INSTALLATION INSTRUCTIONS PRO PLUS WIDE BAND AIR/FUEL RATIO

Similar documents
Installation _ + INSTALLATION GUIDE. 12V Ignition Switch. Good Engine Ground. Data Logger Output. Wide Open Throttle Switch (for WOT peak function)

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

General Information. Installation Tips. Connections

INSTALLATION & OPERATING INSTRUCTIONS INLINE WIDEBAND MODULE (BOSCH LSU4.9)

Installation Instructions for: DT2-AF2 Dual Channel & DT2-AF1 Single Channel Wide Band O2 Sensor Controller for A/F (Lambda) Measurement

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

FOR SERVICE SEND TO: AUTO METER PRODUCTS, INC. 413 W. Elm St., Sycamore, IL USA (815) us at

PRO-COMP/PHANTOM TACH

UNIVERSAL GAUGE WIRE HARNESS

NEXUS. Introduction SENSOR MODULE &

1955 & 1956 CHEVROLET CAR INSTALLATION INSTRUCTIONS

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

Temperature Programming Quick Reference Guide

Part Number AEM 4-CH WIDEBAND UEGO CONTROLLER

INSTALLATION INSTRUCTIONS THERMOCOUPLE EXPANSION MODULE

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

10 Ch Peak & Hold Injector Driver PN

3RD GEN CHALLENGER INSTALLATION INSTRUCTIONS

Installation Instructions for Gauge-Type UEGO Controller

Installation Instructions for AEM Serial Gauge

* NOTE: Legal in California only for racing vehicles which may never be used upon a highway

Part Number Analog EGT Gauge

Installation Instructions for NS No Sensor Gauge-Type UEGO Controller

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

Installation Instructions for AEM Tru Boost Boost Controller Gauge

Oil Pressure Display Gauges Part numbers: Analog Oil/Fuel SAE Pressure Gauge psi Analog Oil SAE Pressure Gauge.

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

FEATURES: SPEK PERFORMANCE GAUGE TACHOMETER FEATURES:

INSTALLATION INSTRUCTIONS MECHANICAL GAUGES

Installation Instructions for: Channel Thermocouple Amplifier

Part Number Analog Style 15 PSI Fuel/Boost Pressure Gauge. NOTE: Faceplate Configuration Instructions Included on Separate Sheet

Digital Fuel Gauge P/n (With Dual Ohms Range option)

P/N X-SERIES GAUGE VOLTAGE 8 TO 18V

Water/Methanol Failsafe

Part Number cc/min Water/Methanol Injection Flow Gauge

Multi-Input Water/Methanol Injection Harness

E9X/E8X/E6X CHASIS VEHICLES (With N54 Motors)

FAST Ethanol-Methanol Air/Fuel Meter

CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING

Flex Fuel Sensor Kit (Barbed) Flex Fuel Sensor Kit (-6AN)

CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING

Internal MAP Water/Methanol Injection Controller ,

# Traction Control Window Switch

Controller Ground (dual black 12awg) should be connected to chassis ground as close as possible to the battery.

HI-FLOW FUEL RAIL. Installation Instructions for Scion tc & xb AEM Fuel Rail AN Hose adaptor

MAXIMIZER-II Progressive Nitrous Controller INSTALLATION AND USER MANUAL. MAXIMIZER-II rev A

Optional: Wiring a Relay for Gauge Controlled Output

VW/AUDI MK7 VEHICLES

CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING

INSTALLATION INSTRUCTIONS 5" DUAL CHANNEL ULTIMATE TACH MODEL 6881, 6883, 6884, Dual Channel 1 CH 2

PLATINUM Series CAN WIDEBAND CONTROLLER WBC 1 & WBC 2 QUICK START GUIDE (HT & HT059980) Version 4

Wideband Failsafe Gauge Parts List

Flow Chart Programming Instructions for : Transmission Temperature 2 1/16 START HERE PROGRAM MAIN MENU

CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING

Components. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.

Programming Instructions for : Pressure 2 1/16 + DOWN MODE UP. Spek Pro Fuel Rail Pressure Gauge

Owner s Guide PR1BZ PR1BZLR

Owner s Guide APS596Z

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Simplified Check Program for Charging Systems

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

Owner s Guide. ca6154

ION-01-6 PERFORMANCE SPEEDOMETER/TACHOMETER COMBO

Lingenfelter ECSS-001 Ethanol Content Sensor Signal Simulator Installation & Operating Instructions

GM Stepper Idle Adapter User Manual

Installation Instructions for / Universal Water/Methanol Injection Kit

ca1153 Owner s Guide

Ford EV6 Injector Adapter Harness User Manual

ODY-19-1 AIR PRESSURE GAUGE

Owner s Guide CA 1155

DFS-1000 Wiring Diagrams and PC Software Installation.

GM Throttle Body Adapter Harness User Manual

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

CA 6550 Owner s Guide

Owner s Guide CA 1055

Remote Vehicle Control System CA-150. Owner's Manual. Vehicle Security System With Remote Keyless Entry

Owner s Guide CARS & CA4B5

MSD LS-1/LS-6 Controller for Carbureted and EFI Gen III Engines PN 6010

ca 1553 Owner s Guide

MSD 6LS-2 Ignition Controller for Carbureted and EFI LS 2/LS 7 Engines PN 6012

APSX WIDEBAND D2 Manual V1.0

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

Thank you for your purchase Off-ROad NOtice: PROduct WaRNiNgs:

INSTALLATION GUIDE. Dynojet Research 2191 Mendenhall Drive Suite 105, North Las Vegas NV,

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

MSD Stacker-4 (4-Channel), PN 7010 Stacker-8 (8-Channel), PN 7020

SLX300. Register your product. Send us your photos. Warranty COLOR CHANGING HEADLIGHT ACCENT LIGHTING SYSTEM. Installation Manual

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

ODY-17-1 DIGITAL COMPASS DISPLAY

INSTALLATION INSTRUCTIONS 5" DUAL CHANNEL ULTIMATE TACH MODEL 6881, 6883, 6884, Dual Channel 1 CH 2

Installation Instructions for P/N Universal Water/Methanol Injection Kit (without Tank)

Instruction Manual P/N Wideband Failsafe Gauge

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge

DynoTune Wideband Gauge

MSD-8 Plus Ignition PN 7805

Remote Vehicle Control System. Keyless Entry and Convenience System

HLY-1111 HEAD TEMPERATURE GAUGE

DYNOTUNE 2 STAGE RPM WINDOW SWITCH WITH TPS INSTALLATION INSTRUCTIONS

Transcription:

2650-1828-77 Installation 1. Disconnect the negative (-) battery cable. 2. Gauge can be mounted in a 2 1 16 dia. hole with brackets supplied. Gauge can also be mounted in Auto Meter Mounting Cup, or in Auto Meter Gauge Works Pods. 3. Wire gauge as shown. WARNING Sender Will Get Very Hot During Operation. CAUTION! As a safety precaution, the red wire of this product should be fused before connecting to the 12V ignition switch. We recommend using a 3 AMP automotive type fuse. Connect Data Acquisition Unit and Air/Fuel Ratio Monitor to a common grounding point INSTALLATION INSTRUCTIONS PRO PLUS WIDE BAND AIR/FUEL RATIO MONITOR Orange Pro Control Out Red Wire(Power): Connect to a fused and switched 12V positive source that is turned on and off with the ignition switch. Place a 3 amp automotive fuse (available commercially) in line with this connection to protect your gauge. It is recommended that vehicles without alternators connect this wire to a separate switch or direct to the vehicle s master cutoff switch. (See Sensor Heating Element Section) Black Wire(Ground): Connect to good engine ground. Brown Wire(Optional Peak/Recall & Warning WOT Switch): Connect to Wide Open Throttle Switch. Required for Peak Recall and Alarm/Warning Functionality. Blue Wire (Optional Data Logger Signal Output): Connect to signal input(+) or Engine Management System or Data Acquisition unit. Blue/Black Wire (Optional Data Logger Signal Ground): Connect to signal input(-) on Engine Management system or Data Acquisition Unit. Orange (Pro Control Output): Connect to the coil of a relay Violet/Black (Serial Ground): Connect to the ground pin of a PC or laptop serial port. Violet (Serial Out): Connect to the receive (RX) pin of a PC or laptop serial port. Red Fuse Black/Violet Blue 12 V Ignition Switch Violet Blue/Black Brown Black Throttle Case Data Logger Output Carb or Throttle Body Good Engine Ground Wide Open Throttle Switch (for WOT peak function)

Mounting Sensor The heated oxygen sensor comes with a stainless steel weld-in bung, plug, and wiring harness with a weather pack connector. The oxygen sensor should be installed as close to the cylinder head as is reasonably possible so that the sensor reaches operating temperature quickly. If long tube headers are used, the oxygen sensor should be installed in the collector. If cast iron manifold(s) or shorty headers are used, install the sensor in the pipe just below the manifold. In multi-bank applications mounting in the left or right side is acceptable. Turbocharged applications should have sensor installed 4-5" after turbo on the down pipe. Open header applications may require minimum length of 18 of EXH pipe after sensor for proper reading at idle abd part throttle. The Air / Fuel Ratio Monitor can be used with the following fuels. Fuels Stoichiometric Air / Fuel Ratio Unleaded Gasoline 14.7:1 Methanol 6.4:1 Ethanol 9.0:1 LPG (Propane) 15.5:1 CNG 17.2:1 E85 9.8 Auto Meter recommends welding supplied stainless steel bung with a TIG welder. Operation Guide NOTE: OK for use with Nitrous Oxide. NOTE: Stoichiometric Air / Fuel Ratio is the chemically correct ratio where theoretically all of the oxygen and all of the fuel are consumed. The mixture is neither rich or lean. 1. The exhaust pipe in front of the sensor should not contain any pockets, projections, protrusions, edges, flex-tubes etc. to avoid accumulation of condensation. A downwards slope of the pipe is recommended. If the exhaust pipe is parallel to the ground, the sensor must be installed in the top half of the pipe to avoid damage to due to condensation 2. Tightening torque: 30-44 ft Ibs. 3. Avoid excessive heating of the sensor cable. Route sensor cable away from exhaust pipe. 4. The maximum temperature of the sensor on the outside of the exhaust fitting should not exceed 900 o F. This product has many features that can be adjusted for your specific application. Use the MODE (-) and SELECT (+) buttons to navigate menu options, confirm selections, and fine tune options to your needs. Acronyms: A list of acronyms and abbreviations are defined below in order to help you more clearly understand the menu operations, functions, and components available on your Auto Meter Wideband Air/Fuel gauge: BGD Bar Graph Display. This is the curved, multi-color, LED radial display used to indicate how Rich or Lean the current Air Fuel or Lambda reading is relative to your Stoichiometric point with respect to your upper and lower range tolerances. SSD Seven Segment Display. This is the digital numeric display that indicates your current Air Fuel or Lambda reading. This display is also used to help you navigate and make changes to your settings. AFR Air / Fuel Ratio. This is shown as a numeric value on the SSD, characterized by only having a single decimal place (i.e. 14.7). This value is also visually represented on the BGD, indicating whether the value is Rich or Lean of the selected Stoiciometric value and relative to the upper and lower range tolerances. AFR, as the name implies, represents the ratio of Air to Fuel being mixed and consumed, in real time, by the engine / vehicle upon which this instrument has been installed. Lamda, is an alternate way of expressing AFR, assuming that the stoichiometric point selected equals one and readings rich or lean will be expressed as values above or below one, characterized by a value displayed with two decimal places, (i.e. 1.00). The gauge can display data in either AFR or Lambda as needed by the user. Real-Time Mode: Real-Time mode is the default mode of operation for this product. When Real-Time mode is active, the instrument will display the current air/fuel ratio in either AFR or Lambda. To toggle between AFR and Lambda display types, press the SELECT(+) button. Remember that AFR values have a single decimal place (i.e. 14.7), and that Lambda values have two decimal places (i.e. 1.00).

Menu Options: There are several other features provided by your Auto Meter Wideband Air/Fuel Ratio gauge. Use the MODE (-) button to navigate through the following options in order: Peak/Recall - SSD will display P Alarm/Warning - SSD will display ALr Pro Control - SSD will display PrC Stoichiometric - AFR Setting - SSD will display AFr BGD Range - SSD will display dsp Auto-Dim - SSD will display br Heater - SSD will display Htr Response - SSD will display rsp Firmware - SSD will display the firmware revision. Once the desired option is displayed on the gauge, press the SELECT(+) button to confirm your selection. Specific Menu options are outlined in the following section. If no selection is desired, you may continue to press MODE (-) until you return to Real-Time Mode or press neither button for 10 seconds and the gauge will return to Real-Time Mode on its own. Wide Open Throttle Peak/Recall Mode: WOT Peak/Recall mode provides you with a quick and easy way to find out exactly how Lean your engine / vehicle got during the last pull, run, or race. This value is recorded when the Brown Wire in the instrument harness is connected to a good engine ground via a normally open, momentary closed wide open throttle switch (not included, see wiring diagram) such as may be used with a Nitrous Oxide application. This allows peak readings to be sampled only during wide open throttle conditions. If the Air / Fuel Monitor gauge will not be used with a Wide Open Throttle switch, you may connect the brown wire permanently to a good engine ground to continuously monitor for peak conditions, or leave disconnected if peak lean is not needed. To View: From Real-Time Mode, press MODE (-) to scroll until the display indicates P, then press SELECT (+) to display your Peak. To Clear: When the Peak value is displayed, press SELECT (+) to clear your Peak value and return to Real-Time Mode. The SSD will display --- once the peak has been cleared and until a new peak value has been recorded. If neither button is pressed for 3 seconds after the Peak Value is displayed, the gauge will return to Real-Time Mode. Wide Open Throttle Alarm/Warning Mode: Alarm/Warning mode enables you to program a visual alert point into the gauge in order to warn you of when air/fuel mixtures are running dangerously lean in your vehicle s engine. The visual alarm or warning activates when the AFR or Lambda reading reaches or exceeds your programmed alarm point. When the alarm activates the BGD will blink rapidly to warn the driver of the Alarm condition. Similar to Peak/Recall Mode, this function only operates when the Brown wire is grounded via a normally open, momentary closed, wide open throttle switch (not included, see wiring diagram) such as may be wired with a Nitrous Oxide application. To View your current Alarm Point Setting: From Real-Time Mode, press MODE (-) to scroll until the display indicates ALr, then press SELECT (+) to display your current Alarm set point. To Change your Alarm Point Setting: When the current Alarm set point is displayed, press SELECT (+) to increase your alarm point setting, and MODE (-) to decrease your alarm point setting. After you have selected your new alarm set point, the gauge will flash your new set point 8 times on the display and then the SSD will display S C for Save/Cancel. To confirm your new alarm point setting, press MODE (-). This will save your Alarm set point changes and return the gauge to Real-Time mode. To cancel the changes and return to your previous set point, press SELECT (+). This will cancel the Alarm set point changes and the gauge will return to real time mode.

Stoichiometric AFR Setting Mode: The Stoichiometric AFR setting allows you to adjust the gauge scale for alternate fuel types such as Ethanol. As a default this product is set up for gasoline, with a stoichiometric AFR point of 14.7:1. If you would like to adjust this product for use on an alternate fuel type or would merely like to adjust the center point of your BGD, please follow the instructions below. To view your current Stoichiometric AFR setting: From Real-Time Mode, press MODE (-) to scroll until the display indicates AFr, then press SELECT (+) to display your current Stoichiometric set point. To Change your Stoichiometric AFR setting: When the current Stoichiometric set point is displayed, press SELECT (+) to increase your Stoichiometric AFR setting, and MODE (-) to decrease your Stoichiometric AFR setting. After you have selected your new Stoichiometric set point, the gauge will flash your new set point 8 times on the display and then the SSD will display S C for Save/Cancel. To confirm your new Stoichiometric setting, press MODE (-). This will save your Stoichiometric set point changes To cancel the changes and return to your previous set point, press SELECT (+). This will cancel the Stoichiometric set point changes Pro Control Setting Mode: The Pro Control setting allows you to adjust the AFR or lambda value that causes the Pro Control output to turn on. The Pro Control wire supplies ground when activated. It is recommended to use a relay switch such as the Dedenbear HPR or equivlant. If you would like to adjust this value, please follow the instructions below. To view your current Pro Control AFR setting: From Real-Time Mode, press MODE (-) to scroll until the display indicates PrC, then press SELECT (+) to display your current Pro Control set point. To Change your Pro Control setting: When the current Pro Control set point is displayed, press SELECT (+) to increase your Pro Control setting, and MODE (-) to decrease your Pro Control setting. After you have selected your new Pro Control set point, the gauge will flash your new set point 8 times on the display and then the SSD will display S C for Save/Cancel. To confirm your new setting, press MODE (-). This will save your Pro Control set point changes To cancel the changes and return to your previous set point, press SELECT (+). This will cancel the Pro Control set point changes Normally Closed Normally Open +12v 87A 87 85 Key on Power If battery power is used, this circuit may backfeed causing your gauge to stay on after power to gauge red wire is shut off. 30 86 Relay: Dedenbear Part # HPR ORANGE

BGD Range Setting Mode: The Bar Graph Display (BGD) Range Setting Mode allows you to fine tune the resolution of this instrument for your specific application. With upper and lower set point adjustability, you can set the BGD to utilize the exact range that the engine / vehicle operates within and see exactly how rich or lean you are running in relation to your current set up and tune. Adjusting your BGD limits also adjusts the scaling of the 0-5v data logger output supplied from the gauge. The selected low set point of the BGD Range becomes the 0v value of the data logger output. The selected high set point of the BGD Range becomes the 5v value of the data logger output. Whenever you change these points, the instrument adjusts the data logger output so that the 0-5v signal is always linear between your chosen set points. To view your current BGD Range HI / Lean setting or LO / Rich setting: From Real-Time Mode, press MODE (-) to scroll until the display indicates dsp, then press SELECT (+) to display your current BGD Range set point. The SSD of your display will show HI in the display to indicate that you will be viewing the above Stoichiometric or Lean upper range boundary. If you would like to view the LO / Rich setting, press MODE (-) when HI is shown on the SSD. The SSD should now indicate LO. When the desired setting, HI or LO, is displayed, confirm this selection by pressing SELECT (+). The upper or lower BGD range value will then be displayed in the SSD of your gauge corresponding to your selection. Note: When your selection is made and the numeric range value is shown, LEDs in the BGD will light to indicate which set point you are viewing. If the LEDs to the left of center or Stoichiometric are lit, you are viewing the LO or Rich set point. If the LEDs to the right of center or Stoichiometric are lit, you are viewing the HI or Lean set point. If neither button is pressed for 3 seconds after the BGD Range HI Setting is displayed, the gauge will return to Real-Time Mode. To Change your BGD Range setting: When the current BGD Range HI or LO set point is displayed, press SELECT (+) to increase your chosen BGD Range setting, and MODE (-) to decrease your BGD Range setting. After you have selected your new BGD Range set point, the gauge will flash your new set point 8 times on the display and then the SSD will display S C for Save/Cancel. To confirm your new BGD Range setting, press MODE (-). This will save your BGD Range set point changes To cancel the changes and return to your previous set point, press SELECT (+). This will cancel the BGD Range set point changes Data Logger Output Range: The Auto Meter Wideband Air / Fuel gauge has a signal output for supplying information to a Data Logger or engine management system. The signal provided is a linear 0-5v output. See the BGD Range Setting Mode for information about how to define the air/fuel mixture values for low (0v) and high (5v) ranges of the output in order to scale this linear signal output for best operation with your Data Logger or engine management. The formula to determine the AFR output from the voltage provided by the gauge is derived from y=mx+b (algebraic equation for a straight line), where in our needs the following applies: y = AFR m = slope of the plotted line (BGD AFR High - BGD AFR Low ) / (5v - 0v) x = output voltage from the gauge b = offset or AFR value at 0v Using the default values of 10:1 AFR for 0v and 16:1 AFR at 5v the formula looks like this: y = ((6/5) * v) + 10 or can be simplified as: y= 1.2*v+10 If we plug in 1.25v into that equation then we get: 11:5 AFR = (1.2*1.25) +10 which falls right along the plot chart. If you were to adjust the BGD endpoints to say 11:1 and 15:1 then the formula would be modified to look as follows: y = ((4/5)*v) +11 simplified to y = 0.8*v + 11

Auto-Dim Mode: This product incorporates an Auto-Dimming feature that allows it to adjust automatically for varying lighting conditions. This is accomplished with a sensor light embedded in the dial. You may enable or disable this feature depending upon your viewing preference. When Auto-Dim mode is disabled, the product and LED s operate at maximum brightness regardless of atmospheric lighting conditions. The auto-dim mode is set to off from the factory. To view your current Auto-Dim setting: From Real-Time Mode, press MODE (-) to scroll until the display indicates br for brightness, then press SELECT (+) to display your current Auto-Dim setting which will be indicated as either ON or OFF in the SSD. If neither button is pressed for 3 seconds after the Auto-Dim Setting is displayed, the gauge will return to Real-Time Mode. To Change your Auto-Dim setting: When the current Auto-Dim setting is displayed, press MODE (-) to toggle between On and OFF. When your new Auto -Dim setting is displayed, press SELECT (+) The gauge will flash your new setting 8 times on the display and then the SSD will display S C for Save/Cancel. To confirm your new auto dim settings, press MODE (-). This will save your Auto-Dim setting changes and return. To cancel the changes and return to your previous set point, press SELECT (+). This will cancel the Auto-Dim setting changes and return the gauge to Real-Time mode. Heater Control Mode: All O2 sensors must be heated before an accurate signal is produced. Potential sensor damage can occur if the gauge begins to heat the sensor before the engine is running due to condensation that forms on the sensor tip and in the exhaust. To accommodate this, an internal trigger within the gauge will automatically begin heating the sensor when 13.5 volts or higher is seen on the Red wire ( Normal operating mode). While the gauge does not require 13.5 volts to operate (12 volts will suffice), this voltage is used to indicate to the gauge that the engine is running, as most regulated charging systems will maintain 14 volts or higher. Once the gauge sees 13.5 volts the SSD will display htg. When the sensor is heated, the SSD will flash rdy and the gauge will begin reading air/fuel ratio in real-time. In applications where a standard charging system is not used (vehicles without a regulated alternator, for example) there is an override available that will allow sensor heating to occur without the gauge reading a 13.5 volt trigger. This can be accomplished while the seven-segment display shows (---) (thereby overriding Normal operating mode) or set to trigger when 12 volts is applied on the Red wire ( On operating mode). To Override Normal Operating Mode: While displaying (---), press any button to begin the heater process. To View your current Heater Operating Mode: From Real-Time Mode, press MODE (-) to scroll until the display indicates Htr, then press SELECT (+) to display your current Heater Operating Mode. If neither button is pressed for 3 seconds after the Heater Operating Mode is displayed, the gauge will return to Real-Time Mode. To Switch Between Heater Operating Modes: When the current heater operating mode is displayed (either Nor or On ), press SELECT (+) to choose the current setting or MODE (-) to switch to the alternate setting. nor = 13.5V trigger is active, on = 13.5v trigger is turned off. After you have selected your new Heater Operating Mode, the SSD will display S C for Save/Cancel. To confirm your new Heater Operating Mode, press MODE (-). This will save your current Heater Operating Mode and return the gauge to Real-Time mode. To cancel the changes and return to your previous Heater Operating Mode, press SELECT (+). This will cancel the Heater Operating Mode change NOTE: Even with 13.5v trigger deactivated gauge will still show htg after every power up while the sensor is heating. Response Setting Mode: The response setting allows you to choose how quickly the SSD abd BGD will change with varying AFR. FAST response is a high speed display update rate that allows you to see AFR changes as fast as they are happening, but this may make it difficult to read. SLOW response is a display update rate that is easier to read, and still fast enough to get useful information. To view your current Response setting: From Real-Time Mode, press MODE (-) to scroll until the display indicates rsp for response, then press SELECT (+) to display your current Response setting which will be indicated as either FSt or Slo in the SSD. If neither button is pressed for 3 seconds after the Response Setting is displayed, the gauge will return to Real-Time Mode. To Change your Response setting: When the current Response setting is displayed, press MODE (-) to toggle between FSt or Slo. When your new Auto -Dim setting is displayed, press SELECT (+) The gauge will flash your new setting 8 times on the display and then the SSD will display S C for Save/Cancel. To confirm your new auto dim settings, press MODE (-). This will save your Response setting changes and return. To cancel the changes and return to your previous set point, press SELECT (+). This will cancel the Response setting changes and return the gauge to Real-Time mode.

Warning Fouling and/or permanent damage to the oxygen sensor over time will result if used with any of the following: Green Leaded gasoline and fuel additives containing lead 2 cycle gasoline (gas/oil mix) Diesel Fuel Nitromethane Excessively rich mixtures If the Air/Fuel Ratio Monitor responds sluggish, the oxygen sensor is probably partially fouled and should be replaced. LED Chart Lean Range Eight red LED s Amber MODE SELECT - + Red Stoichiometric Range Rich Range Fourteen green LED s Eight amber LED s Serial Output The Auto Meter Pro Plus wideband has a serial output for supplying AFR or lambda to a PC, laptop, or other digital device. The device serial connection must be set to 9600 baud, 8 bits data, no parity, 1 stop bit, flow control -none. A terminal program will display the data as shown below. SERVICE For service send your product to Auto Meter in a well packed shipping carton. Please include a note explaining what the problem is along with your phone number. If you are sending product back for warranty adjustment, you must include a copy (or original) of your sales receipt from the place of purchase. 12 MONTH LIMITED WARRANTY Auto Meter Products, Inc. warrants to the consumer that this product will be free from defects in material and workmanship for a period of twelve (12) months from date of the original purchase. Products that fall within this 12 month warranty period will be repaired or replaced at Auto Meter s option to the consumer, when it is determined by Auto Meter Products, Inc. that the product failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of parts in the Auto Meter instruments. In no event shall this warranty exceed the original purchase price of the Auto Meter instruments nor shall Auto Meter Products, Inc. be responsible for special, incidental or consequential damages or costs incurred due to the failure of this product. Warranty claims to Auto Meter must be transpotation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in duration to the said 12 month warranty period. Breaking the instrument seal, improper use or installation, accident, water damage, abuse, unauthorized repairs or alterations voids this warranty. Auto Meter Products, Inc. disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by Auto Meter. FOR SERVICE SEND TO: AUTO METER PRODUCTS, INC. 413 W. Elm St., Sycamore, IL 60178 (866) 248-6357 For Email: Service@autometer.com The Super Bezel is a registered trademark of Auto Meter Products, Inc. 2015 Auto Meter Products. Inc. 2650-1128-77 5/21/15