CONTENTS 1.0 INTRODUCTION SAFETY... 5

Similar documents
Seed-Squirter. Installation Guide. APPLICATION SYSTEMS FOR PROFESSIONALS. How Can We Help?

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Quick Setup Guide for IntelliAg Model YP Twin Row

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Quick Setup Guide for IntelliAg Model YP

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter.

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Reference Manual /12

Seed Rate Charts for the YP1225 or YP1625 Planters

SharpShooter With Rate Sync for Turf

Installation Instructions ISOBUS Liquid ECU

Troubleshooting Guide

Troubleshooting Guide

ROW PRO DOWN PRESSURE

844-E Sprayer Control. Installation, Programming and Operating

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

Manufacturing, Inc.

Technical Training GEN I

Model No. LG55-3PT 55 Gallon Sprayer 3 Point Lawn & Garden Sprayer Model No. LG27-3PT 25 Gallon Sprayer GENERAL INFORMATION

ADJUSTMENTS BEFORE GOING TO THE FIELD

Owner's Manual. Model: 150 GAL-3PT ( ) (150 Gallon, 3-Point Sprayer, Boom-Ready) Information About The Sprayer. Assembly Instructions

Spray Height Controller

OWNER S MANUAL. Model: LG-25-BL-QR ( ) (25 Gallon ATV Dual Nozzle Sprayer) ***IMPORTANT REMINDER*** Technical Specifications

MODEL NO. LG Volt Lawn & Garden Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

Model: 110-3PT LESS BOOM ( ) (110 gallon 3-point carrier with NO boom)

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

WORKHORSE. Assembly / Operation Instructions / Parts

Owner's Manual. Model: ATVBK-710 ( ) (7-Nozzle Deluxe Boom Assembly w/connecting Fittings) Technical Specifications.

Seed and Fertilizer Rate Charts for the YP3025A, YP4025A and YP4425A 30, 40 and 44-Foot 3-Section Yield-Pro Planters with Air-Pro seed meters

& Tower for PWM Control. Maximum Application Rates with Two 5.3 GPM Electric Pumps

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

400 INSTALLATION & OPERATION INSTRUCTIONS

Owner's Manual. Model: ATVBK-710 ( ) (7-Nozzle Deluxe Boom Assembly w/brackets & Connecting Fittings) Technical Specifications.

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

Owner's Manual. Model: ATVBK-3025 ( ) (Boomless Nozzle Kit for ATV Mounting) Technical Specifications. Assembly. General Information

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

Model: ATVTS-60-12V 60 Gallon Trailer Sprayer W/7 Nozzle Boom ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Calibrating Chemical Application Equipment

Liquid Ready System T-Band / In-Furrow

Y1. Troubleshooting / Service Guide for SureFire PWM Liquid Application Systems. SureFire Commander II Controller

factsheet Field Sprayer Calibration Introduction Pre-Calibration Checklist Using a Calibration Bottle

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

2013 SP Sprayer Clinic

MODEL NO. ATVBK NOZZLE BOOM ASSEMBLY FOR ATV MOUNTING ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

Owner's Manual. Model: LG-40-3PT-12V ( ) (40 Gallon, 12 Volt, 3 Point Sprayer w/7-nozzle Boom Assembly) Technical Specifications.

SCS 340 INSTALLATION AND SERVICE MANUAL

SCS 440 SERIAL INTERFACE INSTALLATION AND SERVICE MANUAL

Matrix Pro GS. Setup Guide. For use with software version 3.0x. TeeJet Aabybro Mølhavevej 2 DK 9440 Aabybro Danmark

Owner s Manual. MG2000 Speedometer IS0211. for use with SmartCraft Tachometer

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

834 Sprayer Control L2.12 User Guide R1

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

OWS OPERATIONS & MAINTENANCE

Maximum Application Rates with Two 5.3 GPM Electric Pumps

ECLIPSE Laundry Dispenser Controller

MODEL NO. UTL-60-7

Tracer VM with User Interface

Module 13 Rate-controller functions and settings Getting the best out of the functions available

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Use an ink pen when completing entries in this document. Contact the manufacturing or engineering project managers with any questions.

LG-60-3PT-WP-309-BL-TSC

Level-Up Motorhome Leveling

DeltaForce System Operation

Installation & Service Manual

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

CSI-400 Installation Instructions

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

MoistureMatch A next generation grain tester

Section 35 Chapter 9

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

TR 300 ECONOMY TRAILER SPRAYER HAMILTON # 20, BOOMJET #10, BOOM XT & 8 ROW BOOM HYPRO 8 ROLLER PUMP

Intelliview II CX/CR Combines software framework 12

OWNER S MANUAL. Model: ATV ( ) ***IMPORTANT REMINDER*** Technical Specifications. Assembly Instructions. General Information

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

200 & 300 Gallon 3 Point w/5880 Nozzle ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

Owner's Manual. Model: ATV ( ) (25 Gallon Lawn & Garden/ATV Sprayer w/standard 7-Nozzle Boom Assembly) Technical Specifications.

AQUIS Foam System. Installation, Operation, and Maintenance Instructions AQUIS 1.5, AQUIS 3.0, and AQUIS 6.0

Ph: (07) Fax: (07) Pump Manual

Tracer VMA with AutoReg

Raven RS1 Guidance and Steering Calibration & Operation Manual. P/N Rev. A 09/17 E29677

AccuMax 3060 Multi-Point Detailed Specifications

Owner's Manual. (20 Gallon Lawn & Garden Trailer Sprayer) Technical Specifications. Assembly. General Information. Warranty/Parts/Service

PowerView PV380-R2 Mechanical Configuration

WORKHORSE. Assembly / Operation Instructions / Parts

ADJUSTMENTS BEFORE GOING TO THE FIELD

*Please Note* All Instructions, Manuals, Extra Orifices, Adjustment Tools, Setting Charts, Etc. MUST BE GIVEN TO END USER!

Owner's Manual. Model: UTL-60-12V ( ) (60 Gallon Utility Sprayer w/ 5-Nozzle Boom Assembly) Technical Specifications.

Transcription:

Contents CONTENTS 1.0 INTRODUCTION........................... 3 2.0 SAFETY.................................. 5 3.0 SETUP................................... 7 AccuShot System Screen ICON Description..... 7 HOME Screen.............................. 8 PLACEMENT Settings....................... 9 Procedure for Setting Liquid Bypass for AccuShot. 10 Initial Setup............................... 11 Close Main Bypass Valve.................... 12 Open Boom Shutoff Valve.................... 12 Activate Pump............................. 13 Pressure Relief Valve Adjustment.............. 14 Pressure Gauge........................... 15 DIAGNOSTICS SYSTEM Screen.............. 17 Activate the Key FOB Controls................ 19 Operate the Key FOB Controls................ 20 Purge Operation........................... 21 Operate the System Info Screen............... 22 Valve Diagnostics.......................... 24 TIP CALIBRATION Catch Test................ 25 Tank Volume.............................. 29 SENSOR SETTINGS - Factory Set............. 30 PUMP Settings - Factory Set................. 32 4.0 FIELD OPERATION........................ 35 AUTO Mode.............................. 35 Field Verify Seed and Shot Placement.......... 36 MANUAL Mode............................ 39 ON Mode................................. 42 Active Seed / Valve Sensor Indicators.......... 44 OFF Mode................................ 45 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 1

Contents System Control - Run / Hold.................. 46 2 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

1.0 - Introduction 1.0 INTRODUCTION The AccuShot liquid delivery system is designed to apply a specific amount of liquid product at a specific location relative to each seed in the furrow. The correct amount of liquid product can now be delivered where the seed needs it...giving each seed a better shot at germination. Application Based To reduce seed burn and improve stand counts, the Operator supplies initial setup information via a VT Display so AccuShot can determine how close to the seed to apply the liquid product. By concentrating the liquid product where the seed needs it, AccuShot reduces wasted product between the seeds at wider seed spacings. Results Improved plant vigor and less wasted liquid product both drive more profit to the Producer s bottom line with AccuShot. Other Manuals The AccuShot Quick Start Guide is for use with the companion AccuShot Operator and Maintenance Manual. 2015 CAPSTAN AG SYSTEMS, INC., All rights reserved. Capstan Ag Systems, Inc. shall retain sole ownership of Copyrights and Patents for the technology found in AccuShot; along with all documentation, which shall not be copied, in whole or in part, adapted, modified, or disseminated without written permission from Capstan Ag Systems, Inc. This equipment is an agricultural-based system operated by a trained operator and maintained by qualified personnel. Patented operational software, circuitry logic and processes supplied on each AccuShot product remain the exclusive property of Capstan Ag Systems, Inc. is a trademark of Great Plains, Inc. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 3

1.0 - Introduction THIS PAGE IS INTENTIONALLY LEFT BLANK 4 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

2.0 Safety 2.0 SAFETY This manual contains important information on how to safely, efficiently and correctly operate the AccuShot System. Following these instructions will help keep personnel safe, reduce downtime and increase the reliability and life of the equipment, its components and related systems. Review the Safety Information in the applicable tractor, planter and ancilliary equipment manual(s). Follow the instructions (in this manual) for each step thoroughly to ensure safe work conditions in and around the applicable tractor, planter and ancilliary equipment manual(s). It is important for all individuals working with chemicals to understand the potential risks, necessary safety precautions and proper response in the event of accidental contact. Review the applicable tractor, planter and ancilliary equipment manual(s) for chemical safety information. Review and understand procedures for obtaining and using Safety Data Sheets (SDS)and the required Personal Protective Equipment(PPE) for when working around hazardous chemicals and sharp edges and objects on applicable tractor, planter and ancillary equipment. Use the procedure in the appropriate Agricultural Equipment Manual for connecting, disconnecting and jump starting the machine s battery. Please keep this manual and all enclosed documentation in an accessible location known to all operator personnel. Keep sparks and flames away from the battery. Battery gas can explode and cause serious injury. Do not smoke in battery charging area. Make certain that all personnel have read this manual and thoroughly understand safe operating procedures. If you do not understand the AccuShot equipment after reading this manual, please obtain the proper training before working with the AccuShot system to ensure your own safety and well as your co-worker s safety. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 5

2.0 Safety THIS PAGE IS INTENTIONALLY LEFT BLANK 6 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

3.0 SETUP AccuShot System Screen ICON Description Icon Icon Descriptions - LH Side of Monitor Touch this icon to activate the AccuShot system. Icon Icon Descriptions - RH Side of Monitor The Alarm icon appears when there is an alarm in the system. Touch this icon to view and silence current alarms. Touch this icon to return to the Home Screen. Touch this icon to open the Placement Settings Screen. Touch this icon to open the Tip Calibration Screen. Touch this icon to open the Diagnostics Screen. Touch this icon to open the Tank Volume Screen. Touch this icon to open the Active Seed/Valve Sensor Screen. Touch this icon to go to the Next Page of icons. Touch this icon to open the Sensor Settings Screen. Touch this icon to open the Pump Settings Screen. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 7

HOME Screen The HOME Screen is the main user interface that provides central control of the AccuShot system. Icon Description Touch the <Home> icon to view Ground Speed, System Pressure, Tank Volume and Rate values on the HOME Screen. Touch and toggle <Mode> and <System Control> functions to operate the AccuShot system. 1 2 3 4 5 6 Mode <Toggle> OFF AUTO MAN ON operating functions. System Control <Toggle> RUN HOLD operating functions. Ground Speed display box System Pressure display box Tank Volume display box Rate display box 1 2 6 3 5 4 8 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

PLACEMENT Settings Use the PLACEMENT SETTINGS Screen to enter / edit the placement and location of the shot in relation to the location of the seed. Icon Description Touch the <Seed Droplet> icon to set Population, number of Planter Rows, Planter Width, Application Rate, System Pressure, Target Speed, and shot Distance from the seed. Settings Defaults Units of Measure Population 32.0 Thousand (k) Seed per Acre Number of Rows 32 Planter Width 480 Inch Application Rate 5.0 Gallon per Acre Pressure Set Point 30.0 PSI Target Speed 5.0 MPH Dist. From Seed 1.0 Inch Squirt Length 1.7 Inch A warning will appear on the PLACEMENT SETTINGS Screen when Operator-entered values may not match or align with other settings. Read the warning and touch <Accept>, <Cancel> or <OK> to continue. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 9

Procedure for Setting Liquid Bypass for AccuShot When the add-on hydraulically-driven centrifugal pump must run at different operating points on the AccuShot system, a liquid product bypass line(s) is (are) used to return some of the liquid back to the liquid product tank(s). This allows the pump to operate efficiently and reliably at its best efficiency point. If the pumped liquid product was returned through the suction line connections, turbulences at the pump suction would cause operational problems and even equipment damage. AccuShot uses a Main Bypass Valve near the product pump and a Liquid Product Shutoff Valve on the lower backside of each liquid product tank to manage different operating points. A total of up to 5.5 GPM of hydraulic flow is needed to operate the AccuShot system. 3 1 2 10 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Initial Setup 1. Fill liquid product tank(s). 2. Verify that the Tank Supply Valve(s) is/are open. 3. Verify that the Liquid Product Shutoff Valve(s), being used for Accu- Shot, is/are open on the back of the liquid product tank(s). 5 4 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 11

Close Main Bypass Valve 4. Close the main bypass valve (near the product pump) on the Planter. Closing Main Bypass Valve 1 Open Boom Shutoff Valve 5. Open shutoff valve to booms on the liquid product line. 6. Start the Tractor. 7. Engage the Planter Hydraulics Opening Boom Shutoff Valve 1 12 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Activate Pump Icon Description On the HOME Screen: Touch the red <Diagnostic> icon on the right hand side of the HOME Screen. 8. Touch the red Key FOB Mode button on the DIAGNOSTIC Screen (the button will turn green and the function buttons will appear). 9. Start the liquid product pump by touching the pump <ON/OFF> button on the DIAGNOSTIC Screen or by pressing the button on the Key FOB. Activate Pump 1 1 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 13

Pressure Relief Valve Adjustment 10. While viewing the manual pressure gauge at the liquid product pump, adjust the pressure relief valve to set the pressure at 70 PSI maximum. Rotate CCW to decrease pressure. Rotate CW to increase pressure. 11. Once pressure is set, use the locknut to lock the setting in place. 1 2 12. Open the main bypass valve (near the product pump) to the 10 o clock position. 14 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Pressure Gauge 13. While viewing the manual pressure gauge on planter, verify the pressure is 60 PSI. If not 60 PSI, do the following steps: a. Under 60 PSI i. Increase hydraulic flow to the planter hydraulics until 60 PSI is reached on the manual pressure gauge on the planter. 1. If hydraulics cannot get the pressure to 60 PSI, close main bypass valve till pressure reaches 60 PSI. (Some bypass is needed for better AccuShot operation.) 1 b. Above 60 PSI 2. If pressure does not reach 60 PSI with main bypass fully closed, tractor hydraulic supply is not sufficient. Contact your Planter dealer for further assistance. i. Decrease hydraulic flow to the planter hydraulics until 60 PSI is reached on the manual pressure gauge on the planter. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 15

14. Shut off the product pump by touching the pump on/off button on the screen or Key FOB. 15. The bypass valve should be set at the correct pressure and flow after performing the above steps. Recheck pressure gauge on planter to verify. Minor hydraulic pump adjustment might be required when planting. See PUMP Settings - Factory Set on page 32. 16 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

DIAGNOSTICS SYSTEM Screen Icon Description Touch the red Diagnostics icon to view the DIAGNOSTIC Screen. Select and toggle any of the red buttons on the Diagnostics Screen. This screen allows Key FOB use, viewing System Info and running Valve Diagnostics. The selected button will turn green when activated. Make sure the <Mode> button on the HOME Screen reads OFF to use the Key FOB and view diagnostics. Procedure The Operator can perform the following functions on the DIAGNOSTIC Screen: 1. Enable Test Speed and/or Test Pressure for diagnostics and troubleshooting. 2. Activate Key FOB operation. 3. View System Info. 4. Running valve diagnostics. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 17

Procedure Touch to toggle any of the red buttons on the DIAGNOSTIC screen. The toggled button will turn green when activated. When a Test Speed and/or Test Pressure procedure is enabled for troubleshooting and diagnostics, TEST will blink on the following two menu screens: HOME Screen in the center of the Speed and/or Pressure display boxes. TIP CALIBRATION Screen in the System Pressure box at the bottom of the screen. Both Test Speed and Test Pressure values can be edited (one at a time) from the DIAGNOSTIC Screen, by touching inside the value display box to activate the keypad. Once a number is selected, touch the key to enter the chosen number. 18 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Activate the Key FOB Controls Icon Description Touch the red <Diagnostics> icon. Procedure Touch the red <Keyfob Mode> button on the DIAGNOS- TIC Screen to display the Key FOB function buttons. Key FOB Mode Active will blink on the DIAGNOSTIC Screen and the red button will turn green. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 19

Operate the Key FOB Controls Icon Description 1 2 3 4 Pulse Nozzles Right to Left. Turn Pump ON/OFF. Pulse Nozzles Left to Right. Repeat Current Nozzle Pulse. NOTE: Button has a dual function. During Tip Calibration, it is used to Start/Stop the Tip Calibration Catch Test. Procedure Operator can also use the Key FOB or the AccuShot DIAGNOSTIC Screen in the Cab to clear any plugged rows, remove air from the system, and test row-by-row to ensure that all rows are still working properly. The row number being tested can be edited from the DIAGNOSTIC Screen with Key FOB Controls activated. Touch the inside of the Now Testing Row display box to enable the keypad. Touch / edit the row number being tested. Touch the key to enter the value. If the <Mode> is not set to OFF on the HOME Screen, a warning will appear when enabling Key FOB Mode. 20 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Purge Operation The Operator can prime, purge the air or flush the AccuShot plumbing system from the DIAGNOSTIC Screen with the Key FOB Mode activated. At the start of every planting day, an Operator should (at the very least) run the Purge All Valves operation to check the system for air or contamination. Icon Description To perform the Purge Operation, the VT Display must be on the DIAGNOSTIC Screen with no active warnings. (Read / Review Section 3.4 in the AccuShot Operator and Maintenance Manual. Make sure the Key FOB Controls are activated and dis-plays a green <Keyfob Mode> button. Procedure Touch the red <Purge All Valves> button to start purge operation. The red <Purge All Valves> button will turn green and all nozzle valves will open 100%, allowing a constant liquid flow from the product tank, through the plumbing system and discharging through the nozzle valves. Purge will end when touching the green <Purging Valves> button, pressing any of the top 4 Key FOB buttons or touching the Key FOB buttons on the DIAGNOSTIC Screen, or leaving the DIAGNOSTIC Screen. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 21

Operate the System Info Screen Icon Description Touch the <System Info> button to display more information. The button will turn green when enabled. Operator can view System Voltage, Hour Meter, Pressure Sensor Voltage, Pump Duty Cycle, and GPS readouts. 22 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Touch the SW Versions button to view the AccuShot Controller s circuit board information. Circuit Board Information AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 23

Valve Diagnostics Icon Description Touch the red <Diagnostics> icon on the HOME Screen. Touch the <Valve Diag> button. The button will turn green. The Operator can see if all nozzle valves and seed sensors are connected. Icon Indicator Color Key Indicates seed sensor and nozzle valves are connected. Indicates nozzle valve is connected while seed sensor is not being detected by controller. Indicates seed sensor is connected while the nozzle valve is not being detected by controller. See the AccuShot Operator and Maintenance Manual for more diagnostic help, if needed. If the <Mode> is not set to OFF on the HOME Screen, a warning will appear when enabling Valve Diagnostics. 24 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

TIP CALIBRATION Catch Test Icon Description The TIP CALIBRATION Screen is used to compensate for different viscosities and fluid dynamics. 1. Touch the <Tip Calibration> icon on the HOME Screen. 2. Verify and edit Tip Calibration information as needed. Changing values on the TIP CALIBRATION Screen will also change the same values in the PLACEMENT SETTINGS Screen or vice versa. Verify that the Tip Size is correct. Spray Tip size is verified by looking at the outside surface of the tip near the spray end. Procedure 3. Place the Calibration Pitcher directly underneath a spray nozzle on Row #1 of the Planter. 4. With the planter hydraulics engaged, touch the <START> button on the TIP CALIBRATION Screen or press button 4 on the Key FOB to begin the Tip Calibration Catch Test. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 25

You can START and STOP testing as needed using the TIP CALIBRATION Screen or Key FOB. 4 26 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

5. Once the test is complete and liquid product is captured: Read the Calibration Pitcher at the bottom of the meniscus. Reading the Calibration Pitcher at or above the meniscus will cause an inaccurate GPA measurement. 6. Touch the inside of the <CAPTURED Volume> box. A keypad will appear. Enter amount of fluid caught. Touch the key to enter the amount. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 27

7. Once a CAPTURED Volume is entered, Touch or A new Product 1 Cal% will be calculated. Touch <Accept> to select new value or <Decline> to return to previous Product 1 Cac%. 8. Repeat Catch Test until the correct catch volume is caught. If the <Mode> is not set to OFF on the HOME Screen, a warning will appear when accessing the TIP CALIBRATION Screen. 28 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Tank Volume The TANK VOLUME Screen can also be accessed by touching the <Tank> volume box on the HOME Screen. Icon Description Touch the <Tank> icon to view and set the Tank Volume and set the Warning Level. Touching the <Tank> volume box on the HOME Screen opens the TANK INVENTORY Screen. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 29

SENSOR SETTINGS - Factory Set All settings are locked on this screen except the Flowmeter Cal. Locked screens are intended only for qualified Service Technician access and use. The Flowmeter Cal value entered must match the Flowmeter (label) on the Planter. The Flowmeter Cal Value IS NOT locked and must be set by operator. Icon Description The default Sensor Settings are set at the factory. Touch the LOCK icon to open the on-screen keyboard. 30 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Type in the password and touch the key to enter the password and UNLOCK the screen. Defaults 1. Pressure Sensor Voltage Low = 0.5 VDC 2. Pressure Sensor Voltage High = 5.0 VDC 3. Pressure Sensor Low = 0.0 PSI 4. Pressure Sensor High = 100.0 PSI 5. Radar Cal = 60.0 Pulse per 400 ft. 6. Row Fail Rate = 1 Seeds per sec. 7. Flowmeter Cal = 1740 Pulse per 10 Gals. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 31

PUMP Settings - Factory Set All settings are locked on this screen. Locked screens are intended only for qualified Service Technician access and use. Procedure After UNLOCK Adjust Hydraulic pump settings by using the System Gain setting to tune a system where the pressure is oscillating or sluggish to respond. Select a lower number to stabilize an oscillating system. Select a higher number to speed up a sluggish system. Icon Description The default Pump Settings are set at the factory. Touch the LOCK icon to open the on-screen keyboard. Type in the password and touch the key to enter the password and UNLOCK the screen. 32 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

Settings Default Units of Measure P 5 N/A I 2 N/A D 0 N/A System Gain 4 N/A Flow Meter Filter 5.0 Sec. Pressure Sensor Filter 2.0 Sec. Min Duty Cycle 20 N/A Max Duty Cycle 55 N/A AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 33

THIS PAGE IS INTENTIONALLY LEFT BLANK 34 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

4.0 Field Operation 4.0 FIELD OPERATION AUTO Mode Icon Description On the HOME Screen: Press <Mode> button and toggle to AUTO. In <Auto> mode, the system automatically adjusts the pressure, and activates the nozzle valves when seeds are sensed. This mode should be used for normal field operation. Press <System Control> button and toggle to RUN. With the planter hydraulics engaged, the liquid product pump will turn on and raise the pressure to the pressure set point. Touch and toggle <System Control> button to HOLD. Pump will shut OFF and nozzle valves will not pulse. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 35

4.0 Field Operation Field Verify Seed and Shot Placement A field check should be completed at the initial trip to the field and again whenever the distance to the seed is changed. See Chapter 4.0 in the AccuShot Operator and Maintenance Guide for detail images of this procedure. To perform the seed and shot placement check, complete the following steps: 1. On the AccuShot HOME Screen, touch and toggle <System Control> button to select HOLD. 2. At the back of the planter, using tie-down straps, secure up the closing wheels and shallow up the Side Gauge Wheel depth on the rows to be checked. (Recommend on a twin row to perform check procedures on rows next to each other. i.e. row 1 and 2). 3. Using the excess from the tie-down strap, or using a bungee strap, hold the seed firmer out of the furrow. 36 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

4.0 Field Operation 4. Once everything is out of the furrow and off the dirt and secured, return to the tractor cab. On the AccuShot HOME Screen, touch and toggle <System Control> button to select RUN. Resume planting for the desired test distance, using the same settings and speeds as normal planting. 5. Stop the tractor once test distance is reached. On the AccuShot HOME Screen, touch and toggle <System Control> button to select HOLD. Visually verify placement of shot relative to seed in the furrow. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 37

4.0 Field Operation 6. When placement of the shot relative to the seed is correct, remove all straps and readjust the Side Gauge Wheel depth back to normal operating depth. (See the manufacturer s specific planter manual for assistance. Repeat field check periodically or when Rate and/or Distance to Seed is modified. a. If placement needs adjustment, change Distance to the Seed value on the PLACEMENT SETTINGS Screen. b. Repeat field test to verify correct placement of shot relative to seed. 38 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

4.0 Field Operation MANUAL Mode Manual Mode is used for troubleshooting or continuing to run when a pressure sensor has failed. Icon Description Touch the red Diagnostic icon to view the DIAG- NOSTIC Screen. Touch to toggle the <Test Pressure> button to ENABLE the Test Pressure. Verify Test Pressure value is correct. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 39

4.0 Field Operation To edit the <Test Pressure> value if not correct, touch the pressure value box to enable the keypad. Upon enabling a <Test Pressure>, TEST will blink in the System Pressure box on the HOME and TIP CALIBRATION Screens. 40 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

4.0 Field Operation On the HOME Screen: Touch and toggle <Mode> button to select MAN. Touch and toggle <System Control> button to RUN. Visually monitor the manual pressure gauge on the Planter. % DC 3 4 Touch the % DC <Arrows> to INCREASE or DECREASE until the desired pressure is reached on the manual pressure gauge. Touch and toggle <System Control> button to HOLD. Pump will shut OFF and nozzle valves will not pulse. Pressure should be checked and readjusted once the planter is operating. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 41

4.0 Field Operation ON Mode Use ON mode to apply a constant stream of product. Orifice inserts will be required to achieve the desired GPA. (Use orifice rate charts to size the orifices correctly, or contact your local dealer.) The system automatically adjusts to maintain the pressure set-point. This pressure Set Point can be changed on the Placement Settings Screen. Icon Description Install Orifice Plates when running in ON Mode only. Remove orifice plates if wanting to run in Auto or Manual Mode. On the HOME Screen: Touch and toggle <Mode> button to select ON. Touch and toggle <System Control> button to select RUN. 42 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

4.0 Field Operation Touch and toggle <System Control> button to HOLD. Pump will shut OFF and nozzle valves will not pulse. Place <System Control> in HOLD Mode when picking up the planter on turns to prevent liquid product waste. Pressure Set Point can be changed from the HOME Screen by touching inside the Pressure box to enable the keypad. Once a number is entered, touch the key to accept the value. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 43

4.0 Field Operation Active Seed / Valve Sensor Indicators Use this screen to verify the nozzle valves and seed sensors are working correctly while the planter is operating. Icon Description Touch the <Heart> icon to verify all rows are working in the Active Seed/Valve Sensor Screen. See troubleshooting for help with failed rows. Icon Key to Indicator Colors Indicates seed sensor and nozzle valves are connected. Indicates seed sensor is not being detected by the AccuShot controller, while the nozzle valve is operational. Indicates nozzle valve is not being detected by the AccuShot controller while the seed sensor is operational. 44 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016

4.0 Field Operation OFF Mode Icon Description When the Mode is switched to OFF, the system shuts down (pump and nozzle valves), and all alarms are deactivated. Choose the OFF Mode when the liquid product system is not being used. Touch and toggle <Mode> button to select OFF. System Control defaults to HOLD when the <Mode> button is toggled. AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016 45

4.0 Field Operation System Control - Run / Hold Manual Mode is used for troubleshooting or continuing to run when a pressure sensor has failed. Icon Description On the HOME Screen: With hydraulics engaged, touch and toggle <System Control> button to select RUN. The liquid product pump will turn on and raise the pressure to the pressure set point. Touch and toggle <System Control> button to HOLD. Pump will shut OFF and nozzle valves will not pulse. 46 AccuShot 2015 Capstan Ag Systems, Inc. Version: P-2.0 2/5/2016