EQUALIS S. Flow computer for depots. Metering Solutions Metering Solutions. Very open communication skills. Field of application.

Similar documents
Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

Countum Group. Metering Solutions. Aviation. Metering Solutions.

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

HTM Series Helical Turbine Meters

A unique density, viscosity sensor. High technology brick. Field oriented. For light & medium petroleum products. Related norms

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

H. HERMANN EHLERS GMBH

EC type-examination certificate UK/0126/0072 Revision 2

Flow meter Type Recordall (RCDL)

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

DFX Series Liquid Ultrasonic Flow Meters

PRECISION METERS & ACCESSORIES

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

LIQUID MEASUREMENT STATION DESIGN Class No

mass flowmeter for compressed air

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Metal tube variable area flowmeter for gases, liquids and steam

Superstatic 440. Static Heat- and Cooling Meter. Application

Electronic Limit Switch Type

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

MX-SERIES OVAL GEAR FLOW METERS

KDM ARMORED FLOW METER & SWITCH

Industrial OG meter series IOG Inline and flanged oval gear meter

Jet Fuel Conductivity Analysers & Additive Management systems

Series 3730 Electropneumatic Positioner Type

Flash Point Process Analyzer

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

VersaFlow Vortex 100 Vortex Flow Meter Specifications

SBMD 75 - BMD 200 BMD BMD 600

Fusion4 MicroBlender (ATEX/IECEx) The intelligent blend controller for all single stream blending applications.

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

PRECISION METERS. Tel: / Int'l: Fax: / Int'l: Springer Pumps, LLC Telford, PA 18969

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

High Performance Turbine Technology

TORRIX Magnetostrictive level sensor

Turbine flowmeters Series TM

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

OM004, OM006 & OM008 Oval Gear Meter

BARTON 7400 Precision Gas Turbine Flow Meters

OPTIGAS 4010C Technical Datasheet

better analysis counts

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

Micro Motion 7827 Digital Viscosity Meter

QUALITY INDUSTRIAL FLOWMETERS

MagFlux Q 8200 Series

GREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

VLM20 In-line Vortex Flowmeter

Pressure Transmitter

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

mass flowmeter for compressed air

Principle of Operation

INTERNATIONAL METAL ENGINEERING

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

F-1500 SERIES INSERTION TURBINE FLOW METER

Technical Data. Series Oval Flowmeter. Model 9400

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES

Flow VA 550 / 570. DVGW tested. Flow.

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

ViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE

Belt Scales Table of Contents

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

ELECTRO-HYDRAULIC ACTUATION SYSTEMS

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Technical Data. BiRotor Plus Positive Displacement Meter

DFX series. High-end Ultrasonic Flow Meters for Liquid Hydrocarbons Custody Transfer. 32 beams for ultimate performance

Lease Automatic Custody Transfer

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

VariStroke II Electro hydraulic Actuator

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

F-2700 SERIES INSERTION VORTEX FLOW METER

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

F-2700 SERIES INSERTION VORTEX FLOW METER

EI HMC Report Spring API Committee on Petroleum Measurement Standards Meeting

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

FLOWMETER (SMALL CAPACITY) METER SIZE 80, 81

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

QUALITY INDUSTRIAL FLOWMETERS

Genesis Series 2" and 3" Steel Meters

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

Armstrong In-Line and Insertion Vortex Flow Meters

Flap-Type Flow Meter Prall

Type Electronic Limit Switch

NC State University Design and Construction Guidelines Division 23 Energy Management

UTM10 Series Ultrasonic Transit-time Flowmeters

Macnaught Fuel & Oil Flow Meters

Transcription:

Countum Group Countum Group computer for depots EQUALIS S Equalis S is a field batch controller designed for oil depots and terminals. It meets all the requirements for tanker trucks, railcar and ships loading and unloading operations. Custody transfer certified, Equalis S is compatible with the entire range of volumetric and mass meters used in the oil industry. Equalis S is an all-in-one electronic register. It can interface directly with most terminal automation and data management systems. computers meters Measuring systems Accessories Field of application Tanker truck and rail car loading and offloading Bio-fuels online and batch blending Additive injection control Delivery of heating oil to individuals Delivery of fuels to service stations Delivery of fuels to worksites, ships, boiler rooms Key points Compact design for easy installation Because of its single box concept, Equalis S field batch controller has a drastically reduced installation cost. Its compact design allows easy installation on tank trucks and compact assemblies. User-friendly operations Equalis S Man Machine Interface offers a direct and local access to pre-programmed functions such as meter preset, ticket printing, product selection... Very open communication skills Friendly remote control of loading operations Associated with the Equaview PC based database management software, Equalis S allows a comprehensive overview and access to the key loading parameters such as loaded value, blending rate, pump operation, additive content, stop of the current delivery, driver and user identification, bill of lading printing An optimized verification tool All the diagnosis elements of the Equalis S flow computer and the operating conditions data are continuously stored by the Equaview software during the delivery in Crystal Report format. They can easily be extracted and send to Satam engineers for diagnosis or periodic verification of the flow computer. A comprehensive visualization of loading areas Equalis S continuously send to Equaview the loading area data. The gantry box represents graphically the position and status of each loading arm. The arm box gives all requested information about the transaction such as arm name, volume, temperature, flowrate, ticket number Multifunction and powerful associated software package Equalis S can be linked to the supervisory PC using Equaview software package. This plug and play multifunction tool allows data collection, remote control of loading operations, maintenance and configuration of Equalis S flow computer.

Technical Data - computer Model Aplication Functions EQUALIS S Electronic register, batch controller to be field mounted Control of dosing valves and blending valves Additive injection control (can control up to 12 additives per metering line) Management of safety devices (grounding, overfilling ) Calculation of base volume, mass and price Secured back-up of metrological data transactions Control of functions associated with the fuel distribution on truck (motor, pump clutch, valve, drain valve, bottom valve, overfill probe) Metrology Meter Inputs PD Meter, mass flow meter, ultrasonic meter, turbine meter Temperature Inputs Density input Pressure input Base volume/mass calculation Pt 100 or 4-20 ma transmitter RS485 Modbus or 4-20 ma transmitter 4-20 ma transmitter Fuels: ASTM 54B table - Ethanol, methyl ester, bio-diesel : ASTM 54C table Lubrication oils: ASTM 54D table - LPG: ASTM API as per NF M80 17 Equipment User Interface Display : Graphic screen, 240 x 128 pixels, backlight Volume resolution : 999999 points Numeric keyboard, pre-programmed pushbuttons, cycle start/stop pushbutton Inputs/Outputs Enclosure Data storage Aluminum base with epoxy coating 60 000 transactions Associated software package Equaview for : Data collection from Equalis batch controller, database management Remote control and display of loading operations Maintenance and configuration tool Printing of ticket, delivery slip, bill of lading 1 or 2 inputs dual-pulse with flow direction Meter inputs Intrinsic safety or NAMUR* Pt100 inputs Current inputs Digital inputs 1 or 2* inputs (4-wire Pt100) 1 or 2* for pressure, temperature and density measurements 15 inputs (intrinsic safety) and 2* input (NAMUR) for grounding system, arm position, overfilling system, additive volume, vapour recovery, emergency stop Digital outputs 10 (+10*) relays (250V, 10A) for valve commands, pump, alarm, additive injection control Pulse outputs Current input 1 volume output for seal parcel delivery & additive injection control 1 for flow rate, density, temperature, control valve (in preparation) Databus 1 port RS485 or Ethernet TCP/IP : communication with supervisory system and measurements inputs 1 port RS485 or RS232 : printer Communication protocole : Modbus RTU 1 port USB : Data extraction Operating conditions Ambient temperature Standard : -20 C to +55 C - Option : -40 C to +55 C Certification for potentially explosive atmospheres Protection class Power supply Custody transfer approval Dimensions ATEX et IEC Ex Zone 1 II 2 (1) 1 G Ex d [ia Ga] ia IIB T4 Gb Ga IP66 100 to 240 VAC 50 à 60 Hz - 19 to 36 VDC (only for truck version) Evaluation certificate EC/MID évaluation n LNE-25874 Type compliance certificate OIML R117-1 n LNE-24351 Height x width x depth (mm) : 278 x 350 x 192 (without cable glands) Weight : 16 kg Headquarters and Sales Department PARIS NORD II Bat. le Gauguin - 47, allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex France Phone: +33 (0)1 48 63 02 11 E-mail: sales@satam.eu Web: www.satam.eu Your local contact IFC Inflow Unit 3, Ryder Way, Basildon, Essex, SS13 1QH, United Kindom Phone: +44 (0) 1268 596 900 E-mail: sales@ifcinflow.com www.ifcinflow.com As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. B071-IFC-GB-REV2-0917-Marketing Satam Création & Impression : TACTIC IMPRESSIONS - 01 39 86 19 08

Countum Group Countum Group computer for on board metering Equalis S for trucks The Satam Equalis S is a powerful and versatile field batch controller designed for aircraft refueling vehicles and tank trucks. It meets all the requirements in terms of security and accuracy for installation fuels transport vehicles. Custody transfer certified, Equalis S is compatible with the entire range of volumetric meters used in this industrial sector. It can directly interface with most cab mounted data capture systems. computers meters Measuring systems Accessories Field of applications Delivery of oil and fuel via tank truck Delivery of aviation fuels to aircrafts via fuel transport vehicles Very open communication skills Communications features Communication via serial link, Ethernet and USB port Analog and binary inputs and outputs Configurable printing of parameters and transactions Data transfer to Host system Large number of supported protocols Can be directly linked to cab mounted data capture systems Compatible with most of existing measuring devices An optimized verification tool Diagnosis elements and the operating data continuously stored by the management software during the delivery. Possibility to extract data via USB port or serial link Remote access for periodic verification and diagnosis User-friendly operations Man-Machine Interface with direct and local access to pre-programmed functions such as meter calibration, meter selection, ticket printing, emergency stop... On screen browsing of stored transactions Duplication of volume or mass display Key points Metrology Weight and Measures Custody transfer approved Approved measurements of volume, temperature and density Calculation of base volume, mass, rate of flow Transactions in operating volume, base volume or mass Multipoint calibration for an optimized measurement accuracy Possibility to connect of one or two meters to the Equalis Transactions and data storage High capacity of transactions storage (more then 60 000 transactions) Complete recording of events and operating status Secured back-up of stored data Compact design for easy installation Because of its simplified design, Equalis S field batch controller has a drastically reduced installation cost. Its compact housing allows easy installation on aircraft refuelers, tank trucks and compact assemblies. Comprehensive automation and control functions Management of overfilling sensors and security devices Direct management of additives injection Management of engine start-up and acceleration Seal parcel delivery compatible Pneumatic manifold control Management and control of defueling operation Control of purge valves and pipeline air blasting Side to side transfert

Model Aplication Functions Technical Data - computer EQUALIS S Electronic register, batch controller to be field mounted Calculation of corrected volume and mass Secured back-up of metrological data transactions Management of safety devices (grounding, dead man ) Control of loading valves and blending valves Additive injection control Control of functions associated with the fuel distribution on truck (motor, pump clutch, valve, drain valve, bottom valve, overfill probe) Metrology Meter Inputs PD Meter, mass flow meter, ultrasonic meter, turbine meter Equipment Inputs/Outputs Temperature Inputs Pt 100 Density input Pressure input Corrected volume/mass calculation User interface module Transaction module Enclosures Data storage Associated software package Meter inputs Temperature inputs Current inputs Digital inputs RS485 Modbus or 4-20 ma transmitter 4-20 ma transmitter Calculation of base volume at 15 C, 20 C and 30 C Fuels : ASTM 54B & 60B tables - Ethanol, methyl ester, bio-diesel : ASTM 54C & 60C tables Lubrication oils: ASTM 54D & 60D table - LPG: ASTM API as per NF M80 17 Inputs: meter, temperature (Pt100), current (4-20 ma), binary Display : graphic screen, 240 x 128 pixels, backlight, volume resolution : 999999 points Display repeater*: graphic screen, 240 x 128 pixels, backlight, 999999 points Keyboard: numeric, antivandalism design Push buttons: pre-programmed, start/stop cycle Power supply, relays outputs, databus User interface module : aluminum base with epoxy coating Transaction module (ATEX version) : aluminum Transaction module (non ATEX version) : polycarbonate 60 000 transactions Maintenance and configuration tool 1 or 2 inputs dual-pulse with flow direction Intrinsic safety or NAMUR* 1 or 2* inputs (4-wire Pt100) 1 or 2* for pressure, temperature and density measurements (in preparation) 15 inputs (intrinsic safety) and 2* input (NAMUR) for grounding system, overfilling system, additive volume, emergency stop Digital outputs 10 (+10*) relays (250V, 10A) for valve commands, pump, alarm, additive injection control Pulse outputs Current output 1 volume output for seal parcel delivery & additive injection control 1 for rate of flow Databus 1 RS232 port : printer 1 RS232 port: communication with data capture system 1 RS485 or Ethernet TCP/IP port (upon request): communication with data capture system and measurements inputs 1 USB port: data extration and software updating Supported protocols : Modbus, Rubis/Saphir, IFSF (in preparation) Operating conditions Ambient temperature Standard : -20 C to +55 C - Option : -40 C to +55 C (compact version) ATEX and IEC Ex Certification for potentially explosive atmospheres Zone 1 II 2 (1) 1 G Custody transfer approval Protection class Power supply IP66 19 to 36 VDC - 12VDC in preparation Evaluation certificate EC/MID Type compliance certificate OIML R117-1 API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface module Transactions module (ATEX version) Transactions module (non ATEX version) Compact version (all-in-one flow computer) 216 x 285 x 71 (without cable gland) 260 x 359 x 69 (without cable gland) 278 x350 x115 (without cable gland) 278 x350 x192 (without cable gland) 5.0 kg 5.7 kg 8.5 kg 16.0 kg *Option Headquarters and Sales Department PARIS NORD II Bat. le Gauguin - 47, allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex France Phone: +33 (0)1 48 63 02 11 E-mail: sales@satam.eu Web: www.satam.eu Your local contact IFC Inflow Unit 3, Ryder Way, Basildon, Essex, SS13 1QH, United Kindom Phone: +44 (0) 1268 596 900 E-mail: sales@ifcinflow.com www.ifcinflow.com As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. B085-IFC-GB-REV1-09/17-Marketing Satam Design & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Countum Group Countum Group Master meter ZCM 17 The Satam Master Meter product range is dedicated to periodic calibration of custody transfer measuring equipment. The ZCM 17 is a working standard that can be used regularly to check and calibrate measuring instruments or measuring systems. With minimal dimensions, it can easily be moved to several different sites without the requirement for lifting tools. Equipped with an Equalis electronic register that ensures linearization of measurements, it can be used with liquids of various viscosities without no loss of accuracy. computers meters Measuring systems Accessories Sector of application Oil depots For oil product reception and loading stations for tank truck, tank car and ships. Hydrocarbon transportation Distribution of fuel oil or fuel by road tanker. Aircraft refuelling Aircraft dispensers and aircraft fuelling tankers. Army Depot supplies and loading of trucks. Transport companies Refuelling of locomotives, trucks and public transport coaches. Marine applications Refuelling of ships. Mining sites Refuelling of trucks or site machinery. Design of the master meter Robust construction Positive displacement meter with moving blades. Modular design Available with mechanical or electronic register. Calibration for different viscosities Supplied with one calibration certificate per each operating viscosity. Key points Compact design Calibration device of reduced weight and dimensions. Possibility to move the ZCM 17 to different sites without the requirement for lifting tools Self powered technology Functioning of the mechanical register version without any power supply. Modular design Wide range of accessories to create your customized calibration device. Can be installed on a trolley as mobile calibration equipment. Stability and accuracy of measurements Stable and accurate volume measurement without any influence of installation position. meter manifold separated from measurement chamber to eliminate any possible influence of external mechanical stresses on measurement accuracy.

Technical data - Master meter ZCM 17 Model ZCM 17 24 48 80 150 250 330 Application Master meter dedicated to calibration of custody transfer volume measuring equipments Max. Operating flowrate m 3 /h - L/mn - USGPM 24-400 - 105 48-800 - 210 80-1333 - 360 150-2500 - 660 250-4166 - 1100 330-5500 - 1453 Min. Operating flowrate m 3 /h - L/mn - USGPM 2.4-40 - 10.5 4.8-80 - 21 8-133.3-36 15-250 - 66 25-416.6-110 33-550 - 145 Measured parameters Measured liquids Connections Operating volume Base volume (only for ZCM 17 IE) Petrol, premium fuels, diesel, E5 E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methyl ester oils Flanges or dry couplings* 2 x 3 m hoses* Meter Diameter 2" 2" 3" 4" 6" 8" Versions ZCM 17 IM ZCM 17 IE Register Mechanical register (VR) Total volume with reset: 5 digits Total volume without reset: 8 digits Electronic register (Equalis) Total volume: 6 digits Secure storage of ZCM 17 calibration curves Calculation of base volume Volume display Operating volume Operating volume, base volume rate display Included with IDI module L/mn or m 3 /h Included Calibration curve 7 flowrate values with 2 values per flowrate One curve per operating viscosity Calculation of base volume Manual calculation Automatic calculation Temperature measurement* Local display Pt 100 Pressure measurement* Isolating valve* Drainage equipment* Trolley* Local display Ball valve located downstream the PD meter Manual drainage pump with purge valve and 2 release valves Calibration device mounted on chassis with 4 pivoting wheels Operating conditions Pressure 10 bar max. Viscosity 50 cst max. Liquid temperature -10 C to +80 C Ambient temperature Standard : - 25 C to + 55 C - Option : - 40 C to + 55 C Contact us for higher or lower temperatures Metrological performances Volume accuracy < 0,1% < 0,05% with linearization Volume repeatability < 0,02% Temperature accuracy Calibration certificate - Linearization curve PD meter ZC17-24 ZC17-48 ZC17-80 ZC17-150 ZC17-250 ZC17-330 <± 0.5 C Calibration certificate according to OIML R117 Installation Electrical power supply No (self-powered device) 24 VCC or 230 VCA ATEX certification Zone 1 ; II 2 G * : optional supply Headquarters and Sales Department PARIS NORD II Bat. le Gauguin - 47, allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex France Phone: +33 (0)1 48 63 02 11 E-mail: sales@satam.eu Web: www.satam.eu Your local contact IFC Inflow Unit 3, Ryder Way, Basildon, Essex, SS13 1QH, United Kindom Phone: +44 (0) 1268 596 900 E-mail: sales@ifcinflow.com www.ifcinflow.com As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. B086-IFC-GB-REV2-09/17-Marketing Satam Design & printing: TACTIC IMPRESSIONS - 01 39 86 19 08

Countum Group Metering system for truck and railcar loading ZCE 6 ZCE 6 horizontal metering unit is designed for truck and train tankers loading stations in a top or bottom configuration. ZCE 6 space-saving configuration enables easy installation in smaller facilities and in compact pipeline network. computers meters Measuring systems Accessories Sectors of application Tanker trucks and railcars loading applications Preparation of bio-fuels by means of online or batch blending Measurement of white products and bio-fuels High reliability measuring system Ready-made technology ZCE 6 horizontal vertical measuring systems are completely assembled, wired and tested in the production facility in order to ensure a maximum reliability. Measurement stability and accuracy Measurement accuracy guaranteed over a period of many years without any deviation in the calibration curve. Key points Low installation costs Complete and ready-to-install measuring unit including strainer, air eliminator, PD meter, valve and register. Low maintenance costs Simple and robust construction with minimal moving parts Interchangeable mechanical components. Space-saving installation Compact metering unit for installation in smaller areas and in vertical pipeline networks. A safe and easy-to-use technology Automatic gas elimination system to start loading operation with empty pipe. Filtering system with automatic clogging detection (option). Modular design Extensive line of accessories to create customized measurement applications. Communication Direct communication with supervisory system with the electronic register version.

Technical data - Horizontal metering system Measuring system ZCE 6-80 ZCE 6-150 ZCE 6-250 Maximum flow rate m 3 /h - L/mn - USGPM 80-1333 - 360 150-2500 - 660 250-4166 -1100 Application Tanker truck and rail car loading application, product transfert Measured parameters Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature* (* : only for electronic register version, ** : option for mechanical register version) Measured liquids Petrol, premium fuels, diesel, E5 E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methyl ester, oils Equipment Strainer - Gas elimination device EC 31 EC 32 EC 39 50 to 450 μ filtering (270 to 40 Mesh) depending on the liquid Gas release controlled by float and differential valve PD meter ZC 17-80 ZC 17-150 ZC 17-250 Temperature measurement 4-wire Pt100 (option for electronic calculator version) Multi-function valve Small and large flow, authorisation, flow limitation XAD 37 DN3 XAD 36 DN4 XAD DN6 electrical control mechanical control - register Mechanical register model VR with pre set*, printer*, pulser* (* : option) or Equalis flow computer with display, secure archiving of transactions Operating conditions Pressure 10 bar max. Viscosity 20 cst max. Contact us about higher viscosities Liquid temperature -10 to +80 C Ambient temperature Standard: -25 to +55 C ; Option -40 to +55 C Ask us about higher or lower temperatures Metrological performances Accuracy ±0.15 % - Option ±0.1 % - for measurement range of 10 : 1 Repeatability ±0.02 % Temperature accuracy 0.5 C Installation ATEX certification Zone 1 ; II 2 G Custody transfer approval MID - CE Evaluation Certificate n LNE-11052 (ZC17) Type compliance certificate OIML R117 n LNE-24351 (ZC17) Dimensions (mm) and weight ZCE 6-80 ZCE 6-150 ZCE 6-250 Distance between flanges (A) 970 1081 1456 Width (B) 456 524 640 Height (C) 875 875 - Height (C1) - - 1110 D 459 459 - D1 - - 700 Weight (kg) 190 230 405 B A C C1 D D1 Headquarters and Sales Department PARIS NORD II Bat. le Gauguin - 47, allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex France Phone: +33 (0)1 48 63 02 11 E-mail: sales@satam.eu Web: www.satam.eu Your local contact IFC Inflow Unit 3, Ryder Way, Basildon, Essex, SS13 1QH, United Kindom Phone: +44 (0) 1268 596 900 E-mail: sales@ifcinflow.com www.ifcinflow.com As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. B073-IFC-GB-REV0-09/17-Marketing Satam Design & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Countum Group Countum Group On board metering unit EMS 24 & EMS 48 EMS 24 - EMS 48 are compact metering units designed to measure pressurized hydrocarbons on road tankers, especially fuel delivery tankers. They can be fitted with mechanical register or Equalis electronic flow computer for a secure archiving of the transactions and for a control of all the actions linked to delivery operations. computers meters Measuring systems Accessories Sector of application On-board measurement on tank trucks Preparation of biofuels by means of on-line batch blending Measurement of white products and of biofuels Key points Low installation cost Complete and ready to install measuring unit including strainer, air eliminator, PD meter, valve and register. Self powered technology No need for power supply with mechanical register version. High reliability measuring system A compact metering unit Significant reduction in the dimensions and weight of the unit. Simplified installation on the fuel delivery tanker. A rugged and reliable metering technology PD meter with moving blades. Excellent long term stability. Integrated strainer and air eliminator. Measurement accuracy independent of liquid viscosity. High flexibility of installation Fully assembled and tested in production facility. Low maintenance costs Simple and robust construction with minimal moving mechanical parts. Stability of measurements Measurement accuracy guaranteed over a period of many years without drift of the calibration curve. Multi purpose operation The flow computer version controls the automatic system linked to deliveries such as control of bottom valves, pump engagement. Versatile communication with flow computer version Secure archiving of metrology data and transactions. Transmission of transactions to data processing system via data bus or memory stick.

Technical data - On board metering system Measuring system EMS 24 EMS 48 Maximum flow rate m 3 /h - L/mn - USGPM 24-400 - 105 48-800 - 210 Applications Measured parameters Measured liquids On-board metering system for tank truck, truck loading application, in-line blending Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature* (* : only for electronic register version) (** : option for mechanical register version) Petrol, premium fuels, diesel, E5 E85, bio-diesel, ethanol, methanol, kerosene, Fatty acid methyl ester oils Equipment Strainer & gas elimination device Model EC 42 / FS 24 Horizontal stainless steel 450 µm basket filter (diesel fuel) or 200 µm (petrol) Aluminum housing with non return valve Gas release controlled by float and differential valve Temperature measurement Multifunction valve 3-way valve (option) Register 4-wire Pt 100 (option for electronic calculator version) XAD 39 available in mechanical or electrical version XAD 54 pneumatic version Low and high flow rate, authorization, restriction of flow rate Distribution to hose on reel or to short hose Mechanical register model VR, preset*, printer*, pulser*, (* : option) or Electronic register model Equalis with display, secure archiving of transactions Operating conditions Pressure 8 bar max. -10 bar upon request Viscosity 20cSt max. Consult us about higher viscosities Liquid temperature -10 to + 80 C Ambient temperature Standard -25 to + 55 C ; Option -40 to + 55 C Contact us about higher or lower temperatures Metrological performances Volume accuracy ±0.15 % - Option ±0.1 % - for measuring range 10 : 1 Volume repeatability ±0.02 % Temperature accuracy 0.5 C Installation ATEX certification Zone 1 ; II 2 G Custody transfer approval PD meter ZC 17-24 ZC 17-48 MID CE type approval n LNE11123 Type Compliance certificate OIML R117 n LNE-24351 Dimensions (mm) and weight EMS 24 EMS 48 Length (A) 785 863 Width (B) 461 461 Height (C) 662 662 Weight (kg) 56 62 C 210 B A Headquarters and Sales Department PARIS NORD II Bat. le Gauguin - 47, allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex France Phone: +33 (0)1 48 63 02 11 E-mail: sales@satam.eu Web: www.satam.eu Your local contact IFC Inflow Unit 3, Ryder Way, Basildon, Essex, SS13 1QH, United Kindom Phone: +44 (0) 1268 596 900 E-mail: sales@ifcinflow.com www.ifcinflow.com As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. B028-IFC-GB-REV0-0917-Marketing Satam Design & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Countum Group Countum Group Positive Displacement Meter ZC 17 The SATAM Positive Displacement Meter (PD meter) is a system with freely-moving blades used to measure petroleum products such as fuels, bio-fuels and refined liquid hydrocarbons and non corrosive chemicals. Its simple design with only two pairs of blades and one moving rotor makes it exceptionally robust and allows the user to make significant savings on maintenance costs. computers meters Measuring systems Accessories Sectors of application Oil depots For oil product reception and loading stations for tank truck, tank car and ships. Hydrocarbon transportation Distribution of fuel oil or fuel by road tanker. Aircraft refuelling Aircraft dispensers and aircraft fuelling tankers. Army Depot supplies and loading of trucks. Transport companies Refuelling of locomotives, trucks and public transport coaches. Marine applications Refuelling of ships. Mining sites Refuelling of trucks or site machinery. Key points Reduced pressure loss 0.3 to 0.5 bar at maximum flow rate. Low maintenance costs Simple and robust design with mechanical components interchangeable between the different models. Stability of measurements Accuracy of measurement guaranteed over a period of many years without any drift in the calibration curve. Modular design Wide range of accessories for performing customized measurement applications. Robust construction meter manifold is separated from measurement chamber to eliminate any possible influence of external mechanical stresses on measurement accuracy. Few moving parts. Operating principle The product enters the measuring chamber following the direction of the arrow. The rotor and blades assembly (1-2) is set in motion by the pressure of the liquid on blades. A certain amount of liquid (3) is held between 2 blades and then directed to the discharge manifold. The volume of liquid measured at each rotation is therefore equal to 4 times the measured quantity (3). The smooth curves the meter pieces provide a steady, non-fluctuating flow resulting in low head loss. 1 3 2

Technical data - PD meter ZC 17 Model ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330 Application Custody transfer metering of liquid hydrocarbons Max. rate (m 3 /h - L/mn - USGPM) 12-200-53 24-400-105 48-800-210 80-1333-360 150-2500-660 250-4166-1100 330-5500-1453 Min. rate (m 3 /h - L/mn - USGPM) 1.2-20-5.3 2.4-40-10.5 4.8-80-21 8-133-36 15-250-66 25-416-110 33-550-145 Connections DN 2 2 2 3 4 6 8 Flanges (standard) Standard Satam ASA 150 RF Flanges (option) ASA 150 RF DIN28463TW1 DIN28463TW3 Other flanges upon request Materials Manifold Aluminum Steel or ductile iron or aluminum Steel or ductile iron Casing Aluminum Aluminum or Ni resist Iron Ductile iron or Ni resist iron Front and back cover Carbon steel with protective coating Rotor - Blades - Gaskets Aluminum - Graphite - Viton (option nitrile) Operating conditions Max. pressure (operation) 10 bar -150 PSI Max. pressure (EC/MID certificate) 6 bar (gasoline, kerosene) 8 bar 8 bar (diesel oil, ethanol) 10 bar Max. viscosity MID : 20mm²/s (cst) - Operation : 800 mm²/s (cst) MID : 57mm²/s Liquid temperature -10 C to +55 C Ambient temperature Standard : -20 C to +55 C - Option : -40 C to +55 C Consult us for higher or lower temperatures Pressure drop at max flowrate, 3,7 mm²/s (cst) 0.45 0.35 Internal construction Cyclic volume (L - USG) 0,33-0.08 0,40-0.10 0,80-0.21 2,27-0.6 4,54-1.2 6,82-1.8 9.09-2.4 Metrological performances Accuracy < 0,15 % / Option < 0,1 % For 10 : 1 measuring range Repeatability < 0,02 % Installation ATEX certification Zone 1 - II 2 G Custody transfer approval EC-MID Evaluation Certificate N LNE-11052 Type Compliance Certificate OIML R117 n LNE-24351 Dimensions (mm) and weight ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330 Distance between flanges (A) 180 180 180 356 432 400 400 Width (B) 290 290 290 356 432 400 400 Depth (C) with mechanical register with pulser 220 186 220 186 246 266 365 272 492 399 620 526 746 653 Height (D) with mechanical register with pulser 368 260 406 260 406 260 502 502 521 521 568 568 625 625 Weight (kg) with mechanical register 18 22 26 75 95 155 200 Flanges positions Flanges ASA150 with mechanical register PH1, PH2 Flanges ASA150 with pulser PH1, PH2, PV1, PV2, PV3, PV4 PH1, PH2, PV1, PV2, PV3, PV4 Flanges TW with mechanical register or pulser - - - PH1, PH2, PV1 to PV10 PH1, PH2, PV1 to PV6 - - ZC 17-12, 24 & 48 ZC 17-80, 150, 250 & 330 Headquarters and Sales Department PARIS NORD II Bat. le Gauguin - 47, allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex FRANCE Phone: +33 (0)1 48 63 02 11 E-mail: sales@satam.eu Web: www.satam.eu Your local contact IFC Inflow Unit 3, Ryder Way, Basildon, Essex, SS13 1QH, United Kindom Phone: +44 (0) 1268 596 900 E-mail: sales@ifcinflow.com www.ifcinflow.com As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. B037-IFC-GB-REV3-09/17-Marketing Satam Design & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Countum Group Countum Group Vertical measuring unit for truck and railcar loading ZCE 5 ZCE 5 vertical metering unit is designed for truck and train tankers loading stations in a top or bottom loading configuration. ZCE5 space-saving configuration enables easy installation in smaller facilities and in compact pipeline network. computers meters Measuring systems Accessories Sectors of application Tanker trucks and railcars loading applications Preparation of bio-fuels by means of online or batch blending Measurement of white products and bio-fuels Additive injection control High reliability measuring system Ready-made technology ZCE 5 vertical measuring units are completely assembled, wired and tested in the production facility in order to ensure a maximum reliability. Measurement stability and accuracy Measurement accuracy guaranteed over a period of many years without any deviation in the calibration curve. Key points Low installation costs Complete and ready-to-install compact measuring unit including strainer, air eliminator, PD meter, valve and register. Low maintenance costs Simple and robust construction with minimal moving parts. Interchangeable mechanical components. Space-saving installation Compact metering unit for installation in smaller areas and in vertical pipeline networks. A safe and easy-to-use technology Automatic gas elimination system to start loading operation with empty pipe. Filtering system with automatic clogging detection. Modular design Extensive line of accessories to create customized measurement applications. Communication Direct communication with supervisory system.

Technical data - Vertical measuring unit for loading Model ZCE 5-80 ZCE 5-150 Maximum flow rate m 3 /h - L/mn - USGPM 80-1333 - 360 150-2500 - 660 Connections Flanges 3'' ASA 150 RF 4'' ASA150 RF Description Compact vertical metering unit Measured parameters Measured liquids Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature* (* : only for electronic register version, ** : option for mechanical register version) Petrol, premium fuels, diesel, E5 E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methyl ester, oils Equipment Strainer - Gas elimination device Model EC 29 50 to 450 filtering (270 to 40 Mesh) depending on the liquid Gas release controlled by float and differential valve Temperature measurement PD meter ZC 17-80 ZC 17-150 4-wire Pt100 (option for electronic calculator version) Multi-function valve XAD 37 XAD 36 Small and large flow authorisation, flow limitation Electrical control or mechanical control register Mechanical register model VR with pre set*, printer*, pulser* or Equalis electronic register with display, secure archiving of transactions Operating conditions Pressure 10 bar max. Viscosity 20cSt max. Contact us about higher viscosities Liquid temperature -10 à +80 C Ambient temperature Standard -25 to +55 C ; Option -40 to +55 C Contact us about higher or lower temperatures Metrological performance Volume accuracy ±0.15% - Option ±0.1% - for measurement range of 10 : 1 Volume repeatability ±0.02 % Temperature accuracy 0.5 C Installation ATEX certification Zone 1 - II 2 G Custody transfer approval MID - CE type approval n LNE 6184 Type compliance certificate OIML R117 n LNE-24351 Dimensions and weight net weight without extension 200 kg 240 kg Net weight with extension 235 kg 275 kg Headquarters and Sales Department PARIS NORD II Bat. le Gauguin - 47, allée des Impressionnistes BP 85012 Villepinte 95931 Roissy CDG Cedex France Phone: +33 (0)1 48 63 02 11 E-mail: sales@satam.eu Web: www.satam.eu Your local contact IFC Inflow Unit 3, Ryder Way, Basildon, Essex, SS13 1QH, United Kindom Phone: +44 (0) 1268 596 900 E-mail: sales@ifcinflow.com www.ifcinflow.com As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice. B026-IFC-GB-REV0-09/17-Marketing Satam Design & printing : TACTIC IMPRESSIONS - 01 39 86 19 08