PVC Quick Drain Valve

Similar documents
Space saving, compact model available

High Purity Chemical Valve Compact Type. Space saving, compact type is available. Piping from 4 directions are possible.

Technical information for LFU20-Z07-3A-X2

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Series VVXA21/22. Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil VC VDW VQ VX2 VX VX3 VXA VN LVC LVA LVH LVD LVQ LQ LVN PA PAX

Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil

Two Hand Control Valve

Series AV2000/3000/4000/5000

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Speed Controller with One-touch Fitting

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

How to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

2 Port Solenoid Valve For Dust Collector

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

Speed Controller with One-touch Fitting

Integral Fitting Type (Hyper Fittings) How to Order Valves (Single Type) Material. Symbol N PFA F PFA

Rotary Actuators Precautions 1 Be sure to read this before handling.

High Purity Chemical Valve

Valve for Water and Chemical Base Fluids

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

For Pneumatic Piping/Fittings & Tubing Prior to Use

Precision Clean Regulator

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Compact Proportional Solenoid Valve

Pressure Relief 3 Port Valve With Locking Holes

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Low Torque Rotary Joint

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Low Torque Rotary Joint

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Digital Flow Switch for Deionized Water and Chemicals

Speed Controller with Indicator

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 ASP330F-N01 ASP430F-N02 ASP530F-N03 ASP630F-N04

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

MMD. Chemical liquid manual valve/toggle valve/flow control valve. Overview. Features FMD00

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

AFM20-A AFD20-A. (ANR) ( 0.8 ppm) MAX 0.1 mg/m 3 (ANR) (Before saturated with oil 0.01 mg/m 3 Note 2) Note 3) Semi-standard (Steel) 0.

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Exclusively for air pressure system and air-hydro circuit control

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Pressure sensor with built-in amplification and temperature compensation circuit

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Coolant valve. SGC/SGH Series

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

VCHR Series. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Power Valve Precision Regulator

High Pressure Coolant Valve

ACTIVAL Two-way Ball Valve with Threaded-end Connection

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

CVE2/CVSE2 CVE3/CVSE3

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Miniature Regulator Series ARJ310

Specifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard

Series LVQ. Constructed without screws. Air Operated Chemical Valve Non-Metallic Exterior. Space Saving Type

2/3 Port Valve for Various Fluids Control

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Regulator Valve. VEX1 Series

Vacuum pump system type

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Transmitters: Relay Valve

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Transmitters: Relay Valve VR4151/4152

2-Color Display Digital Pressure Switch

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Push-In Fitting Type Quick Exhaust Valve

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Series CYP. ø15, ø32 Clean Rodless Cylinder. How to Order

Motorized Two-Way Ball Valve with Screwed-End Connection

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Guide Table. MGF Series

25% reduction in volume * PB1013A/Air-operated type without foot

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Multi-Circuit Rotary Block

Installation and Maintenance Manual VXZ Zero Pressure Differential Type Pilot Operated 2 Port Solenoid Valve

Miniature Fittings Stainless Steel 316. Hose nipple. Barb Configuration for easy insertion into the tube Holds the tube tightly.

Series AN /Series AMC

High-speed detection even a little liquid leak

Transcription:

PVC Quick Drain Valve LVW Series Complies to JIS standard for polyvinyl chloride piping (JIS K 6742) Applicable fluids: Deionized water, Chemical liquids Application Example Cleaning Equipment Process pump Digital flow switch LVC LVA LVH LVD LVQ LVP LVW LQ1 LQ3 LVN LQHB TL TIL TLM TILM TD TID TH TIH Air operated valve Quick Drain Valve Fluid contact materials Body PVC Poppet PTFE (Standard) (Optional) Orifice size ø25, ø40, ø65, ø80 low-rate characteristics Cv factor: 10 to 198 Easy piping with union connection Applicable PVC piping external diameter ø32 to ø89 851

PVC Quick Drain Valve LVW Series How to Order LVW 60 25A Symbol PA B A PB Symbol 60 80 90 Body class 6 8 9 Series Orifice size ø25 ø40 ø65 ø80 Port size Symbol Applicable PVC piping external diameter Body class 25A ø32 6 32A ø38 40A ø48 8 50A ø60 65A ø75 9 80A ø89 material Symbol Material Nil N Pilot port thread type Symbol Thread type Nil Rc1/8 N NPT1/8 Standard Specifications Model Nominal diameter Applicable pipe size external diameter Operating pressure Orifice size Pilot pressure Kv Flow rate characteristics Cv Fluid temperature Valve leakage LVW60 25A ø32 ø25 8.5 10 LVW80 32A ø38 40A ø48 50A ø60 0 to 0.02 MPa ø40 ø65 0.3 to 0.5 MPa 18.8 22 43.7 51 71.1 83 0 to 60 C 0 cm 3 /min (with water pressure) LVW90 65A ø75 131.1 153 80A ø89 ø80 169.7 198 852

PVC Quick Drain Valve LVW Series Construction IN r t y LVC LVA e LVH u i o!0 Component Parts No. Description Material Optional 1 Body PVC LVD LVQ LVP q w 2 3 4 5 Housing Poppet Union end Union nut PVC PTFE PVC PVC LVW LQ1 6 7 LQ3 8 9 LVN OUT 10 LQHB TL TIL Dimensions TLM TILM TD TID TH TIH ød3 ød2 ød1 IN L1 2 x Rc1/8 (NPT1/8) Pilot port L2 PA PB L4 OUT L1 L3 Dimensions Part no. L1 L2 L3 L4 D1 D2 (mm) D3 LVW60-25A LVW80-32A LVW80-40A LVW90-50A LVW90-65A LVW90-80A 22 26 31 39 44 51 81.5 94 101 136.5 138.5 143.5 14.5 20.5 20.5 26 26 33 172 205 220 275 279 304 32 38 48 60 75 89 60 72 83 100 135 158 70 90 90 120 120 140 853

LVW Series Applicable Fluids PVC Quick Drain Valve Material and Fluid Compatibility Check List Ammonium hydroxide Isobutyl alcohol Isopropyl alcohol Hydrochloric acid Hydrogen peroxide Chemical Temperature 40 C or less Temperature 40 C or less Temperature 40 C or less Concentration 30% or less Concentration 5% or less, Temperature 50 C or less Compatibility Material option N Note 2) Note 1), 2) Note 1), 2) Note 2) Nitric acid (except fuming nitric acid) Deionized water Sodium hydroxide (Caustic soda) Nitrogen gas Ultrapure water Concentration 10% or less, Temperature 40 C or less Concentration 50% or less Note 2) Sulfuric acid (except fuming sulfuric acid) Concentration 30% or less Note 2) Phosphoric acid Concentration 50% or less The material and fluid compatibility check list provides reference values as a guide only. Note 1) Since static electricity may be generated, implement suitable countermeasures. Note 2) Fluid may pass through. Fluid that has passed through may have an impact on components made of different materials. Compatibility is indicated for fluid temperatures of 60 C or less. The material and fluid compatibility check list provides reference values as a guide only, therefore we do not guarantee the application to our product. The data above is based on the information presented by the material manufacturers. SMC is not responsible for its accuracy and any damage happened because of this data. Table symbol : Can be used : Can be used under certain conditions 854

LVW Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions. Design/Selection 1. Check the specifications. Give careful consideration to operating conditions such as the application, fluid and environment, and use within the operating ranges specified in this catalog. 2. Fluids Operate after confirming the compatibility of the product's component materials with fluids, using the check list on page 854. Please contact SMC regarding fluids other than those in the check list. Operate within the indicated fluid temperature range. 3. Maintenance space Ensure the necessary space for maintenance and inspections. 4. Fluid pressure range Keep the supplied fluid pressure within the operating pressure range specified in this catalog. 5. Ambient environment Install the product in an environment where there is no effect from radiant heat caused by heat sources, etc., and use within the ambient operating temperature range. After confirming the compatibility of the product's component materials with the ambient environment, operate so that fluid does not adhere to the product's exterior surfaces. 6. Liquid seals When circulating fluid Provide a relief valve in the system so that fluid does not get into the liquid seal circuit. 7. Countermeasures for static electricity Since static electricity may be generated depending on the fluid being used, implement suitable countermeasures. Mounting 1. If air leakage increases or equipment does not operate properly, stop operation. After mounting, perform suitable function and leak tests to confirm that the mounting is correct. 2. Operation manual Mount and operate the product after reading the manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary. Piping 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. Install piping so that it does not apply pulling, pressing, bending or other forces on the valve body. 2. Use the tightening torques shown below for the pilot port. Tightening Torque of Pilot Port Pilot port Torque (N m) Rc, NPT1/8 0.8 to 1.0 3. Use of metal fittings In the case of threaded pilot port, do not pipe the metal fittings which can cause damage to the thread part. 4. Tighten the union nuts on both sides equally by hand. A watertight seal can be obtained by hand tightening. Never use a pipe wrench etc., as it may break the product. Table 1 shows the tightening torque for reference. Table 1 Tightening Torque of Union Nut Nominal dia. mm (inch) Tightening torque N m 25 (1) 4.0 32 (1 1 /4) 6.0 40 (1 1 /2) 8.0 5. When applying adhesive to the union end or union bushing, the seals can be damaged by the adhesive running into the seals. Always remove the union end and union nut from the body when applying adhesive. 6. In places where vibration could be applied to the union, take countermeasures to prevent vibration. 7. Do not tighten the union while there is pressure left in the piping. Pilot Air Supply 50 (2) 12.0 For fittings of 65A or larger, tighten the fittings by a further 1/8 rotation (45 ) with a belt wrench after tightening by hand. However, do not use metal tools. 1. Use clean air. Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt, or corrosive gases, etc., as this may cause damage or malfunction. LVC LVA LVH LVD LVQ LVP LVW LQ1 LQ3 LVN LQHB TL TIL TLM TILM TD TID TH TIH 855

LVW Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions. Operating Environment 1. Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiation heat. 4. Do not use in environments which exceed the ambient temperature specifications of the product. Operating Precautions 1. Operate within the ranges of the maximum operating pressure. 1. Fluorine grease is used on the sliding part of the piston, so the grease is in contact with the fluid. PVC Piping 1. PVC fitting (union) The PVC fitting (union) must be mounted and joined by an engineer with sufficient knowledge. Be sure to confirm that there is no leakage from the fitting after mounting and joining. If it is mounted and joined by a person who does not have sufficient knowledge and skills, it may lead to failure such as leakage. 2. When selecting adhesive for the PVC fitting (union), confirm that its heat resistance and endurance are compatible with the operating temperature of the fluids used. Otherwise, this may cause leakage and damage. 3. Do not apply excessive force to the PVC piping. This may cause damage. 4. When the PVC piping type is used, the higher the fluid temperature, the lower the proof pressure will be. Therefore, adjust the water hammer pressure carefully so that it does not exceed the proof pressure. Maintenance 1. Maintenance should be performed in accordance with the procedures in the operation manual. Incorrect handling can cause damage or malfunction of machinery and equipment, etc. 2. Before removing equipment or compressed air supply/exhaust devices, shut off the air and power supplies, and exhaust compressed air from the system. Further, when restarting equipment after remounting or replacement, first confirm safety and then check the equipment for normal operation. 3. Perform work after removing residual chemicals and carefully replacing them with deionized water or air, etc. 4. Do not disassemble the product. Products which have been disassembled cannot be guaranteed. If disassembly is necessary, please contact SMC. 5. In order to obtain optimum performance from valves, perform periodic inspections to confirm that there is no leakage from valves or fittings, etc. 1. Removal of drainage Flush drainage from filters regularly. 856