Fluid Coolers Forced Draft

Similar documents
Fluid Coolers Induced Draft

Crossflow Cooling Towers

PRODUCT CATALOGUE 2013 AUSTRALIAN MADE

EC-S SERIES COOLING TOWER. High Performance Counterflow Type SINGLE-CELL UP TO 1250HRT COOLING CAPACITY

SERIES COOLING TOWER SINGLE-CELL UP TO 1700HRT COOLING CAPACITY

SERIES COOLING TOWER SINGLE-CELL UP TO 1500HRT COOLING CAPACITY

SERIES COOLING TOWER SINGLE-CELL UP TO 1500HRT COOLING CAPACITY

SERIES COOLING TOWER. MULTI-CELL HRT COOLING CAPACITY Modular Design Crossflow Type LOW NOISE SUPER LOW NOISE ENERGY SAVING SUPER LOW NOISE

PROVEN PERFORMANCE RELIABILITY EASY INSTALLATION

GPC SERIES CROSSFLOW FRP COOLING TOWER

SERIES COOLING TOWER. High Performance Counterflow Type SINGLE-CELL UP TO 1500HRT COOLING CAPACITY ENERGY CONSERVATION SPACE SAVING DESIGN FLEXIBILITY

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

VXI Closed circuit cooling towers

All-Fiberglass. Cooling Towers. The. HFC Series. High Performance & Quality with Maximum Durability CLOSED CIRCUIT FLUID COOLER

cutting edge technology at work LAKESIDE COOLING TOWERS (AUSTRALASIA) PTY LTD ABN ESTABLISHED 1958

GD/GDS SERIES COUNTERFLOW COOLING TOWER MEMBER

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

\*"N \\N* J~~ nn11u w"r;r,!nu l ~~~~1 ~ /00'' l l/ l wiruirmu. II~IIt1r111111nNu~.;,, ~~;;* : ~.. f I ~ ~ + ~~ rrrrrrtrrrrrtitr "'n~~~.

FXV/CXV & FXV3/CXV3 Layout Guidelines

TVFC Dry and adiabatic cooling

Industrial Mini Vent Sets

Design of Integrated System

Kirby WRC Remote Condenser. With HyBlade EC Fans and AxiTop Diffuser

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Counter Flow Cooling Towers

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Sabre Plate Mounted Sickle Fans (VSP)

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

A Smarter Breed. of Centrifugal Fans

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

Recold JW Series. Lenntech. Tel Fax ENGINEERING DATA AND SPECIFICATIONS

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

technical catalogue tetris KW Chiller and heat pumps air/water

Prepared By : Checked By : Approved By : Page 1 out of 6

SECTION AXIAL HVAC FANS

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

CGA CXA VGA VXA CG-PRC006-E4

MAJAX-2 GENERAL SPECIFICATION

Engineering Brochure. T-Model Cooling Towers A Manufacturer for 42 Years MEMBER

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

Transformer Oil Cooling Solutions

30GX AIR-COOLED LIQUID CHILLER

Air-Cooled Condensers - Axial Fan

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

FRP Fans: CLUB Series Performance and Technical Information

Engineering Brochure. T-Model Cooling Towers A Manufacturer for 40 Years! The MEMBER

NH 3. Evaporator. Ammonia Applications Tons MANP

30GX AIR-COOLED LIQUID CHILLER

Plate mounted axial flow fans HXBR / HXTR Series

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Air-Cooled Liquid Chiller with integrated hydraulic module

Küba SG industrial

Laboratory Exhaust Systems

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

PHR5. Product Specifications

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Bottle type configuration on counterflow design maximizes heat-exchanging efficiency, while minimizes acquisition cost as well as installation cost.

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

IDCF Evaporative Condensers

TOP 10 NOISE CONTROL TECHNIQUES

PEDESTAL PLUG FANS FPP SERIES, HIGH EFFICIENCY CATALOGUE

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

SECTION CENTRIFUGAL HVAC FANS

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

Ocelot vertical fan coil unit

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Engineering Data. Series V Closed Circuit Cooling Towers. VFL Engineering Data...1. VF1 Engineering Data...3

RELN Septic & Holding Tanks

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Belt Conveyors Conveyors - Pallet Handling - Special Purpose Machinery

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

Characteristics. Structure and Standard Materials

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

DAEIL AQUA CO., LTD.

Atlas Copco Oil-injected Rotary Screw Compressors. G kw / hp

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

HYDROVANE ROTARY VANE COMPRESSOR WITH REGULATED SPEED - THE 'RS' RANGE (7kW - 75kW)

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

SECTION WELDING FUME EXHAUST SYSTEM

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

The World Leading Air-conditioning Company

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Landmark Rooftop Packaged Units

Transcription:

Fluid Coolers Forced Draft PRODUCT CATALOGUE 2013 AUSTRALIAN MADE

2 www.fct.net.au Disclaimer The information or advice contained in this catalogue is intended for use only by persons who have had adequate technical training in the field to which the catalogue relates. The information in this catalogue is a guide only and not to be used for construction. The user should also establish the applicability of the information or advice in relation to any specific circumstances. While the information or advice is believed to be correct the employees and agents disclaim responsibility for any inaccuracies contained within the document including those due to any negligence in the preparation and publication of the catalogue.

www.fct.net.au 3 Contents Disclaimer Contents Nomenclature Company Profile Fluid Coolers Forced Draft Components Engineering Design Layout Access and Maintenance Sound Levels Lifting Techniques Plinth Arrangements Variable Speed Drives Freight Site Assembly Compliance with the Standards Modular Design Notes Quick Selection Data Features Engineering Data Line Drawing 2 3 4 5 6 7 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25

4 www.fct.net.au Nomenclature (Model Number Legend) 1 2 3 4 5 ctcf f 215 a ln 1. Open Cooling Towers CTCF - Cooling Tower Counter Flow CTDF - Cooling Tower Dual Flow CFSF - Cooling Tower Single Flow CTFD - Cooling Tower Forced Draft Evaporative Condensers ECCF - Evaporative Condenser Counter Flow ECFD - Evaporative Condenser Forced Draft Industrial Fluid Coolers IFCCF - Industrial Fluid Cooler Counter Flow IFCFD - Industrial Fluid Cooler Forced Draft 2. Material of Construction F - Fibreglass M - Metal Mild Steel SS - Stainless Steel 3. Cooling Towers Kilowatts Total Heat Rejection with conditions 35/ 29.5/ 24 Deg. Celcius divided by 10 Evaporative Condensers Kilowatts Total Heat Rejection with conditions 40.5 Deg. Celcius, Condensing @ 24 Deg. Celcius Wet Bulb divided by 10. For R22 and R134A Industrial Fluid Coolers Kilowatts Total Heat Rejection with conditions 35/ 29.5/ 24 Deg. Celcius divided by 10 4. 5. Series Fan Type S - Standard LN - Low Noise

www.fct.net.au 5 AUSTRALIAN MADE FIBREFLOW COOLING TOWERS Company Profile Fibreflow Cooling Towers is wholly Australian owned and made. Fibreflow Cooling Towers was established in response to the demand for a quality HVAC manufacturer in Australia and develop and design composite products to related manufacturing methods. Various production methods include cold pressing heavy section FRP mouldings and forming hollow and complex one piece FRP sections. Our production methods use the best isophthalic, vinyl ester resins, gelcoats and high quality reinforcements. Our products are developed to stand the test of time with the quality, lifecycle and performance that goes above and beyond the expectations of our customers. With a combined experience of over 50 years in the industry, we have formed an insight as to what is required of our products, thus meeting the market with the best solutions for the application. Typical applications include cooling tower structures and components, support assemblies, motor mounts and bearing housing mounts in a variety of materials to suit the clients requirements. Our range of FRP Process Cooling equipment are developed and manufactured right here in Australia. With benefits ranging from the low cost of ownership to long service life, high quality materials and virtually no maintenance, we can provide a tailored solution for your application.

6 www.fct.net.au Fluid COOLERS Forced Draft

www.fct.net.au 7 Fluid Coolers Quick Selection - Forced Draft - IFCFD Model DEG C hot water 35 35 35 35 35 35 35 35 35 35 35 37 cold water 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 32 wet bulb BOX SIZE 20 21 22 23 24 24.5 25 25.5 26 26.5 28 27 model: ifcfd WATER FLOW - LITRES PER SECOND 035 3 x 3 2.1 1.9 1.8 1.7 1.5 1.3 1.2 1.1 1.0 0.9 0.8 1.8 041 3 x 3 2.5 2.3 2.1 2.0 1.8 1.6 1.5 1.3 1.2 1.0 1.1 2.1 053 3 x 3 3.3 3.0 2.9 2.7 2.3 2.1 2.0 1.7 1.6 1.4 1.5 2.9 053 3 x 3 3.3 3.0 2.9 2.7 2.3 2.1 2.0 1.7 1.6 1.4 1.5 2.9 063 4 x 4 3.9 3.6 3.3 3.1 2.8 2.4 2.3 2.0 1.9 1.6 1.7 3.3 080 4 x 4 4.8 4.4 4.1 3.9 3.5 3.1 3.0 2.6 2.3 2.1 2.2 4.1 094 4 x 4 5.6 5.2 4.8 4.6 4.1 3.7 3.5 3.1 2.8 2.6 2.7 4.8 123 4 x 4 7.0 6.6 6.2 6.0 5.3 4.8 4.6 4.0 3.7 3.4 3.6 6.2 121 4 x 6 7.4 6.8 6.3 6.0 5.2 4.6 4.4 3.8 3.4 3.1 3.3 6.3 143 4 x 6 8.6 7.8 7.4 7.0 6.2 5.6 5.3 4.7 4.2 3.9 4.0 7.4 180 4 x 6 10.2 9.8 9.2 8.8 7.8 6.8 6.7 5.9 5.3 4.9 5.1 9.2 225 4 x 6 12.8 12.2 11.4 11.0 9.8 8.6 8.3 7.3 6.7 6.1 6.3 11.4 181 4 x 9 11.1 10.1 9.5 9.1 7.9 6.9 6.7 5.7 5.1 4.7 4.9 9.5 215 4 x 9 12.9 11.7 11.1 10.5 9.3 8.4 8.0 7.1 6.3 5.9 6.0 11.1 270 4 x 9 15.3 14.7 13.7 13.2 11.7 10.3 10.0 8.8 8.0 7.3 7.6 13.7 338 4 x 9 19.2 18.3 17.2 16.5 14.7 12.8 12.5 11.0 10.0 9.2 9.5 17.2 246 4 x 12 15.0 13.7 12.8 12.2 10.7 9.4 8.9 7.8 6.9 6.3 6.6 12.8 295 4 x 12 18.0 16.4 15.3 14.6 12.8 11.3 10.7 9.3 8.3 7.6 7.9 15.3 345 4 x 12 21.0 19.3 18.0 17.1 15.0 13.4 12.8 10.6 10.1 9.4 9.8 18.0 345 6 x 12 21.7 19.6 18.2 17.3 15.0 13.2 12.5 10.7 9.6 8.7 9.1 18.2 474 6 x 12 28.7 26.4 24.7 23.5 20.6 18.3 17.4 15.2 13.7 12.6 13.1 24.7 567 6 x 12 34.0 31.3 29.3 27.9 24.6 22.1 21.2 18.6 16.7 15.3 15.9 29.3 461 8 x 12 28.9 26.1 24.3 23.1 20.0 17.6 16.7 14.3 12.8 11.6 12.1 24.3 633 8 x 12 38.3 35.2 32.9 31.3 27.5 24.4 23.2 20.3 18.3 16.8 17.5 32.9 755 8 x 12 45.3 41.7 39.1 37.2 32.8 29.5 28.3 24.8 22.3 20.4 21.2 39.1 677 8 x 18 42.4 38.3 35.7 33.8 29.4 25.9 24.5 21.0 18.7 17.2 17.8 35.7 928 8 x 18 56.2 51.6 48.2 46.0 40.3 35.9 34.2 29.8 27.0 24.8 25.8 48.2 1159 8 x 18 70.2 64.6 60.3 57.5 50.3 44.8 42.8 37.2 33.7 31.0 32.2 60.3 596 10 x 12 36.7 33.4 31.1 29.6 25.9 23.0 21.9 19.0 17.0 15.6 16.2 31.1 728 10 x 12 43.6 39.8 37.3 35.7 31.6 28.3 27.0 23.6 21.2 19.4 20.2 37.3 792 10 x 12 46.7 42.9 40.3 38.6 34.4 30.9 29.6 25.9 23.3 21.4 22.2 40.3 NOTE: Do not use for construction. Refer to your sales representative for certified weights & dimensions. Data subject to change for product improvement.

8 www.fct.net.au Fluid Coolers Quick Selection - Induced Draft - IFCFD Model DEG C hot water 35 35 35 35 35 35 35 35 35 35 35 37 cold water 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 32 wet bulb BOX SIZE 20 21 22 23 24 24.5 25 25.5 26 26.5 28 27 model: ifcfd WATER FLOW - LITRES PER SECOND 981 10 x 18 59.8 54.9 54.2 48.7 42.6 38.2 36.5 31.9 29.7 26.5 27.4 54.2 1271 10 x 18 72.3 66.2 62.9 60.7 55.2 50.1 47.5 42.6 38.5 35.6 36.9 62.9 1409 10 x 18 83.3 74.1 70.2 67.6 61.2 55.5 53.2 47.2 43.0 39.9 41.3 70.2 691 12 x 12 43.3 39.1 36.4 34.5 30.0 26.4 25.0 21.4 19.1 17.5 18.2 36.4 946 12 x 12 57.3 52.7 49.2 46.9 41.1 36.6 34.9 30.4 27.5 25.3 26.3 49.2 1183 12 x 12 71.6 65.9 61.5 58.6 51.4 45.8 43.6 38.0 34.4 31.6 32.9 61.5 1177 12 x 18 79.5 73.2 68.3 65.0 56.8 51.1 48.8 42.8 38.4 35.4 36.6 68.3 1525 12 x 18 89.0 83.3 78.4 75.1 66.9 60.4 57.9 53.1 46.2 42.3 44.2 78.4 1691 12 x 18 98.5 92.1 86.5 81.2 75.0 68.5 62.1 57.3 53.2 48.3 50.5 87.5 NOTE: Do not use for construction. Refer to your sales representative for certified weights & dimensions. Data subject to change for product improvement.

www.fct.net.au 9 Fluid Coolers NOTE: Do not use for construction. Refer to your sales representative for certified weights & dimensions. Data subject to change for product improvement.

10 www.fct.net.au Fluid Coolers Fluid Coolers Forced Draft 1 Motor and Drives a) High Efficiency MEPS 2 Standard IP66 TEF b) Power Band Drive System c) Cast Iron or Aluminium Pulleys SPB Minimum d) Heavy Duty Bearings 2 Fan a) High Efficiency b) Low Noise c) Aluminium/GRP/FRP Construction d) Anti Corrosive 3 Spray System a) High Pressure PVC Pipe b) ABS Anti Clog Distribution Nozzles 4 Casing a) Stainless Steel or Fibreglass b) Isophthalic polyesther based resins & gelcoats c) UV Resistant Flow Coat d) High Quality Chemical and Corrosion resistant e) High Strength 5 Access Door a) High Strength b) Lightweight Fibreglass c) Easily Removable 6 Hardware 7 Coil a) 304 Stainless Steel Minimum a) High Quality Copper/ Steel b) Stainless Steel Frame c) Copper Heavy Duty Thick Wall Pipe Mounted in PTFE Tube Place with Stainless Steel Frame d) Pressure tested to 3000 KPA 8 Eliminators a) Easy to Maintain b) Fire Resistant c) Easily Removable NOTE: Do not use for construction. Refer to your sales representative for certified weights & dimensions. Data subject to change for product improvement.

www.fct.net.au 11 Fluid Coolers Fluid Coolers Forced Draft 8 5 6 3 4 7 2 1 NOTE: Do not use for construction. Refer to your sales representative for certified weights & dimensions. Data subject to change for product improvement.

12 www.fct.net.au Fluid Coolers Engineering Data - Forced Draft - IFCFD Model STEEL COIL COPPER COIL Model BOX SIZE Length L Width W Height h Motor Size Full Load CURRENT Air flow PUMP MOTOR PUMP FLOW Shipping Weight OPERATING Weight Shipping Weight OPERATING Weight IFCfd mm mm mm kw Amps L /sec KW L/S @ 3.65M kg kg kg kg 035 3 x 3 1150 1150 2100 2.2 4.8 3.9 0.75 7.2 790 1350 514 878 041 3 x 3 1150 1150 2300 3 6.5 4.2 0.75 7.2 880 1520 572 988 053 3 x 3 1150 1150 2500 4 8.4 4.5 0.75 7.2 950 1790 618 1164 053 3 x 3 1150 1150 2700 5.5 11 4.9 0.75 7.2 1120 1820 728 1183 063 4 x 4 1450 1350 2100 2.2 4.8 4.8 0.75 8.2 890 1460 579 949 080 4 x 4 1450 1350 2300 3 6.5 5.0 0.75 8.2 980 1650 637 1073 094 4 x 4 1450 1350 2500 4 8.4 5.1 0.75 8.2 1050 1890 683 1229 123 4 x 4 1450 1350 2700 5.5 11 5.8 0.75 8.2 1260 1990 819 1294 121 4 x 6 1900 1350 2100 3 6.5 5.8 1.1 9.3 1050 1600 683 1040 143 4 x 6 1900 1350 2300 4 8.4 5.9 1.1 9.3 1320 1850 858 1203 180 4 x 6 1900 1350 2500 5.5 11 5.7 1.1 9.3 1410 2010 917 1307 225 4 x 6 1900 1350 2700 7.5 14.9 6.1 1.1 9.3 1680 2310 1092 1502 181 4 x 9 2700 1350 2100 5.5 11 8.9 1.5 12.1 1650 2345 1073 1524 215 4 x 9 2700 1350 2300 7.5 14.9 9.5 1.5 12.1 1850 2650 1203 1723 270 4 x 9 2700 1350 2500 11 21.3 9.1 1.5 12.1 2050 2950 1333 1918 338 4 x 9 2700 1350 2700 11 21.3 9.8 1.5 12.1 2250 3360 1463 2184 246 4 x 12 3700 1350 2100 5.5 11 12.3 1.5 15.9 2050 3200 1333 2080 295 4 x 12 3700 1350 2300 7.5 14.9 12.9 1.5 15.9 2350 3450 1528 2243 345 4 x 12 3700 1350 2500 11 21.3 13.2 1.5 15.9 2650 3990 1723 2594 345 6 x 12 3800 1700 3200 11 21.3 18.5 3 21.9 3750 5350 2438 3478 474 6 x 12 3800 1700 3400 15 28.4 18.9 3 21.9 4250 5950 2763 3868 567 6 x 12 3800 1700 3600 15 28.4 19.5 3 21.9 4770 6680 3101 4342 461 8 x 12 3800 2500 3400 18.5 35 26.3 4 37.5 5950 7650 3868 4973 633 8 x 12 3800 2500 3600 22 40 27.8 4 37.5 6690 9120 4349 5928 755 8 x 12 3800 2500 3950 30 57 29.5 4 37.5 7520 11250 4888 7313 677 8 x 18 5600 2500 3400 30 57 38.9 5.5 54.3 8350 12650 5428 8223 928 8 x 18 5600 2500 3600 37 67 39.9 5.5 54.3 9560 15410 6214 10017 1159 8 x 18 5600 2500 3950 37 67 41.2 5.5 54.3 10980 16520 7137 10738 596 10 x 12 3800 3100 4100 30 57 36.2 4 44.2 7450 12500 4843 8125 728 10 x 12 3800 3100 4300 30 57 37.1 4 44.2 8320 13500 5408 8775 792 10 x 12 3800 3100 4500 37 67 38.9 4 44.2 9450 14500 6143 9425 NOTE: Do not use for construction. Refer to your sales representative for certified weights & dimensions. Data subject to change for product improvement.

www.fct.net.au 13 FLUID Coolers Engineering Data - Forced Draft - IFCFD Model STEEL COIL COPPER COIL Model BOX SIZE Length L Width W Height h Motor Size Full Load CURRENT Air flow PUMP MOTOR PUMP FLOW Shipping Weight OPERATING Weight Shipping Weight OPERATING Weight IFCfd mm mm mm kw Amps L /sec KW L/S @ 3.65M kg kg kg kg 981 10 x 18 5750 3300 4100 (2) 18.5 35 55.6 (2) 3 66.2 11980 17100 7787 11115 1271 10 x 18 5750 3300 4300 (2) 22 40 56.2 (2) 3 66.2 13520 18900 8788 12285 1409 10 x 18 5750 3300 4500 (2) 22 40 53.2 (2) 3 66.2 14530 21500 9445 13975 691 12 x 12 5750 3900 4100 30 57 55.6 4 52.3 8940 15000 5811 9750 946 12 x 12 5750 3900 4300 30 57 56.2 4 52.3 9984 16200 6490 10530 1183 12 x 12 5750 3900 4500 37 67 53.2 4 52.3 11340 17400 7371 11310 1177 12 x 18 5750 3900 4100 (2) 18.5 35 66.7 (2) 5.5 68.4 14376 20520 9344 13338 1525 12 x 18 5750 3900 4300 (2) 22 40 67.4 (2) 5.5 68.4 16224 22680 10546 14742 1691 12 x 18 5750 3900 4500 (2) 30 57 63.8 (2) 5.5 68.4 17436 25800 11333 16770 NOTE: Do not use for construction. Refer to your sales representative for certified weights & dimensions. Data subject to change for product improvement.

14 www.fct.net.au COMPONENTS AUSTRALIAN MADE components Fibreflow Components Include: PVC Fill Eliminators Inlet Louvres Centrifugal Fan Wheel Fan Housings Fan Shafts Fan Bearings Nozzles Float Valves Pultruded Components Axial Fans FRP Fan Stacks FRP Hot Water Basins Gearbox assemblies including new or rebuilds Pulleys and Belts Access ladders & Platforms Guard Rails Replacement Coils Custom Designs Engineering and Design Repair and Overhaul of Fans Balancing Facilities including Static and Dynamic Onsite vibration analysis and balancing Pattern and Mould making Facilities Manufacture of FRP Components using hand lay, Press Moulding and Vacuum Moulding Techniques Manufacture of Fan Housings and Fan Stacks High Performance Laminates in e-glass or Carbon Reinforcements

www.fct.net.au 15 ENGINEERING DESIGN LAYOUT Air Flow When considering installation the unit must have suitable fresh air available to ensure correct operation of the system. Care must be taken to ensure moist air does reticulate back into the air inlets and due consideration must be given to ensuring discharge air does not flow into separate fresh air intake for building air-conditioning systems. Consult local regulations for details. Multiple Cells When using or combining multiple cells as a single component cooling source, equalizer lines must be installed to ensure balanced operation. Units must be mounted on the same level on secure plinths. Pipe Work Valves should be installed on all pipe connections and the correct pipe sizes must be used to ensure correct operation. Pipe work and other components to the system should be installed in a manner that ensures the system water does not flow into the cooling tower causing overflow and water loss on shut down. On start up the water level would drop considerably causing air to be introduced into the system. Preferably such pipe work and components should be located under the level of the basin operating level. Pipe work and ducting cannot be supported from the tower structure. De-Rating If installing cells hard against each other then a de-rating must be applied - generally around 5%. Consult Fibreflow Cooling Towers for confirmation. Placement When installing in plant rooms and applying ductwork and restricted air supply the external static pressure will increase. Motor size will need to be increased to overcome additional load - consult factory for advice. Layout Clearances Refer to engineering for layout clearances. Rule of thumb, 1500mm all around minimum.

16 www.fct.net.au ACCESS AND MAINTENANCE Health and Safety Fibreflow Cooling Towers adhears to local government regulations and Australian Standards. Working Platforms Fibreflow Cooling Towers offers a full range of working platforms with access ladders, low level and high level, multiple cell platforms and movable working platforms. All platforms conform to the Australian Standard AS1657. Configuration Standard configurations are available as shown, as well as custom-made to suit a specific location. Materials Material including hot dipped galvanized steel, aluminium, stainless steel and fibreglass. Crane Mounting Davit cranes mounted on platforms for motor removal are also available as shown.

www.fct.net.au 17 SOUND LEVELS Noise The noise that humans can hear covers a frequency from 20Hz to 10,000Hz. There are exceptions, however these levels have become accepted for most practical purposes. This audio band has been divided into eight bands called octave bands. The noise of cooling towers is controlled by many contributing factors such as layout, adjacent structures, variable speed drives, etc. Low noise options are available please consult your representative for further assistance. Sickle Fan The Sickle axial fan series are the answer for generating pressure with low noise axial fans. The sickle blade s swept design and thin trailing edge reduce pure tones in the sound spectrum and decrease vortex shedding to generate low wake turbulence for a quieter axial fan. The sickle profile s large chord length and overall surface area also combine to generate greater pressure at slower speeds. The sickle axial fans are Fibreflows natural choice for applications where low noise capabilities are a much required first priority. Reduces noise by up to 7 db(a) Maintains performance at lower speeds Sickle Blade Large chord length generates greater pressure

18 www.fct.net.au LIFTING TECHNIQUES Lifting Lifting Cooling Towers incorrectly can cause the unit to buckle. Please take the following precautions when installing your towers or alternatively, have Fibreflow take care of installation for you. Use soft slings only Beware of possible crushing of the Tower Casing when Lifting Use only Tested and Tagged Lifting Gear Licensed Crane Operators Always insure there is an exclusion zone whilst lifting is underway Cooling Tower Being Lifted Refer to our factory for further information. Cooling Tower About to be Lifted

www.fct.net.au 19 PLINTH ARRANGEMENTS Plinth arrangements are done based on the size and weight of the cooling tower. Please refer to our factory or your representative for further information.

20 www.fct.net.au VARIABLE SPEED DRIVES Variable Speed Drive Cooling Tower Fans Cooling towers are used in conjunction with water cooled chillers which are highly efficient. The tower fans cool the water with ambient temperature air. Drives replace two speed motors to regulate the condenser water temperature. During light loads or cool days, the cooling tower has too high of a capacity. The drive regulates the fans speed to maintain the set point to optimise the energy consumption. A temperature sensor is placed in the condenser water return line or in the cooling tower basin. A minimum speed of 15% is needed on gear driven fans to maintain proper gear lubrication. System Advantages Substantial Energy Savings No Air Surge/ Water Hammer on Start-up Redused Noise Wider Operating Range Cooling Tower Fans Sensor Placement Fibreflow Cooling Towers recommends the use of VSD s on all installations to conserve energy, and reduce wear on mechanical components.

www.fct.net.au 21 FREIGHT Freight Depending on transport requirements, box sizes up to 3850 x 1450 are generally shipped assembled, unless otherwise specified. 2400 x 2400 units are shipped in two sections for final assembly on site, alternatively these are supplied in complete knock down format (CKD) All other units are shipped in CKD format to reduce transport and handling costs. Cooling Tower Components Packed for Shipping Fiberflow has a fleet of trucks to deliver your Cooling Tower to any destination around Australia and can also ship to anywhere in the world. Cooling Tower Components Packed for Shipping

22 www.fct.net.au SITE ASSEMBLY Site Assembly Fibreflow Cooling Towers offer a complete onsite assembly service to ensure that the products are assembled in the correct manner. They can be assembled quickly and safely onsite or offsite depending on your needs. Fiberflow can work well with many companies/ contractors to ensure that the assembly is completed smoothly whilst onsite. It is not compulsory that Fibreflow Cooling Towers or its authorised representatives assemble the units however it is preferred. Cooling Tower Being Assembled CKD units can be purchased with assembly instructions for those wishing to assemble themselves. Cooling Tower Being Assembled

www.fct.net.au 23 COMPLIANCE WITH THE STANDARDS Compliance with Standards Fibreflow Cooling Towers are designed and constructed to meet the following Standards: AS3666 - Air Handling and Water Systems of Buildings Microbial Control AS4180.1 - Drift Test AS1170 - Wind Loads AS1657 - Code for platforms, ladders, stairways and walkways AS3500 - Australian Plumbing Code CTI STD 136 - PVC materials for use with fill, louvres and drift eliminators BCA - Building Code of Australia MEPS - Electric Motor Standard Compliance Performance Guaranteed Fibreflow Cooling Towers guarantee the THERMAL PERFORMANCE of our cooling towers The performance evaluation is taken as per CTI Test Code ATC 105 The thermal performance guaranteed is that submitted in the technical data on which the purchase order was based in free field conditions unless otherwise stated

24 www.fct.net.au MODULAR DESIGN Modular Design Fibreflow Cooling Towers can be assembled on site. Dedicated professional team of tradesman to assemble on site Hard to get into plantrooms, no issues. Towers are manufactured modular for that exact reason. No issues with wide load movement No issues with rain delays or road works Assured quality construction if assembled on site with no transport issues Over 30 years of on site construction experience Safety is main priority No location too remote

www.fct.net.au 25 NOTES

South east asia papua new guinea Australia pacific islands NEW ZEALAND HEAD OFFICE PO BOX 219 6/ 36 Blanck St Ormeau 4208 QLD Australia Phone: 1300 784 093 Fax: 1300 784 095 Mobile: 0408 013 366 Web: www.fct.net.au Email: info@fct.net.au MANUFACTURING PLANT 2/ 4 Cumberland Avenue South Nowra 2541 NSW Australia Phone: (02) 4422 6890 Fax: 1300 784 095 Web: www.fct.net.au Email: factory@ctms.net.au pvc fill MANUFACTURING facility PO BOX 219 2/ 36 Blanck St Ormeau 4208 QLD Australia Phone: 1300 784 093 Fax: 1300 784 095 Web: www.fct.net.au Email: info@fct.net.au Efficiency and Safety in Design Contact your Local Representative AUSTRALIAN MADE