Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

Similar documents
Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Agilent G1554A On-Column Capillary Inlet with EPC

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Installation Guide Thermal Conductivity Detector Accessory 19232E

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Installing the Flame Ionization Detector EPC Flow Control Manifold

Nickel Catalyst Tube Accessory 19205A

Installing a Purged Packed (PP) Inlet

Installing a Cool On-Column Inlet

Installing an Auxiliary Pressure Control Module

Installing an Auxiliary Pressure Control Module

Installing a PTV Inlet

Installing a PTV Inlet

HP 6890Series Gas Chromatograph. Installation Guide. Flame Ionization Detector. Accessories HP G1561A HP G1562A HP G1591A HP G1598A

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Installing a Purged Packed Inlet

Valve Box and Valve Accessories G4315A, G4316A, G4317A

Installing the CO 2 Cryogenic Oven Cooling Kit

Agilent G3510A/G3511A Multimode Inlet

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Installing the 6850 Direct Valve Column Connector Kit

Agilent G2738A Upstream Capillary Interface

Agilent G2333B (Single) and G2334B (Dual) Flame Photometric Detectors

Installation Guide. Agilent 7683 Automatic Liquid Sampler

Model 4430 Photoionization Detector (PID) Operator s Manual

260 Solvent Vapor Exit Accessory

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

29 Installation Step 1. Unpacking the GC Cable diagrams Step 2. Placing the GC system on the benchtop Step 3. Turning the power on

Agilent 6890 Gas Chromatograph

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Replacing the Batteries in the Fortress LI 660

PET UNIT DOSE CABINET

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450

Model Fixed Rack-Mount Kit

INSTALLATION INSTRUCTIONS

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Agilent G3348B Flame Photometric Detector

N/S= Not Shown Bold = Part available for purchase. Italic = Part not available for purchase, listed and shown for reference only.

Siemens Drives & PLCs

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

5 Removal and replacement

Agilent 490 Micro GC Internal and External Mount Genie Filter Brackets

Overview. Chassis Packaging

INSTALLATION INSTRUCTIONS

Agilent G2647A (Single) and G2648A (Dual) Flame Photometric Detector Update Kits

Agilent G4367A Auxiliary Electronic Pressure Control (Aux EPC) Module

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

PowerFlex 700 Drive - Frame 8 Components Replacement

HP Modular Cooling System 200/100 Options Installation Guide

Owner smanual. Banks Ram-Air Intake System Chevrolet/GMC 8.1L Workhorse Class-A Motorhome. with Installation Instructions

3875 Cypress Drive Petaluma, CA Fax

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS. ITEM QTY DESCRIPTION Usage Chart Service Part Number. 1 1 Mirror Assembly w/ Compass 1

2013 IMPCO Technologies, Inc. Page 1 of 20 EPR Repair Kit Instructions (PPI-122, Rev-B)

VHM-P (Non-Locking) Variable Height Arm with VESA Mounting Plate for 75 x 75mm or 100 x 100mm applications

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Altivar 61/71 Adjustable Speed Drives Spare Parts Kits

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

Deans Switch Microfluidics

* * APPLICABLE MODELS: 2014 > Mazda 3

Section 7 - Troubleshooting Guide

Installation Instructions. PowerFlex 700 Drive - Frame 7 Components Replacement

INSTALLATION INSTRUCTIONS

* * APPLICABLE MODELS: 2014 > Mazda 6

* * APPLICABLE MODELS: 2017 > CX-5

INSTALLATION INSTRUCTIONS

Prodigy HDLV Generation II Pump Panel

401B/1KDB CoolRite/FreezeRite Installation Manual I003

MAZDASPEED3 Intercooler Instructions

* * APPLICABLE MODELS: 2016 > CX-3

Remove the 3-11mm nuts holding mirror on. Don t drop the nuts!

System 3 ZB1PS Device Chassis. Operator s Manual

INSTALLATION INSTRUCTIONS

5000TOC Sensor Service Manual

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Switching DC Power Supply

ST 3000 R300 Smart Meter & R300 Smart Meter with ZS Option Installation Instruction

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

2-row and All-row systems included.

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

INSTALLATION INSTRUCTIONS

INSTALLATION OF OPTIC 3 INJECTOR SYSTEM ONTO AN SHIMADZU GC-2010 GAS CHROMATOGRAPH.

Remove Air Cleaner Cover and. Filter

Installation Instructions

Operations and Service Manual. X30208 Load Bank

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

INSTALLATION INSTRUCTIONS

Model TC-20. Tube Cut-Off Machine. Operator s Manual REV H

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

Gentex by VOXX Corporation Installation Instructions

ROUSH Active IO Exhaust. Installation Instructions P/N: (R LITE) Fastback GT Convertible GT V8

INSTALLATION INSTRUCTIONS

Transcription:

Installation Guide Flame Ionization Detector on a 6890 GC Accessories G1561A, G1562A, G1591A, G1598A

Agilent Technologies 2001 All Rights Reserved. Reproduction, adaptation, or translation without permission is prohibited, except as allowed under the copyright laws. Part number G1531-90327 First Edition, AUG 2001 Replaces Part No. G1531-90300, Installation Guide, Flame Ionization Detector, Part No. G1531-90305, Update for Flame Ionization Detector Accessory Installation Guide, and Part No. G1531-90320, Installing the Detector EPC Flow Control Manifold. Printed in USA Safety Information The Agilent Technologies 6890 Gas Chromatograph meets the following IEC (International Electrotechnical Commission) classifications: Safety Class 1, Transient Overvoltage Category II, and Pollution Degree 2. This unit has been designed and tested in accordance with recognized safety standards and designed for use indoors. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. Whenever the safety protection of the Agilent 6890 has been compromised, disconnect the unit from all power sources and secure the unit against unintended operation. Refer servicing to qualified service personnel. Substituting parts or performing any unauthorized modification to the instrument may result in a safety hazard. Disconnect the AC power cord before removing covers. The customer should not attempt to replace the battery or fuses in this instrument. The battery contained in this instrument is recyclable. Safety Symbols Warnings in the manual or on the instrument must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions violates safety standards of design and the intended use of the instrument. Agilent Technologies assumes no liability for the customer s failure to comply with these requirements. WARNING A warning calls attention to a condition or possible situation that could cause injury to the user. CAUTION A caution calls attention to a condition or possible situation that could damage or destroy the product or the user s work. Indicates a hot surface Indicates earth (ground) terminal Sound Emission Certification for Federal Republic of Germany Sound pressure Lp < 68 db(a) During normal operation At the operator position According to ISO 7779 (Type Test) Schallemission Schalldruckpegel LP < 68 db(a) Am Arbeitsplatz Normaler Betrieb Nach DIN 45635 T. 19 (Typprüfung) Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808-1610 USA

Overview Overview This section reviews the procedure for installing a flame ionization detector (FID) on an Agilent 6890 Gas Chromatograph (hereafter referred to as the GC). Before following this procedure, refer to the safety information on the inside front cover. Parts list EPC FID assembly: capillary optimized or adaptable Top insulation Bottom insulation Nutwarmer cup and insulation (for adaptable FID only) NonEPC FID assembly: capillary optimized or adaptable Top insulation Bottom insulation Makeup gas regulator Two machine screws Nutwarmer cup and insulation (for adaptable FID only) Tools Electrostatic protection such as grounded wrist strap (part no 9300-0969 for large wrists or part no. 9300-0970 for small wrists) T-20 Torx screwdriver Diagonal cutters 7/16-inch wrench (nonepc detectors only) 1

Overview Steps 1. Preparing the GC 2. Installing the flow manifold 3. Installing the makeup gas regulator (nonepc detectors only) 4. Positioning and securing the detector 5. Connecting the detector 6. Routing the tubing 7. Installing the nutwarmer cup (adaptable FID only) 8. FID chimney insert (optional) 9. Restoring the GC to operating condition 10. Calibrating your detector (EPC detector only) 2

Overview Flame ionizaton detector Makeup gas regulator (nonepc only) Flow manifold (early version) Power switch Printed circuit board 3

Preparing the GC Preparing the GC WARNING Hazardous voltages are present in the mainframe when the GC is plugged in. Avoid a potentially dangerous shock hazard by unplugging the power cord before removing the side panels. 1. Turn off the GC and unplug the power cord. Allow time for all heated zones to cool and then turn off supply gases at their sources. From the back of the GC (see figure on next page): 2. Unsnap and lift off the pneumatics top cover. 3. Remove the RFI cover. Remove the screw with a T-20 Torx screwdriver, slide the cover to the left until it disengages from the top rear panel, and remove it. 4. If you are installing a nonepc detector, remove the detector cover plate from the front or back position by loosening the two screws with a T-20 Torx screwdriver and sliding the plate up and off. 5. Loosen the five screws in the top rear panel with a T-20 Torx screwdriver. Grasp the panel at each end and gently lift it up and then away from the GC. Be careful not to disrupt the supply tubing. 4

Preparing the GC Pneumatics top cover RFI cover Makeup gas regulator (nonepc detectors only) Loosen five screws 6. Raise the gray plastic top cover (with the holes and ventilation slots) to the vertical position. Examine the hinge in the right rear corner. Early 6890 models. The hinge is a metal bracket attached to the oven top. Pull the clip at its top toward you to release the hinge pin. Push the pin to the left to release the cover. Tilt the cover to the left and remove it. Current 6890 models. Tilt the cover to the left and remove it. 5

Preparing the GC Caution Board components can be damaged by static electricity; use a properly grounded static control wrist strap when removing the electronics covers. 7. Remove the electronics side cover. Loosen the two captive screws at the top, slide the panel to the rear, and lift it off. Captive screws 8. Remove the electronics top cover. Press the tab under the back end of the cover and lift it off. Tab underneath cover 6

Installing the flow manifold Installing the flow manifold This section describes installation of the current version of the pneumatics module. For information on the earlier version, see the Appendix. Caution It is not necessary and not advisable to separate detectors from their pneumatics modules. Doing so can cause leaks. Although handling the detector and pneumatics module as a unit is awkward, it can be managed. 1. Locate the correct slot for the pneumatics module. Detector in the front position. Use the second slot from the left (as viewed from the back of the GC). Detector in the back position. Use the third slot from the left (as viewed from the back of the GC). Caution Hold the manifold by its support bracket to avoid damaging the components. 2. Route the ribbon cable behind the manifold assembly as shown in Figure 1. Then, slide the manifold and bracket assembly into the slot until the bracket seats flush against the end of the rails. See Figure 2. Back view of manifold Manifold installed with cable routed to left Figure 1. Routing the ribbon cable 7

Installing the flow manifold Route tubing along this path Bracket is flush with carrier rails Check for interference Figure 2. Manifold, after installation 3. Secure the manifold in place using a Torx T-20 screw from the front of the pneumatics chassis. See Figure 3. 4. Route the gas tubing over the top of the chassis and through the slots as shown in Figure 3. Front captive screw Front detector tubing Slot for back detector tubing Back captive screw Figure 3. Captive screws and tubing 5. Connect the ribbon cable to the mating connector on the pneumatics board. Arrange the cable to keep it away from the valves and keep it from being pinched against the manifold. 8

Installing the flow manifold For the back detector, you may want to loosen the manifold and slide it out of the carrier a few centimeters to connect the cable to the pneumatics board. Then, reinstall the manifold. Caution If your top rear panel is different from the one in Figure 4, discard it and use the one from the accessory kit. 6. Using a pair of needle-nosed pliers, remove the appropriate top rear panel detector cutout for the FID. Also remove any cutouts needed to access other manifolds or accessories installed in the GC. See Figure 4. Insert tip of pliers here Back inlet Front detector Front inlet Auxiliary Back detector Figure 4. Top rear panel cutouts 7. Install the RFI shield, the pneumatics cover, and the detector top cover. 8. Connect the source gas lines to the manifold. See Figure 5. Figure 5. Gas line connections 9

Installing the makeup gas regulator (nonepc detectors) Installing the makeup gas regulator (nonepc detectors) 1. Install a screw in the front or back position of the pneumatics carrier. Do not tighten the screw. Install a screw in the makeup gas regulator. Do not tighten the screw. Back Front Screw 2. Place the makeup gas regulator in the front or back position of the pneumatics carrier. Tighten the screws with a T-20 Torx screwdriver. 3. Connect the tube on the makeup gas regulator to the fitting labeled MU on the flow manifold. Tighten the nut fingertight, then use the 7/16-inch wrench to tighten it 3/4 of a turn. Follow the same procedure for 10

Installing the makeup gas regulator (nonepc detectors) connecting the air and hydrogen tubing (labeled at the back of the GC) to the flow manifold. Air Hydrogen Makeup gas regulator 4. Locate the RFI cover that you removed in Preparing the GC. Remove the rectangular cutout in the front or back detector position. Use diagonal cutters to cut the metal in the two locations or work the cutout back and forth until it breaks free from the cover. Cut here RFI cover from back of GC Back Front 5. Locate the pneumatics cover that you removed in Preparing the GC. Remove the oval labels in the front or back detector position by pushing on the label from underneath the cover. Pneumatics cover from back of GC Back Front 11

Positioning and securing the detector Positioning and securing the detector 1. Remove the round metal cutout on the oven top and the square plastic cutout in the electronics carrier in the front or back detector position, if necessary. Cut the metal circle with diagonal cutters so that the nibs are connected to the piece removed. Cut the plastic in six places with diagonal cutters. Discard the cutouts. Back Front 2. Lift out the die-cut insulation plug from the front or back detector position, if necessary. Caution Be careful to remove only the insulation within the scribed circle. 3. Carefully remove the scribed circle of insulation from the oven top to create an opening into the oven. 12

Positioning and securing the detector Method 1: Use a sharp knife to cut out the insulation using the scribed circle as a guide. Method 2: Pierce the insulation with a screwdriver. Rotate the screwdriver around the edge of the scribed circle to remove excess insulation. Clean up any pieces of insulation that fall inside the oven. 4. Place the bottom insulation in the detector cavity. 5. Place the top insulation in the bottom insulation so that the hole in the insulation lines up with the hole in the oven top.. 6. Place the detector pallet into the insulated cavity. Partially tighten the four screws with a T-20 Torx screwdriver. Tighten all the screws to snugness. Captive screws (4) Top insulation Pallet Bottom insulation 13

Connecting the detector Connecting the detector Caution Board components can be damaged by static electricity; use a properly grounded static control wrist strap when handling the FID board. 1. Remove the PC board from its static control bag and slide into the front or back slot on the main circuit board until it is plugged in. Tighten the screw on the PC board bracket with a T-20 Torx screwdriver. Plugs into main board Front detector slot Tighten screw Back detector slot 14

Connecting the detector 2. Attach the signal cable and ignition wire to the PC board, if not already connected. Ignition cable Signal cable Signal connector PC board Ignition connector 15

Connecting the detector 3. Connect the heater/sensor wire to the square connector closest to the front or back detector. Heater/sensor wire Heater/sensor connector (back position) Heater/sensor connector (front position) 16

Routing the tubing Routing the tubing Route the tubing from the flow manifold over the top of the pneumatics chassis, through the appropriate slot, to the detector area. Front detector tubing Back detector tubing Installing the nutwarmer cup (adaptable FID) 1. Install the insulation in the cup. 17

Installing the nutwarmer cup (adaptable FID) 2. Push the wire spring lever at the bottom of the cup to the right to uncover the hole. 3. From inside the oven, place the cup over the detector fitting so that the top of the cup touches the top of the oven. 4. Release the spring. Make certain the spring fits in the groove of the detector fitting. 18

FID chimney insert (optional) FID chimney insert (optional) Install a PTFE chimney insert (part no. 19231-21050) if you are running highly corrosive analytes. These inserts may be ordered from the Agilent analytical supplies catalog. Chimney insert 19

Restoring the GC to operating condition Restoring the GC to operating condition 1. Reinstall the electronics side panel. 2. Reinstall the top rear panel 3. Reinstall the detector cover. 4. Reinstall the electronics top cover. 5. Plug in the GC and turn it on. 6. Press [Front Det] or [Back Det]. If the detector has been properly installed, you will see the following display: EPC NonEPC FRONT DET (FID) Temp 24 Off < H2 flow 0.x Off Air flow 0.x Off Mkup flow 0.x Off Flame Off Output 0.0 FRONT DET (FID) Temp 24 Off < H2 flow Off Air flow Off Mkup flow Off Flame Off Output 0.0 An actual flow value is displayed when the gases are off or not connected. This is not an error. After the gases are connected and the detector is operational, the actual flow values will be equal to the setpoint values. 20

Calibrating your detector (EPC only) Calibrating your detector (EPC only) Your detector s flow manifold contains a pressure sensor that must be zeroed after it is installed on your GC. This calibration procedure ensures an accurate detector display. Caution Do not connect the detector and makeup gases to your flow manifold until you have zeroed your detector s pressure sensor. 1. Plug in your GC and turn it on, if you haven t already done so. 2. Wait 15 minutes. This allows your GC to reach thermal equilibrium. 3. Zero the detector s pressure sensor: a. Press [Options], scroll to Calibration and press [Enter]. b. Scroll to Front detector or Back detector and press [Enter]. c. Scroll to Oxidizer zero and press [On]. d. Scroll to H2 zero and press [On]. e. Scroll to Makeup zero and press [On]. 4. Turn off your GC and unplug the power cord. 5. Plumb the air, hydrogen, and makeup gases to your detector. See the Agilent 6890 Site Preparation and Installation Manual for instructions. 6. Reinstall the RFI cover. 7. Replace the pneumatics top cover. 8. Plug in the GC again and turn it on. 21

Appendix: Installing the pneumatics module (early version) Appendix: Installing the pneumatics module (early version) Caution Board components can be damaged by static electricity; use a properly grounded static control wrist strap when removing the electronics covers. 1. From the back of the GC, locate the pneumatics carrier. Pneumatics carrier 2. If you are installing a detector in the front position and an inlet is installed in the back position, unplug the back inlet ribbon cable. Unlock the connector by pushing the tabs away from the center. Connector locations Back detector Front detector Back inlet Front inlet 22

Appendix: Installing the pneumatics module (early version) 3. Locate the troughs in the flow manifold and the ridges in the pneumatics carrier. Slide the flow manifold into the carrier, lining up the ridges and troughs. Back detector Ridges Front detector Troughs Flow manifold 4. Plug the ribbon cable into the front or back connector. Make certain the connector is firmly seated and locked. If the flow manifold is installed and plugged into the correct position, the ribbon cable will retain its fold as shown in the diagram. If you unplugged an inlet ribbon cable in Step 2, replace it. Folded ribbon cable Open connector Locked connector 23

Appendix: Installing the pneumatics module (early version) 5. From the front of the GC, secure the flow manifold to the carrier by tightening the captive screw until snug using a T-20 Torx screwdriver. Front captive screw Back captive screw 24

Printed on recycled paper. This product is recyclable. Agilent Technologies, Inc. Printed in USA AUG 2001 G1531-90327