Manual and Remote Start Unit with Key Switch, x DI Size FAILED TO ~~~ ~ ~ STOP 0 I Hz./ EAOM - 36 SPEED FAILURE CHARGIG FAIL Features Designed For Generator, Pump & Fire Pump Applications Remote start / stop capability with zero power consumption Engine start and stop Automatic shutdown on fault condition Provides alarm and status information Alarm and shutdown inputs Provides charge alternator excitation current Lamp test function Fail Monitoring Oil pressure Engine temperature Over speed & Under speed (generator application) Charging alternator Conf. Input- & Controls Engine fuel or stop solenoid Starter motor Preheat, external alarm horn or alarm out EAOM-36 Manual Start Unit use microprocessor based technology to provide integrated manual start and fault protection in a wide range of engine applications. The module is housed in x DI size.the module is used to start and stop the engine, indicating the operational status and fault conditions. Automatically shutting down the engine and indicating the engine failure by a flashing LED. User can control the engine via a two position key switch and pushbuttons mounted on the front panel or with remote input. The module has three application feature; 'Generator', 'Pump' or 'Fire Pump'. (can be selected from parameter P00). The module can connect directly with engine, thanks to high current relay outputs. The module has two feature for fuel. One of energize to run the other energize to stop. User can select the feature from program parameters. The module protect the engine against fault conditions. If a fault condition occurred, the module indicate the fault condition and shut-down the engine. If the key switch is OFF position the module has zero power consumption to save energy. The module energizes when the key switch position is getting O position. If Satart button is pressed, the Conf. Out relay output (if selected preheat output) will activate until the preheat delay is expired. Press Start button for starting the engine. When engine is running, module will stop the cranking. Also the module has remote start facility. Please select suitable type of remote start for your application from program parameters. If remote start input is active the module will start the engine. If remote start is passive the unit will stop the engine. The module will check the alarms aftersafety on timer is expired. Under one of this fault conditions the module will stop the engine; - Over speed (generator application), - Under speed(generator application), - High Temperature, - Low Oil Pressure, - Shutdown (if one of conf. input selected shutdown and activated). To reset the fault, turn the key switch to the OFF position for a few seconds. The Charge Failure is a warning alarm so the engine continue to work under this failure condition. Also this input supplying charge alternator excitation current. Shutdown the engine; If the engine fuel type is energize to stop, press Stop button until the engine comes to rest. After that select OFF position of the key switch. If the engine fuel type is energize to run, select OFF position of the key switch. Important note: On the Fire Pump application; If a fault condition occurred, the module will not stop the engine. The engine will be stopped only when the stop button was pressed or the remote stop signal was detected. Introduction Brochure. EG EAOM-36R 0 V00 05/09
Manual and Remote Start Unit with Key Switch, x DI Size Program Parameters for Generator Application Prog o Parameter ame Unit Limits Default P 00 Application Selection (Generator, Pump, Fire Pump) - GEn, PUP, FPU GEn P 0 P 0 P 03 Frequency Lower Limit Frequency Upper Limit ominal Alternator Frequency Hz. Hz. Hz. 30.0-5.0 30.0-5.0 30.0-5.0 4.0 53.0 50.0 P 04 ominal Speed Rpm 500-5000 500 P 05 Stop/Fuel Solenoid Selection - StoP - FUEL FUEL P 06 Stop Solenoid Energising Time Sec. - 99 0 P 0 Crank Disconnect on Gen. Frequency Hz. 5.0-5.0 30.0 P 08 Crank Disconnect on Charge Alternator Voltage - dis - EnAb dis P 09 Crank Disconnect on Oil Pressure - dis - EnAb EnAb P 0 umber of Starting Attempts umber - 0 3 P Starting Attempt Duration Sec. 5-99 5 P Oil Pressure Bypass Time Sec. 0-99 30 P Safety On Delay Sec. 0-99 0 P 4 Frequency Fault Control Delay Sec. 0.0-0.0 3.0 P 5 Engine Running Time Value & ew Engine Running Time Hour 0-9999 0 P 6 Remote Start Selection: - 0= dis - dis 0 - Disable. The start / stop buton is used. (leave key switch position) - When the TERY applied to Rem. start input (terminal-), the engine start cranking. (leave key switch position) - When the TERY applied to input (terminal-3), the engine start cranking. (leave key switch position) P Conf. Out Type: 0 - Alarm Out - Horn Out - 0 - - Preheat Out P 8 Conf. Input - Only horn permanent, observation continuously - Engine stop, observation continuously - 0-5 0 P 9 Conf. Input P 0 - Only horn permanent, observation continuously - Engine stop, observation continuously Horn Duration - Sec. 0-5 0= Cont. - 999 0 30 P Password - 0-9999 0 Program Parameters for Pump (Fire Pump) Applications Prog o Parameter ame Unit Limits Default P 00 Application Selection (Generator, Pump, Fire Pump) - GEn, PUP, FPU PUP P 05 Stop/Fuel Solenoid Selection - StoP - FUEL FUEL P 06 Stop Solenoid Energising Time Sec. - 99 0 P 08 Crank Disconnect on Charge Alternator Voltage - dis - EnAb dis P 09 Crank Disconnect on Oil Pressure - dis - EnAb EnAb P 0 umber of Starting Attempts umber - 0 3 P Starting Attempt Duration Sec. 5-99 5 P Oil Pressure Bypass Time Sec. 0-99 30 P Safety On Delay Sec. 0-99 0 P 5 Engine Running Time Value & ew Engine Running Time Hour 0-9999 0 P 6 Remote Start Selection: - 0= dis - dis 0 - Disable. The start / stop buton is used. (leave key switch position) - When the TERY applied to Rem. start input (terminal-), the engine start cranking. (leave key switch position) - When the TERY applied to input (terminal-3), the engine start cranking. (leave key switch position) P Conf. Out Type 0 - Alarm Out - Horn Out - 0 - - Preheat Out P 8 Conf. Input - Only horn permanent, observation continuously - Engine stop, observation continuously - 0-5 0 P 9 Conf. Input - Only horn permanent, observation continuously - Engine stop, observation continuously - 0-5 0 P 0 Horn Duration Sec. 0= Cont. - 999 30 P Password - 0-9999 0
Manual and Remote Start Unit with Key Switch, x DI Size Specifications Equipment Use Housing & Mounting Panel Cut-out Protection Weight Environmental Rating Operating / Storage Temperature Operating / Storage Humidity Installation Over Voltage Cat. Pollution Degree Mode of Operation EMC Electrical Safety Supply Voltage() Generator Speed Measurement Alternator Frequency Range Frequency Meas. Accuracy Cranking Dropouts Relay Outputs Failure Indicators Status Indicators Electrical control equipment for generating sets mm x mm x 5 mm 68 mm x 68 mm EMA4X (IP30 at front panel, IP0 at rear side) Approximately 0.5 kg Standard, indoor at an altitude of less then 000 meters with non-condensing humidity -5ºC to 0ºC / -40ºC to 85ºC 90% max. (on-condensing) II appliances, portable equipment II, ormal office or workplace, non-conductive pollution Continuous E-6000-6-4, EMC generic emission standard for industrial equipment E-6000-6-, EMC generic immunity standard for industrial equipment E-600-, safety requirements for electrical equipment for measurement, control and laboratory use 8-3 V From generator voltage 5,6 to 99,9 Hz (5 to 300 VL-RMS) 0.5% Battery voltage can be 0V for max. 00msn during cranking (battery voltage should be at least nominal voltage before cranking) Start relay (0A@8V) Fuel relay (0A@8V) Conf. Out relay (0A@8V) Failed to engine start High engine temperature Low oil pressure Speed failure Battery charge failure General failure Hz./ Engine running time Engine start Engine stop 3
Manual and Remote Start Unit with Key Switch, x DI Size Dimensions & Front View EAOM - 36 Hz./ FAILED TO SPEED FAILURE ~~~ ~ ~ CHARGIG FAIL mm STOP 0 I Panel Cut-Out mm 5 mm 4 mm 68 mm TEA 68 mm EAOM-36.R Terminal Connections EAOM-36.RF Terminal Connections (Fail Safe) HIGH TEMP. LOW OIL PRES. () GE. D(W.L.) FUEL COF.O 5 6 3 4 8 9 0 COF. IPUT- COF. IPUT- OR REMOTE (P6= => REM. IPUT) RS 3 GD TX RX GEERATOR VOLTAGE 300VAC (Ph-) Max. HIGH TEMP. LOW OIL PRES. () GE. D(W.L.) FUEL COF.O 5 6 3 4 8 9 0 COF. IPUT- COF. IPUT- OR REMOTE (P6= => REM. IPUT) RS 3 GD TX RX GEERATOR VOLTAGE 300VAC (Ph-) Max. 4
GEERATOR GEERATOR Manual and Remote Start Unit with Key Switch, x DI Size Connection Schematic (Without Remote Start P6 = 0 (dis)) ALTERATOR 5 6 4 0 COF.OUT FUSE- ER SOLEOID EGATIVE MUST BE GROUDED GE. D(W.L.) COF. IPUT- COF. IPUT- HOR FUSE- According to current required by solenoids (Max. 6A. T) Max. A. T - Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and - Use Alternator connection only generator application (P00 = Gen) Connection Schematic (With Remote Signal P6 = ) ALTERATOR 5 6 4 0 COF.OUT FUSE- ER SOLEOID EGATIVE MUST BE GROUDED GE. D(W.L.) COF. IPUT- REMOTE SIGAL HOR FUSE- According to current required by solenoids (Max. 6A. T) Max. A. T - Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and - Use Alternator connection only generator application (P00 = Gen) 5
G EERATO R GEERATOR Manual and Remote Start Unit with Key Switch, x DI Size Connection Schematic (With Remote Start, o Power Consumption P6 = ) ALTERATOR 5 6 4 0 REMOTE SWITCH FUSE- ER SOLEOID EGATIVE MUST BE GROUDED GE. D(W.L.) COF. IPUT- COF. IPUT- HOR COF.OUT FUSE- According to current required by solenoids (Max. 6A. T) Max. A. T - Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and - Use Alternator connection only generator application (P00 = Gen) Connection Schematic (For Fail Safe) ALTERATOR 5 6 4 0 COF.OUT FUSE- ER SOLEOID EGATIVE MUST BE GROUDED GE. D(W.L.) COF. IPUT- COF. IPUT- HOR FUSE- According to current required by solenoids (Max. 6A. T) Max. A. T - Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and - Use Alternator connection only generator application (P00 = Gen) Product Codes EAOM-36.R Manual and Remote Start Unit with Key Switch, x DI Size, with relay outputs EAOM-36.RF Manual and Remote Start Unit with Key Switch, x DI Size, with relay outputs & fail safe inputs Emko Elektronik San. ve Tic. A.S. DOSAB Karanfil Sok. o:6 TR 6369 Bursa/TURKIYE Phone: 90 4 6900 Fax: 90 4 69 www.emkoelektronik.com.tr emko@emkoelektronik.com.tr 6