Accessories guide DHP-R

Similar documents
HERZ-Motorised flow controler

COMPONENTS FOR SOLAR THERMAL SYSTEMS

2-position electric actuators with Ball valves VBZ ½...11/4

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

3 & 4-Way Rotary Valves

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

COMPONENTS FOR SOLAR THERMAL SYSTEMS

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Produkt informatie COSTER T.E.

Air-to-water heat pump for indoor installation - LIK 8TES. Spare parts list

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

DM-TR. series 10 RADIAL DRIVEN TOOL SYSTEM WITH DIRECT MOTOR TURRETS (PATENTED) TECHNICAL INFORMATION I.T ISSUED 09-11

ROTARY MOTORIZED VALVES ROTARY MOTORIZED VALVES

Series description: Wilo-Stratos

Zone Valves and Parts (Honeywell)

Accessories. Series REC

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

CONTINUOUS 3520 ekw 4400 kva 50 Hz 1000 rpm

Pump Stations for Heating Circuits

PRIME 3880 ekw 4850 kva 50 Hz 1000 rpm

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

VE-S_15-32 Pressure Independent Balancing & Control Valves

Valves, controls + systems Stations for the connection heat generator/heating circuit

STANDBY 2860 ekw 3575 kva 50 Hz 1000 rpm

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Product range Solex Technical data and dimensioning. 5 Years

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

Components for central heating

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

30GX AIR-COOLED LIQUID CHILLER

Modulating control valve PN16

30GX AIR-COOLED LIQUID CHILLER

Controller Specification Sheet

Air Handling Units. Geniox. Accessories

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Products for underfloor heating

Diaphragm Valve, Plastic

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

FlowCon SM mm. Dynamic Self Balancing Control Valve SPECIFICATIONS

VICTRIX PRO Wall-hung modular condensing boiler for heating only

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

VE VVG Series Electronic Two-way Valves Normally Closed

technical brochure 3-/4-WAY ROTARY MIXING VALVES ARV ProClick ELECTRIC ACTUATORS ARM ProClick

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

Modulating control valve PN16 with magnetic actuator

LAUDA Variocool. Numerous options, compact design, easy operation

ROTARY MOTORIZED VALVES

LF Series Spring Return Direct Coupled Actuator

Diaphragm Valve, Metal

VALVES WITH SA03 ELECTRIC ACTUATOR

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Compressed Air-Supply Meter

GEMÜ 549 esydrive Motorized globe valve

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Küba SG industrial

TA-6-way valve. Standard control valves 6-way valve for change-over systems

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

SAP E & C PLC PROGRAMMING TRAINER KIT (PRODUCT CODE: PCST 14)

502 VALVE WITH UM ELECTRIC ACTUATOR

Two-port seat valves with male thread, PN16

Pendulum valve control system Series 65

Electric actuators type EA25-250

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Premounted Midi Shunts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Accessories STRA Room Controller

GEMÜ 539 esydrive Motorized globe valve

System components for sample gas sampling

Modulating control valve PN16 with magnetic actuator

K35 HeatBloC with 3-temperature mixing valve

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

130 KW / 165 KVA POWERED by

HEAT TREATMENT EQUIPMENT & ACCESSORIES

General 4-stroke direct injected, turbocharged and aftercooled diesel engine

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

DIESEL GENERATOR SET MTU 16V4000 DS2500

Immersion chillers E 01

INDEX HUMIDIFER 6. AH Series. BH Series. WH Series

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

Pressure Independent Control Valve

Heating, air-conditioning, cooling

ESBE Series 90 Electronic Motor Actuator (Combined with ESBE 3&4-Way Rotary Valves)

Transcription:

Accessories guide DHPR Expansion Module HPC EM, Water Charge System Function... 2 Expansion Module HPC EM, Tap Water Control Function... 3 Expansion module HPC EM, Shunt Function... 4 Cooling module HPC CM... 5 Strap on Sensor with Connection Box PT1000... 7 Submersible sensor PT1000... 9 Modular cables.... 11 Flow Guard Kit.... 12 Switching Valve for Hot Water, DHPR... 13 Hot Gas Circuit Circulation Pump Kit... 14 Room Sensor... 15 Dew Point Sensor... 16 Web Access... 17 Router for Web Access... 18 Soft Start.... 19 Electronic Valve Actuator SQS 65.5... 20 Valve Actuator ESBE... 22 Shunt valves ESBE... 24 Flow Adjustment Valve for hot gas circuit... 27 VKBMA302

Expansion Module HPC EM, Water Charge System Function Abelko 086U3395 The expansion module in WCS function mode manages hot water charging for the hot water heaters. The WCS function is achieved by moving the switch according to the figure to the side. Heating circuit Heat exchanger Submersible sensor return VVX Control valve Circulation pump CW HW HWC Expansion module WCS function WH WH WH WH Modular cable Brine circuit DHPR Hot gas circuit Accompanying accessories Submersible sensor return VVX, ThermokonDanelko AKF1004140, part no. 086U3364 One of the following modular cables: Modular cable 0.3 m, part no. 086U4227 Modular cable 1.1 m, part no. 086U4228 Modular cable 10.0 m, part no. 086U4229 Electrical connection WCS Temperature input, T1: Submersible sensor, return VVX Temperature input, T2: Analogue output 010V, AO1: Signal to control valve Relay, DO1: Signal to circulation pump, (potential free connection, max 6A) Control valve VVL (2way), heat exchanger (tap water exchanger), circulation pump. 2 VKBMA302 Accessories guide

Expansion Module HPC EM, Tap Water Control Function Abelko 086U3395 The expansion module in TWC function mode ensures that outgoing tap water and hot water circulation maintain sufficiently high temperatures to prevent legionella bacteria. The TWC function is achieved by moving the switch according to the figure to the side. Heating circuit CW HW Sensor HW heater HWC Expansion module TWC function Sensor HW return WH WH WH WH Modular cable Brine circuit DHPR Hot gas circuit Immersion heater Accompanying accessories 2 x PT1000 strap on sensors with 2 m cable, part no. 086U3365 (regards 1 x sensor) One of the following modular cables: Modular cable 0.3 m, part no. 086U4227 Modular cable 1.1 m, part no. 086U4228 Modular cable 10.0 m, part no. 086U4229 Electrical connection TWC Temperature input, T1: Sensor, HW heater Temperature input, T2: Sensor, HW return Analogue output 010V, AO1: Relay, DO1: Signal to immersion heater, hot water (potential free connection, max 6A) DHPR VKBMA302 3

Expansion module HPC EM, Shunt Function Abelko 086U3395 The expansion module in the Shunt function mode maintains the desired temperature for another heating circuit. The Shunt function is achieved by moving the switch according to the figure to the side. Shunt valve Heating circuit 2 Heating circuit 1 Sensor shunt temperature Circulation pump CW HW HWC Expansion module Shunt function WH WH WH WH Modular cable Brine circuit DHPR Hot gas circuit Accompanying accessories 1 x PT1000 strap on sensor part no. 086U3365 One of the following modular cables: Modular cable 0.3 m, part no. 086U4227 Modular cable 1.1 m, part no. 086U4228 Modular cable 10.0 m, part no. 086U4229 Electrical connection Shunt function Temperature input, T1: Sensor, shunt temperature Temperature input, T2: Analogue output 010V, AO1: Signal to shunt valve Relay, DO1: Signal to circulation pump, (potential free connection, max 6A) Shunt valve, circulation pump. 4 VKBMA302 Accessories guide

Cooling module HPC CM Abelko 086U3394 Passive cooling means that coolant circulates through the bore hole and the coolant tank without any heat pump starting. Only circulation pumps for heat transfer fluid are used. The heat from the coolant tank is transported down into the rock. A condition for passive cooling to work is that the coolant is colder than the coolant tank. Active cooling means that a heat pump starts which then lowers the temperature of the coolant before it enters the coolant tank. If the integral continues to rise, more heat pumps start. The valve for active cooling shifts position and disconnects the borehole. The coolant therefore only circulates through the cooling tank and heat pump so that all produced cooling can be used. An extra function that can be activated in the cooling module is dew point control. This function is not necessary, but if it is to be activated more information can be found under the accessory Dew point sensor. DHPR VKBMA302 5

Cooling module cont d. Heating circuit Dew point sensor Exchange valve coolant cooler Sensor, output cooling tank Circulation pump coolant cooler Cooling fan Control valve cooling circuit Sensor, coolant cooler Cooling circuit Cooling tank Sensor cooling tank Sensor, cooling circuit Circulation pump cooling circuit Cooling module DHPR Modular cable Exchange valve cooling tank Brine circuit Exchange valve coolant return Accompanying accessories 4 x PT1000 strap on sensors with 2 m cable, part no. 086U3365 (regards 1 x sensor) One of the following modular cables: Modular cable 0.3 m, part no. 086U4227 Modular cable 1.1 m, part no. 086U4228 Modular cable 10.0 m, part no. 086U4229 Dew point sensor for wall mounting, part no. 086U3396 (if the dew point function is to be used) Electrical connection Temperature input, T1: Sensor, cooling tank Temperature input, T2: Sensor, coolant cooler Temperature input, T3: Sensor, output cooling tank Temperature input, T4: Sensor, cooling circuit Analogue input 010V, AI1: Signal from dew point sensor, room temperature 0 50 C Analogue input 010V, AI2: Signal from dew point sensors, rel. Humidity 0 100% Analogue output 010V, AO1: Signal to control valve cooling circuit Analogue output 010V, AO2: Signal to cooling fans Relay 24VAC, DO1: Signal to exchange valve, cooling tank (passive cooling) Relay 24VAC, DO2: Signal to exchange valve, coolant return (active cooling) Relay 24VAC, DO3: Signal to circulation pump coolant cooler Relay 24VAC, DO4: Signal to exchange valve, coolant cooler Relay 24VAC, DO5: Signal to circulation pump, cooling circuit Control valve, exchange valves, circulation pumps. 6 VKBMA302 Accessories guide

Strap on Sensor with Connection Box PT1000 ThermokonDanelko 086U3356 Strap on sensor used in several places in the system to read the temperature. The sensor lies against the pipe and senses temperatures in the range 0160. Technical data Resistance table: Temperature Ohm 40 842.7 35 862.5 30 882.2 25 901.9 20 921.6 15 941.2 10 960.8 5 980.4 0 1000.0 5 1019.5 10 1039.0 15 1058.5 20 1077.9 25 1097.3 30 1116.7 35 1136.1 40 1155.4 45 1174.7 50 1194.0 55 1213.2 60 1232.4 65 1251.6 70 1270.7 75 1289.9 80 1309.0 85 1328.0 90 1347.1 95 1366.1 100 1385.1 DHPR VKBMA302 7

Strap on Sensor with Connection Box PT1000 cont d Accompanying accessories Installation Tighten the sensor around the pipe using cable tie. Then apply insulation tape/insulation on the outside, depending on the type of pipe. Electrical connection 1524VDC/24VAC supply voltage. The strap on sensor is connected to WM HPC, Temperature input T1 or T2 and GND. 8 VKBMA302 Accessories guide

Submersible sensor PT1000 ThermokonDanelko 086U3364 Submersible sensor used to read the temperature in the return line from the heat exchanger, see the system image below. The sensor is installed inside the pipe and senses temperatures in the range 0160. Heat exchanger Submersible sensor DHPR VKBMA302 9

Submersible sensor PT1000 cont d Technical data Resistance table for submersible sensor: Temperature Ohm 40 842.7 35 862.5 30 882.2 25 901.9 20 921.6 15 941.2 10 960.8 5 980.4 0 1000.0 5 1019.5 10 1039.0 15 1058.5 20 1077.9 25 1097.3 30 1116.7 35 1136.1 40 1155.4 45 1174.7 50 1194.0 55 1213.2 60 1232.4 65 1251.6 70 1270.7 75 1289.9 80 1309.0 85 1328.0 90 1347.1 95 1366.1 100 1385.1 Accompanying accessories Electrical connection The submersible sensor is connected to the heat exchanger return line as close to the heat exchanger as possible. Connected to EM HPC, temperature input T1 and GND. 10 VKBMA302 Accessories guide

Modular cables Abelko Modular cable 0.3 m: 086U4227 Modular cable 1.1 m: 086U4228 Modular cable 10.0 m: 086U4229 Conductor joint: 086U4230 The modular cable is a cable that joins the various units. Connections can be made between several heat pumps or between different accessory modules internally in the heat pump. Conductor joint to connect and extend two or more modular cables. Accompanying accessories Electrical connection The modular cable is connected to one of the connections Exp.in or Exp.out. DHPR VKBMA302 11

Flow Guard Kit IFM 086U3368 Weld nipple 1 LED display 2 Programming button The flow guard is an electronic guard that does not contain any moving parts. It is used for ground water or lake water systems and ensures that there is a sufficiently large flow through the heat exchanger. See accompanying figure. Connection cable Supplied accessories Flow guard IFM SI5001, part no. 086U3345 Weld nipple IFM E40113, part no. 086U3367 Connection cable IFM EVC005, part no. 086U3366 Flow guard Brine WM HPC DHPR Hot gas circuit Electrical connection The flow guard is connected using the connection cable to the heat pump s control computer. The threecore connection cable is connected as follows: Brown cable, positive terminal (+), connected to terminal block 147 Blue cable, negative terminal (), connected to terminal block 148 Black cable, signal in, connected to terminal block 124 Weld nipple Ground water well Heat exchanger Heat exchanger 12 VKBMA302 Accessories guide

Switching Valve for Hot Water, DHPR NordiCold 086U2471 The exchange valve is of the ball exchange valve type. It is used to control the flow of hot water to either the heating system or hot water heaters depending on the heating demands. See accompanying figure. Exchange valve HW Heating circuit Supplied accessories Electrical connection The exchange valve s motor connects to HPC RM, digital output 24 VAC, DO4. Hot water HPC RM Brine Hot gas circuit DHPR Technical data Exchange valve DN 32 internal thread Motor Valve body Brass Supply voltage 24V/50Hz Ball Chromed brass Output 5 VA Fluid temperature 0 C to 100 C Rotation time 15 seconds Max. Differential pressure 6 bar Torque 6 Nm Seal valve housing PTFE Potential free contact 5A/230V Orings EPDM Protection class IP54 DHPR VKBMA302 13

Hot Gas Circuit Circulation Pump Kit Wilo 086U4233 The hot gas pump is a circulation pump for the hot gas circuit. See accompanying figure. The kit contains the following accessories: 1 x circulation pump Wilo Star RS25/4 3P, part no. 086U4231 2 x union joints with shutoff, Ø 28 clamp ring RSK 5805928, part no. 086U4232 (refers to 2 x connections) Electrical connection Hot gas pump connected to terminal block DHPR according to electrical instruction. Flexible hoses, strainer, valve for adjusting flow. WM HPC Flexible hoses Strainer Valve Hot gas circuit DHPR Hot gas pump 14 VKBMA302 Accessories guide

Room Sensor ThermokonDanelko 086U3354 The room sensor is an active sensor for room temperature. The sensor is wallmounted. Supplied accessories Electrical connection 24VAC supply voltage. The room sensor is connected to WM HPC, analogue input 010V, AI1. Measurement range: Temperature: 0 50 C. DHPR VKBMA302 15

Dew Point Sensor ThermokonDanelko 086U3396 Dew point control is an extra function that ensures that condensation precipitation cannot occur on the cooling circuit. If the temperature and humidity reaches the dew point, the supply set point is adjusted upwards. The sensor is wallmounted. Accompanying accessories Electrical connection 24VAC supply voltage. The dew point sensor is connected to HPC CM (cooling module) to the inputs AI1 (temperature) and AI2 (humidity). Measurement range: Rel. humidity: 5 95%. Temperature: 0 50 C. 16 VKBMA302 Accessories guide

Web Access Abelko 086U3392 (HP1) 086U3393 (HP28) Used to monitor the heat pump using a web interface. Alarm notification can occur via SMS or email. The accessory consists of a code that can access the heat pump via the Internet. Web access HP 1 refers to unlocking heat pump #1 in a system, i.e. master heat pump. This enables full access to heat pump 1 and other connected units in the heat pump, for example expansion modules. Alarm management and statuses for the entire system can be obtained, for example, for slave heat pumps. Web access HP 28 refers to unlocking heat pumps #2 to #8 in a system, i.e. slave heat pumps. This means that the temperatures of all heat pumps can be viewed via the web interface. Web access can only be used if there is a network connection in the installation area. Accompanying accessories Electrical connection DHPR VKBMA302 17

Router for Web Access DLink 086U4840 Used to connect to the heat pump via the Internet. The router directs the network traffic between the local network where the heat pump is and the Internet. It also limits the amount of incoming traffic from the Internet. The router is preconfigured and ports out 10.0.48.94 and 10.0.48.101 to 10.0.48.109, which means that no settings need to be made at connection. Supplied accessories 10 + 2 metre network cable supplied with router. Connection The router has a WAN port which is connected to a broadband modem or a broadband socket, see images below. It also has four network sockets for a local network, to which you can connect your heat pumps. If four sockets are not enough, use a switch. The network cable must be connected from the Ethernet socket on WM HPC in the heat pump and to a spare port in the router. Internet Modem Router WAN port Internet Modem Router WAN port 18 VKBMA302 Accessories guide

Soft Start Kimsafe 086U5642 Used to limit the current when the heat pump is started. Soft start distributes the current consumption for a few seconds and enables the heat pump to start slower, to prevent current peaks in the electrical network. Technical data The table below shows the current consumption when DHPR is started with and without soft start. Heat pump, DHPR 21H 25H 20 26 35 42 Starting without soft start (A) 167 198 99 127 167 198 Starting with soft start (A) 96 106 69 82 96 106 Supplied accessories Panel, screws as well as wiring and cable tie for installation. Installation The soft starter is installed between the unit cabinet and compressor, according to the overview image to the right. Detailed installation instructions are supplied with the soft starter. Electrical connection See wiring diagram and installation instructions included with the product. Soft Start DHPR VKBMA302 19

Electronic Valve Actuator SQS 65.5 For WCS function (hot water charging) Siemens 086U4837 The valve actuator controls the valve that opens the flow through the heat exchanger for hot water heating. The motor has a 35 second setup time, DC 010 V control signal, AC 24 V supply voltage and mode indication. Manual setting is possible. Heating circuit Control valve CW HW HWC WH WH WH WH Brine circuit DHPR Hot gas circuit Accompanying accessories Control valve VVG 44.2510 (2way). For charge output up to 110 kw. Part number 086U3730 or control valve VVG 44.3216 (2way). For charge output 110180 kw. Part number 086U3731 20 VKBMA302 Accessories guide

Electronic Valve Actuator SQS 65.5 cont d Installation Screw the actuator directly onto the valve in the vertical to horizontal position. No adjustments necessary. Electrical connection Analogue output 010V, AO1: Signal to control valve Digital output 24 VAC 2.1, DO1.1: Signal to charge pump Digital output 24 VAC 2.2, DO1.2: Signal to charge pump M 24 VAC 2.1 24 VAC 2.2 Exp.in DO1.1 DO1.2 HPC EM WCS SQS 65.5 G G 0 Y 1 T1 T2 AO1 GND Exp.out 010V 24 VAC 2.1 24 VAC 2.2 DHPR VKBMA302 21

Valve Actuator ESBE ESBE 086U5272 Valve actuator that is used to control ESBE shunt valves. Proportional or 3 or 2 step control signal. Manual control also possible. Shunt valve 2 Shunt valve 1 Heating circuit 2 Heating circuit 1 Sensor shunt temperature Circulation pump CW HW HWC WH WH WH WH Expansion module Shunt function DHPR Brine circuit Hot gas circuit Supplied accessories The actuator is supplied with an adapter for connection to the shunt valve, as well as a 1.5 m connection cable. Technical data Motor Supply voltage Output Rotation time Protection class 24V AC/DC, 50/60 Hz 5 VA 45/120 seconds IP41 Installation The actuator is installed on the valve using an adapter. Installation instructions supplied with the valve on delivery. 22 VKBMA302 Accessories guide

Valve Actuator ESBE cont d Electrical connection Analogue output 010V, AO1: Signal to control valve Electrical connection of shunt valve which is used for auxiliary heat: WMHPC AO1 GND 24 VAC 2.2 24 VAC 2.1 143 144 145 146 L N Y ARA659 Electrical connection of shunt valve which is used for subshunt group: M 24 VAC 2.1 24 VAC 2.2 Exp.in DO1.1 DO1.2 ESBE ARA659 Y L N HPC EM WCS T1 T2 AO1 GND Exp.out 010V 24 VAC 2.1 24 VAC 2.2 DHPR VKBMA302 23

Shunt valves ESBE ESBE 086U5265 3way shunt valve VRG131 DN20KVS 6.3 086U5266 3way shunt valve VRG131 DN25KVS 10 086U5267 3way shunt valve VRG131 DN32KVS 16 086U5268 3way shunt valve VRG131 DN40KVS 25 ESBE shunt valves are used partly as exchange or distribution valves to control the water flow when using external heat sources, for example, oilfired boilers (shunt valve in the system image on the previous page). They are also used to control the flow to the subshunt groups, i.e. additions to the heating system, and regulate heating or cooling in the radiator and floor heating systems or other similar applications (shunt valve 2 in the system image on the previous page). See previous section, Valve Actuator ESBE. Technical data Shunt valve Valve body Control Dezincificationresistant brass PPS composite Fluid temperature 10 C to 130 C Max. Differential pressure Orings 1 bar (mixture) 2 bar (distribution) EPDM 24 VKBMA302 Accessories guide

Shunt valves ESBE cont d The valve that is to be selected is determined partly by the Kvs value, i.e. the capacity value in m³/hours at a pressure drop of 1 bar, and partly by the system that the valve is to serve. For radiator systems, normally select t = 20 C and for floor heating t = 5 C. Suitable pressure drop is 315 kpa. To select the correct valve dimension use the diagram below. Start from the output requirement (e.g. = 25 kw) and go vertically to t (e.g. = 15 C). Continue horizontally to the shaded area (pressure drop = 3 10 kpa) and select the smaller option (e.g. Kvs = 6.3). Dimensioning the shunt valve for boiler installations Kvs = 400 280 225 Flow m 3 /h 100 150 90 50 60 44 20 10 5 2 1 28 18 12 8 6.3 4 2.5 0.5 0.3 10 20 50 100 200 500 0.2 0.5 1 2 3 5 10 20 40 kw Pressure drop kpa Output DHPR VKBMA302 25

Shunt valves ESBE cont d For control valves, the Kvs value is always given in one (heat conducting) direction. Pressure drop chart Flow m 3 /h l/s 200 500 100 200 50 Kvs m 3 /h 400 280 225 150 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 20 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 1 2 5 10 20 50 100 Pressure drop kpa 90 60 44 28 18 12 8 6.3 4,0 2,5 1.6 1.2 1.0 0.6 26 VKBMA302 Accessories guide

Flow Adjustment Valve for hot gas circuit Nordicold 086U3757 216 l/min The flow adjustment valve is used to adjust the water flow through the hot gas circuit to a suitable low level to optimise the heat pump s efficiency. The valve that is to be selected is calculated by max 20% of the nominal condenser flow on the heat pump. This valve is selected for the following flows: DHPR 21H = DHPR 25H = DHPR 20 = DHPR 26 = DHPR 35 = DHPR 42 = 6 l/min 7.2 l/min 6 l/min 7.2 l/min 9.6 l/min 12 l/min Flow adjustment valve DHPR VKBMA302 27

Flow Adjustment Valves for hot gas circuit cont d Technical data Flow adjustment valve Housing and insert Brass Flow gauge shockproof and temperature resistant plastic Spring stainless steel Oring EPDM Maximum operating temperature See pressure/temperature diagram Min operating temperature 20 Max operating temperature see pressure drop chart Flow accuracy ±10% over the actual reading Pressure/temperature diagram 12 Max operating pressure PB (bar) 10 8 6 4 2 0 20 40 60 80 100 120 Maximum operating temperature TB ( C) 28 VKBMA302 Accessories guide

Flow Adjustment Valves for hot gas circuit cont d Pressure drop chart 0 1 2 3 4 5 6 Pressure drop chart (mbar) Accompanying accessories Installation The valves can be supplied with pipe connections with external thread, soldered connections or clamp ring connections. The group valve can be installed in all positions. To achieve the exact flow a straight pipe piece is recommended (the same length as the valve body) on the supply side. Installation instructions supplied with the valve on delivery. Electrical connection Flow (l/min) DHPR VKBMA302 29

VKBMA202