LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Similar documents
LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

Installation, Operation, and Maintenance Manual Series LFF113FP Wireless Smart Universal Flood Protection ACV System with SentryPlus Alert Technology

Deep Well Pump Control Valve

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

SOLENOID CONTROL VALVE

PRESSURE REDUCING CONTROL VALVES

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

Electronic Control Valves

DOROT CONTROL VALVES CATALOGUE

FLOAT CONTROL VALVES

MODULATING FLOAT CONTROL VALVE

Booster Pump Control Valve

BERMAD BERMAD BERMAD WW M

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

BERMAD Waterworks. Electronic Control Valve. 700 Series. Model Features and Benefits. Major Additional Features

Automatic Control Valves

Worldwide Contacts.

Colt Series C400, C500

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

700 LARGE SIZE SERIES

BERMAD Waterworks. BERMAD 700 Large Size Series. 700 Series. Features and Options. Model: 700-M5, 700-M6, 700-M5L

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

MODEL 106-PT / 106-PTC / S106-PT / S106-PTC DOUBLE CHAMBER HYDRAULICALLY OPERATED VALVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Flood Control Integrated System (FCIS)

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Booster Pump Control Valve

BERMAD Irrigation. IR-300 Basic Valve. 300 Series. ??????? Basic Valve

T e n c a n Backflo w Specialties

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Series 867 Reduced Pressure Zone Assemblies

CAST IRON VALVES PRESSURE REDUCING VALVES SERIES

Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

AVIATION FUELING CONTROL VALVES

PRESSURE RELIEF VALVE CONTROL VALVE

UPDATE LOG FOR TECHNICAL PROVISIONS DIVISION 4 Date Item(s) Changed Page # 10/1/13 TECHNICAL PROVISIONS DIVISION 4 VALVE SPECIFICATIONS

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Series 758 FireLock Actuated System Valve

Series 756 FireLock Dry System Check Valve

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

Technical Data. UL Listing is based on the following criteria:

HYDRAULIC CONTROL VALVES

BERMAD Irrigation. 300 Series. Basic Valve. ??????? IR-300 Basic Valve.

BERMAD Fire Protection

Automatic Control Valves. Providing quality, performance, dependability, and value for water control applications

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

TotalPac 3 Non interlock Preaction system Pneumatic release

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Series 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

TotalPac 3 Firecyle III Wet pipe Remote controlled system

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

BERMAD Waterworks. 800 Series. Technical Specifications Metric

TotalPac 3 Deluge, Electric release Remote controlled system

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Installation, Maintenance, & Repair Series 919 and LF919

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Instructions for Installation, Operation, Care and Maintenance

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

WATERWORKS. Reach Optimum Efficiency with OCV Control Valves.

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

Butterfly Valves. watts.com

GBV-G Balancing Valves

SECTION Pressure & Temperature Control

Model 788DVC DIGITAL CONTROL VALVES

MADE IN THE USA BACKFLOW PREVENTERS

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

North American Automatic Manual Reset and Motorized Valves

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

Suction Guide & Flo-Trex Valve Series

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

TotalPac 3 Deluge system Pneumatic release

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

The Ideal Solution for Protecting People and Property From the Ravages of Fire. SingerValve.com

Deluge Pressure Reducing Valves. Model 68 DE\ EL\ PORV\ PR. Electrically and Pneumatically Actuated, Pressure Reducing, Remote-Reset, Deluge Valve

Transcription:

Technical Bulletin TB-ACV-LFF11RFP LEAD FREE * LFF11RFP Flood Protection Shut Down Valve Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when continuous discharge from RPZ Relief Valve is sensed or by engaging Solenoid By-Pass. Valve must be manually reset. gauge (provided) indicates valve reset for automatic service. Position Indicator provides local visual indication of valve closure. Reverse Flow Main Valve closes in the event of diaphragm failure for fail-safe operation Specially coated Valve Stem for added protection. Heavy duty Cover Spring. JB11 provided Valve mounted. FS99 field installed. SB 4 2 X FC X P 5 1 6 JB11 To Floor Drain 7 FS99 8 Standard Components 1 - Main Valve (Single Chamber) 2 - Check Valve - Adjustable Closing Speed 4-2-Way Solenoid 5 - Gauge 6 - Manual Reset Ball Valve 7 - JB11 Junction Box 8 - FS99 Flow Sensor P - Position Indicator SB - Solenoid By-Pass X - Isolation Cocks FC - Flow Clean Strainer Options and Accessories { -LS (Single NEMA 4 Limit Switch) { -LS2 (Dual NEMA 4 Limit Switch) Materials Body & Cover: Coating: Trim: Elastomers: Stem, Nut & Spring FLOW CLOSES VALVE OPENS VALVE Ductile Iron ASTM A56 NSF Listed Fusion Bonded Epoxy Lined and Coated 16 Stainless Steel Buna-N (standard) EPDM Viton Stainless Steel NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Viton is a registered trademark of DuPont Dow Elastomers. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

100 80 60 40 20 psi AVOID FREEZING R 140 160 190 200 LFF11-RFP Installation Technical Bulletin - LFF11RFP Typical Installation * Junction Box Ships Valve Mounted Operation The Watts Flood Protection Shutdown Valve system prevents catastrophic property damage that can occur due to Relief Valve discharge and/or a blocked or overwhelmed floor drain during normal relief valve operation. Typical conditions which can cause continuous relief valve discharge are: Fouled First Check Seat due to dirt, debris or rocks Failed First Check Spring Clogged or blocked Relief Valve Sensing Line Relief Valve Diaphragm failure The Watts LFF11RFP Flood Protection Shutdown Valve is a normally open valve designed to be installed upstream of a Reduced Zone (RPZ) Backflow Prevention device. It is normally open and closes when continuous relief valve discharge through the drain pipe is sensed by the FS99 Flow Sensor, energizing the Solenoid Pilot. The valve is equipped with a Solenoid By-Pass valve (normally closed) which manually closes the Main Valve when engaged. The valve mounted JB11 Junction Box is equipped with an adjustable time delay to avoid valve closure due to intermittent or nuisance relief valve discharge. The Position Indicator provides local, visual indication of valve closure and is useful during valve start-up and troubleshooting. The valve remains closed and cannot re-open if flow stops or electrical service is interrupted, and must be manually reset after the RPZ is diagnosed and/or repaired. The valve comes complete with the valve mounted JB11 Junction Box with adjustable time delay, pre-wired Solenoid Valve, Manual Reset with Gauge, Position Indicator and FS99 Flow Sensor (field installed). NOTICE If the LFF11RFP unit is installed in any orientation other than horizontal (Cover Up) or extreme space constraints exist, consult customer service prior to ordering.

LFF11-RFP Dimensions Technical Bulletin - LFF11RFP Globe L Angle D M K H I J A B C E F G Operating Threaded = 400 psi 150 Flanged = 250 psi 00 Flanged = 400 psi Operating Temperature Buna-N: 160 F Maximum EPDM: 00 F Maximum Viton: 250 F Maximum Pilot System Solenoid Brass (NEMA 4 General Purpose 110-VAC) Tubing & Fittings Copper / Brass (Standard) Stainless Steel (Optional) Dimensions Valve Size Globe Thread Globe 150# Globe 00# Cover To Center Angle Thread Angle 150# Angle 00# Angle Thread Angle 150# Angle 00# Port Size NPT Port Size Port Size NPT NPT Shipping Weights* A B C D E F G H I J K L M in. in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. in. in. lbs. kgs. 11/4 71/4 184 1/2 89 1/4 8 17/8 48 1/4 1/2 1/8 15 7 11/2 71/4 184 81/2 216 1/2 89 1/4 8 4 102 17/8 48 4 102 1/4 1/2 1/8 15 7 2 9/8 28 9/8 28 10 254 415/16 125 4 102 4 102 41/4 108 4 102 4 102 41/4 108 1/2 1/2 1/4 5 16 21/2 11 279 11 279 7 178 51/2 140 51/2 140 51/16 148 4 102 4 102 45/16 110 1/2 1/2 /8 65 0 101/2 267 12 05 11/4 7 7 178 51/4 1 5/4 146 61/8 156 51/4 1 5/4 146 61/8 156 1/2 1/2 /8 95 4 4 15 81 155/8 97 85/8 219 6/4 171 71/8 181 6/4 171 71/8 181 1/2 1/2 /8 190 86 6 20 508 21 5 11/4 298 81/2 216 87/8 225 81/2 216 87/8 225 1/2 1/2 1/2 20 145 8 25/8 645 26/8 670 15/4 400 11 279 111/2 292 11 279 111/2 292 1/2 1 1/2 650 295 Valve Cover Chamber Capacity Valve Size - Inches 1 1/4 1 1/2 2 2 1/2 4 6 8 fl.oz. 4 4 4 10 10 22 70 U.S. Gal 1 1/4 Valve Travel Valve Size - Inches 1 1/4 1 1/2 2 2 1/2 4 6 8 Travel - Inches /8 /8 1/2 5/8 /4 1 1 1/2 2

Flow Data - ACV F100 (Globe) / F1100 (Angle) C V Suggested Valve Size - Inches 1 1/4 1 1/2 2 2 1/2 4 6 8 Maximum Continuous Flow Rate Gpm (Water) Maximum Intermittent Flow Rate Gpm (Water) Minimum Flow Rate Gpm (Water) Technical Bulletin - LFF11RFP 9 125 208 00 460 800 1800 100 115 158 260 70 570 1000 200 900 5 6 9 15 16 17 25 Factor GPM (Globe) 29 4 55 75 125 220 460 775 Factor GPM (Angle) 9 5 66 99 170 280 650 1100 Maximum continuous flow based on velocity of 20 ft. per second. Maximum intermittent flow based on velocity of 25 ft. per second. Minimum flow rates based on a 20-40 psi pressure drop. The C v Factor of a value is the flow rate in US GPM at 60 F that will cause a 1psi drop in pressure. C v factor can be used in the following equations to determine Flow (Q) and Drop ( P): Q (Flow) = C v P P ( Drop) = (Q/C v ) 2 The C v factors stated are based upon a fully open valve. Many factors should be considered in sizing control valves including inlet pressure, outlet pressure and flow rates. For sizing questions including cavitation analysis consult Watts with system details. Headloss Angle Globe 1-1/4 1-1/2 2 2-1/2 4 6 8 10 12 14 16 100 80 1-1/4 1-1/2 2 2-1/2 4 6 8 10 12 14 16 60 40 Drop (p.s.i.) 0 20 10 8 6 4 2 2 4 6 8 10 20 40 60 80 100 200 500 1000 2000 5000 10000 20000 100000 Flow Rate - Gallons per minute (Water) The C v Factor of a value is the flow rate in US GPM at 60 F that will cause a 1 psi drop in pressure. The factors stated are based upon a fully open valve. Cv factor can be used in the following equations to determine Flow (Q) and Drop ( P): Q (Flow) = C v P P ( Drop) = (Q/C V ) 2

LFF11-RFP Main Technical Valve Bulletin - LFF11RFP F100 Main Valve 1 2 4 6 7 8 9 8 5 10 11 Item Description Material 1 Pipe Plug Lead Free Brass 2 Cover ASTM A56 65-45-12 Epoxy Coated Ductile Iron Cover Bearing ASTM A276 04 Stainless Steel 4 Stud with Cover Nut and Washer ASTM A570 Gr. Zinc Plated Steel 5 Body ASTM A56 65-45-12 Epoxy Coated Ductile Iron 6 Spring ASTM A276 02 Stainless Steel 7 Stem Nut ASTM A276 04 Stainless Steel 8 Diaphragm Washer ASTM A56 65-45-12 Epoxy Coated Ductile Iron 9 Diaphragm* Buna-N (Nitrile) 10 Spacer ASTM A276 04 Stainless Steel 11 Quad Seal Retainer ASTM A56 65-45-12 Epoxy Coated Ductile Iron 12 Quad Seal* Buna-N (Nitrile) 1 O-Ring* Buna-N (Nitrile) 14 Quad Seal Plate ASTM A74 CF8M (16) Stainless Steel 15 Shaft / Stem ASTM A276 04 Stainless Steel - Xylan Coated 16 Seat Ring ASTM A74 CF8M (16) Stainless Steel 17 Seat Gasket* Buna-N (Nitrile) * Contained in Main Valve Repair Kit 12 1 14 15 16 17

Technical Bulletin - LFF11RFP Junction Box 6.00 Power Relay with Red LED Indicator 15 10 20 5 25 UP 0 0 SEC 1 2 4 5 6 8.00 1 2 4 5 6 L1 N 1 2 4 5 6 Incoming Power Flow Sensor Solenoid Valve Remote Trip 120V/1PH Probes Indication CERTIFIED ELECTRICIAN TO CONNECT MAIN POWER AND FS99 FLOW SENSOR TO JB11 JUNCTION BOX CERTIFIED ELECTRICIAN TO CONNECT MAIN POWER AND FS99 FLOW SENSOR TO JB11 JUNCTION BOX The valve mounted JB11 Junction Box is a lockable NEMA 4 enclosure equipped with an adjustable time delay, electrical relay and terminal strip. There are three /4 inch conduit connections. The valve solenoid is prewired. The valve is normally open and closes when continuous relief valve discharge through the drain pipe is sensed by the FS99 Flow Sensor. The valve mounted JB11 Junction Box is equipped with an adjustable time delay to avoid valve closure due to intermittent or nuisance relief valve discharge. The time delay is adjusable from 0-0 seconds. Adjusting the dial clockwise increases the time delay for valve closure. Adjusting the dial counterclockwise decreases the time delay for valve closure. Terminals 1 & 2: Connect to FS99 Flow Sensor Probes. Terminals & 4: Prewired to the solenoid. Terminals 5 & 6: Terminals 5 and 6 may be used for remote trip indication to an alarm or Building Management System. Installation Notes: Terminal block accepts 10-22 AWG Remote indication terminals 5 & 6 have a 120V, 10AMP maximum. Required voltage for JB114 Junction Box is 120V. Probe Voltage is 12VAC 1.5mA. Less than 1 amp draw.

LFF11-RFP FS-99 Technical Flow Sensor Bulletin - LFF11RFP Accessories Model 50 - Position Indicator The Model 50 Position Indicator is installed in the topmost cover port of the Main Valve and allows for visual indication of valve position. The Model 50 is also very useful during valve start-up and troubleshooting procedures. A stainless steel indicating rod threads into the tapped portion of the Main Valve stem and moves inside of a cylindrical Pyrex sight tube. The indicating rod travels up and down, following Main Valve stem movement. The housing protects the sight tube and indicating rod, and allows visibility on two sides. The screw driver operated test cock installed on the top of the Model 50 housing provides a controlled method of removal of air from the cover chamber during start-up or troubleshooting of the Main Valve. Front View Top View FS99 - Flow Sensor The FS99 Flow Sensor is field installed in the discharge piping from the RPZ Relief Valve. The FS99 senses water in the discharge piping signaling the JB11 Junction Box to close the valve. To Floor Drain Sensor Probes installed 1/4 inch above pipe bottom From RPZ Relief Valve (with Air Gap) NOTE TO INSTALLING CONTRACTOR Client/Contractor to provide installation Tee for Flow Sensor. Install Flow Sensor in RPZ discharge line in HORIZONTAL position as shown. Sensor Probes should be cut to length and installed 1/4 inch above pipe bottom. ENSURE SENSOR PROBES DO NOT CONTACT PIPE BOTTOM OR SIDES. CERTIFIED ELECTRICIAN TO CONNECT MAIN POWER AND FS99 FLOW SENSOR TO JB11 JUNCTION BOX

LFF11-RFP Accessories Technical Bulletin - LFF11RFP Accessories The Solenoid is prewired to the JB11 Junction Box and is equipped with a Solenoid By-Pass valve (normally closed) which manually closes the Main Valve when engaged. Opening the Solenoid By-Pass Valve (SB) pressurizes the Main Valve cover as indicated by Gauge (5), closing the Main Valve. Closing Solenoid By-Pass Valve and opening the Manual Reset Ball Valve (6) returns the Main Valve to the full open position. Gauge returns to zero when the Main Valve is fully open. Note: Manual Reset Ball Valve must be closed for normal operation. The valve pilot circuit is equipped with a Model 60 Flo-Clean Strainer which is used to filter the fluid passing through the control pilot circuit, and provide protection to pilot circuit speed controls and pilots. It is installed in the inlet body port of the main valve, exposing the strainer element to main line flow. The currents and flow across the screen create a self-scouring effect, cleaning the filter element. Valve Inlet The Main Valve is provided standard with a specially coated Main Valve Stem for stand-by service. The special coating helps deter the effects of hard water and mineral deposits which may prohibit proper valve operation. The Main Valve is also provided standard with a heavy cover spring to provide additional operating differential.

LFF11-RFP Start-up Technical Bulletin - LFF11RFP Start-Up Proper Automatic Control Valve start up requires bringing the valve into service in a controlled manner. All adjustments to control pilots and speed controls should be made slowly, allowing the valve to respond and the system to stabilize. NOTE: Control Valves should be set up in a dynamic (flowing) condition for proper start up. Provisions for flow must be made to insure proper settings. 1. Refer to valve schematic. Close Solenoid By-Pass Valve (SB). Locate and open Manual Reset Ball Valve (6). Open upstream and downstream isolation valves to allow controlled filling of the Valve and Backflow Assembly. Open all Isolation Ball Valves. 2. Inlet pressure will open the valve fully. Close Manual Reset Ball Valve.. Open Solenoid By-Pass Valve to simulate electrical shutdown signal. Inlet pressure will be indicated on Gauge (5) and valve will begin to close. Due to low / no flow condition, valve closure may be slower than normal operation. 4. Close Solenoid By-Pass Valve and open Manual Reset Ball Valve. Pilot System Gauge will drop to zero. Valve will open fully and is ready for electrical activation. Allow for cover volume to discharge to floor drain. Refer to chart on Page 2 for Cover Chamber Volume. Close Manual Reset Ball Valve. 5. Open JB11 Junction Box. Apply power and observe the Electric Relay Control. 6. Pour adequate amount of water into RPZ Relief Valve Air Gap until the RED LED indicator light on the Electrical Relay illuminates / flashes. This indicates the FS99 Flow Sensor is properly installed and is sensing water in the discharge piping. 7. Trap water in discharge piping and observe RED LED on Electrical Relay. Solenoid will energize when duration of Time Delay elapses. Valve will go closed and must be manually reset. Adjust Time Delay to Customer / Project specifications. To manually reset valve refer to Step 4. 8. For final test simulate actual RPZ Relief Valve discharge and observe floor drain for excessive pooling or flooding. Re-adjust time delay and Adjustable Closing Speed () control as needed to achieve desired valve closure time.

Technical Bulletin - LFF11RFP Specifications The Flood Protection Shutdown Valve shall be a normally open Diaphragm Valve installed upstream of the Reduced Zone Backflow Assembly, and automatically close if the RPZ relief valve begins to discharge. A Time Delay supplied in the JB11 Junction Box shall prevent the valve from closing on intermittent discharges from the RPZ relief valve. If continuous Relief Valve discharge occurs, the FS99 Flow Sensor installed horizontally in the RPZ Relief Valve discharge piping shall send a signal to the JB11 Junction Box energizing Solenoid to close the main valve. Once closed the Flood Protection Shutdown Valve must be manually reset. The JB11 Junction Box shall be valve mounted with the Solenoid pre-wired. The FS99 Flow Sensor shall be provided with the valve package and shall be field installed in a horizontal position in the RPZ Relief Valve discharge piping. Vertical installation of the Flow Sensor shall not be acceptable. The valve shall be equipped with a Position Indicator to provide local visual indication of valve closure. The Position Indicator shall be a stainless steel indicating rod which follows main valve stem movement as seen through a cylindrical Pyrex sight tube. The Reduced Zone Backflow Assembly, Flood Protection Shutdown Valve, JB11 Junction Box and FS99 Flow Sensor shall be provided by the same manufacturer and be covered by a single warranty policy. The main valve shall be a hydraulically operated, single diaphragm actuated, globe or angle pattern valve. Y-pattern valves shall not be permitted. The valve shall contain a disc and diaphragm assembly that forms a sealed chamber below the valve cover, separating operating pressure from line pressure. The diaphragm shall be constructed of nylon reinforced Buna-N, and shall not seal directly against the valve seat and shall be fully supported by the valve body and cover. Rolling diaphragm construction will not be allowed and there shall be no pistons operating the main valve or any pilot controls. The main valve body and cover shall be Ductile Iron ASTM A56, and all internal cast components shall be Ductile Iron or CF8M (16) Stainless Steel. All Ductile Iron components, including the body and cover, shall be lined and coated with an NSF 61 Certified Epoxy Coating applied by the electrostatic heat fusion process. All main valve throttling components (valve seat and disc guide) shall be Stainless Steel. The valve body and cover must be machined with a 60-degree locating lip to assure proper alignment. The disc and diaphragm assembly shall contain a Buna-N synthetic rubber disc with a rectangular cross-section that is securely retained on -1/2 sides by a disc retainer and disc guide. Diaphragm assemblies utilizing bolts or cap screws for component retention will not be permitted. Direction of flow through the valve shall be the under-thedisc design. The exposed portion of the seat disc shall contact the valve seat and seal drip-tight. The disc and diaphragm assembly must be guided by two separate bearings, one installed in the valve cover and one concentrically located within the valve seat, to avoid deflection and assure positive disc-to-seat contact. Center guided valves will not be permitted. The main valve spring shall be the manufacturer s heavy or extra heavy spring design. All necessary repairs shall be made from the top of the valve while the body remains in line. The Pilot Control System shall contain a Flo-Clean Strainer, NEMA 4, 120 VAC 60HZ 2-Way Solenoid with Manual Operator, Manual Reset Ball Valve, Gauge, Visual Position Indicator, JB11 Junction Box and Isolation Ball Valves on all body connections. The JB11 Junction Box shall be valve mounted and the FS99 Flow Sensor shall be field installed. The valve shall be Watts Model LFF11RFP (globe) or LFF111RFP (angle) Flood Protection Shutdown Valve.

Series 009, 909, 919, 957 and 994 Reduced Zone Assemblies Relief Valve Discharge Rates Technical Bulletin - LFF11RFP 152 40 1 5 114 0 95 25 76 20 57 15 8 10 19 5 1 4", 8", 1 2" 009QT 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 180 psi 0.7 1.4 2.0 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.7 10. 11.0 11.7 12.4 bar 4" 009MQT 266 70 228 60 152 40 114 0 76 20 8 10 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 180 psi 0.7 1.4 2.0 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.7 10. 11.0 11.7 12.4 bar 228 60 152 40 114 0 76 20 8 10 1" 009M2QT 0 10 20 0 40 50 60 70 80 90 100 psi 0 69 18 207 276 45 414 48 552 621 690 kpa Note: These curves represent catastrophic or worst case discharge rates. These curves were developed by pressurizing the outlet of the backflow preventer with the second check valve s internals removed from the body.

Technical Bulletin - LFF11RFP 1 1 4" 009M2QT 52 140 456 120 04 80 228 60 152 40 76 20 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 180 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.7 10. 11.0 11.7 12.4 bar 1 1 2" 009M2QT 51 5 456 120 99 105 42 90 285 75 228 60 171 45 114 0 57 15 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 180 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.7 10. 11.0 11.7 12.4 bar 2" 009M2QT 86 220 760 200 684 180 608 160 52 140 456 120 04 80 228 60 152 40 76 20 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.7 10. 11.0 11.7 bar Note: These curves represent catastrophic or worst case discharge rates. These curves were developed by pressurizing the outlet of the backflow preventer with the second check valve s internals removed from the body. 10 50 1140 00 950 250 760 200 570 150 2 1 2", " 009 0 10 20 0 40 50 60 70 80 90 100 110120 10 140 150 160 170 180 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.6 10. 11.0 11.7 12.4 bar

Technical Bulletin - LFF11RFP 570 150 475 125 285 75 95 25 4", 1" 909 1520 400 10 50 1140 00 950 250 760 200 570 150 1 1 4", 1 1 2", 2" 909 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 180 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.6 10.11.0 11.712.4 bar 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.6 10. bar 2090 550 1900 500 1710 450 1520 400 10 50 1140 00 950 250 760 200 570 150 420 900 040 800 2660 700 2 1 2" - " 909 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 180 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 8. 9.0 9.6 10. 11.0 11.7 12.4 bar 4", 6", 8", 10" 909 Note: These curves represent catastrophic or worst case discharge rates. These curves were developed by pressurizing the outlet of the backflow preventer with the second check valve s internals removed from the body. 2280 600 1900 500 1520 400 1140 00 760 200 0 5 15 25 5 45 55 65 75 85 95 105 115 125 15 145 psi 0. 1.0 1.7 2.4.1.8 4.5 5.5 5.9 6.5 7.2 7.9 8.6 9. 10 bar

228 60 152 40 114 0 76 20 8 10 1" 919 RV Capacity w/second Check Removed Technical Bulletin - LFF11RFP 0 10 20 0 40 50 60 70 80 90 100 110 120 10 140 150 160 170 180 psi 0.7 1.4 2.0 2.8.5 4.1 4.8 5.5 6.2 6.9 7.8 8. 9.0 9.7 10. 11.0 11.7 12.4 bar 684 180 170 6.8 160 570 150 52 140 10 456 120 110 42 90 04 80 266 70 228 60 152 40 114 0 76 20 8 10 2" 919 QT Backpressure w/second Check Poppet & Spring Removed 0 10 20 0 40 50 60 70 80 90 100 110 psi 0.7 1.4 2.1 2.8.5 4.1 4.8 5.5 6.2 6.9 7.6 psi 420 900 040 800 2660 700 2280 600 10 50 1140 00 950 250 760 200 570 150 500 1900 500 400 1520 400 00 1140 00 760 200 0 00 0 40 80 120 160 200 240 280 psi 2 1 2" 10" 957 0 20 40 60 80 psi 0 18 276 414 552 kpa 2 1 2" 10" 994 0 276 552 827 110 179 1655 191 kpa Typical Flow Rates as sized by floor drain manufacturers gpm Note: These curves represent catastrophic or worst case discharge rates. These curves were developed by pressurizing the outlet of the backflow preventer with the second check valve s internals removed from the body. lpm Drain Size 55 209 2 112 426 170 646 4 50 10 5 TB-ACV-LFF11RFP 1725 USA: T: (978) 689-6066 F: (978) 975-850 Watts.com Canada: T: (905) 2-4090 F: (905) 2-7068 Watts.ca Latin America: T: (52) 81-1001-8600 Watts.com 2017 Watts