Integrated Control modules

Similar documents
Integrated Control modules

Contents. FieldQ. FieldQ. Product data sheet Rev. 0 October FieldQ Valve Actuator 2. FieldQ Actuator Torque 4

Installation Guide Integrated Control modules

Bettis Integrated Control Modules QC41 24VDC QC42 115VAC QC43 230VAC

Sensor boxes SRBE Key features and product range overview

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Electrical position feedback for actuator sizes Ø mm

Pneumatic control unit for decentralized automation of ELEMENT process valves

GTV Series High Pressure Control Valves

FieldQ Control Module QC40 AS-Interface

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Linear actuators DFPI

Poppet Valves Series. Keeping the World Flowing

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Features. Flexibility

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

LIMIT SWITCHES & POSITION INDICATION

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Accord DS/DM Series UltraSwitch Switch box

Linear Valve Electric Actuator

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Bus / Coach Door Obstruction Detection

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

INSTRUCTION MANUAL (ATEX / IECEx)

Solenoid coil for control in potentially explosive areas Type BZ

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

VALVCON ADC-SERIES ELECTRIC ACTUATOR WITH OPTIONAL BATTERY BACK-UP POWER

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Position Switches Series 8070/2

INSTRUCTION MANUAL (ATEX / IECEx)

Control Buttons / Switches for Panel Mounting Series 8003

Automation Capabilities

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Position Switches Series 8060/2

General purpose / hazardous area

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

97100 NAMUR. Technical data

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

Level limit switch Series RF 3000 Selection list

HERION SERIES Indirect solenoid actuated soft seal

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Pure-Flo. Automation & Control.

Type Z & Ex pz purge and pressurization system

Installation and Operating Manual

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

97105 Inline. Ordering information. Technical data. Accessories See page 5

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

4.3 MSK SWITCH BOX MSK (SIZE I) FEATURES ADVANTAGES

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

ELECTRIC MULTI-TURN ACTUATORS for valve automation in the oil & gas industry with high torque requirements

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Linear luminaire with LED Series EXLUX 6002

brands you trust. CRANE - Automation Actuators and Instrumentation

Type Electronic Limit Switch

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Load and Motor Switches, Load-Break Switches Series 8544

Valve Position Monitors

Position Switches Series 8074/2

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Linear Luminaire with LED Series EXLUX 6002

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

FICHA TÉCNICA DE PRODUTO

Fisher i2p 100 Electro Pneumatic Transducer

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

V200 Series Positioners

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Series 581 ISO Pneumatic Directional Control Valves

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Installation Operation Maintenance

Load disconnect switch Series 8146/5-V11

BMRX Series ROTARY LEVEL CONTROL

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Valve Position Monitors

VALVES WITH NA ELECTRIC ACTUATOR

Floodlight LED Series 6125

BC 4.2. Tunnel Ventilation Dampers. TVD-GB-40-B Fire Rating 4Hrs As per BS476 Leakage Rating: Class-I As per UL-555S LISTED

Load and Motor Switches, Load-Break Switches Series 8549

SERIES 54 Inductive Proximity Sensor

Redundant Control System

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Transcription:

.60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last Position applications. - Suitable for all actuator sizes. - Available as "Weather Proof" for indoors or outdoors use and "Explosion Proof" for areas with a potential explosion hazard. - The robust aluminum alloy enclosure (IP66 / NEMAX rated), protects the IPT system, pneumatic components, the feedback switches and terminals and makes it suitable for indoor and outdoor use. - The Explosion Proof version is available with ATEX / IECEx Ex d approval for use in Zone, 2, 2 and 22 and/or FM / CSA Explosion proof approval for use in Class I, Division. - Various feedback switch options available. - Non-Intrusive switch point adjustment of the feedback switches. Allows to adjust switch points without opening the Control Module. - Lockable Control Module cover. - All the control and feedback connections can be wired through one single entry to the Control Module. - One larger entry (/"NPT) is available for larger multicore cables on imperial units. APPROVED Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page 2 of 9 : These conventionally wired control modules are the next step for the integrated concept of valve automation. Next to the components for feedback switches, also all the pneumatic control components are located inside one module housing. Its compact and robust construction incorporates basic control and feedback functionality and is suitable for indoor and outdoor use. These modules are available with ATEX and IECEx certification for use in Zone, 2, 2 and 22, and additionally FM and CSA certified for use in Class I, Division. Construction: The Control Module is mounted at the side of the basic actuator housing. Inside, wiring terminals are available for connecting control and feedback signals. Two cable entries are available. The pilot valves inside the control module are used to send the actuator to its open or closed position. One pneumatic connection is available to feed the control module. General specifications: Material housing: Aluminium alloy Operating media: Air or inert gasses, filtered at 50µm (for QC5 5µm) Pneumatic entry: Metric units: G/" Imperial units: / NPT Electrical connections: Pilot valve(s): 6 pole terminal strip. Switches: 6 pole terminal strip. Cable entries: Metric units: 2x M20x.5 Imperial units: /2 and /"NPT Enclosure: Rated IP66 - NEMAX Switch points: Factory set at 5 before each end of travel (open and closed position). - Adjustable range: Between - to 5 and +75 to +9 of the end position. Finish: Chromated, polyurethane based coating. Temperature range: Depends on the switches inside the module and or Hazardous Area approvals (See section "Position feedback" Dimensions: Metric: See data sheet BQ.60.08 Imperial/UNC: See data sheet BQ.60.09 DIN 7: See data sheet BQ.60.0 Electrical safety requirements: Use : In- and outdoor. Altitude : Operating full power available up to 2000 meter (6000 feet). Maximum relative : 80% for temperatures up to C humidity (87.8 F) decreasing linearly to 50% relative humidity at 0 C (0 F). Mains supply : Up to ±0% of nominal voltage fluctuation Over voltage category : II Pollution degree : 2 ( when the cover remains closed) Terminal compartment Lockable Module cover Electrical entries: / NPT or M20 /2 NPT or M20 Switch terminals Pilot valve terminals Control module overview Control Module Type Label Option: or 2 speed control throttles Pneumatic connections: / BSP or / NPT Option: Additional Local Manual Control for Fail in Last Position Option: Local Manual Control Non-Intrusive switch point adjustment Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page of 9 Pneumatic control Pneumatic control variations The Control Module contains all the necessary pneumatic components to control the actuator and control the incoming and outgoing airflow. Pneumatically the modules are available for three applications: Spring return or 2 Double acting or Double Acting - "Fail-in-Last-Position". To achieve these functions, each Control Module can be fitted with one or two pilot valves depending on the required functionality: One pilot valve is default and suitable for normal operation of double acting or spring return actuators 2 Two pilot valves are required to achieve a "Fail-in-Last- Position" functionality on double acting actuators. Table : Pilot valve specifications Module Voltages Power Frequency QC 2VDC (±0%) W NA QC2 5 VAC (±0%) VA 50/60Hz QC 20 VAC (±0%) VA 50/60Hz Cable range: 0. - 2.5mm 2 or 22-2AWG One default pilot valve and wiring connections Pilot valve Pilot valve Pilot valve 2 Pneumatic cartridge Cable range: 0. - 2.5mm 2 or 22-2AWG FILP = Fail in Last Position Wiring diagram shown, is applicable for actuators with assembly code CW. For actuators with assembly code CC (reverse acting) the Open and Closed pilot valve connections are also reversed. Two pilot valves and wiring connections for Fail in Last Position Pilot valve cartridge Pilot valve terminals Pilot valve and pneumatic cartridge Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page of 9 Pneumatic components The pneumatic components inside the module consist out of one or two pilot valves and a /2 spool valve or 5/2 bistable spool valve. The spool valves are pneumatically operated by the pilot valves. To assure trouble-free operation, the spool valves are equipped with big ports. This enables a large air flow and makes it less sensitive for contamination of the internals. The large air flow also fast cycle times and enables it to be utilized for the entire actuator range. Internal corrosion protection: The spring return models have standard a built in Breather function. During the spring stroke, the exhaust air from the center chamber (A-Port) is first fed to the spring chamber (B-port) preventing air from outside from being sucked into the spring chamber. This reduces the possibility of internal corrosion and maximizes the actuators working life. Pneumatic options Fail safe (spring return) Ps Double acting Pilot valve A-port Option: Throttle /2 Spool valve Option: LMC B-port Ra Speed Control The can be supplied with a Speed Control option. One throttle is required for Spring Return actuators and up to two for Double Acting actuators. The speed control throttle controls the air flow in and out of an air chamber and as such limits the speed of the Opening and Closing stroke simultaneously. Silencers and vents The exhaust ports Ra and Rb on the module are shipped from the factory with transport protection. The module can be equipped with either silencers or vents. Manual Control For commissioning, emergency or maintenance purposes, the can be supplied with Manual Control options. These options can operate the actuator when there is air pressure available, but no control signal or power supply. - For normal operation the module should be fitted with one Manual Control. - For Double Acting with a Fail-in-Last-Position function, two Manual Control can be fitted. Maximum Flow rates of Q-Series modules The maximum flow rates depends mainly on the flow rates of the XP modules. You can use Kv 0.28 (m /h) or Cv value of 0.28 (US gall/min Psi) for approximate operating speed calculations. Ps Double Acting Fail in Last Position Ps Option: LMC Pilot valve A-port Option: Throttle 5/2 Spool valve B-port Option: Throttle 2 A-port B-port Option: Option: Throttle Throttle 2 5/2 Spool valve Option: LMC Option: LMC 2 Rb Ra Rb Ra Pilot valve Pilot valve 2 Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page 5 of 9 Position feedback Switch cartridges The position feedback is achieved by switch cartridges in the module. These cartridges contain switching elements which sense the open or closed position and are pre wired to the terminal strip. These easily exchangeable switch cartridges are available with various mechanical or proximity switching elements. Non-Intrusive switch point adjustment If required the switches can be adjusted without opening the module. This, so called, Non-Intrusive switch adjustment is located at the front of the module behind a locable () shield (2). Two adjustment screws are available for adjusting the Closed () and Open () position indication. DO NO GIZED Terminal strip position feedback switches 2 Switch cartridge Switch cartridges "Closed" Switch point adjustment "Open" Switch point adjustment Non-Intrusive switch point adjustment Important: - The above "Closed" and "Open" marked adjustment screws will adjust the valve's "Closed" or "Open" switch point, if the valve closes after a Clock Wise (CW) rotation. - If the valve closes after a Counter Clock Wise (CCW) rotation, the "Closed" marked adjustment screw will adjust the "Open" switch point. Similar, the "Open" marked adjustment screw will adjust the "Closed" switch point. Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page 6 of 9 Mechanical switches Table 2: Mechanical switches Specification Type Voltage Contacts Temperature range M G (gold contacts) Mechanical M: 277 VAC or 250VDC (maximum) G: 25 VAC or 0VDC (maximum) NO and NC -25 C to +65 C / - F to +9 F For use in hazardous areas, see table 7 2-Wire Proximity switches Table : 2-wire NAMUR proximity switches Specification Type Voltage Output Temperature range Compliant to N 2-wire inductive, normally closed 8 VDC nominal Unswitched, > ma Switched, < ma -25 C to +65 C / - F to +9 F For use in hazardous areas, see table 7 DIN EN 6097-5-6 (NAMUR) Table : Maximum currents Switch voltage M type switch G type switch 25 VAC 0 A ( A ) 0. A 2 250 VAC 0 A ( A ) - 0 VDC 0.5 A 0. A 2 25 VDC 0.5 A - 250 VDC 0.25 A - Note:. The mechanical (M-type) switches are rated for A with inductive load. 2 The mechanical (G-type) switches have gold contacts. For applications where the benefits of gold contacts are required, the maximum current is A.. For applications below -20 C (- F), the base actuator must be equipped with Low temperature seals. Table 5: Specification 2-Wire 20V proximity switches H Voltage 20...250VAC / 0...00VDC (50...60 Hz AC) Current Maximum 00 ma Leakage Temperature range Peak 0,9A (20ms / 0,5Hz), <.7 ma -25 C to +65 C / - F to +9 F For use in hazardous areas, see table 7 Note: For applications below -20 C (- F), the base actuator must be equipped with Low temperature seals. Wiring diagram: - M = Mechanical - G = Mechanical, gold contacts Wiring diagram: - 2-Wire NAMUR proximity switches - 2-Wire 5V proximity switches L- 2 L+ L- 5 L+ 6 2 2 Open Close Cable range : 0. - 2.5mm 2 or 22-2AWG Wiring diagram is shown in the actuators mid-stroke position. Wiring diagram for mechanical switches Open Close Cable range : 0. - 2.5mm 2 or 22-2AWG Wiring diagram for 2-Wire proximity switches Important: - The above "Closed" and "Open" marked adjustment terminals will indicate the valve's "Closed" or "Open" switch point, if the valve closes after a Clock Wise (CW) rotation. - If the valve closes after a Counter Clock Wise (CCW) rotation, the "Closed" marked adjustment terminals will indicate the "Open" switch point. Similar, the "Open" marked adjustment terminals will indicate the "Closed" switch point. Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page 7 of 9 -Wire Proximity switches Table : -wire proximity switches Specification Function Voltage Current Off-state current Temperature range O, V PNP C, V NPN Make 0-0V 00 ma maximum 0... 0.5 ma typical -25 C to +65 C / - F to +9 F For use in hazardous areas, see table 7 Note: For applications below -20 C (- F), the base actuator must be equipped with Low temperature seals. Wiring diagram: -Wire proximity "O" type switches PNP 2 5 6 L- L+ L- L+ PNP Open Close Wiring diagram: -Wire proximity "C" type switches NPN 2 5 6 L- L+ L- L+ NPN Open Close Cable range : 0. - 2.5mm 2 or 22-2AWG Wiring diagram for -Wire proximity switches Important: - The above "Closed" and "Open" marked adjustment terminals will indicate the valve's "Closed" or "Open" switch point, if the valve closes after a Clock Wise (CW) rotation. - If the valve closes after a Counter Clock Wise (CCW) rotation, the "Closed" marked adjustment terminals will indicate the "Open" switch point. Similar, the "Open" marked adjustment terminals will indicate the "Closed" switch point. Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page 8 of 9 Control Module Options QC, QC2 and QC Local Manual Control For commissioning, emergency or maintenance purposes, the can be supplied with one or two Manual Control options. These can operate the pilot valve(s) inside the module and as such operate the actuator, when there is air pressure available, but no control signal or power supply. Notes: - One Local Manual Control is required for normal operation of Double acting or Spring return actuators. - For Double acting actuator with a Fail-in-last position function, a second Local Manual Control can be mounted. - These options can be ordered together with the Control Module or as a kit to be mounted later. - For option ordering codes, see page 7 Speed Control The can be supplied with a Speed Control option. One throttle is required for Spring Return actuators and up to two for Double Acting actuators. The speed control throttle controls the air flow in and out of an air chamber and as such limits the speed of the Opening and Closing stroke simultaneously. This throttle consists of : Nut cover 2 Main throttle with set screw. Notes: - For Spring Return actuators with one speed control throttle, it is not possible to set both the stroke cycle times to an equal time. - Four Double Acting actuators it is possible to mount two speed control throttles. - The actual stroke cycle times depend on the actual load on the actuator during the different strokes. Spring Return: Top entry only. Double Acting: Location for 2nd Bottom and/or top entries. Lock Local Manual Control 5 Unlock On Default location of Local Manual Control 2 Off Local Manual Control option Speed control options Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center:

.60.0 Rev. 0 Page 9 of 9 Hazardous area specifications Modules QC, QC2 and QC Below specification are applicable for QC, QC2 and QC modules with a hazardous area approval. Hazardous area product marking; IECEx hazardous or Classified Location: Notes: Each control module is marked with the applicable ambient temperature marking. 2 Metric control modules are marked with ATEX and IECEx markings. Imperial control modules are marked with ATEX, IECEx, FM and CSA markings. Temperature rating Table 7: Temperature rating for use in areas with a potential explosion hazard. Module type Ex d IIB+H2 T/T6 Gb Ex t IIIC T80 C Db IECEx DEK 5.00X ATEX hazardous or Classified Location: 80 II 2G Ex db IIB+H2 T/T6 II 2D Ex tb IIIC T80 C DEKRA 5ATEX0055X Configuration Switch cartridge Pneumatic action Max. Power dissipation FM hazardous or Classified Location: CL I, II, III, DIV Groups BCDEFG, T/T6, Type X/6 APPROVED CL l, ZN, IIB+H2, T/T6 CSA hazardous or Classified Location: Class I, II, III, DIV Groups CDEFG, T/T6, Type X/6 Ex d IIB+H2 T/T6 DIP A2 TA 80 C Min. ambient Temperature ( C) Max. ambient Max. Surface QC (2VDC) S,D,F.6W ( -25 C (- F) +60 +80 T6/T M, G QC2, QC (5 or 20VAC) S,D.6W ( -25 C (- F) +60 +80 T6/T O, C, N, H QC2, QC (5 or 20VAC) F 7.2W (2-25 C (- F) +60 +80 T6/T Class Notes: x or 2x 2VDC pilot valves, or x 5/20 VAC pilot valve 2 2x 5 or 20 VAC pilot valves Switch cartridge M = Mechanical switches G = Mechanical switches (gold contacts) C = wire PNP proximity switch O = wire NPN proximity switch N = 2 wire proximity switch H = 2 wire proximity switch Pneumatic action S = Spring Return (Single acting). D = Double acting. F = Double acting (Fail in Last Position) Updated data sheets can be obtained from our website or from your nearest Actuation Technologies Center: