UZS24.100 Sensor board 11. ENVIRONMENT Operational temperature *) -10 C **) to +40 C (14 F to 104 F) for charging -15 C to +50 C (5 F to 122 F) for discharging Storage temperature -20 C to +50 C (-4 F to 122 F) for storage and transportation Humidity 5 to 95% r.h. IEC 60068-2-30 Do not energize while condensation is present Vibration sinusoidal Shock ±4mm at 16.7Hz fixed frequency for 1hour free fall from 20cm onto a wooden floor Vibration in vertical mounting orientation according to IEC/EN 61056-1 Shock with bottom down orientation according to IEC/EN 61056-1 Altitude 0 to 6000m (0 to 20 000ft) without any restrictions Degree of pollution 2 IEC 62103, EN 50178, not conductive LABS compatibility The unit does not release any silicone or other LABS-critical substances and is suitable for use in paint shops. *) Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit. **) Frequently charging below +5 C (41 F) reduced the lifetime of the battery 4/9

12. UZS24.100 SENSOR BOARD The battery module includes the monitoring and protection board UZS24.100. This board contains a temperature sensor and a centertap connection with an auto-resettable fuse to protect the center-tap wire between the battery module and the DC-UPS control unit. The UZS24.100 is compatible with most of the PULS DC-UPS control units and enables all the benefits of the PULS 1-Battery-Concept.This makes the use of matched replacement batteries unnecessary and allows a precise battery charging and testing which results in the longest possible battery life. The use of the sensor board is optional, the DC-UPS will also function without the sensor board installed. Screw terminal specification: Solid wire 0.5-1.5mm 2 Stranded wire 0.5-1.5mm 2 American Wire Gauge AWG20-12 Max. wire diameter 1.5mm (including ferrules) Wire stripping length 6mm / 0.25inch Screwdriver 3x 0.5mm slotted Recommended tightening torque 0.5Nm/ 4lb-in Follow national installation codes and installation regulations! Ensure that all strands of a stranded wire enter the terminal connection! Unused terminals should be securely tightened. Ferrules are allowed. 5/9

U-Series 13. PROTECTION FEATURES Degree of protection IP 00 EN/IEC 60529 Class of protection III EN/IEC 61140 Internal input fuse 35A DC-Fuse (ATO blade type) Isolation voltage between power and signal circuits to chassis 1100Vac 14. APPROVALS EC Declaration of Conformity IEC 60950-1 2 nd Edition, pending UL 508, pending UL 60950-1 2 nd Edition, pending IND. CONT. EQ. The CE mark indicates conformance with the low-voltage directive (LVD) 2006/95/EC. CB Scheme, Information Technology Equipment Listed for use as Industrial Control Equipment; U.S.A. (UL 508) and Canada (C22.2 No. 107-1-01); E-File: E198865 Recognized for use as Information Technology Equipment, Level 5; U.S.A. (UL 60950-1) and Canada (C22.2 No. 60950-1); E-File: E137006 6/9

U-Series 15. PHYSICAL DIMENSIONS AND WEIGHT Size (WxHxD) 203x186x143mm with installed sensor board UZS24.100 203x186x135mm without installed sensor board UZS24.100 Weight 9000g / 19.8lb UZK24.121 900g / 2lb UZO24.121 Fig. 15-1 Front view Fig. 15-2 Side view Fig. 15-3 Isometric view 7/9

16. RECOMMENDATIONS FOR A LONG BATTERY LIFE Temperature: The temperature has the most impact on the service life. The hotter the temperature, the earlier the wear-out phase of the battery begins. The wear-out results in a degradation of battery capacity. Place the battery module in a cool location, E.g. near the bottom of the control cabinet. Do not place the battery module near heat generating devices. Do not overcharge batteries! Fig. 16-1 Service life vs. ambient temperature, typ. Service Life in Years 10 9 8 7 Design Life of Battery A: 3-5 Years C B: 6-9 Years C: 10-12 Years 6 B 5 4 A 3 2 1 Ambient Temperature 20 C 25 C 30 C 35 C 40 C 45 C Number of discharge cycles and depth of discharge: Do not discharge batteries more than necessary. Set buffer time limiter to the required buffer time. The number, as well as the depth of discharging cycles is limited. A replacement of the battery might be necessary earlier. When choosing the battery capacity, always try to get the next higher capacity than required. The depth of discharge reduces the service life of the battery and limits the number of cycles. Fig. 16-2 Battery degradation vs. discharging cycles, typ. Cell Capacity 120% 100% 80% 60% 40% 20% A B C Depth of discharge A: 100% B: 50% C: 30% Number of Discharging Cycles 0 200 400 600 800 1000 1200 Store batteries fully charged Do not store discharged batteries. Keep batteries fully charged! Charge retention is important to get the longest battery life. Stored batteries which are not fully charged age faster then charged batteries. Batteries which are not in use should be recharged at least once a year. The higher the ambient temperature, the shorter the charging interval. At storage temperatures higher than 30 C, recharging should be done at least every nine months. 8/9

17. MOUNTING ORIENTATIONS The standard mounting orientation is the vertical installation onto a flat surface. Fig. 17-1 Standard mounting orientation The following mounting orientations are also allowed: Fig. 17-2 Allowed mounting orientation Do not use the battery module in an upside down position: Fig. 17-3 Forbidden mounting orientation 9/9