NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Similar documents
Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Versatile and Powerful

LF Series At A Glance

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

FSAF24(-S) US, FSAF120(-S) US

Versatile and Powerful

Minimum 27 in-lb torque

Minimum 27 in-lb Torque

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

AF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator

ZG106 or ZG 107 bracket

AFXUP-S (p. 19) AFB24-MFT. AFXUP (p. 19) AFBUP-S

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

AF Series Spring Return Direct Coupled Actuator

Belimo is the Worldwide Leader in Fire and Smoke Actuation

Product Cross Reference

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Minimum 18 in-lb Torque

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Torque min. 35 in-lb, for control of air dampers

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LF Series Spring Return Direct Coupled Actuator

G3 (D) 3-way Globe Valve, Bronze Trim

AM Series Direct Coupled Actuator

G6 C(S)(LCS) 2-way Pressure Compensated Flanged Globe Valve

BELIMO CONTROLS

GM Series Direct Coupled Actuator

G7 (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Mounting Installation Instructions LM, NM, AM, GM

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

F6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Installation Instructions

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

G780, 3-Way, Mixing Flanged Globe Valve

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Mounting Installation Instructions NKQ, GK

AF24-MFT95 US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for Use with Honeywell Electronic Series 90, or a 0 to 135Ω input

Accessories. Technical Data Extension Height 2" Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

F6 Series 2-Way, Victaulic Butterfly Valve

Installation Instructions

B278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

RUS-L24-MOD Electric 24 Volt Modulating Control Damper Actuator

M9208-xxx-x Series Electric Spring Return Actuators

M9208-xxx-x Series Electric Spring-Return Actuators

M9220 Series Electric Spring-Return Actuators

Non-Spring Return EconoDrive Floating Actuator

M9208-xxx-x Series Electric Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

G7100S, 3-Way, Mixing Flanged Globe Valve

Commercial Actuator Selection Chart Non-Spring Return

NV Direct Coupled Globe Valve Actuator

M9203-xxx-2(Z) Series Electric Spring Return Actuators

MA40-704X Series MA41-707X Series MA41-715X Series

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

B2 Series Characterized Control Valve, Non-Spring Return Actuator

M9220-xxx-3 Electric Spring Return Actuators

MS Series MS Series MS Series

Installation Instructions

VA9208-xxx-xx Series Electric Spring Return Actuators

Globe Valve Retrofits

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

MF Series MF Series MF Series

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Pressure Independent Characterized Control Valves (PICCV)

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Technical Documentation Ball Valves

Electronic Globe Valves

Power consumption In operation At rest For wire sizing

Strobic Air, a Met-Pro Product Recovery/Pollution Control Technologies Business, is pleased to submit the attached proposal for your consideration.

VA9208-xxx-xx Series Electric Spring-Return Actuators

G765, 3-Way, Mixing Flanged Globe Valve

Pressure Independent Characterized Control Valves (PICCV)

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

M9300 Series Electric Non-Spring Return Actuators

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Transcription:

NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4... NFB4, NFB4-S, NFX4, NFX4-S 4 VAC ± 0% 50/60 Hz 4 VDC +0% / -10% running 6 W holding.5 W 8.5 VA (class power source) 3 ft, 18 GA appliance cable, 1/" conduit -S models: Two 3 ft, 18 gauge appliance cables with 1/ conduit s 3 ft [1m], 10 ft [3m] or 16 ft [5m] 18 GA appliance or plenum cables, with or without 1/ conduit -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [5m] appliance cables, with or without 1/" conduit s Electronic throughout 0 to 95 rotation On/Off 90 in-lb [10 Nm] minimum spring reversible with CW/CCW mounting Overload protection Control Torque Direction of rotation Mechanical angle of rotation 95 (adjustable with mechanical end stop, 35 to 95 ) Running time motor < 75 sec spring 0 sec @ -4 F to 1 F [-0 C to 50 C]; < 60 sec @ - F [-30 C] Position indication visual indicator, 0 to 95 (0 is full spring return position) Manual override 5 mm hex crank (³ ₁₆" Allen), supplied Humidity max. 95% RH non-condensing Ambient temperature - F to 1 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing Nema, IP54, Enclosure Type Housing material Zinc coated metal and plastic casing Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/95/EC Noise level <50dB(A) motor @ 75 seconds 6dB(A) spring return Servicing maintenance free Quality standard ISO 9001 Weight 4.15 lbs (1.9 kg); 4.5 lbs (1.9 kg) with switches Rated Impulse Voltage 800V, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3. NFB4-S, NFX4-S Auxiliary switches x SPDT 3A (0.5A) @ 50 VAC, UL Approved one set at +10, one adjustable 10 to 90 Application For On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. Control is On/Off from an auxiliary contact, or a manual switch. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The NFB and NFX series actuators provide true spring return operation for reliable fail-safe application and positive close off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The NFB and NFX series provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The NFB4-S and NFX4-S versions are provided with built-in auxiliary switches. These SPDT switches are provided for safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. The NFB4, NFB4-S, NFX4 and NFX4-S actuator is shipped at +5 (5 from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered 1.05" Centered WAFBNFBDim 60

NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Mounting bracket for Barber Colman MA 3../4.., Honeywell Accessories AV 8-5 Shaft extension IND-AFB Damper position indicator KH-AFB Crankarm K7- Universal clamp for up to 1.05 dia jackshafts TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-118 Mod III or IV or Johnson Series 100 replacement or new crankarm type installations ZG-AFB Crankarm adaptor kit ZG-AFB118 Crankarm adaptor kit ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing Note: When using NFB4, NFB4-S, NFX4, NFX4-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to Belimo Wiring Guide. Typical Specification On/Off spring return damper actuators shall be direct coupled type which require no crankarm and linkage and be capable of direct mounting to a jackshaft up to a 1.05 diameter. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall be protected from overload at all angles of rotation. If required, SPDT auxiliary switch shall be provided having the capability of one being adjustable. Actuators with auxiliary switches must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings. Actuators shall be culus Approved and have a 5 year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 4 VDC. For end position indication, interlock control, fan startup, etc., NFB4-4 S and NFX4-S incorporates two built-in auxiliary switches: x SPDT, 3A (0.5A) @50 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Meets culus requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 4 VAC Transformer Line 1 Common Volts + Hot 3 On/Off wiring for NFB4, NFX4 NFB4, NFB4-S NFX4, NFX4-S W063_NFB(X) Auxiliary Switches for NFB4-S, NFX4-S NFB4-S NFX4-S W064_NFB(X)_-S 61

NFBUP, NFBUP-S, NFXUP, NFXUP-S On/Off, Spring Return, 4 to 40 VAC Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFBUP... NFXUP... NFBUP, NFBUP-S, NFXUP, NFXUP-S 4...40 VAC -0% / +10%, 50/60 Hz 4...15 VDC ±10% running 6 W holding.5 W 9.5 VA (class power source) 3 ft, 18 GA appliance cable, 1/" conduit -S models: Two 3 ft, 18 gauge appliance cables with 1/ conduit s 3 ft [1m], 10 ft [3m] or 16 ft [5m] 18 GA appliance cable, with or without 1/ conduit -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [5m] appliance cables with or without 1/" conduit s Electronic throughout 0 to 95 rotation On/Off 90 in-lb [10 Nm] minimum spring reversible with CW/CCW mounting Overload protection Control Torque Direction of rotation Mechanical angle of rotation 95 (adjustable with mechanical end stop, 35 to 95 ) Running time motor < 75 sec spring 0 sec @ -4 F to 1 F [-0 C to 50 C]; < 60 sec @ - F [-30 C] Position indication visual indicator, 0 to 95 (0 is full spring return position) Manual override 5 mm hex crank (³ ₁₆" Allen), supplied Humidity max. 95% RH non-condensing Ambient temperature - F to 1 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing Nema, IP54, Enclosure Type Housing material Zinc coated metal and plastic casing Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/95/EC Noise level <50dB(A) motor @ 75 seconds 6dB(A) spring return Servicing maintenance free Quality standard ISO 9001 Weight 4.15 lbs (1.9 kg), 4.5 lbs (1.9 kg) with switches Rated Impulse Voltage 4kV, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3. NFBUP-S, NFXUP-S Auxiliary switches x SPDT 3A (0.5A) @ 50 VAC, UL Approved one set at +10, one adjustable 10 to 90 Application For On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. Control is On/Off from an auxiliary contact, or a manual switch. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The NFB and NFX series actuators provide true spring return operation for reliable fail-safe application and positive close off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The NFB and NFX series provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The NFBUP-S and NFXUP-S versions are provided with built-in auxiliary switches. These SPDT switches provide safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. The NFBUP, NFBUP-S, NFXUP and NFXUP-S actuator is shipped at +5 (5 from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered 1.05" Centered WAFBNFBDim 6

NFBUP, NFBUP-S, NFXUP, NFXUP-S On/Off, Spring Return, 4 to 40 VAC Mounting bracket for Barber Colman MA 3../4.., Honeywell Accessories AV 8-5 Shaft extension IND-AFB Damper position indicator K7- Universal clamp for up to 1.05 dia jackshafts KH-AFB Crankarm TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-118 Mod III or IV or Johnson Series 100 replacement or new crankarm type installations ZG-AFB Crankarm adaptor kit ZG-AFB118 Crankarm adaptor kit ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing Note: When using NFBUP, NFBUP-S, NFXUP, NFXUP-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to Belimo Wiring Guide. Typical Specification On/Off spring return damper actuators shall be direct coupled type which require no crankarm and linkage and be capable of direct mounting to a jackshaft up to a 1.05 diameter. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall be protected from overload at all angles of rotation. If required, SPDT auxiliary switch shall be provided having the capability of one being adjustable. Actuators with auxiliary switches must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings. Actuators shall be culus Approved and have a 5 year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 No ground connection is required. For end position indication, interlock control, fan startup, etc., NFBUP- 4 S and NFXUP-S incorporates two built-in auxiliary switches: x SPDT, 3A (0.5A) @50 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Meets culus requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off wiring for NFBUP, NFXUP NFBUP, NFBUP-S NFXUP, NFBUP-S W066_NFB(X)UP W067_NFB(X)UP-S Auxiliary Switches for NFBUP-S, NFXUP-S NFBUP-S NFXUP-S 63

NFB4-SR, NFB4-SR-S, NFX4-SR, NFX4-SR-S Proportional, Spring Return, 4 V, for or 10 VDC or 4 to 0 ma Control Signal Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB... NFX... Overload protection Operating range Y Input impedance Feedback output U Torque Direction of rotation NFB4-SR, NFB4-SR-S, NFX4-SR, NFX4-SR-S 4 VAC ±0%, 50/60 Hz 4 VDC +0% / -10% running 3.5 W holding.5 W 6 VA (class power source) 3 ft, 18 GA appliance cable, 1/" conduit -S models: Two 3 ft, 18 gauge appliance cables with 1/ conduit s 3 ft [1m], 10 ft [3m] or 16 ft [5m] 18 GA appliance or plenum cables, with or without 1/ conduit -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [5m] appliance cables, with or without 1/" conduit s Electronic throughout 0 to 95 rotation to 10 VDC, 4 to 0mA 100 kω for to 10 VDC (0.1 ma) 500 Ω for 4 to 0 ma to 10 VDC (max. 0.5 ma) 90 in-lb [10 Nm] minimum spring reversible with CW/CCW mounting motor reversible with built-in switch Mechanical angle of rotation 95 (adjustable with mechanical end stop, 35 to 95 ) Running time spring < 0 sec @ -4 F to 1 F [-0 C to 50 C]; < 60 sec @ - F [-30 C] motor 95 sec Position indication visual indicator, 0 to 95 (0 is full spring return position) Manual override 5 mm hex crank (³ ₁₆" Allen), supplied Humidity max. 95% RH non-condensing Ambient temperature - F to 1 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing Nema, IP54, Enclosure Type Housing material Zinc coated metal and plastic casing Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/95/EC Noise level 40dB(A) motor @ 95 seconds 6dB(A) spring return Servicing maintenance free Quality standard ISO 9001 Weight 4.15 lbs (1.9 kg); 4.5 lbs (1.9 kg) with switches Rated Impulse Voltage 800V, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3. NFB4-SR-S, NFX4-SR-S Auxiliary switches x SPDT 3A (0.5A) @ 50 VAC, UL Approved one set at +10, one adjustable 10 to 90 Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator operates in response to a to 10 VDC, or with the addition of a 500Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. A to 10 VDC feedback signal is provided for position indication. Not to be used for a master-slave application. Operation The NFB and NFX series actuators provide true spring return operation for reliable fail-safe application and positive close-off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The NFB and NFX series provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The NFB4-SR and NFX4-SR uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact fail-safe position. The ASIC monitors and controls the brushless DC motor s rotation and provides a digital rotation sensing function to prevent damage to the actuator in a stall condition. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The NFB4-SR-S and NFX4-SR-S versions are provided with built-in auxiliary switches. These SPDT switches provide safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. The NFB4-SR, NFB4-SR-S, NFX4-SR and NFX4-SR-S actuator is shipped at +5 (5 from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered 1.05" Centered WAFBNFBDim 64

NFB4-SR, NFB4-SR-S, NFX4-SR, NFX4-SR-S Proportional, Spring Return, 4 V, for or 10 VDC to 4 to 0 ma Control Signal Mounting bracket for Barber Colman MA 3../4.., Honeywell Accessories AV 8-5 Shaft extension IND-AFB Damper position indicator KH-AFB Crankarm K7- Universal clamp for up to 1.05 dia jackshafts TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-118 Mod III or IV or Johnson Series 100 replacement or new crankarm type installations ZG-AFB Crankarm adaptor kit ZG-AFB118 Crankarm adaptor kit ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing NOTE: When using NFB4-SR, NFB4-SR-S, NFX4-SR and NFX4-SR-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to Belimo Wiring Guide. Typical Specification Spring return control damper actuators shall be direct coupled type which require no crankarm and linkage and be capable of direct mounting to a jackshaft up to a 1.05 diameter. The actuator must provide proportional damper control in response to a to 10 VDC or, with the addition of a 500Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counterclockwise failsafe operation. Actuators shall use a brushless DC motor controlled by a microprocessor and be protected from overload at all angles of rotation. Run time shall be constant, and independent of torque. A to 10 VDC feedback signal shall be provided for position feedback. Actuators shall be culus Approved and have a 5 year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Up to 4 actuators may be connected in parallel. With 4 actuators wired to one 500 Ω resistor. Power consumption must be observed. 3 Actuator may also be powered by 4 VDC. For end position indication, interlock control, fan startup, etc., NFB4-4 SR-S and NFX4-SR-S incorporates two built-in auxiliary switches: x SPDT, 3A (0.5A) @50 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. 5 Only connect common to neg. ( ) leg of control circuits WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 Line Volts 4 VAC Transformer Control Signal ( ) to 10 VDC (+) to 10 VDC control of NFB4-SR and NFX4-SR 1 Common 3 + Hot 3 Y 1 Input, to 10V 5 U Output to 10V NFB4-SR, NFB4-SR-S NFX4-SR, NFX4-SR-S NFB4-SR, NFB4-SR-S NFX4-SR, NFX4-SR-S 4 to 0 ma control of NFB4-SR and NFX4-SR with to 10 VDC feedback output NFB4-SR-S NFX4-SR-S Auxiliary switches for NFB4-SR-S, NFX4-SR-S W068_NFB(X)4-SR W069_NFB(X)4-SR W064_NFB(X)4_SR_-S The ZG-R01 500 Ω resistor converts the 4 to 0 ma control signal to to 10 VDC. 65

NFB4-MFT, NFB4-MFT-S, NFX4-MFT, NFX4-MFT-S Proportional, Spring Return, Multi-Function Technology Torque min. 90 in-lb Control to 10 VDC (DEFAULT) Feedback to 10 VDC (DEFAULT) Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB... 66 NFX... Overload protection Operating range Y* Input impedance Feedback output U* Torque Direction of rotation* NFB4-MFT, NFB4-MFT-S, NFX4-MFT, NFX4-MFT-S 4 VAC ±0%, 50/60 Hz 4 VDC +0% / -10% running 6.5 W holding 3 W 9 VA (class power source) 3 ft, 18 GA appliance cable, 1/" conduit -S models: Two 3 ft, 18 gauge appliance cables with 1/ conduit s 3 ft [1m], 10 ft [3m] or 16 ft [5m] 18 GA appliance or plenum cables, with or without 1/ conduit -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [5m] appliance cables with or without 1/" conduit s Electronic throughout 0 to 95 rotation to 10 VDC, 4 to 0mA (default) Variable (VDC, PWM, Floating Point, On/Off) 100 kω for to 10 VDC (0.1 ma) 500 Ω for 4 to 0 ma 1500 Ω for PWM, Floating Point, On/Off to 10 VDC (max. 0.5 ma) 90 in-lb [10 Nm] minimum spring reversible with CW/CCW mounting motor reversible with built-in switch Mechanical angle of rotation* 95 (adjustable with mechanical end stop, 35 to 95 ) Running time spring < 0 sec @ -4 F to 1 F [-0 C to 50 C]; < 60 sec @ - F [-30 C] motor* 150 secs (default), variable (40 to 0 secs) Angle of Rotation Adaptation* Off (Default) Override control* Min Position = 0% Mid. Position = 50% Max. Position = 100% Position indication visual indicator, 0 to 95 (0 is full spring return position) Manual override 5 mm hex crank (³ ₁₆" Allen), supplied Humidity max. 95% RH non-condensing Ambient temperature - F to 1 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing Nema, IP54, Enclosure Type Housing material Zinc coated metal and plastic casing Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/95/EC Noise level 40dB(A) motor @ 150 secs, run time dependent 6dB(A) spring return Servicing maintenance free Quality standard ISO 9001 Weight 4. lbs (1.9 kg), 4.3 lbs (.0 kg) with switches *Variable when configured with MFT options. Rated Impulse Voltage 800V, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3. Programmed for 40 sec motor run time. At 150 sec motor run time, transformer sizing is 6.5 VA and power consumption is 4.5 W running / 3 W holding. NFB4-MFT-S, NFX4-MFT-S Auxiliary switches x SPDT 3A (0.5A) @ 50 VAC, UL Approved one set at +10, one adjustable 10 to 90 Application For proportional modulation of dampers and control valves in HVAC systems. The NFB4-MFT and NFX4-MFT provides mechanical spring return operation for reliable fail-safe application. Default/Configuration Default parameters for to 10 VDC applications of the NFB4-MFT and NFX4- MFT actuator are assigned during manufacturing. If required, custom versions of the actuator can be ordered. The parameters noted in the Technical Data table are variable. These parameters can be changed by three means: Pre-set configurations from Belimo Custom configurations from Belimo Configurations set by the customer using the MFT PC tool (version 3.4 or higher) software application. Handheld ZTH-GEN Operation The NFB4-MFT, NFX4-MFT actuator provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The actuator will synchronize the 0 mechanical stop or the damper or valves mechanical stop and use this point for its zero position during normal control operations. The actuator uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact position. The ASIC monitors and controls the brushless DC motor s rotation and provides a Digital Rotation Sensing (DRS) function to prevent damage to the actuator in a stall condition. The position feedback signal is generated with out the need for mechanical feedback potentiometers using DRS. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The NFB4-MFT, NFB4-MFT-S, NFX4-MFT and NFX4-MFT-S is mounted directly to control shafts up to 1.05 diameter by means of its universal clamp and anti-rotation bracket. A crankarm and several mounting brackets are available for damper applications where the actuator cannot be direct coupled to the damper shaft. The spring return system provides minimum specified torque to the application during a power interruption. The NFB4-MFT, NFB4-MFT-S, NFX4-MFT and NFX4-MFT-S actuator is shipped at +5 (5 from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. NOTE: Refer to Multi-Function Technology documentation. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered 1.05" Centered WAFBNFBDim

NFB4-MFT, NFB4-MFT-S, NFX4-MFT, NFX4-MFT-S Proportional, Spring Return, Multi-Function Technology Accessories AV 8-5 Shaft extension IND-AFB Damper position indicator KH-AFB Crankarm K7- Universal clamp for up to 1.05 dia jackshafts TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket W600_A ZG-118 Mounting bracket for Barber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new crankarm type installations ZG-AFB Crankarm adaptor kit ZG-AFB118 Crankarm adaptor kit ZS-100 Weather shield (metal) ZS-150 Weather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing NOTE: When using NFB4-MFT, NFB4-MFT-S, NFX4-MFT and NFX4-MFT-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to Belimo Wiring Guide. NFB4-MFT-S NFX4-MFT-S Auxiliary Switches for NFB4-MFT-S, NFX4-MFT-S W399_08 Typical Specification Spring return control damper actuators shall be direct coupled type which require no crankarm and linkage and be capable of direct mounting to a jackshaft up to a 1.05 diameter. The actuator must provide proportional damper control in response to a to 10 VDC or, with the addition of a 500Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counterclockwise failsafe operation. Actuators shall use a brushless DC motor controlled by a microprocessor and be protected from overload at all angles of rotation. Run time shall be constant, and independent of torque. A to 10 VDC feedback signal shall be provided for position feedback. Actuators shall be culus Approved and have a 5 year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. VDC/4-0 ma W399_08 Wiring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 4 VDC. Position feedback cannot be used with Triac sink controller. 4 The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) 5 or the Common (sink) 4 VAC line. Contact closures A & B also can be triacs. 8 A & B should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator 9 must be connected to the hot connection of the controller. Meets UL requirements without the need of an electrical ground connection. PWM On/Off control W399_08 W399_08 The ZG-R01 500 Ω resistor may be used. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Floating Point control 67