COMMERCIAL MULTIPORT VALVES

Similar documents
TRIMLINE CARTRIDGE FILTERS

FULFLO CARTRIDGE FILTERS

BRITESTREAM LED FIBREGLASS NICHE POOL LIGHTS

BRITESTREAM SLIM90 FIBREGLASS POOL LIGHT

PRESSURE BOOSTER 150

TRIMLINE CARTRIDGE FILTERS

pump supatuf ECO Energy Saving 3 Speed Pump

pump Hydrostorm ECO-V Energy Saving Variable 3 Speed Pump

PUMP HYDROSTORM ECO. Energy Saving 3 Speed Pump.

pump Hydrostorm ECo Energy Saving 3 Speed Pump

pumps high performance

PUMPS HIGH PERFORMANCE.

Hydrostorm ECO-V 150 Energy Saving Variable Speed Pump

Waterco high performance pumps

Micron Commercial Fibreglass Filters

Sand Filtration System

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

Pressurized Bead Filters

Manual for 12 Sand Filter/ Pump Combo Unit.

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS. Viron CL Series Viron Cartridge Filter Cartridge Filter

Jandy Pro Series NeverLube and Backwash Valve

INSTALLATION AND OPERATING INSTRUCTIONS

Jacuzzi. J-SF24 Media Filter Installation and Operating Instructions

HIGH RATE SAND FILTERS

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Jandy FloPro (FHP) Series Pump Parts Replacement Kit Instructions

DIVERTER AND CHECK VALVES 1-1/2 IN. AND 2 IN. 2-WAY, 3-WAY AND CHECK

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS. Viron P280. Viron Cartridge Filter.

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

LAWN SPRINKLER, IRRIGATION PUMP

INSTALLATION AND OPERATING INSTRUCTIONS

Zodiac VS FloPro Variable-Speed Pump Series E3 INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

DISASSEMBLY & REASSEMBLY INSTRUCTIONS

DIVERTER AND CHECK VALVES 1-1/2 IN. AND 2 IN. 2-WAY, 3-WAY AND CHECK

Ph: (07) Fax: (07) Pump Manual

QL 420 / 540 CARTRIDGE FILTER

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

VOLUMETRIC FILTER MODELS T450 T500 T600 T700 T600B T700B

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Sanitary Design Control Valves V972. Instruction Manual. Installation & Maintenance instructions for W.Arthur Fisher V972 series control valves

Owner s Manual WARNING

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

Filter Parts. CV Series Cartridge Filter Part #CV340, CV460, CV ZODIAC POOL SYSTEMS CATALOG 51. Filter Parts 1,6 13, 21 12,11 18, 21 15, 21

AIR MOTOR DRIVE

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471

HARMSCO Filtration Products BC6 Series

SWIMMING POOL CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS

DeZURIK SPRING RETURN CYLINDER OPERATOR FOR G-SERIES ACTUATORS USED ON PEF 100% PORT ECCENTRIC VALVES

Gas Actuated Valve Supplement

INSTALLATION AND OPERATING INSTRUCTIONS

BINKS MODEL ROVING CUTTER

VALVE PARTS. Valve Parts

INSTALLATION AND OPERATING INSTRUCTIONS

VALVE PARTS VALVE PARTS

SERIES G3DB/AG3DB ELEVATOR

PMV P36C AND P41C POSITIONERS ACTUATORS

10 Fully Automatic Backwash Valve 1½ and Half Automatic Backwash Valves 1½ and 2, 3 and 4 Motorized 6-Way-Valves. Side Mount, Screw on top

R18TP. ORIGINAL INSTRUCTIONS 18V Transfer Pump

STEP-BY-STEP INSTALLATION GUIDE

Brake Pressure Setting. Model Number

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

M A I N T E N A N C E G U I D E V A L V E I N S T A L L A T I O N A N D IMPORTANT INFORMATION SERIAL NUMBER

Important. Contents. Contact us:

T100 Hybrid/T200 Hybrid

Maintenance Information

INSTALLATION AND OPERATING INSTRUCTIONS

OWNER / INSTALLATION MANUAL SAND FILTER SYSTEM

Instruction Manual. Maximum Operating Pressure 700 bar

MODEL C-COBRA SERIES CONVERTER REPAIR KIT INSTRUCTIONS

AquaView. Sand Filter with 7 Position Valve Includes pump/filter base. Owner's Guide

INSTALLATION & MAINTENANCE MODEL mm

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

AMIAD Automatic Filters

SECTION 8 2 DO IT YOURSELF MAINTENANCE. Chassis

DeZURIK CYLINDER OPERATED T-SERIES ACTUATOR

Pantera Cartridge Filter II PCF-II

Binks MODELS & AGITATOR DRIVE UNITS

Disassembly and Assembly

Centrifugal PTO Pumps. 2 nd Edition

or OWNER S MANUAL MODEL R

T60 REGULATOR REPAIR KIT INSTRUCTIONS

DeZURIK M-SERIES MANUAL ACTUATOR

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Meteor Filter System Kit Owner's Manual

AGITATED LID ASSEMBLY

Above Ground Cartridge Filters Models PRC50, 5PRC50, PRC75 and 5PRC75

Grow-With-Me Trike. Instructions. Model Number: Keep these instructions for future reference, as they contain important information.

Operating and Maintenance Manual Gas & Diesel Engine Powered Diaphragm Pumps. Series 55A

IWAKI Magnet Gear Pump MDG-M4 Instruction Manual

Cylinder and Valve: AirHawk II Air Mask

ENTERPRISE E56 - E106 - E156

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

ESE Series Cast Iron Sewage Pumps

Transcription:

COMMERCIAL MULTIPORT VALVES Owners Manual 65 mm Top mount 65 mm Side Mount 80 mm Top Mount 80 mm Side Mount 100 mm Side Mount! WARNING This equipment must be installed and serviced by a qualified technician. Improper installation can create electrical hazards which could result in property damage, serious injury or death. Improper installation will void the warranty. Notice to Installer This manual contains important information about the installation, operation and safe use of this product. Once the product has been installed this manual must be given to the owner/ operator of this equipment. www.waterco.com

! DANGER WARNING CAUTION NOTICE : This is a safety symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury. Warns about hazards that will cause death, serious personal injury, or major property damage if ignored. Warns about hazards that will cause death, serious personal injury, or major property damage if ignored. Warns about hazards that will or can cause minor personal injury or property damage if ignored. Indicates special instructions not related to hazards. Carefully read and follow all safety instructions in this manual and on equipment. Keep safety labels in good condition; replace if missing or damaged. Hazardous WARNING Hazardous pressure Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Read and follow instructions in owner s manual when installing and operating equipment. Have a trained professional perform all pressure tests. 1. Do not connect system to a high pressure or city water system. 2. Trapped air in system can cause explosion. BE SURE all air is out of system before operating or testing equipment. Before pressure testing, make the following safety checks: Check all clamps, bolts, lids, and system accessories before testing. Release all air in system before testing. Water pressure for test must be less than 25 PSI (172 kpa). Water Temperature for test must be less than 100 F. (38 C). Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Remove trap lid and retighten hand tight only.

Waterco Commercial Multiport Valves I pg 02 Features One-piece body made from moulded glass-reinforced engineering plastic provides incredible strength and durability. 304 Grade Stainless Steel used throughout to withstand harsh water conditions. Multiple valve positions available with the turn of a handle, including: Filter, rinse, bypass, backwash, winterise, waste Supplied with pressure gauge and fitted with ¼ inch BSP air release valve. Sight glass fitted to waste line for easy inspection of the backwash water. WASTE INLET FILTER Designed for a 400 kpa (58 psi) operating pressure. FILTER OUTLET RETURN Connecting Multi-Port Valve to Filter System Use care before assembly not to damage union sealing surfaces or O-Ring. Install union O-Rings in groove; tighten union collar hand tight. FOR SLIP FITTINGS: Use correct solvent/cement when fitting piping or adapters to slide valve. The valve body is ABS plastic, thus any good quality ABS to PVC solvent can be used. Use primer on PVC components only. Allow a minimum of four hours drying time prior to pressure testing or operation. To avoid serious personal injury or property damage, follow cement manufacturer s instructions exactly. Multiport Valves and Waterco Filter Models Part Number Valve Model Filter Models Connections 2280600 TM 65 mm MPV S1050 S1200 65 mm 22905010 SM 65 mm MPV SM1200 SMD1050 65 mm SMDD 900-1050 228800 TM 80 mm MPV S1200 80 mm 2290820 SM 80 mm MPV SM1200-1400 SMD 1050-1400 SMMD 900-1400 80 mm SPPD 1050-1200 2291005 SM 100 mm MPV SMD 1200-1800 SMDD 1200-1800 SPDD 1400-1600 100 mm TM = Top Mount SM = Side Mount

FUNCTIONS OF THE MULTI-PORT VALVE Hazardous WARNING Hazardous pressure!! Hazardous pressure. Can cause severe injury or major property damage from valve blow up. Release all pressure and read instructions before working on system. To avoid severe injury and major property damage, stop pump before changing handle positions. To avoid major property damage due to flooding, make sure pointer is accurately positioned and down all the way before restarting pump. Press down on handle to release pressure before turning. 1. FILTER Normal position during operation of system. 2. BACKWASH Position when operating system to purge filter of accumulated debris. This normally is necessary when filter pressure gauge reads 10 PSI higher than starting pressure on a clean filter. Consult your filter operating instructions. 3. RINSE This position is only used with sand filters and is designed to flush stray sand from system before returning to filter operation after backwashing. Consult your filter operating instructions. 4. WINTERISE Allows drain and winterise filter and pump according to manufacturer s instructions. 5. BY-PASS This position permits pump to continue recirculating water (chemicals, heat, etc.) without flow through filter. This is advantageous when filter or its components are being repaired or replaced. 6. WASTE This position permits draining or lowering of pool water level. When pump is stopped with valve in this position, quickly move handle to another position to avoid air getting into piping. VALVE MAINTENANCE! To avoid severe personal injury and major property damage, stop pump and release all pressure from system before servicing valve. No regular maintenance is required for proper operation of multi-port valve. Winterizing For Freezing Climates: Place valve handle in winterise position.

Waterco Commercial Multiport Valves I pg 04 PART REPLACEMENT To prevent flooding, make sure that system is drained or isolation valves are closed before opening multi-port valve. Handle Replacing Handle: 1. Place handle in FILTER position. 2. Remove handle pin from handle; remove handle and replace with new one, making sure pointer is in FILTER position. 3. Replace pin by tapping lightly into place with hammer. Pin Spring Figure 1 Replacing Cover and Rotor Assembly (as a unit): 1. STOP PUMP and release all pressure from system. 2. Remove all bolts and nuts around perimeter of cover. 3. Remove assembly by lifting straight up. 4. Align cover pin (see Figure 2) and install new cover and plug. Press down on cover to allow bolts to engage nuts; tighten each bolt securely. Align Tabs Figure 2 Replacing Internal Valve Parts: 1. STOP PUMP and release all pressure from system. 2. Place handle in FILTER position. 3. Remove all the bolts and nuts in order to replace any internal parts. 4. Remove cover by lifting straight up. 5. Remove handle pin and handle (See procedure Replacing Handle above) 6. Remove washer. 7. While disassembled, check condition of plug, rubber gasket, spring, O-Ring, and internal plastic washer. If any of these parts appear worn, replace them. 8. Reassemble plug, cover, and handle by compressing spring (See Figures 1 and 2) and reversing procedure Replacing Cover and Rotor Assembly above. 9. Before reinstalling cover, be sure plug and handle are in same position as when cover was removed. 10. Tighten each bolt securely.

Spider Gasket Replacement: NOTICE: Read instructions completely before starting. 1. STOP PUMP and release all pressure from system. 2. Remove the bolts and nuts holding the cover to the valve body. Remove the cover assembly. 3. Remove the old gasket from the valve rotor. 4. Make sure that the gasket groove is free of water, grease, oils, debris and parts of the old gasket. Use alcohol to degrease. 5. NOTICE: Once this step is started, continue through Step 9 without interruption. Apply glue sparingly (a bead about 1/16 wide) to the bottom only (not the sides) of the spider groove in the valve body. The glue lines must be continuous and intersect at the intersections of the grooves. 6. Insert the new gasket into the groove with the rounded bead up. Press the gasket firmly into all groove areas to seat the new gasket evenly. 7. Align the tab on the cover assembly with the pin on the valve body (See Figure 2) and insert the cover assembly into the body, fastening it with the bolts and nuts removed in Step 2. Tighten all bolts securely. 8. Depress the valve handle and rotate it to the closest standard position (FILTER or RINSE), being careful not to rub the plug on the new gasket. Release the handle, allowing the plug to hold the gasket in place while curing. 9. Minimum cure time is 2 hours. Curing for 24 hours is recommended for full strength Valve Position Functions Valve Setting FILTER BACKWASH RINSE WASTE WINTERISE BY PASS Flow direction through valve PUMP TOP THROUGH FILTER BOTTOM RETURN For normal filtration through filter. PUMP BOTTOM THROUGH FILTER TOP WASTE For reversing flow for cleaning filter. PUMP TOP THROUGH FILTER BOTTOM WASTE For initial start-up cleaning plus resetting filter bed after backwashing. PUMP WASTE For draining water. NO CIRCULATION PAST PUMP PORT For shutting off all flow to filter. Air fittings.

Waterco Commercial Multiport Valves I pg 06 Top Mount Configuration MULTIPORT VALVE MULTIPORT VALVE OUTLET VALVE TO WASTE DIRT FLUSHED OUT SAND Filter Mode Backwash Mode Side Mount Configuration INLET VALVE OUTLET VALVE DIRT FLUSHED TO OUT DRAIN INLET VALVE SAND Filter Mode Backwash Mode Warranty is stated in a separate document

Multiport Valve 65 mm (Side Mount) Assembly Item Qty Part Number Name 1 1 621451 HANDLE 2 1 621111 HANDLE PIN 3 12 W12109 SCREW 4 1 W02627 TEFLON WASHER 5 2 621201 AXIAL O RING 6 1 W02628 TEFLON WASHER 7 1 621182 SPRING 8 1 621152 LID O RING 1 621233 ROTOR WITH GASKET 9 1 621234 ROT0R 1 621235 SPIDER GASKET 10 2 620221 AIR RELIEF WITH O RING 11 1 6211302 LIF 12 1 6213021 BODY 13 3 63406554 O RING 14 3 644490 B/U PLAIN END 15 3 63406551BLK B/U LOCK NUT 16 1 621381 SIGHT GLASS 17 1 621341 SIGHT GLASS GASKET 18 3 112780 COUPLING 80 mm 19 12 W02624 NUT

Waterco Commercial Multiport Valves I pg 08

Multiport Valve 80 mm (Top Mount) Assembly Item Qty Part Number Name 1 1 621100 HANDLE 2 1 6211020 HANDLE PIN 3 1 6211310 LID 4 1 621243 ROTOR 5 1 621272 SPIDER GASKET 6 1 6211060 TEFLON WASHER 7 1 621192 SPRING 8 2 621202 O RING AXLE 9 1 621192 BODY (T/MOUNT) 10 1 621193 SLEVE 11 1 621142 O RING LID 12 2 620221 AIR RELIEF VALVE 13 1 621341 SIGHT GLASS GASKET 14 1 621381 SIGHT GLASS 3 W02255BLK B/U P/END 80 mm 15 3 W02253BLK B/U LOCK NUT 80 mm 3 W02249 O RING B/U 80 mm 16 14 W12109 BOLT M6x32 17 14 W02624 NUT M6 18 1 621013 DIFFUSER 19 1 621194 DIFFUSER O RING 20 1 W02742 O RING 9 mm

Waterco Commercial Multiport Valves I pg 10

Multiport Valve 80 mm (Side Mount) Assembly Item Qty Part Number Name 1 1 621100 HANDLE 2 1 621193 SLEVE 3 1 6211020 HANDLE PIN 4 2 621202 O RING AXLE 5 14 W12109 SCREW 6 14 W02624 NUT 7 1 6211310 LID 8 1 621142 O RING LID 9 1 6211060 WASHER 10 1 621192 SPRING 11 1 621243 ROTOR 12 1 621272 SPRIDER GASKET 13 1 621293 BODY 14 5 W02253BLK LOCK NUT B/U 80 15 5 W02255BLK PLAIN END B/U 80 5 W02255EBLK PLAIN END B/U 90 16 5 W02249 O RING B/U 80 17 5 620221 AIR RELIEF VALVE 18 1 621341 GASKET SIGHT GLASS 19 1 621381 SIGHT GLASS

Waterco Commercial Multiport Valves I pg 12

Multiport Valve 100 mm Assembly Item Qty Part Number Name 1 1 621100 HANDLE 2 1 6211020 HANDLE PIN 24 W12781 SCREW 3 24 W12783 WASHER SPRING 48 W12782 WASHER FLAT 4 1 6211060 WASHER 5 1 621202 AXIAL O RING 6 1 621193 SLEVE 7 1 62110150 SPRNG 8 1 62110110 LID O RING 9 1 62110220 ROTOR 1 62110130 SPIDER GASKET 10 2 620221 AIR RELIEF VALVE 11 1 6211028 LID 12 1 6211029 BODY 13 5 W02553 O RING 14 5 12221011 B/U PLAIN END 15 5 1221009 B/U LOCK NUT 16 1 621381 SIGHT GLASS 17 1 621341 SIGHT GLASS GASKET 18 24 W02624 NUT

Waterco Commercial Multiport Valves I pg 14

Offices - Australia NSW - Sydney (Head Office) Tel: +61 2 9898 8600 QLD - Brisbane Tel: +61 7 3299 9900 VIC/TAS - Melbourne Tel: +61 3 9764 1211 WA - Perth Tel: +61 8 9273 1900 SA/NT - Adelaide Tel: +61 8 8244 6000 ACT Distribution Tel: +61 2 6280 6476 OFFICES - OVERSEAS Waterco (Europe) Limited Sittingbourne, Kent, UK Tel: +44 (0) 1795 521 733 Waterco France Saint Priest, France Tel: +33 4 72 79 33 30 Waterco (USA) Inc Augusta, Georgia, USA Tel: +1 706 793 7291 Waterco Canada Longueuil, Quebec, Canada Tel: +1 450 748 1421 Waterco (NZ) Limited Auckland, New Zealand Tel: +64 9 525 7570 Waterco Limited Guangzhou, China Tel: +86 20 3222 2180 Waterco (Far East) Sdn Bhd Selangor, Malaysia Tel: +60 3 6145 6000 PT Waterco Indonesia Jakarta, Indonesia Tel: +62 21 4585 1481 Waterco Singapore Intl Pte Ltd Nehsons Building, Singapore Tel: +65 6344 2378 Waterco Limited ABN 62 002 070 733 (ZZM1438) 05/2012