PANEL FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

Similar documents
UNIT FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

PANEL FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

INSTRUCTION AND USE MANUAL

CONTROL AND PROTECTION PANEL FOR TRACTOR-PUMP CTR-087/0N THE TRACTOR/PUMP IS STOPPED WHEN THERE ARE ANOMALIES (VIA ELECTROMAGNET) CONCERNING:

CONTROL UNITS FOR IRRIGATION MOTOR PUMPS AND PUMP WATER PRESSURE CONTROL

Fire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual

Type CIM-131. ELCOS SRL - Parma - GB - CIM-131 1

DIESEL-EN - User Manual

CONTROL, PROTECTION AND VISUALIZATION ELECTRONIC MANUAL CEN- TRALITE FOR GENERATING SETS CMD2.0

FIREPAK-E21 & FIREPAK-ED21

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT

SPEEDRIVE INSTRUCTIONS MANUAL

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

PSM72H Push-Button Start Module

USER INSTRUCTIONS FOR SLIDING DOORS

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM FOR EMX P10 ROTOR SIZE

DEEP SEA ELECTRONICS PLC

ENGINE PROTECTION BOARD PDM1

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

ECONOMISER SERIES E2T USER MANUAL

AUE-AUD-AU2E AU2D-AUED

DIESEL Engine Fire Pump Controllers Features

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Controller Specification Sheet

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

USE AND MAINTENANCE MANUAL AQUA IONIC PLUS. Aqua Ionic Plus MAN00016 Rev. B / 22

ELECTRIC AND ELECTRONIC ACCESSORIES. motralec

Operating manual UPS - System

PRO series programmer

Red #22 Power. Red #14. Brown #18. Ign/Acc/Start. White#14. Tachometer Foot-Brake Door Pin Pos Trunk/Hatch (open) (-) while running Lock Arm

GENERALITIES TECHNICAL FEATURES

The measurements module provides the following engine features information:

DEEP SEA ELECTRONICS PLC

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

MAINTENANCE AND USER MANUAL

PowerView PV380-R2 Mechanical Configuration

E Series CE Approved Intermittent Pilot Ignition Control

GL1200T Cut & Seal. (GL1200 Seal only)

Operating Instructions

P445 Series Electronic Lube Oil Control

DEEP SEA ELECTRONICS PLC

GCU-10. Automatic Engine Control Unit Operators Manual

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

KONGSKILDE KONNECT 1000

OS3050 OS3051. Controller for reverse osmosis plants. Instruction manual. Softwareversion 3.04

INSTALLATION GUIDE Table of Contents

Flight Systems. Replacement for KASSEC DESCRIPTION

TITANO 400V SLIDING GATE OPENER

Sieve Shaker 200mm/300mm - 8/12 inch SV003

USER MANUAL AND INSTALLATION GUIDE ENGINE RPM AND NOS SHIFT COUNTER NOS DELAY TIME IN SECONDS NOS START PERCENT NOS FINAL PERCENT

Nortoft Electronic A/S Sejrupvej 38 Sejrup DK-7323 Give Denmark

STANDARD OWNER S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

PULSE-8: MASTER PULSATION CONTROL

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

SDM72 Start on Demand Modules

Three-Phase Soft Starters

D-67 Charger La Palma Ave., Suite 103, Yorba Linda, CA Ph: (714) Fax: (714)

DKG-114 MANUAL AND REMOTE START UNIT

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Level Measuring Sensor for Diesel Fuel Tanks

w.get2itparts.com Viper 90R-4 Dies After Shifting Or Indicator Lights Blink SCL /24/2005

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

POLE STAR PRO. Installation and instruction manual.

Instruction Manual. Rotating Torque Sensor Type 4501A. Version Q/QA (with standard square connections) Version R (with shaft ends)

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

IGLOO IGLOO EASY INSTRUCTION MANUAL

Electric Motor Controls BOMA Pre-Quiz

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

SIZING OF SOLAR GENERATOR

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Operating manual and installation instructions ENGLISH. Electronic engine remote control. Copyright 2001 Vetus den Ouden n.v.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR

HD [ GB ] Tipping bucket rain gauge

Installation & Calibration

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Automatic concealed bollards 275 H600 and 275 H800 Control station

THREE-PHASE TR BATTERY CHARGER

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Installation and Operation

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Wireless Radiator Valve

Electrical operating instructions

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

3.1 LH Sequential Multiport Fuel Injection System (LH-SFI) Engines 104, 119

Tina 4A Connection block

Lt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

SLIDE NEW CONTROL BOARD

Electronics. Permanent Operation Microprocessor Burner Control ESA ESTRO-PO (E7014PO rev /05/2013)

Operating Instructions

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Transcription:

PANEL FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET INSTRUCTION AND USER MANUAL TYPE CEM-250 MADE TO: By simply starting, it automatically controls the motor pump Pump water electronic pressure gauge Digital pump water pressure gauge Assembly also on the machine and in the open air. PROTECT motor pump sets by stopping them in the event of: low oil pressure over-temperature belt breakage minimum fuel level low coolant level low pump water pressure pump water overpressure A available DISPLAY on the panel the functions of: hour-meter oil pressure gauge water or oil thermometer tachometer pump water pressure gauge timer fuel level gauge pump protection exclusion battery and oil lights protections intervention emergency stop PARMA ITALY Tel. +39 052/77202 Fax +39 052/27028 GB CEM-250 E-mail: info@elcos.it - HTTP://www.elcos.it

BRIEF INSTRUCTIONS After starting, the motor pump protects itself automatically ENGINE OIL PRESSURE IS DISPLAYED ENGINE WATER OR OIL TEMPERATURE IS DISPLAYED MOTOR PUMP OPERATING SPEED IS DISPLAYED PUMP WATER PRESSURE IS DISPLAYED A AVAILABLE CUMULATIVE ALARM THE FUEL LEVEL IS DISPLAYED ACCUMULATED OPERATION HOURS ARE DISPLAYED PRESS IF YOU WANT TO SET WORKING TIME(UPTO24 HOURS) STOP % STOP C RPM PRESS TO SELECT THE DISPLAYED FUNCTION, EACH TIME IT IS PRESSED, THE INSTRUMENT INDICATED BY THE DISPLAY CHANGES. WATER PRESSURE IS REGULAR EMERGENCY STOP PRESS TO ADJUST WATER PUMP ELECTRONIC PRESSURE SWITCH h! M A P PRESS UNTIL THE 2 SIGNS START FLASHING TO EXCLUDE PUMP PROTECTION. TO RE-ACTIVATE PROTECTION, PRESS AGAIN UNTIL THEY SWITCH OFF. PUMP PROTECTION IS ACTIVE THE BATTERY IS NOT CHARGING LOW ENGINE OIL PRESSURE 0 AUTȦVV. ENGINE PROTECTIONS ARE ACTIVE www.elcos.it STOPPAGE DUE TO LOW FUEL LEVEL STOPPAGE DUE TO INSUFFICIENT ENGINE OIL PRESSURE STOPPAGE DUE TO LOW COOLANT LEVEL STOPPAGE DUE TO LACK OF BATTERY CHARGING (BELT BREAKAGE) STOPPAGE DUE TO HIGH ENGINE TEMPERATURE STOPPAGE DUE TO LOW PRESSURE OR PUMP WATER OVERPRESSURE OR ELECTRONIC PRESSURE GAUGE (TRANSMITTER) INTERRUPTED. IN THIS CASE, THE ANOMALY IS HIGHLIGHTED BY THE FLASHING WARNING LIGHT. LOW PRESS. OVERPRESS. DISCONN'ED 0 AUT. AVV. START KEY - OFF - STOPPAGE IN ALL OPERATING CONDITIONS - RESTORE PROTECTIONS, CANCEL PUMP PROTECTION EXCLUSION AND TIMER, DEACTIVATE INSTRUMENTS. - CONTROL PANEL SUPPLY - TURNS ALL THE LIGHTS ON FOR 2 SECONDS ( EFFICIENCY CHECK ) - PRESSURE SWITCH ADJUSTING (SEE PAGE 3) - MOTOR PUMP START UP 2 GB CEM-250

ADJUSTING THE PUMP WATER ELECTRONIC PRESSURE GAUGE (TRANSMITTER) The pressure gauge is a precision device that controls the water pressure. It controls the pressure entering the system, replacing the conventional pressure switch. PUMP PROTECTION P The protection of the pump is enabled when the PUMP PROTECTION ACTIVE information comes on, after the water pressure has been steady for 2 consecutive minutes and in any case after 0 minutes from starting of the engine. Intervention of the protection (5 seconds after the pressure goes up or down by two bars) stops the engine and is shown on the display: LOW PRES. Low pressure or OVERPRESS. Pump water overpressure WORKING PRESSURE OPTIONAL SETTING PRESSOSTAT 7 Press to select the pump water pressure gauge Press to manually set the intervention of the LOW PUMP WATER PRESSURE protection. OVERPRESSURE remains set to two bars, this value is added to the working pressure (for example, working pressure 9 bar overpressure bar) TIMER Enabled with key on AUT, it makes it possible, if necessary, to have the motor pump work for an adjustable length of time (24 hours maximum), at the end of which it stops and the WORK TIME OVER sign lights up on the display. STOP The work time is set by pressing the push-button ( lights up) until the desired value appears on the DISPLAY. On releasing the push-button, the timer automatically starts working, continously displaying the remaining work time. CANCELLING THE SET TIME To zeroing the set time there are two methods: - keep the push-button pressed until it reaches zero. - by turning the starter key onto "ZERO" (the engine pump will stop). PUMP PROTECTION EXCLUSION ( ENABLED ONLY WITH ENGINE RUNNING) The push-button excludes pump protection: - exclusion is obtained by keeping it pressed for at least 3 consecutive seconds; the function is indicated by the two intermittent lights. - this exclusion is cancelled by pressing the push-button again or by turning the start key onto "ZERO". OIL AND BATTERY INDICATOR LIGHTS Lit up with key on "AUT", they switch off with the engine running and regular oil pressure and battery charge system. ENGINE PROTECTIONS The engine protections are enabled when the ENGINE PROTECTIONS ACTIVE light M comes on (20 seconds after the end of starting impulse and however minute after positioning the key on AUT ). Interventions of the protection probes (fitted on the engine), indicated by the relevant lights, stop the engine, they are memorised and can be split into two groups. Delayed by 2 seconds for: Delayed by 5 seconds for: - OIL PRESSURE SWITCH - OVERTEMPERATURE SWITCH - A - BATTERY CHARGE ALTERNATOR (ALTERNATOR BELT BREAKAGE) - FUEL LEVEL SWITCH - Fuel reserve flashing signal: 20% fuel reserve (T) (WITHOUT ENGINE STOP) - Signal always on: stop for minimum fuel level (W) - PROBE FOR COOLANT LEVEL GB CEM-250 3

FOR RADIATORS WITH PLASTIC EXPANSION TANK INSTALLING THE CONTROL UNIT COOLANT LEVEL PROBE FOR RADIATORS WITH METAL EXPANSION TANK 55 SCREW ELECTRODES 55 ROD ELECTRODE WARNING IF THE FUNCTION - LOW COOLING LIQUID LEVEL IS NOT USED: CONNECT / ORANGE WIRE TO EARTH / ORANGE! TO REPLACE THE FUSES, REMOVE THE COVER FROM THE CONTROL UNIT PUMP WATER PRESSURE TRANSMITTER CABLE /4 GAS 3/8 GAS The unit has been designed to control stopping with an ELECTROMAGNET SET UP WATER OR OIL THERMOMETER OIL PRESSURE GAUGE 7 EXCITED WHILE RUNNING 85 30 86 87 SOLENOID to close the fuel BLACK/VIOLET STOP SYSTEM SET UP To stop with the SOLENOID VALVE cut and isolate the BLUE/BROWN lead To view the water/oil THERMOMETER and the oil pressure GAUGE, connect the transmitters to the respective wires of the unit, then CUT and isolate the BLACK/VIOLET wire STOP SYSTEMS EXCITED WHILE RUNNING (with EMERGENCY button) SOLENOID to close the fuel BLUE/BROWN EMERGENCY BUTTON 85 30 86 87 WHITE- ORANGE WHEN THE EMERGENCY BUTTON IS MOUNTED REMOVE THE 4-20 BRIDGE (LOCATED INSIDE THE PANEL) 4 20 EXCITED IN STOP MODE WARNING! : IT IS NOT POSSIBLE TO MOUNT THE EMERGENCY STOP BUTTON ONASTOP SYSTEM WITH ELECTRO- MAGNETS 85 30 86 87 2 ELECTROMAGNET to activate the engine stop lever TACHOMETER ADJUSTMENT 4 Run the engine at a costant and known rpm value (for example by means of a portable revolution counter) RPM Select the instrument TACHOMETER, keep the button depressed for at least 5 seconds and simultaneously press increase or decrease until the correct reading appears on the display. Release the buttons and wait until OK appears on the display. GB CEM-250

FROM 5/54 OF START KEY, USABLE FOR HEADLIGHT OR AUXILIARIES 55 GREY WHITE/RED 26/28 INSTALLING THE CONTROL UNIT 3A MAX CONNECTOR 9 6 3 GREEN 0 BROWN (ONLY FOR PERMANENT MAG.) 3 8 5 2 WHITE 7 4 + BATTERY 3A MAX 2/7 WIRING DIAGRAM /ORANGE A 9 SKY-BLUE 4 2 WHITE/GREEN 97 4 BLACK RED ORANGE/BROWN WHITE/VIOLET 40A MAX 30 50 CONNECTOR 6 3 ORANGE 5 2 8 40 4 ORANGE/ BLUE T INDICATOR W RESERVE 3A MAX 57 RED/GREEN CABLE 2,5m INSULATE POSSIBLE CABLES NOT CONNECTED 73 STOP SYSTEMS SEE PAGE 4 PRE-EXCITATION DO NOT USE PERMANENT MAGNETS RED 26 28 27 27 CONNECTION SYSTEM FOR EXTRACTING THE W TERMINAL IN PRE-EXCITATION BATTERY CHARGE ALTERNATORS. (BOSCH, MARELLI, LUCAS, ECC...) CHARGE BATTERY ALTERNATOR: R W B+ D+ + LE G R G L + B C WHITE/RED + BATTERY GREEN BROWN WHITE/RED + BATTERY GREEN BROWN TO TACHOMETER (WHITE/RED WIRE) To diode bridge (inside alternator) } ACCESSORIES AVAILABLE ON REQUEST (2/7) ELECTROMAGNET OR SOLENOID VALVE (3) OIL PRESSURE SWITCH (4) THERMOSTAT (8) FUEL FLOAT FOR INDICATORAND RESERVE (97) OIL PRESSURE TRANSMITTER (2) TEMPERATURE TRANSMITTER (55) COOLANT LEVEL PROBE (73) PUMP WATER PRESSURE TRANSMITTER (SUPPLIED) (26) PERMANENT MAGNETS CHARGEALTERNATOR (27) BATTERY CHARGEALTERNATOR REGULATOR (28) PRE-EXCITATION CHARGEALTERNATOR (40) STARTING MOTOR (4) BATTERY (57) GENERALALARM LIGHT (9) AAVAILABLE FOR PROTECTION PROBE SELECT LANGUAGE The language set up is ITALIAN; the languages that can be selected are:english, SPANISH, GERMAN and FRENCH. GB CEM-250 5 ON Move DIP switch to ON ITALIANO ON Press to select the desired language ENGLISH Move DIP switch to OFF Press and wait for OK to be written

OPERATION CONTROLLING THE CONNECTION OF THE PUMP WATER ELECTRONIC PRESSURE GAUGE (Transmitter) Turning the key to the AUT position stops the electronic pressure gauge. Control is activated minute after the completion of the starting pulse. Intervention is highlighted by the relevant indicators and stops the motor pump after 2 seconds. DISCONN'ED flashing warning light To exclude intervention, press the push-button PUMP PROTECTION EXCLUSION. PUMP PROTECTION The pump protection is enabled with the switching on of the ACTIVE PUMP PROTECTION (after 2 minutes of stable water pressure, indicated by the visual signal REGULAR PUMP PRESSURE case, 0 minutes after the start of the motor pump). consecutive and, in any The intervention of the protection (5 seconds after the increase or decrease of the pressure) stops the engine and is indicated by the visual signal for LOW PUMP WATER PRESSURE or WATER PUMP OVERPRESSURE. RESET : is obtained by turning the start key onto "ZERO". STOPPING THE ENGINE PUMP The control unit shuts down the engine in four conditions: - turning the starter key onto "ZERO - protection intervention - timer intervention at the end of the work period - through intervention of the external emergency. The unit adapts to two different stop systems - by working the ELECTROMAGNET for 20 seconds which pulls the STOP lever - by cutting off power to the SOLENOID VALVE shutting off the flow of fuel. GENERAL ALARM This can be obtained by fitting on the outside an optical and/or acoustic signaller to be connected to the RED/GREEN wire. It is activated on protection intervention. EMERGENCY STOP It can be obtained in all functioning conditions, mounting one or more release-type buttons. It is indicated by the visual signal! and enables the general alarm. INSTRUMENT SELECTION The control unit comprises six instruments: h HOUR METER - Total hours of operation (with the engine running the signal pulsates, to indicate the correct functioning of the HOUR-METER). INSTRUMENTS WHICH CAN BE SELECTED IN SEQUENCE BY PRESSING THE BUTTON Each time it is pressed, IT SHOWS the next instrument. WHEN THE TIMER IS set, the duration of the display of the instrument is limited to 30 seconds from the activating of the button; the TIMER then reappears. bar C RMP % 6 - PRESSURE GAUGE - Engine oil pressure - THERMOMETER - Engine oil and water temperature - TACHOMETER - Speed of motor pump - PRESSURE GAUGE - Pump water pressure - INDICATOR - Fuel level percentage } TRANSMTTERS FITTED ON ENGINE ON REQUEST GB CEM-250

S.r.l. Via Naviglio Alto, 24/a-4300 PARMA ITALIA Tel. +39 052/77202 Fax +39 052/27028 E-mail: info@elcos.it HTTP://www.elcos.it CONTROL AND PROTECTION UNIT FOR IRRIGATION ENGINE PUMP TYPE CEM-250 Only for starting and surveillance of the diesel motor pump and stops it if there are anomalies in the parts controlled by probes. It has been designed to be installed also on the machine. NOTICES! Warning: adhere closely to the following advice: - Always install under other equipment which produces or spreads heat. - Always follow the Wiring Diagram on pages 4-5 when making connections. - Check that the line loading and the consumption of the connected equipment are compatible with the technical characteristics on page 8. - All technical interventions must be performed with the engine stationary and terminal 50 of the starter motor disconnected. - Never use a battery charger for the emergency start-up, this could damage the control unit. - To protect the safety of persons and the equipment, before connecting an external battery charger, disconnect the electrical plant terminals from the battery poles. - Never disconnect the battery terminals with the engine running. THIS CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS: - Where the environmental temperature is outside the limits indicated in the Technical Data on page 8. - Where there are high levels or heat from radiation caused by the sun, ovens or the like. - Where there is the risk of fire or explosions. - Where the panel can receive strong vibrations or knocks. ELECTROMAGNETIC COMPATIBILITY This control unit functions correctly only if inserted in plants which conform with the CE marking standards; it meets the exemption requirements of the standard EN50082- but it cannot be excluded that malfunctions could occur in extreme cases due to particular situations. The installer has the task of checking that the disturbance levels are within the requirements of the standards. CONDUCTION AND MAINTENANCE The following maintenance operations should be performed every week: - check that the indicators function; - check the batteries; - check that the conductors are tight, check the condition of the terminals. UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS CONTROL UNIT IS NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS CONTROL UNIT BY TELEPHONING ONE OF OUR TECHNICIANS GB CEM-250 7

85 230 53 DIMENSIONS 47,5 85 85 47,5 M6 CABLES 265 49 84 20 220 TECHNICAL DATA - BATTERY VOLTAGE SUPPLY: 2 Vdc 24 Vdc - VOLTAGE SUPPLY : 8 32V - CIRCUIT LOADING WITH KEYAT ZERO 3 maat 2 V 9mAat24V - MAX CURRENT OUTPUT -(STOPPING) 3 A -(STARTING MOTOR) BLACK 40 A -(GENERALALARM) RED/GREEN 3 A -(AUXILIARY) BROWN 3 A - TEMPERATURE RANGE -0 +60 C - HOUR-METER 4 DIGITS - OIL PRESSURE GAUGE 0 7 bar - PUMP WATER PRESSURE GAUGE 0 6 bar - PUMP WATER PRESSURE TRANSMITTER: MAX. PUMP WATER PRESSURE 2 bar - ENGINE OIL/WATER THERMOMETER +20 +45 C - TACHOMETER 4000 rpm - TIMER ' 24 h - INSTALLATION CONDITIONS FOR EXTERNAL USE - DEGREE OF PROTECTION BOX/CONNECTOR IP23/IP2 - PANEL WEIGHT 3,3 kg - TOTAL WEIGHT 3,7 kg (PANEL + ACCESSORIES + PACKAGE) 20mm 2,5 m ORDERING DATA TYPE CEM-250 CODE. 2.0.4 ACCESSORIES KIT - PRE - WIRED FEMALE CONNECTOR CEM-256 CODE 80.43.82 - PUMP WATER PRESSURE TRANSMITTER TYPE TPA-200 NIPPLE F/4" GAS -M3/8 GAS CODE 50.02.5 CONFORMITY DECLARATION The company Elcos s.r.l. assumes full responsibility for declaring that the equipment: Type CEM-250 used in the ways and for the purposes described in the instruction and user manual is in conformity with the directive: - 89/336/CEE concerning electromagnetic compatibility, modified by the directive 93/68/CEE because it is built and functions in accordance with the harmonized: Standards EN 5008-, EN 50082-, EN 60529. S.r.l. Via Naviglio Alto, 24/a 4300 PARMA ITALIA Tel. +39 052/77202 Fax +39 052/27028 E-mail: info@elcos.it - HTTP://www.elcos.it Parma, 30/06/2005 President Walter Consigli 8 GB CEM-250