DRUCK & TEMPERATUR LEITENBERGER GMBH DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600 bar Output signals -wire:... 0 ma -wire: 0 0 ma / 0 0 V others on request Special characteristics excellent long-term stability, also with high dynamic pressure loads insensitive to pressure peaks high overpressure capability Optional versions IS-version Ex ia = intrinsically safe for gases and dusts SIL version according to IEC 6508 / IEC 65 The pressure transmitter type DMP has been especially designed for use in hydraulic applications with high static and dynamic pressure. The transmitter is characterized by an excellent long term stability, also under fast changing pressure as well as positive and negative pressure peaks. The modular concept of the device allows to combine different stainless steel sensors and electronic modules with a variety of electrical and mechanical versions.thus a diversity of variations is created, meeting almost all requirements in hydraulic applications. Preferred areas of use are Plant and Machine Engineering - machine tools - hydraulic presses - injection moulding machine - handling equipment - elevated platforms - test benches Mobile Hydraulics specific versions DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D-78 Kirchentellinsfurt GERMANY Tel. +9 (0) 7-9090-0 Fax +9 (0) 7-9090-99 E-Mail: DT-Info@Leitenberger.de www.druck-temperatur.de
DMP Input pressure range Nominal pressure gauge / abs. [bar] 00 60 50 00 600 Overpressure [bar] 0 600 000 000 000 Burst pressure [bar] 000 000 50 50 800 measurement starts with ambient pressure Output signal / Supply Standard -wire:... 0 ma / V S = 8... V DC SIL-version: V S = 8 V DC Option IS-protection -wire:... 0 ma / V S = 0... 8 V DC SIL-version: V S = 8 V DC Options -wire -wire: 0... 0 ma / V S =... 0 V DC 0... 0 V / V S =... 0 V DC Performance Accuracy standard: ± 0.5 % FSO option : ± 0.5 % FSO option : ± 0. % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] current -wire: R max = 500 voltage -wire: R min = 0 k Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / k Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Tolerance band ± 0.75 % FSO in compensated range 0... 70 C Permissible temperatures Permissible temperatures medium: -0... 5 C electronics / environment: -0... 85 C storage: -0... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 00 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.0 (6 L) Housing stainless steel.0 (6 L) Option compact field housing stainless steel.05 (0), cable gland brass, nickel plated others on request Seals (media wetted) standard: FKM options: EPDM (for P N 60 bar) others on request Diaphragm stainless steel.5 (6 L) Media wetted parts pressure port, seals, diaphragm Explosion protection (only for... 0 ma / -wire) Approvals IBExU 0 ATEX 068 X / IECEx IBE.007X DX9-DMP zone 0: II G Ex ia IIC T Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V DC, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 H, the supply connections have an inner capacity of max. 7 nf to the housing Permissible temperatures for environment in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone or higher: -0... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: H/m DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D-78 Kirchentellinsfurt GERMANY Tel. +9 (0) 7-9090-0 Fax +9 (0) 7-9090-99 E-Mail: DT-Info@Leitenberger.de www.druck-temperatur.de
DMP Miscellaneous Option SIL according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight approx. 0 g Installation position any Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) 5 ATEX Directive 9/9/EG only for 0 ma / -wire, not in combination with the accuracy 0.% Pressure transmitters are calibrated in a vertical position with the pressure connection down. 5 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) p supply + VS VS supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 00 Supply + Supply Signal + (for -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) Mx/metal (-pin) Bayonet MIL-C- 68 (0-6) -wire Shield ground pin 5 pressure port A B - -wire A D B field housing IN + IN OUT + cable colours (DIN 700) wh (white) bn (brown) gn (green) ye/gn (yellow/green) standard option ISO 00 Binder Series 7 5-pin Mx -pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 6 Bayonet MIL-C-68 (0-6) compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 67) (IP 68) 7 universal field housing stainless steel.0 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 6 standard: m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 7 different cable types and lengths available, permissible temperature depends on kind of cable DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D-78 Kirchentellinsfurt GERMANY Tel. +9 (0) 7-9090-0 Fax +9 (0) 7-9090-99 E-Mail: DT-Info@Leitenberger.de www.druck-temperatur.de
06 DRUCK & TEMPERATUR Leitenberger GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 59 DMP Mechanical connections (dimensions in mm) standard for accuracy 0.5 / 0.5 % standard for accuracy 0. % ; SIL- and SIL-IS-version G/" DIN 85 G/" DIN 85 with ISO 00 with ISO 00 option G/" EN 87 G/" DIN 85 G/" EN 87 /" NPT metric threads and other versions on request DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D-78 Kirchentellinsfurt GERMANY Tel. +9 (0) 7-9090-0 Fax +9 (0) 7-9090-99 E-Mail: DT-Info@Leitenberger.de www.druck-temperatur.de
DMP DRUCK & TEMPERATUR LEITENBERGER GMBH DMP - - - - - - - Spezifikationsblatt / specification sheet Messgröße Pressure relativ absolut gauge absolute 0 Eingang [bar] Input [bar] 00 00 0 0 60 60 6 0 50 50 5 0 00 00 0 0 600 Sondermessbereiche 600 6 0 0 9 Ausgang Output 0 ma / -Leiter 0 0 ma / -Leiter 0 0 V / -Leiter Ex-Schutz 0 ma / -Leiter SIL 0 ma / -Leiter 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 0 ma / -wire SIL 0 ma / -wire E S SIL mit Ex-Schutz SIL with Intrinsic safety 0 ma / -Leiter 0 ma / -wire ES Genauigkeit Accuracy Standard 0,5 % standard 0.5 % Option 0,5 % option 0.5 % Option 0, % option 0. % Elektrischer Anschluss Electrical connection Stecker und Kabeldose ISO 00 Stecker Binder Serie 7 (5-polig) Male and female plug ISO 00 Male plug Binder series 7 (5-pin) 0 0 0 0 Kabelausgang mit PVC-Kabel Cable outlet with PVC cable Kabelausgang Cable outlet T A 0 T R 0 Stecker Mx (-polig) / Metall Bajonett MIL-C-68 (0-6); -Leiter Bajonett MIL-C-68 (0-6); -Leiter Male plug Mx (-pin) / metal Bayonet MIL-C-68 (0-6); wire Bayonet MIL-C-68 (0-6); wire M 0 B G 0 B G Kompakt-Feldgehäuse Compact field housing Edelstahl.05 stainless steel.05 8 5 0 Mechanischer Anschluss Mechanical connection G/" DIN 85 G/" EN 87 G/" DIN 85 G/" EN 87 /" NPT G/" DIN 85 G/" EN 87 G/" DIN 85 G/" EN 87 /" NPT 0 0 0 0 0 0 0 0 N 0 0 Dichtung Seals FKM FKM 5 EPDM EPDM Sonderausführungen Special version Standard standard 0 0 0 Preise EXW Thierstein, ausschl. VerpackPrices EXW Thierstein, excluding package Messanfang bei Umgebungsdruck measurement starts with ambient pressure nicht in Verbindung mit SIL not in combination with SIL Standard: m PVC-Kabel ohne Belüftungsschlauch (Tstandard: m PVC cable without ventilation tube (permissible temperature: -5 70 C), optionally without ventilation tube Kabel mit Luftschlauch (Code TR0 = PVC-Kabel), Kab cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, permissible temperature depends on kind of cable, price without cable 5 nur möglich für P N 60 bar possible for nominal pressure ranges P N 60 bar Rel. 0608 DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. D-78 Kirchentellinsfurt GERMANY Tel. +9 (0) 7-9090-0 Fax +9 (0) 7-9090-99 E-Mail: DT-Info@Leitenberger.de www.druck-temperatur.de